Airlock Qualification

Similar documents
Rosemount 3159 Nuclear Qualified Remote Diaphragm Seal

Weed Model DTN2070. Differential Pressure Transmitter. Nuclear Qualified

Containment Structure Performance as Controlled by Penetrations and Extensions

VALVE MANUFACTURERS ASSOCIATION API 622 API 624

Custom-Engineered Solutions for the Nuclear Power Industry from SOR

Rosemount 3154K Nuclear Qualified Pressure Transmitter

The latest automotive systems require innovative leak test methods and fixturing.

Test Report # Rev 0. Adiabatic Compression In Nitrogen Service

CURTISS-WRIGHT ELECTRO-HYDRAULIC ACTUATORS FOR MAIN STEAM AND MAIN FEEDWATER ISOLATION VALVES

INSTALLATION COMMISSIONING, OPERATION & MAINTENANCE MANUAL

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS

Discussion on Fugitive Emissions Standards Rich Davis

Slit Valve. XGT Series. Low particle generation. With end lock mechanism. Service life of two million cycles. XLA XL XL Q D- XSA XVD XGT CYV

Rosemount 3152K Nuclear Qualified Pressure Transmitter

CO2 Tank Conversion Kit P.N , P.N , and P.N

TANK MANAGER FOR TWO TANKS OPERATING MANUAL. 10/31/11 C-More T6C L color touch panel

Pneumatic Controls, Air Settings, Hydraulic adjustments on; Models 22HF, 16HF & 1600 machines

Presented to the IAPMO Standards Review Committee on March 7, 2016

Chamber Test Testing Theory

GAS FUEL VALVE FORM AGV5 OM 8-03

Operation Manual Air Saver Unit ASV5000 Series

BUBBLER CONTROL SYSTEM

MDEP Common Position No AP

Technical Service Bulletin March 2015 TSB142.01

CLARKES ERO FEEDER MANUAL

University of Minnesota Nano Center Standard Operating Procedure

Hazardous Energy Control/Lockout

TECHNICAL DATA SINGLE INTERLOCKED PREACTION SYSTEM WITH PNEUMATIC RELEASE

MANUAL GAS MANIFOLDS

OWNER S TECHNICAL MANUAL

A-Series Double Flapgate Airlock Valve

SERVICE MANUAL No. I-0043

DETAILS OF THE ACCIDENT PROGRESSION IN 1F1

Intertek Testing Services Taiwan Ltd.

Development Report. Walker Barrier 10 Ergoclean Gloveport Interface. And. Single Piece Gauntlet Performance Testing

OPERATION OF THE DIMPLER

Safety Powder Spray Systems

Inert Air (N2) Systems Manual

Oxygen Contamination

Test Report # Rev 0. Adiabatic Compression With Constant Bleed Valve

HYDROSTATIC LEAK TEST PROCEDURE

BRILLIANT WONDERS LED BUBBLERS INSTALLATION INSTRUCTIONS CMP SERIES. Brilliant Wonders LED BUBBLERS

Oxygen Usage Best Practice Guide

Reliability: Piping Distribution & Storage Matter. Instructor: Kurt Thielemann Principal

Valves. Diaphragm shut-off valves, kidney-type

Instructions for Installation, Operating and Maintenance

Sterile Visual Flow Indicator

B84G - Excelon Plus Modular System General purpose filter/regulator

RAM 4021-DPX Operation Manual

NOTICE. Issued: February 12, 2010 AO# Dundas Street West, Oakville, ON CANADA Phone: (905) Fax: (905)

VOLUME BOOSTER RELAYS YT-300 / 305 SERIES

Gas Sampling Fitting with MK2.1 and L-Probe

INSTALLATION & MAINTENANCE INSTRUCTION

ITS 300 & 500 SERIES POSITION MONITORING INSTALLATION AND OPERATION MANUAL

Installation, Operation, and Maintenance Manual

Gas Network Craftsperson

Date of Issue: July 2016 Affected Publication: API Specification 16C, Choke and Kill Equipment, Second Edition, March 2015 ADDENDUM 1

OPERATION MANUAL BFX-2

Technical equipment and operation for a refuge room in: Shaft Konrad Mine.

