Technology Solutions Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys

Similar documents
TEK-THERMAL 1700B. Thermal Mass Flowmeter. FLOW. Technology Solutions

T EK-COR 1100A. Coriolis Mass Flowmeter. FLOW. Technology Solutions

TEK-SUB 4800B. Submersible Level Transmitter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys LEVEL

COMPAFLOW. Compressed Air. Volumetric flow. Gas. Mass flow. Steam. Net volumetric flow. Liquid

For Multi-Parameter Meters see mvx

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

T EK-COR 1100A Coriolis Mass Flowmeter

For Multi-Parameter Meters see mvx

Integral type Differential pressure flowmeter VNT Series

Differential Pressure Transmiter

Shanghai AEAD Technology Co., Ltd Professional Manufacturer of Flow, Level, Pressure, Temperature

The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions

Level transmitter LT 100

Flow and Energy Measurement F-5400 THERMAL MASS FLOW METER

Ultrasonic level transmitter and indicator

Pro-V Multivariable Flowmeter

T EK-SUB 4800C 19 mm Submersible Level Transmitter

780S Ultra High Purity Series

Level transmitters and indicators Series LU Ultrasonic level transmitter and indicator for liquids and solids

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C)

9700 Transmitter Submersible hydrostatic level transmitter

Features. Description

Over 20,000 Strain Gage Target flowmeters installed since 1952.

DTG - LCD Digital Temperature Gauge USER MANUAL

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

analytical bulk flow distance FLOW level pressure temperature industrial communication

ABB MEASUREMENT & ANALYTICS DATA SHEET. WaterMaster FEW530 Electromagnetic water meter

KDV HIGH ACCURACY GLASS TUBE ROTAMETER

RTX 1000H Series. Versatile Transmitters for a World of Pressure. GE Measurement & Control. Features

ABB Instrumentation. Specifications. MagMaster Plus MFF Series Electromagnetic Sensors. MagMaster Plus bringing unsurpassed flowmetering performance

High-performance submersible pressure transmitter For level measurement Model LH-10

3000 Series OPTIMASS Mass Flowmeter. Stainless Steel Hastelloy

GA24 Technical Datasheet

VersaFlow Vortex 100 Vortex Flow Meter Technical Datasheet. Specification. The all-in-one solution. Highlights. Industries.

Torque Tube TB300 Digital Transmitters

PanaFlow MV82. Insertion Style Multivariable Flowmeter. GE Measurement & Control. Key Benefits. Applications

L (up to 25 m) Electronic part. working temp.: Ñ IP 66 / IP67. Mounting bracket ÐÑ. Sensor type. working temp.:

STANDARD SPECIFICATION FOR FLOW INSTRUMENTS DOCUMENT NO : 44-LK /J.02/0006-A4

Ultra High Purity Model 780S

How to specify a product. Process Sensors and Mechanical Instruments

Online data sheet FLOWSIC30 GAS FLOW METERS

Hydrostatic & Submersible. Level instruments. for the Australian market

L3 Pressure and Level transmitter

Wafer type. the product

Orifice Plate Flow Meter

TFE-LINED VAREA-METER PVC-TUBE VAREA-METER

Flow metering in gases Introduction to COMBIMASS family

2600T Series Pressure Transmitter Models 264DC Differential and 264HC Gage Level Transmitters. Kent-Taylor

Design Features. General Description

TransPort PT878GC Panametrics Ultrasonic Portable Gas Flowmeter. GE Infrastructure Sensing. Features. Applications

KDV HIGH ACCURACY GLASS TUBE ROTAMETER

OPTIBAR P 1010 C Technical Datasheet

Flow Sensors & Hydrometers Specification Sheet

Mobrey 9700 Transmitter Submersible Hydrostatic Level Transmitters

3.0 Pressure Transmitter Selection

Level MEASUREMENT 1/2016

Electro-Magnetic Flowmeters Electromagnetic Sensor

TH-1800-T TRX-700-CNG Converter

C-Flow Coriolis Mass Flow Meters

RCD - Ultra-Rugged Differential Pressure Flowmeter

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C)

