Materials : Forged carbon steel A105N

Similar documents
Forged stainless steel ASTM A182 F316

DN 3/8" to 4" Female BSP - 10 C C Max Pressure : 16 Bars up to DN 2 Specifications : Removable stainless steel filter Female / Female

DN 1/2" to 2" Female BSP + 0 C C Max Pressure : 16 Bars Specifications : Stainless steel removable filter Female / Female With draining valve

Materials : Stainless steel ASTM A351 CF8M

Materials : Carbon steel ASTM A216 WCB

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron body

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron body

Materials : Forged carbon steel A350 LF2

Materials : Forged carbon steel A105N

DN 1/2" to 2 Female - Female BSP - 20 C C Max Pressure : 16 Bars Specifications : Rotating non rising stem Inside screw stem Full bore

Materials : Forged carbon steel A105N

Materials : Stainless steel ASTM A351 CF8M

DN 1/2" to 2" Female / Female BSP - 5 C + 60 C Max Pressure : 5 Bars Specifications : Anti blow-out stem Double o ring NBR on stem Full bore

DN 1/4" to 3" Female BSP - 10 C C Max Pressure : 25 Bars ( up to DN 1 ) Specifications : Anti blow-out stem With PTFE packing Full bore

Ref GAS WAFER BUTTERFLY VALVE. Model/Ref:

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron EN GJL 250 body. Reinforced lug for DN200 :

Materials : Brass body dezincification-resistant up to DN1 1/4

DN 65 to 100 R.F. PN10 flanges + 5 C + 65 C Max Pressure : 10 Bars Specifications : Brass check valve Controlable With valves DN1/2

Materials : Brass body dezincification-resistant

Materials : Dichromate zinc plated steel flanges or AISI 316

Materials : Electro galvanized steel flanges

Materials : Galvanized steel flanges

Materials : Dichromate zinc plated steel flanges

Size : Connection Ends : Min Temperature : Max Temperature : Materials : Cast iron body

Size : Ends : Min Temperature : Max Temperature : Materials : Galvanized steel flanges

GUKO FDA. einfach. gut. beraten.

VALFONTA INSTRUCTIONS: OPERATION AND INSTALLATION PRESSURE REDUCING VALVE MODEL PRV44

SCA Series Inverted Bucket Steam Traps

STAINLESS STEEL LOW PRESSURE REDUCING VALVE LPRV ELITE

WHEATLEY Series 822/820 Swing Check Valve

Serie 06-M6. Swing wafer check valve. made in. Application fields. Check valves E U R O P E WATER CONDITIONING INDUSTRY

STAINLESS STEEL OVERFLOW VALVE TYPE 417

Series 44 Self-operated Pressure Regulators. Type 44-0 B Pressure Reducing Valve. ANSI version

PTF4 Pivotrol Pump (patented) version Dual Mechanism - Pressure Powered Pump

GUMMIKOMPENSATOR GKF8000 / GKF8130

WHEATLEY WHEATLEY SERIES 500 SWING CHECK VALVE. Installation, Operation and Maintenance Manual

BTV. Internally threaded 2-way control valve. Flow characteristics. Function

Pilot Operated Pressure Reducing Valve

FTC62 and FTS62 Ball Float Steam Traps Installation and Maintenance Instructions

CONNECTION > Super-rapid fittings Series 6000 GENERAL DATA. Fitting with connecting tube. Sprint

A3S Bellows Sealed Stop Valve Installation and Maintenance Instructions

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

Serie ECO 3T. Threaded end back flow preventer with controllable reduced pressure zone. made in. Application fields. Protection E U R O P E

AVS32 Stainless Steel Air Vent for Steam Systems Installation and Maintenance Instructions

Steam Trap BK 15 (DN40, DN 50) Original Installation Instructions English

FILTER, REGULATOR AND FILTER/REGULATOR Stainless Steel 316L Compact 1/4, High Flow 1/4-1/2

Fig 7, 33, 33.1, 34, 34HP, 36, 36HP, 37, 3616 and Fig 3716 Flanged Strainers Installation and Maintenance Instructions

Steam Trap BK BK 212-ASME. Original Installation Instructions English

Series 44 Self-operated Pressure Regulators. Type 44-1 B Pressure Reducing Valve. Type 44-6 B Excess Pressure Valve. ANSI version

Pressure Reducing Valve for Steam Type 2333 A

CAST IRON SAFETY VALVE TYPE 6301

High Performance BSP Dial Up Pattern Pressure Reducing Valve

WHEATLEY Series 500 Swing Check Valve

Serie ECO 3F. Flanged back flow preventer with controllable reduced pressure zone. made in. Application fields. Protection