BRILLIANT WONDERS LED BUBBLERS INSTALLATION INSTRUCTIONS & PRODUCT MANUAL CMP SERIES

Single Pressure/ vacuum decay leak rate, loss, rate of loss, or occlusion tests with standard Cv valves.

Review of the Hall B Gas System Hardware. George Jacobs

Kube Engineering Quinn E. Eddins, B.S.E.E Phone

PNEUMATIC PRESSURE CONTROLLERS

SERVICE MANUAL MODEL BA050BMST BREATHING AIR PANEL

Application Note. Safety Sub-functions SSC Category 1, up to PL c PUS Category 1, up to PL c. Application Note SSC, PUS, Category 1, up to PL c STOP

METHOD 21 - DETERMINATION OF VOLATILE ORGANIC COMPOUND LEAKS. 1.2 Scope. This method is applicable for the

HUBEN K1 Pre-charged Pneumatic Air Rifle Owner s Manual

INSTALLATION OPERATION MAINTENANCE

Discharge Relief Valve Operation & Maint.

Succeeding with Production Air Leak Testing Methods. Paul Chamberlain President, CEO

EFFECT OF PACKING MATERIAL AND CONFIGURATION ON ISOLATION VALVE STUFFING BOX LEAKAGE AT CRITICAL OPERATING CONDITION

SRL Series. Oil-less Scroll Air Compressors. Pharmaceutical. Research & Development. Food & Beverage. Chemical. Electronic

Unit 24: Applications of Pneumatics and Hydraulics

Glove Box Installation Manual

BETTIS J1-RT2 RATE OF DROP LINEBREAK DETECTION SYSTEM. FACTORY SET: psi/min psi P/L

ISO Sub-bases. Port sizes G 1 /4 - G1 and 1 /4NPT - 1 /2NPT. Sub-bases tovdma specification, for ISO sizes #1, #2, #3 and #4

Summary of Substantive Changes between the 2004 e1 and 2017 editions of ASSE 1011, Hose Connection Vacuum Breakers

Pneumatic Target Transfer System Model PT01

ASSE International Product (Seal) Listing Program

This test shall be carried out on all vehicles equipped with open type traction batteries.

R I T. Title: STS ASE Semiconductor & Microsystems Fabrication Laboratory Revision: Original Rev Date: 01/21/ SCOPE 2 REFERENCE DOCUMENTS

Gas Flow Calibration Basics

TYPE ECS SEAL METAL BELLOWS DRY-RUNNING SECONDARY CONTAINMENT Technical Specification

Energy Control. Suite 2A, 55 Frid Street Hamilton, ON L8P 4M3 office: cell:

SHUTDOWN SYSTEMS: SDS1 AND SDS2

BUBBLER CONTROL SYSTEM

«DO160/ED14» - Jessica France

Operating Procedures for Metal Evaporator I

PyroShot High Speed (HS) Including Long Range and BackFire options Serial Numbers HS-301 and above

PANACEA P200 STAINLESS STEEL USER MANUAL

MoveRoll Conveyor Operating and Maintenance Manual

Flow meter. bellow vaporizer. APL valve. Scavenging system

Title: Xactix XeF2 Etcher Semiconductor & Microsystems Fabrication Laboratory Revision: A Rev Date: 03/23/2016

Operating Instructions

Automotive Safety Checklist

Limited quantities of compressed gases.

A AMM - AIR SUPPLY - DESCRIPTION AND OPERATION

RAM 4021 Operation Manual

PVC Quick Drain Valve

Transcription:

Airlock Qualification Presentation to IEEE SC-2 Marie Nemier June 4, 2013

Containment Airlocks

Containment Airlock The safety function of an airlock is to maintain pressure boundary Due to the size and complexity of the airlock, the environmental and seismic qualification is performed by evaluating the safety function of various sub-assemblies Different qualification methods & requirements are used for the various sub-assemblies

Containment Airlock Subcomponents Electrical Control System Pressure Transmitters Drive Mechanism Compression Seals Pneumatic Pressure Controls Site Glass

Containment Airlock Electrical Control System The electrical control system is non-safety however it a concern was raised that the a control panel sub-component may spuriously operate due to EMI/RFI If the assembly received a spurious signal engage/disengage the brakes, the airlock may malfunction. EMI/RFI testing was performed and the test sample assembly was monitored as a system for spurious change of state of the brakes.

