Instruction Sheet. SUPERSEDES: New EFFECTIVE: August 1, 2013

Similar documents
INSTALLATION INSTRUCTIONS

453 Series Steam Heated Vaporizing Regulator

High Pressure Inlet Kits for CONCOA BlendMites and BlendMasters

Scald Protection Three-Way Thermostatic Mixing Valve

J Air and Water Kit Instructions Part# 02584

Scald Protection 3-Way Thermostatic Mixing Valve

U S E R M A N U A L CAUTION. SAVE THESE INSTRUCTIONS Federal (USA) law restricts this device to sale by or on the order of a physician.

Installation, commissioning and servicing instructions

D Series Air and Water Kit Part# 02550

DB 61 Dolphin TMV3 Integrated Thermostatic Mixing Valve

453 Series Steam Heated Vaporizing Regulator

AND OPERATION INSTRUCTIONS

Tempering valve for solar and instantaneous applications Installation, commissioning and servicing instructions 2522HP series

Installation, Operation, and Maintenance Manual

INDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES

CF-SERIES HIGH FLOW REGULATORS

Acid- Rite ph Adjustment System 2500 by Axiall, a Westlake Company

Installation, commissioning and servicing instructions

HAYWARD FLOW CONTROL Series PBV Back Pressure Valve and Series RPV Pressure Relief Valve INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS

ACRYLIC FLOW METERS 0-30, 0-70 & LPM

Vessel Installation and Operating Manual

SMV-001 Thermostatic Shower Mixer Valve Installation Instructions & Adjustment Settings

Installation and Operating Manual

BS Series Basket Strainer

Model 9201E Tempered Water Blending System

SSFU SUPER SPRAYFAST UNIVERSAL ADHESIVE APPLICATOR

Model TWBS.SH Tempered Water Blending System

HAYWARD FLOW CONTROL FLV SERIES, PVC/CPVC FILTER VESSEL INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

Owners Manual Models: 075-AQF-CX. Aquatrol Backwashing Catalytic Carbon Filter. Visit us online at.

User Instruction Manual

Models: C62/63/64-A/D

TOP VALVE. Pat. #5,857,486 & 5,944,050. Mid-Range Pressure PSIG Back Pressure and Pressure Relief Valves. Instruction Manual

CSA Sample Draw Aspirator Adapter Operator s Manual

TOP VALVE. Pat. #5,857,486 & 5,944,050. High Temperature: max. 300 F (149 C) Back Pressure And Pressure Relief Valves. Instruction Manual

D05 Pressure Regulating Valves

DFB FLOW METERS (DESIGNED FOR BLENDERS, DUAL TAPER)

Installation, Operation and Maintenance Manual

1 DRIVE INDUSTRIAL IMPACT WRENCH

TITAN FLOW CONTROL, INC.

Model: 720-UL INSTALLATION OPERATION MAINTENANCE. Bermad Pressure Reducing Valve IOM. Model: FP -720-UL Sizes: 2"-12" BERMAD. Application Engineering

Volt 8000 Series Heated Regulator

Model ASSEMBLY and OPERATING INSTRUCTIONS

MANUAL FOR INSTALLATION, COMMISSIONING AND MAINTENANCE FOR

Model B-1 Pipe Line Strainer 3, 4, 6 & 8 Inch (DN80, DN100, DN150 & DN200) 175 psi (12,1 bar) General Description. Technical Data

AIR INLINE METAL SHEAR

1/2 Twin Hammer Composite. Air Impact Wrench ASSEMBLY AND OPERATING INSTRUCTIONS

INSTALLATION MANUAL Matheson Tri-Gas Cabinet Enclosures

Model: 43T. Bermad Pressure Relief Valve

Commercial Well Tank Installation Instructions

Bermad Pressure Reducing. Model: 42T

92831 TEL: (714) FAX:

RK-IR Sample Draw Aspirator Adapter Operator s Manual

BlenderBuddy 2. Operating Manual & Instructions For Use ENGLISH R233M01 REV. A

Electronic Control Pump Instruction Manual

Latvin Luxury Shower Panel. Telephone Product Specification. ~ Minimum Working Pressure 1.0 bar ~ Maximum Working Pressure 3.