P9000 DESCRIPTION. For parts requiring RoHS compliance, please contact factory. P February /6

Vortex flow sensor VA Di Ex-d with integrated, configurable transducer UVA in a flameproof enclosure for applications in explosive atmospheres

7000 Series OPTIMASS Mass Flowmeters. Titanium Hastelloy Stainless Steel

ellison sensors international

Flowatch Multiphase Flow Meter

Features. Main Voltage: Vdc. Input Control Signal: 0-5 Vdc or 4-20 madc (Sourcing) Monitor Output Voltage: 0-5 Vdc or 4-20 madc (Sourcing)

ISO 9001/ Model SDT-420. Torque Tube, Displacement Type Level Transmitter

Mass Flow Meter (MFM) for gases

Technical Datasheet. D Series SMART Pressure Transmitter Model: DPC D-Series. Key Features. Series Overview. Product applications

Measurement of Low GAS & Liquid Flows

TransPort PT878GC Panametrics Portable Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features

VA40 - VA45 Technical Datasheet

T EK-THERMAL 1700B Thermal Mass Flowmeter

Porter Analytical & Industrial Products

TEK-M ANIFOLD 7500A. Manifolds. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys ACCESSORIES

Installation, operating and maintenance Instructions for Seemag bypass level indicator

Instructions for SMV 3000 Multivariable Configuration (MC) Data Sheets

deltaflowc deltaflowc Venturi or Probe

Micro Motion 7812 Fiscal Gas Density Meter

Vortex Flow Meter Wafer or Flange Connection. - Steam - Liquid - Gas

GFM. Typical Aluminum GFM Mass Flow Meter NIST MASS FLOW METERS. Principles of Operation. Design Features

Varea-Meter Flowmeters. For Metering and Controlling Flows of Process Fluids

NivuBar Plus II

process measurement solutions The level solutions catalogue

Multiphase MixMeter. MixMeter specification. System Specification. Introduction

KTE6000 / KTU6000 Series OEM pressure transmitters for industrial media

Simple Set. Pressure Independent Control Valves 2 Way 1/2-2

Depth/Level. Druck Submersible Pressure Sensors Product Guide. GE Sensing. Applications. Features

Instrumentation & Data Acquisition Systems

Liquid level instruments BM 24 /BM 51

CANADA SENSORS TECHNOLOGY INC.

Technical Data Sheet. OPTIMASS 7000 Custody Transfer Mass Flowmeter

Lesman Level Instrumentation LSB100/300 Series Basic Bubbler System

Target disk flowmeter Series DP. Instructions manual DP65 DP500. R-MI-DP Rev.: 4 English version

Variable Area Flow Meters

Vortex Flow Sensor VA Di Ex-d for flow measurement in gases; with integrated, configurable transducer UVA in Ex-d housing

Brooks TMF-Zone 1 Models 5816-Ex/5864-Ex

NEW VERSAFLOW CORIOLIS

x act i Precision- Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor

Transcription:

Technology Solutions Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys 01

State-of-the-art measurement solutions Flow Measurement We offer multiple flow measurement technologies to measure liquids, gases, steam and corrosive fluid Temperature Measurement Our field and panel mount designs offer an array of technologies to choose from Accessories To improve the efficiency and durability of a product additional accessories are always of great importance Level Measurement Our specialized level measurement instruments consists of contact, non-contact, differential, displacer, ultrasonic, and float to cater to all types of varied process needs Pressure Measurement Our pressure measurement ranges provide compelling accuracy and reliability TekValSys Diagnostic systems that provide real-time validation and monitoring 02