Pressure reducing valves Index

HM and HM34 Inverted Bucket Steam Traps Installation and Maintenance Instructions

Installation, commissioning and servicing instructions

Neotecha SAPRO - Aseptic sampling valve SV Installation, operation and maintenance instructions

BTD52L Thermodynamic Steam Trap Installation and Maintenance Instructions

Fig 3, 7, 33, 34, 34HP, 36, 36HP, 37, 3616 and Fig 3716 Flanged Strainers

Regulating valves Type REG 6-65 Type REG-SS REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Installation, Operating and Maintenance Instructions. V914 Cast Iron Flanged Swing Check Valve V914

Differential Pressure Control Valve (DPCV)

USM21 Sealed Bimetallic Steam Trap for use with Pipeline Connectors Installation and Maintenance Instructions

VESSEL & REACTOR VALVES. VS Series SPRAY & RINSE VALVES PROCESS VALVES

CA46S Austenitic Stainless Steel Air and Gas Trap DN40 and DN50

Series 42 Self-operated Regulators Differential Pressure Regulators with Type 2424/Type 2428 Actuator (closing) Type Type 42-28

MZX. Three-Port Seat Valves SPECIFICIATIONS AND GUIDE TO SELECTION

Ball Float Steam Trap UNA 45 MAX, UNA 46 MAX, UNA 46A MAX PN 40/Class 300 DN 40, 50, 65

ROTATING DISK VALVES INSTALLATION AND MAINTENANCE 1. SCOPE 3 2. INFORMATION ON USAGE 3 3. VALVE TYPES 3 4. OPERATORS 5 5. VALVE CONSTRUCTION 6

3-PIECE BALL VALVE, 3600 PSI/ PN 248, WITH ISO DIRECT MOUNTING PAD 306M SERIES/ PED Category II

553 Series.

Gas powered stop valves, type GPLX REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Mounting and operating instructions EB 2530 EN. Self-operated Pressure Regulator. Pressure Reducing Valve Type M 44-2

Si C132. Safety valves for pressure relief in accordance to PED, DIN/EN and ASME. Engineering GREAT Solutions

Ball Float Steam Trap UNA 43 PN 16/CL 125/JIS 10K UNA 46 PN 40/CL 150/CL 300/JIS 10K/JIS 20K DN 80, 100, 150, 3", 4", 6"

Pibiviesse High Performance Control Ball Valve

PC10HP Pipeline Connector (ASME 600)

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401

CA10S, CA14 and CA14S Air and Gas Traps

M45 ISO Ball Valve DN25 to 150 Installation and Maintenance Instructions

TECHNICAL CATALOGUE PRESSURE REDUCING VALVES EUROPRESS

776 Cryogenic Safety Valve

TECHNICAL CATALOGUE PRESSURE REDUCING VALVES EUROPRESS

CA16 and CA16S-14 Air and Gas trap Installation and Maintenance Instructions

PC3_ and PC4_ Pipeline Connectors

VALFONTA INSTRUCTIONS: OPERATION AND INSTALLATION PRESSURE REDUCING VALVE MODEL M2

Versions. Benefits. Balancing DN15-32 DN40 DN50 DN15, DN20, DN25, DN32, DN40, DN50. Dimensions

Mounting and Operating Instructions EB 3017 EN. Self-operated Regulators

Installation, commissioning and servicing instructions

Installation Operation Maintenance. Bermad Level Control Valve with Modulating Horizontal Float Pilot valve One Way Flow IOM.

CALEFFI. Reduced pressure zone backflow preventer. 574 series 01022/18 NA D E C F B D E. Function

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

TDC46M, TDS46M and UTDS46M Thermodynamic Steam Traps with Maintainable Seat Installation and Maintenance Instructions

Self-operated Pressure Regulators for special applications

Installation, Operation and Maintenance Manual for Back Pressure Regulator

Telefon (+45) Telefax (+45)

End Connection. Thread x Thread N/A N/A N/A N/A Flange x Flange N/A

Mounting and Operating Instructions EB 2172 EN. Series 43 Temperature Regulators. Type 43-5 and Type Type Type 43-6

CA14 SG Iron Air and Gas Trap ½" and ¾" (Screwed)

Transcription:

Certificate 3.1 Size : Ends : Min Temperature : Max Temperature : DN 1/4" to 2 Female - Female BSP or NPT, Socket Welding - 29 C + 425 C Max Pressure : 136 Bars (Class 800) Specifications : With draining cap Removable stainless steel filter Materials : Forged carbon steel A105N Page 1 sur 7