U S E R M A N U A L AIR FLOWMETER. MODELS: 1MFA2001 (shown) 1MFA9001 CAUTION. ISO Certified

Operating Instructions for BAIR22-6 AIR-POWERED CRIMPING TOOL

IMPACT WRENCH ASSEMBLY AND OPERATING INSTRUCTIONS

2-Liter Pressure Cup. Instructions - Parts List C

HAYWARD FLOW CONTROL TFS SERIES FLOW METER INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

I T T Pressure Reducing Valve WARNING INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

INSTRUCTIONS PARTS LIST

TECHNICAL DATA. the Viking Pilot Pressure Regulating Valve 1 Model A-1 Speed Control Assembly: OBSOLETE. the Viking Speed Control Assembly 1

ACCU-MIX 1200 / / 26270

USER MANUAL FLOW SELECTOR PM1000 SAVE THESE INSTRUCTIONS. Federal (USA) law restricts this device to sale by or on the order of a physician.

HORNE 20 THERMOSTATIC MIXING VALVE TYPE H-2003

Angled Sign Light with Shade

Speed control assembly model A-1

Electronic Control Pump Instruction Manual

Model C Pipe Line Strainer 6, 8 & 10 Inch (DN150, DN200 & DN250) 250 psi (17,2) General Description. Technical Data. Page of 6 MAY, 2006 TFP1644

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

KJ4000 Operating Instructions & Parts Manual NSN

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

AQUABLEND MM THERMOSTATIC MIXING VALVE

bathrooms.com Concentric Thermostatic Shower Mixers Cleaning and Care Installation Manual Contents

Electronic Control Pump Instruction Manual

Index Table. Model 794. Installation, Operating and Maintenance Instructions

Self-help Temperature Adjustment

Twin & Triple Control Concealed Thermostatic Shower Valve

Portable Compressed CO 2 Regulator

INSTALLATION INSTRUCTIONS 1/2 THERMOSTATIC VALVE AND TRIM

Push-To-Set Intermittent Suction Unit (PTS-ISU) Instructions for Use

TECHNICAL DATA Q= C. Table 1 - Specifications

AMP Oil Free Manual AMP 50-8-TC AMP 50-6-D AMP General User and Maintenance Instructions

ROPV R40 E Series User Manual

Back Pressure Regulator

HYDROVEX TTT Membrane Flow Regulator

TL-12 FLUSH TANK. Manual Ref. # MN-??? Polyurethane Machinery Corp. REVISION 1.0

Installation & Maintenance Manual. C2 & C3 Manifolds

INSTRUCTIONS PARTS LIST U.S. PAT: 6,874,404; 6,516,707; 6,223,645

PCS 340 Core Saturator : 115 Volt : 230 Volt. Instruction Manual

PC1131 Electric Air Compressor

PENBERTHY SUBMERSIBLE AUTOMATIC SUMP DRAINER INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

Eaton Filtration, LLC

URC Voltage Sensor SEN-VOLT for use with MRX units containing sensor ports

- GAS REGULATOR - COMPACT STYLE

G92 Series BASOTROL Automatic Pilot Gas Valve

OPERATION / 3Z9305G 1:1 RATIO TRITON / Spray Packages / / / List of Models, page 2 / / / 100 psi (7 bar, 0.7 MPa) Maximum Working Pressure

Protocol Switchover Station

553 Series.

Transcription:

Instruction Sheet 102-492 5123-WH-N Lead Free (.25% Pb) Mixing Valve SUPERSEDES: New EFFECTIVE: August 1, 2013 Plant I.D. 001-4206 WARNING: Water temperatures above 120 F can cause serious injury. Mixing valve temperature setting should be done by a licensed professional per local code requirements. Use an accurate water thermometer and verify the final water temperature. The thermostatic strip provided must not be used for final water temperature verification. WARNING: The 5123-WH-N must not be installed on steam systems (water systems only). WARNING: 5123-WH-N mixing valves are not designed to compensate for system pressure fluctuations beyond the valves variation rating and should not be used where more sophisticated pressure compensating temperature controls are required. These mixing valves are not intended to provide protection against thermal shock. CAUTION: Valve must not be subjected to heat during the installation, this may damage the valve s internal components. CAUTION: Do not use excess thread sealant (in any form) as this may cause valve failure. GENERAL: The Taco 5123-WH-N is dual listed for both ASSE 1070 and ASSE 1017 applications. All installations should be carried out by a Licensed Professional. Failure to comply with all aspects of these instructions may result in unsafe performance. All installations must comply with relevant State and Local codes or authorities. Ensure compatibility of valve installation, e.g. temperature of hot water, inlet pressure, flow rates, etc. - refer to specification section. If the site conditions are outside of the specifications for the valve, the site conditions must be corrected prior to installing the valve. Install in accordance with markings on valve body, i.e. hot water inlet - marked H, cold water inlet - marked C and mixed outlet - marked M. Any inconsistency between these instructions and any specific instructions, bylaws or codes issued by local authorities must be referred back to Taco, Inc. prior to any installation taking place. During startup ensure that the valve is set to the desired temperature (valve preset at 115-120 F (46-49 C) with 150 F (66 C) hot water inlet temperature). If the valve temperature needs to be adjusted please refer to the instructions below (MIXING VALVE TEMPERATURE ADJUSTMENT). A temperature strip is provided with each mixing valve and can be used as a reference to set the temperature. The temperature strip must not be used for final temperature verification. NOTE: If the water supply is of poor quality a filter or strainer should be fitted at the system inlet so that both the water heater and the mixing valve are protected from dirt and debris.