Flow Measurement Tek-Trol s range of flowmeter monitors mass and volumetric flow of liquids, gases and steam with premium accuracy, high stability and robust operation Coriolis Mass Flowmeter - Tek-Cor 1100A Liquids and Gas Size U shaped: 1½" to 8", Micro-bend: ½" to 8", Triangle: ½" to 1" Measuring Ranges For mass flow rates please refer the catalog Accuracy 0.1% or 0.2% or 0.5% Density Measuring Range 2.30 lb/gal (0.2 to 3 g/cm3) Density Basic Error ±0.02 lb/gal (±0.002 g/cm3) Density Repeatability ±0.01 lb/gal (± 0.001 g/cm3) Repeatability For 0.1% accuracy: ±0.05%, For 0.2% accuracy: ±0.1%, For 0.5% accuracy: ±0.25% Temperature Limits Direct Mount: -58 F to 257 F (-50 C to 125 C) Remote Mount: -58 F to 392 F (-50 C to 200 C) Power Requirements 18 to 28 VDC or 85 to 220 VAC Output signal 4 to 20 ma or 4 to 20 ma with HART or Pulse or Modbus RS 485 Process Connection As per DIN or ANSI Enclosure Rating NEMA 4x (IP67) Agency Approvals NTEP, CE 03

Electromagnetic Flowmeter - Tek-Flux 1400A Compatible conductive liquids Measuring Range For flow range please refer the catalog Liner Materials PTFE or Hard Rubber Electrode Material 316 SS or Hastealloy C Accuracy ±0.5% Repeatability 0.15% Ambient Temperature Sensor (Remote Mount): -4 F to 158 F (-20 C to 70 C) Limits Converter: -4 F to 122 F (-20 C to 50 C) Direct Mount: 14 F to 122 F (-10 C to 50 C) Ambient Magnetic Field 400 A/m Pressure Limit 150 psi for ½" to 6" (10 bar for 15 mm to 150 mm) 232 psi for 8" to 24" (16 bar for 200 mm to 600 mm) 145 psi for 28" (10 bar for 700 mm) Mounting Orientation Horizontal or vertical Process Connection #150 ANSI or AWWA flanges Output 4 to 20 ma; optional HART, Pulse or RS 485 Power Requirements 18 to 28 VDC or 85 to 220 VAC Conductivity 5 μs/cm Weight Refer catalog for net weight Enclosure Rating IP68 Agency Approvals CE 04

Vortex Flowmeter - Tek-Vor 1300C Max. Flow Range Accuracy Repeatability Process Temperature Limits Pressure Limit Mounting Orientation Process Connection Output Power Requirements Enclosure Rating Liquids, Gas and Steam Gas: 197 ft/s (60 m/s) Liquid: 23 ft/s (7 m/s) Steam: 230 ft/s (70 m/s) ±1% of reading 0.3% of reading Standard: 302 F (150 C) Medium: 482 F (250 C) High: 662 F (350 C) 150# ANSI Flange or 300# ANSI Flange Horizontal Wafer or ANSI flange 4 to 20 ma and Pulse; Optional HART or Modbus RS 485 24 VAC or 13.5 to 42 VDC NEMA 4x (IP67) Ultrasonic Clamp-On Flowmeter - Tek-Clamp 1200A Compatible Liquids Wetted Material Sensor: Aluminum alloy or Plastic alloy Accuracy 1% Sensing Method Clamp-on ultrasonic, differential transit time method in direct or reflect mode Pipe Size Range 1200A-S2: ½" to to 4", 1200A-M2: 2" to 28", 1200A-HS: ½" to 4", 1200A-HM: 2" to 28" Display 1200A-100F1: 2" H x 20" W, 2 line x 20 characters 1200A-100M: 2" H x 20" W, 2 line x 20 characters 1200A-100H: 4" H x 16" W, 4 line x 16 characters Power Requirements 1200A-100F1: 85 to 264 VAC or 24 VDC, 1200A-100M: 8 to 36 VDC 1200A-100H: 90 to 230 VAC or Ni-MH battery Temperature Limits 32 F to 320 F (0 C to 160 C) Outputs 1200A-100F1: RS 485, 4 to 20mA and frequency output 1200A-100M: RS 485, 4 to 20 ma and frequency output 1200A-100H: RS 232 Enclosure Rating 1200A-100F1: IP65, 1200A-100M: IP57, 1200A-100H: IP65 05