SPECIFICATIONS : With draining cap Removable stainless steel filter Respect the flow direction indicated by the arrow Horizontal or vertical position with descendant fluid Mesh 8/10 mm ( 800 µ ) Class 800 USE : Petroleum industry, steam, high pressure Min and max Temperature Ts : - 29 C to + 425 C Max Pressure Ps : 136 bars ( see graph ) PRESSURE / TEMPERATURE RELATION : Pressure (bar) 136.2 136.2 136.2 124,1 120,7 116,6 110 100,7 98,6 97,9 92,7 75,9 Temperature ( C) -29 0 38 93,5 149 204,5 260 315,5 343,5 371 399 425 PRESSURE / TEMPERATURE GRAPH : Pressure (Bars) Temperature ( C) Page 2 sur 7

HEAD LOSS GRAPH : Flow ( L / Min ) RANGE : Forged carbon steel Y strainer threaded female BSP Ref. 231 from DN 8 to DN 50 (NPS 1/4 to DN 2 ) Forged carbon steel Y strainer Socket Welding ends Ref. 232 from DN 8 to DN 50 (NPS 1/4 to DN 2 ) Forged carbon steel Y strainer threaded female NPT Ref. 234 from DN 8 to DN 50 (NPS 1/4 to DN 2 ) Page 3 sur 7

MATERIALS: DN 8 40 (NPS 1/4" - 1"1/2) DN 50 (NPS 2") Item Designation Materials 1 Body ASTM A105 N 2 Bonnet ASTM A105 N 3 Filter SS ASTM A240 316L 4 Gasket AISI 316 + graphite 5 Cap ASTM A105 N 6 Screw ( only for DN50 ) ASTM A193 B7 Page 4 sur 7

SIZE ( in mm ) : DN 8 40 (NPS 1/4" - 1"1/2) DN 50 (NPS 2") Filter size : Ref. DN (mm) 8 10 15 20 25 32 40 50 NPS (") 1/4 3/8" 1/2" 3/4" 1" 1"1/4 1"1/2 2" L 90 90 90 110 130 160 160 160 231 H 60 60 60 75 93 120 120 145 H2 105 105 105 140 155 195 195 205 232 G ( NPT ) 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/2 B 90x90 234 Ø D 18 18 18 22 28 41,5 41,5 49,5 H1 41 41 41 60 75 100,5 100,5 100,5 231/234 L1 10 13 14 16 20 22 22 26 232 E ( SW ) 10 10 10 14 14 14 14 16 Ø F ( SW ) 14.2 17.6 21.72 27.05 33.78 42.54 48.64 61.11 231/232/234 Weight (Kg) 0.85 0.78 0.73 1.22 1.88 4.75 4.45 6.5 Page 5 sur 7

STANDARDS : Fabrication according to ISO 9001 :2008 DIRECTIVE 2014/68/EU : CE N 1115 Risk category III Module H Certificate 3.1 on request Designing according to ASME B16.34 Pressure Tests according to API 598, table 6 Threaded NPT female ends according to ASME B1.20.1 Threaded BSP cylindrical female ends according to ISO 7/1 Rp ATEX Group II Category 2 G/2D Zone 1 & 21 Zone 2 &22 ( optional marking ) according to directive 2014/34/EU INSTALLATION POSITIONS : Horizontal position Vertical position ( descendand fluid ) ADVICE : Our opinion and our advice are not guaranteed and SFERACO shall not be liable for the consequences of damages. The customer must check the right choice of the products with the real service conditions. Page 6 sur 7

INSTALLATION INSTRUCTIONS GENERAL GUIDELINES : Ensure that the strainers to be used are appropriate for the conditions of the installation (type of fluid,pressure and temperature). Be sure to have enough valves to be able to isolate the sections of piping as well as the appropriate equipment for maintenance and repair. Ensure that the strainers to be installed are of correct strenght to be able to support the capacity of their usage. Installation of all circuits should ensure that their function can be automatically tested on a regular basis (at least two times a year). INSTALLATION INSTRUCTIONS : Before installing the strainers, clean and remove any objects from the pipes (in particular bits of sealing and metal) which could obstruct and block the strainers. Ensure that both connecting pipes either side of the strainer (upstream and downstream) are aligned (if they re not, the strainer may not work correctly). Make sure that the two sections of the pipe (upstream and downstream) match, the strainer unit will not absorb any gaps. Any distortions in the pipes may affect the thightness of the connection, the working of the strainer and can even cause a rupture. To be sure, place the kit in position to ensure the assembling will work. The theoretical lengths given by ISO/R7 for the tapping are typically longer than required, the length of the thread should be limited, and check that the end of the tube does not press right up to the head of the thread. Never use a vice to tighten the fixings of the strainer. If sections of piping do not have their final support in place, they should be temporarily fixed. This is to avoid unnecessary strain on the strainer. Fluids in the strainer must not contain solid objects ( it could damaged the seat ). Page 7 sur 7