INSTALLATION: NOTE: Tee and flexible hose not included. The connection between the mixing valve and the water heater cold inlet may also be accomplished using plumbing approved hard pipe/tubing. Before connecting the tee and mixing valve to the water heater, it is important to consider the alignment required to enable connection of the tee to the mixing valve withthe flexible hose or piping and the positioning of the mixing valve to allow easy access for adjustment. If a recirculation return line is also being installed the position of the recirculation port also needs to be considered. 1. Apply sealing tape to the hot and cold connections on the water heater. Connect the hot inlet of the mixing valve to the hot outlet of the water heater, ensuring that the adjustment mechanism is easily accessible and that the recirculationport is positioned for easy connection to the system return line. 2. Connect the tee to the cold inlet of the water heater, ensuring that its mixing valve connection is aligned to allow connection to the mixing valve via the flexible hose or hard pipe. 3. Connect the flexible hose/hard pipe between the tee and the mixing valve. 4. Connect system cold water inlet supply to the tee inlet and the system hot water outlet supply to the mixing valve outlet. MIXING VALVE TEMPERATURE ADJUSTMENT: Prior to setting the valve it is necessary for the hot water source to be switched on and delivering hot water at the design temperature. WRENCH LOCKING NUT ALLEN KEY 1. Using an accurate thermometer, test the mixed water temperature at the nearest outlet being supplied by the valve. The test outlet should not be a shower with its own temperature limiting control valve. This should be opened to allow a minimum flow rate of 1.5 gpm (6 L/min). Allow the water to run for at least one minute to ensure the mixed water temperature has settled. 2. Holding the 3/16 Allen key (supplied), loosen the locking nut with a 7/16 wrench. 3. Using the wrench to support thelocking nut and prevent it from rotating, turn the Allen key to adjust the outlet temperature - clockwise to decrease the temperature, counterclockwise to increase the temperature - until the desired set point is reached. 4. Holding the Allen key, tighten the locking nut with the wrench.

INSTALLATION IN RECIRCULATED SYSTEMS: RECIRCULATION PORT PLUG The 5123-WH-N includes a recirculation port to allow return water from the system to be connected directly back into the mixing valve. To use this recirculation port, remove the plug using an Allen key (3/8 ). NOTE: This diagram is a guideline only. Any installation of a recirculated system should be undertaken by a qualified tradesman, and in accordance with the relevant codes and State, Provincial and Local Authority requirements. Performance of the system will be dependent on the other components specified within it.

CHECKING/SERVICING THE MIXING VALVE: Note that this thermostatic mixing valve is a SAFETYVALVE. It does not require routine maintenance but should be checked annually to be sure it is functioning properly. For installations with poor or unknown water quality, or other adverse supply conditions, it may be necessary to check the valve a tmore frequent intervals. The temperature should be checked at the same outlet as was used for commissioning in the first instance. If the temperature is more than 5 F from the commissioning temperature, refer to fault finding guide below. There may be some variation in the temperature of the water from the thermostatic mixing valve due to seasonal temperature variations in the cold water supply. The check valve can be easily accessed for cleaning via the flexible hose connection. If the water supply is of poor or unknown quality filters or strainer should be fitted at the inlet to the system such that the cold inlet to both the water heater and the mixing valve are protected from dirt and debris. TROUBLESHOOTING: This troubleshooting table is intended as a helpful guide and is not all inclusive. There could be other causes and solutions. FAULT / SYMPTOM CAUSE POSSIBLE SOLUTION 1. The desired mixed water temperature cannot be obtained or valve is difficult to set. 2. Mix temperature unstable or changing over time. 3. Either full hot or full cold water flowing from outlet fixture. 4. No flow from the valve outlet. Inlet temperatures are not within specification limits. Fluctuating supply pressures. Valve is incorrectly set. Hot/Cold water has migrated to other inlet. Refer also to point 1. Hot or cold water supply failure. Ensure inlet temperatures are within the specified limits for the valve. Install pressure regulating valves on both hot and cold supplies. Adjust mix temperature as required. Verify the check valve is not fouled. Clean if necessary. Restore inlet supplies and check mix temperature. 5. Flow rate reduced or fluctuating. Fluctuating supply pressures. Install pressure regulating valves. 6. Mixed water temperature does not change when temperature adjuster is altered. 7. Hot water flows into the cold water system or vice versa. Check valves fouled. Clean check valves, ensuring debris is removed. 8. Valve is noisy. Excessive water velocity. Valve sized incorrectly. Reduce water velocity (best achieved by fitting a pressure regulating valve). Check valve specifications and ensure the appropriate valve is used for required flow.