Thermal Mass Flowmeter - Tek-Thermal 1700B Air and Nitrogen Flow Velocity Range 0.22 to 22 lb.ft/sec (0.3 to 30 Nm/s) or 0.44 to 44 lb.ft/sec (0.6 to 60 Nm/s) or 0.66 to 66 lb.ft/sec (0.9 to 90 Nm/s) or 0.88 to 88 lb.ft/sec (1.2 to 120 Nm/s) or 1.1 to 110 lb.ft/sec (1.5 to 150 Nm/s) Probe material 316 SS Accuracy ±0.5% of FS Measured Variables Mass Flow, Volume Flow, Total Flow, Temperature, Velocity Response time 1 second Temperature Limits -40 F to 302 F (-40 C to 150 C) Max. Pressure Limit 232 PSI (16 bar) Mounting Orientation Horizontal or vertical Process Connection Insertion NPT Output 4 to 20mA with Pulsed output; Optional HART or RS 485 Power Requirements 13.5 to 42 VDC or 85 to 265 VAC Enclosure Rating IP65 06

Orifice Meters - Tek-DP 1610A Liquid and gas Types Square edge concentric, Quadrant edged, Conical entrance, Eccentric, Segmental Plate material SS304, SS316, SS316L as standard. Hastelloy-C, Monel, PP, PVC, PTFE coated Orifice Bore In accordance with ISO-5167, BS-1042, ASME MFC 3M, AGA-3 Pressure Tapping s Corner tappings are recommended for sizes up to 1½"; Flange taps from 2" to 16"; D D/2 taps for higher sizes Gasket Material SS spiral wound + Grafoil, SS spiral wound + PTFE Flange Union Weld neck, Slip on, Threaded, Socket welded with RF or RTJ facing Orifice flanges are in accordance with ANSI B16.36 with minimum flange rating of 300# for sizes up to 8" or male - female flanges in accordance with ANSI B16.5 Cone Flowmeter - Tek-DP 1620A Liquid and gas Size 3" to 48" for any pipe schedule Flanges #150 - #2500 Material All standard materials available Turn down ratio 10:1 Calibrated uncertainty ±0.5% DP transmitter Tek-Bar 3110A Flow Nozzles - Tek-DP 1630A Mounting Types Material Pressure taps Liquid and gas Weld in type, holding ring type, flange type Carbon steel for weld in type, 304SS, 304L SS, 316SS, 316L SS for holding ring type and Ni, Cr, Mo Alloy Steel for flanged type 1D-½D taps 07

Venturi Tubes - Tek-DP 1640A Venturi meter for normal liquids Liquid Size 3" to 48" for any pipe schedule Flanges #150 - #2500 Material All standard materials available DP Transmitter Tek-Bar 3110A Calibrated Uncertainty 1% Venturi meter for wet natural gas Gas Size 3" to 24" for any pipe schedule Flanges #150 - #2500 Material All standard materials available. DP Transmitter Tek-Bar 3110A 08

Level Measurement Tek-Trol s level measurement devices offers the right solution for your level measuring requirements Guided Wave Radar Level Transmitter - Tek-Flex 4100A Liquids and Bulk Solids Wetted Materials 316 SS, PTFE Ranges Up to 10' with minimum dielectric constant of 0.3 Accuracy ±0.039" ( 1 mm) or 0.02% of measured distance, whichever is greatest Repeatability ±0.02" (0.5 mm) Resolution 5 Digits Temperature Limit Electronics: -40 F to 158 F (-40 C to 70 C) Process/Probe: -40 F to 398 F (-40 C to 203 C) Pressure Limits -14.50 PSI to 580 PSI (-1 bar to 40 bar) Power Requirement 24 VDC <3W Output Signal 4 to 20 ma Process Connection ¾" NPT Mounting Orientation Vertical Failsafe User selectable to 3.8 ma, 4 ma, 20 ma, 20.2 ma or last signal Enclosure Rating NEMA 6 Agency Approvals Optional ATEX 09