Containment Airlock Electrical Control System Electrical control system contains the following components: PLC Panel Junction Boxes Indicating and Display Station Door Brakes Door Brake Control Box Limit (proximity) Switch Pressure Transmitter Various Wiring in Conduit

Containment Airlock Electrical Control System Components were evaluated to determine susceptibility to EMI/RFI Individual components were not monitored. Faulty indications were not considered a failure however; they were noted in the report. EMI/RFI tests performed in accordance with APP-GW- G1-002 Revision 2 & Regulatory Guide 1.180

Containment Airlock Pressure Transmitter Safety Function: Pressure boundary only A transmitter was selected with a graphite seal so that environmental qualification was performed by analysis Seismic qualification was performed by test to the specification RRS

Containment Airlock Drive Mechanism Safety Function: Structural integrity and post-seismic operability Mechanical cycle aging was performed by analysis Seismic qualification was performed by test to the specification RRS

Containment Airlock Compression Seal Safety Function: Pressure boundary only Environmental qualification performed by test Test sequence Service Life of seals 5 years Radiation TID (gamma)* 200 Mrad Operational cycles, airlock 20 times/week Peak Accident Temperature 360 F Peak Accident Pressure 60 psig Chemical Spray (boric acid) 4400 ppm *1 beta radiation has been directly added to gamma radiation

Containment Airlock Compression Seal 500 450 400 350 Trentec Seal Test Fixture LOCA SK3 & 4 Temperature Test Results AP1000 Required Temperature SK3 & 4 Pressure Test Results 250 200 Temperature ( F) 300 250 200 150 100 Pressure (psig) 150 100 50 50 0 0 0.01 0.10 1.00 10.00 100.00 1000.00 10000.00 100000.00 1000000.00 10000000.00 Time (seconds)

Containment Airlock Compression Seal Safety Function: Pressure boundary only Environmental qualification performed by test Test sequence Service Life of seals 5 years @ 120ºF Radiation TID (gamma)* 46.5 Mrad Operational cycles, airlock 12 times/year Peak Accident Temperature 360 F Peak Accident Pressure 60 psig Chemical Spray (boric acid) 4400 ppm Chemical Spray (tri-sodium phosphate) 7.53 g/l 1 Year Post-Accident Submergence *1 beta radiation has been added to gamma radiation

Containment Airlock Compression Seal Each test fixture contains o-rings representative of door o-rings and shaft hub o-rings

Containment Airlock Compression Seal Leakage criteria: The safety function of the o-ring is to not exceed the total barrel leakage rate of 1.7 slm (1700 sccm) at the design conditions of 59 psig and 300 F. The leakage rate shall not exceed 13 sccm for the the door o- ring and 59 sccm for the shaft o-ring.

Mechanical cycling

Containment Airlock Compression Seal Seals in test fixture on LOCA Chamber

Containment Airlock Compression Seal

Containment Airlock Compression Seal 100 11-033S: QualTech Seals EQ LOCA Test Started 09 Apr 2013 90 80 Absolute Pressure (psia) 70 60 50 40 30 20 10 0 5 10 15 20 25 30 35 40 Elapsed Time (seconds)

Containment Airlock Compression Seal Seals in test fixture moving from LOCA Chamber to submergence chamber

Containment Airlock Pneumatic Pressure Controls Airlock pressure controls for pneumatic systems with inflatable seals Components include manual valves and pressure switches Safety Function: Maintain pressure boundary Seismic qualification performed by test

Containment Airlock Site Glass Safety Function: Maintain pressure boundary Environmental qualification performed by test

Containment Airlock Site Glass Test sequence Radiation aging to 234 Mrads Thermal aging to simulate 40 year life, 103 hours at 240ºF Mechanical cycle aging for 700 compression cycles one side of the site glass was pressurized at 0 to 70 to 0 psig Severe Accident Test: 24 hours at 405ºF at 105psig

Containment Airlock Site Glass 450 Trentec Sightglass Severe Test started 12 May 2010 400 350 300 Temperature ( F) 250 200 150 100 50 0 10000 20000 30000 40000 50000 60000 70000 80000 90000 100000 Elapsed Time (seconds)

Containment Airlock Site Glass

Questions QualTech NP 4600 East Tech Dr. Cincinnati, OH 45245 513-528-7900