SPECIFICATIONS: Hot Water Inlet Temperature: 120-180 F (49-82 C) Outlet Water Temperature Range: 85-130 F (29-54 C) Cold Water Inlet Temperature: 39-80 F (4-27 C) Maximum Design Pressure: 230 psi Minimum Temperature Differential (between hot supply and outlet): 27 F (15 C) Minimum Flow Rate: 1 GPM (3.8 L/min) Allowable Supply Pressure Variation: ±20% 1 Maximum Flow Rate: 12 GPM (45.4 L/min) Accuracy of Outlet Temperature: ±5 F 2 (2.8 C) Notes: 1. Maximum allowable variation in either supply pressure in order to control the outlet temperature to within ±5 F. Warning: Pressure variations outside of this range may cause changes in the outlet temperature. 2. As tested in accordance with ASSE 1070. FLOW CURVE: MAINTENANCE: The Taco 5123-WH-N Mixing Valve is a SAFETY VALVE. It does not require routine maintenance but should be checked annually to be sure it is functioning properly. For installations with poor water quality it may be necessary to inspect the mixing valve more frequently. Replacement element assemblies are available. LIMITED WARRANTY STATEMENT Taco, Inc. will repair or replace without charge (at the company s option) any product or part which is proven defective under normal use within one (1) year from the date of start-up or one (1) year and six (6) months from date of shipment (whichever occurs first). In order to obtain service under this warranty, it is the responsibility of the purchaser to promptly notify the local Taco stocking distributor or Taco in writing and promptly deliver the subject product or part, delivery prepaid, to the stocking distributor. For assistance on warranty returns, the purchaser may either contact the local Taco stocking distributor or Taco. If the subject product or part contains no defect as covered in this warranty, the purchaser will be billed for parts and labor charges in effect at time of factory examination and repair. Any Taco product or part not installed or operated in conformity with Taco instructions or which has been subject to misuse, misapplication, the addition of petroleum-based fluids or certain chemical additives to the systems, or other abuse, will not be covered by this warranty. If in doubt as to whether a particular substance is suitable for use with a Taco product or part, or for any application restrictions, consult the applicable Taco instruction sheets or contact Taco at (401-942-8000). Taco reserves the right to provide replacement products and parts which are substantially similar in design and functionally equivalent to the defective product or part. Taco reserves the right to make changes in details of design, construction, or arrangement of materials of its products without notification. TACO OFFERS THIS WARRANTY IN LIEU OF ALL OTHER EXPRESS WARRANTIES. ANY WARRANTY IMPLIED BY LAW INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS IS IN EFFECT ONLY FOR THE DURA- TION OF THE EXPRESS WARRANTY SET FORTH IN THE FIRST PARAGRAPH ABOVE. THE ABOVE WARRANTIES ARE IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR STATUTORY, OR ANY OTHER WARRANTY OBLIGATION ON THE PART OF TACO. TACO WILL NOT BE LIABLE FOR ANY SPE- CIAL, INCIDENTAL, INDIRECT OR CONSE- QUENTIAL DAMAGES RESULTING FROM THE USE OF ITS PRODUCTS OR ANY INCIDENTAL COSTS OF REMOVING OR REPLACING DEFECTIVE PRODUCTS. This warranty gives the purchaser specific rights, and the purchaser may have other rights which vary from state to state. Some states do not allow limitations on how long an implied warranty lasts or on the exclusion of incidental or consequential damages, so these limitations or exclusions may not apply to you. TACO, INC., 1160 Cranston Street, Cranston, RI 02920 Telephone: (401) 942-8000 FAX: (401) 942-2360. TACO (Canada), Ltd., 8450 Lawson Road, Unit #3, Milton, Ontario L9T 0J8. Telephone: 905/564-9422. FAX: 905/564-9436. Visit our web site at: http://www.taco-hvac.com Printed in USA Copyright 2013 TACO, Inc.