Ultrasonic Level Transmitter - Tek-Sound 4200A Wetted Materials Ranges Accuracy Response Time Resolution Beam Angle Temperature Limits Pressure Limits Power Requirement Output Signal Process Connection Mounting Orientation Failsafe Memory Weight Enclosure Rating Agency Approvals 10 Liquids and Bulk Solids PVC 9' (2.7 m), 16' (4.9 m), 20' (6.1 m), 30' (9.1 m), 50' (15.2 m), 60' (18.2 m) ±0.25% of max range 2-3 echoes/sec 3 Digits 10 to 12 Electronic Enclosure: -40 F to 140 F (-40 C to 60 C); Temperature Compensation: -40 F to 140 F (-40 C to 60 C) Up to 72 PSI (5 bar) 4 Wire: 115 VAC at 60 Hz or 230 VAC at 50Hz 3 Wire: 12 VDC to 30 VDC 4 to 20 ma as Standard or Optional RS 232 or RS 485 or 750 Ω on 4 Wire 1" NPT or 3" NPT Vertical On lost echo after 60 seconds, user selectable to 2 or 22 ma Non-volatile 4.0 lb (1.8 kg) NEMA 6 (IP68) CE

Radar Level Transmitter - Tek-Wave 4300A Liquids and Bulk Solids Wetted Materials Antenna: Polypropylene (PP) Body Aluminium Ranges 17'(5.1 m), 33'(10 m), 50'(15.2 m), 100'(30.4 m) Accuracy ±0.25% of max range Frequency 5.8 GHz or 6.3 GHz Temperature Limits -40 F to 140 F (-40 C to 60 C) Pressure Limits Upto 72 PSI (5 bar) Power Requirement 2 Wire: 12 VDC to 30 VDC Output Signal 4 to 20 ma with HART Process Connection 1½" NPT or 2" NPT Mounting Orientation Vertical Failsafe On lost echo after 60 seconds to 180 seconds, user selectable to 22 ma or 3.5 ma Enclosure Rating NEMA 6 (IP68) 11

PTFE Submersible Level Transmitter - Tek-Sub 4800A Compatible Liquids Wetted Materials Body: PTFE O-Ring: FKM fluorine rubber Diaphragm: Ceramic (Al₂O₃, 96%) Accuracy ±0.5% FS Maximum Current 4 to 20 ma: 22.8 ma Consumption 0.5 to 4.5 VDC: 2 ma RS485: 6mA Operating Temperature PTFE Model: -20 F to 160 F (-29 C to 71 C) Limit Compensated Temperature PTFE Model: 32 F to 140 F (0 C to 60 C) Range Pressure Ranges 2.8 PSIG ( 2 m H₂O), 5.7 PSIG (4 m H 2 O), 10 PSIG ( 7 m H₂O), 15 PSIG (10.5 m H 2 O) Pressure Type Gauge Power Requirement 12 to 36 VDC Output Signal 4 to 20 ma or RS 485 Response Time 10 ms Maximum Specific Gravity 2.2 Cable PTFE or Polyurethane Mounting Orientation Suspended in Tank Weight 0.9 lb (415 g) 12

Absolute/Gauge Pressure Level Transmitter - Tek-Hydro 4500A-G Compatible Liquids Measuring Range 0.217 PSI to 8700 PSI (0.015 bar to 600 bar) Output 4 to 20 ma with HART Stability ±0.1% URL for 12 Months Response time Update time: 0.25sec Turn on time: 5sec Display LCD display Temperature limit Process temperature: -40 F to 248 F (-40 C to 120 C) Operating temperature: -40 F to 185 F (-40 C to 85 C) Thermal Effect ±[0.025%URL+0.125% Span]/28 C Power Supply 12 to 45 VDC HART loop resistance 250 to 550 ohm Process wetted Material 316 SST Electrical connection ½" 14" NPTF Conduit/Epoxy Coated-Aluminum Housing G½ Conduit/Epoxy Coated-Aluminum Enclosure rating IP67(NEMA 4X) Agency Approval FM/FMC, KOSHA KTL, ATEX 13

Differential Pressure Level Transmitter - Tek-Hydro 4500A-D Compatible Liquids Measuring Range 1.5 in H₂O to 1000 PSI (0.0037 bar to 69 bar) Output 4 to 20 ma with HART Stability ±0.1% URL for 12 Months Response time Update time: 0.25sec Turn on time: 5sec Temperature limit Process temperature: -40 F to 248 F (-40 C to 120 C) Operating temperature: -40 F to 185 F (-40 C to 85 C) Thermal Effect ±[0.025%URL+0.125% Span]/28 C Power Supply 12 to 45 VDC Process wetted Material 316 SST Process connection ¼"-18" NPTF ½"-14" FNPT Connection Adapter (316 SST) for Tek-Hydro 4500A series w/single Diaphragm Seal Electrical connection ½"-14" NPTF Conduit/Epoxy Coated-Aluminum Housing G½ Conduit/Epoxy Coated-Aluminum Enclosure rating IP67(NEMA 4X) Agency Approval FM/FMC, KOSHA KTL, ATEX 14

Temperature Measurement Tek-Trol s Temperature measurement devices provides accurate measurement of temperature even in the most challenging conditions Explosion-Proof Temperature Transmitter - Tek-Temp 2100A Liquids and Gases Temperature Sensor RTD (Pt100), Thermocouple, Resistor, Mili-Volt Temperature Sensor Ranges As per sensor, refer the catalog for details Stability ±0.12% of reading Temperature Limits Without condensing: -40 F to 185 F (-40 C to 85 C) With LCD module: -22 F to 176 F (-30 C to 80 C) Accuracy ±0.003% of span Wetted Materials Housing: Epoxy coated Aluminium Process Connection ½" to 14" NPT Power Requirements 10 to 45 VDC Output Signal 4-20 ma Optional Display 5 digit LCD Weight 2.4 lb (1.2 kg) Enclosure Rating FM for Class I, Division 1 Agency Approvals CE, FM 15

Pressure Measurement Our high-quality pressure measuring devices provides stable, reliable and accurate measurements inprocess industries that requires high-precision measurement solutions Explosion Proof Differential Pressure Transmitter - Tek-Bar 3110A Compatible gases, steam, liquids Wetted Materials 316L SS Accuracy ±0.075% FS Rangeability 50:1 turn down Stability ±0.125% FSO/3 yr Temperature Limits Process: -40 F to 248 F (-40 C to 120 C) Ambient: Without LCD 40 F to 185 F (-40 C to 85 C); With LCD -22 F to 176 F (-30 C to 80 C) Maximum Working 2000 PSI Pressure Limit Thermal Effect ±0.125% span/32 C Power Requirements 11.9 to 45 VDC Output Signal 4 to 20 ma with HART Communication Response Time 0.12 Second Damping Time 0.25 to 60 Second Loop Resistance Operation: 0 to 1500 Ω; HART Communication: 250 to 500 Ω Electrical Connection Two ½" female NPT Process Connections ¼" female NPT Display Optional 5 digit LCD Weight 5.5 lb (2.5 kg) Enclosure Rating NEMA 4X (IP66) and explosion proof for Class I, Div I Agency Approvals CE, FM, and ATEX 16

Explosion-Proof Gauge Pressure Transmitter - Tek-Bar 3120A Compatible gases, steam, liquids, vapors Wetted Materials 316L SS Accuracy ±0.075% FS (at 20 C) Rangeability 50: 1 turn down Stability ±0.125% FSO/3 yr Temperature Limits Process: -40 F to 248 F (-40 C to 120 C); Ambient: Without LCD -40 F to 185 F (-40 C to 85 C); With LCD -22 F to 176 F (-30 C to 80 C) Thermal Effect ±0.125% span/32 C Power Requirements 11.9 to 45 VDC Output Signal 4 to 20 ma with HART Communication Response Time 0.12 Second Damping Time 0.25 to 60 Second Loop Resistance Operation: 0 to 1500 Ω; HART Communication: 250 to 500 Ω Electrical Connection Two ½" female NPT conduit, screw terminal. Process Connections ½" female NPT Display Optional 5 digit LCD Weight 5.5 lb (2.5 kg) Enclosure Rating NEMA 4X (IP66) and explosion proof for Class I, Div I Agency Approvals CE, FM, and ATEX 17

Smart Differential Pressure Transmitter - Tek-Bar 3110B Wetted Materials Accuracy Stability Temperature Limits Pressure Limits Power Requirements Output Signal Loop Resistance Electrical Connection Process Connection Display Weight Enclosure Rating Compatible gases, steam, liquids, vapors Hastelloy C ±0.075% FS (at 20 C) ±0.2% URL/5 yr Process: -40 F to 185 F (-40 C to 85 C) Max pressure: Range: 24" w.c. to 1450 PSI ( 0.06 bar to 100 bar) 10.5 to 55 VDC 4 to 20 ma Operation: 0 to 2119 Ω; HART Communication: 250Ω ½" female NPT conduit ¼" female NPT Optional 5 digit LCD 8.8 lb (4 kg) NEMA 4X (IP66) Smart Gauge Pressure Transmitter - Tek-Bar 3120B Wetted Materials Accuracy Stability Temperature Limits Pressure Limits Power Requirements Output Signal Loop Resistance Electrical Connection Process Connection Display Weight Enclosure Rating Compatible gases, steam, liquids Hastelloy C ±0.1% of URL ±0.2% URL/5 yr Process: -40 F to 185 F (-40 C to 85 C) Max pressure: Range: 5.8 PSIG to 5800 PSIG (0.4 bar to 400 bar) 10.5 to 55 VDC 4 to 20 ma Operation: 0 to 2119 Ω; HART Communication: 250 Ω ½" female NPT conduit ½" male NPT Optional 5 digit LCD 3.43 lb (1.56 kg) NEMA 4X (IP66) 18

Accessories Tek-Trol provides wide range of instrumentation accessories, products and configurations for optimum efficiency and durability for all industrial applications Manifold Valve - Tek-Manifold 7500A End Connections Wetted Materials Pressure Limit Temperature Limit Compatible liquids, gases, or steam Flange x Flange; Flange x ½" FNPT; Male x Female ½" NPT Body, stem, valve assembly: 316 SS; Stem packing: PTFE 6000 PSI (400 bar) PTFE : 450 F (232 C) 19

Validation System Diagnostic systems that provide real-time validation and monitoring TekValSys DP Windows Embedded PC Prognosis PC Hub / Switch Modbus / TCP Data from SP s test facility (p.t. flow rate) Adams Box Black Box H L H DPt L H DPr L DPppl Differential Pressure Transmitter Flow P1 P2 P3 This patented technique has proven to be an extremely powerful tool in ensuring accuracy, providing real-time alerts of meter mismeasurement, and performance shifts, and reducing maintenance overheads on DP systems. Applicable to all types of differential pressure metering systems, including Orifice, Venturi, Cone, Flow Nozzle, and Wedge; TekVal- Sys DP uses 3 Differential Pressure (DP) measurements to monitor the entire pressure field through the meter body. Reduced Financial Exposure to Mismeasurement Reduced Maintenance Cost Reduced Risk to Personnel Health and Safety Assurance of Meter System Performance Possibility of Achieving Financial Payback in Few Days 20

TekValSys GC A unique and comprehensive Condition-Based validation software package for Gas Chromatographs (GCs), comprising GCAS software and Panel PC for hazardous or safe areas. As an automated, condition-based monitoring software, TekValSys GC: Provides real time assurance that the GC is operating correctly Analyzes historical data to identify changes and predict future failures Reduces the need for conventional maintenance and unnecessary costs Determines dynamic GC uncertainty for quantification of GC performance Validates that the pressure let down system provides a representative sample Creates a fully auditable database of GC performance Helps to support and increase a technician's competence level 21

Technology Solutions For Process Measurement Automation & Control Customer and Support 22

www.tek-trol.com 796 Tek Drive Crystal Lake, IL 60014 USA Tel.: +1 847 857 6076, +1 847 655 7428 Fax: +1 847 655 6147