6833_INSTRUCTIONS MANUAL DIGITAL WIRST BLOOD PRESSURE

Similar documents
Contents. Safety Notice. Wrist Type

MANUAL BLOOD PRESSURE MONITOR BPM 168B Contents Blood Pressure Monitor Intended Use What is blood pressure?

Introduction. Table of Contents. Automatic Wrist Blood Pressure Monitor With Voice-Guided Operation. Model No.: BP5K

CONTENTS SPECIFICATIONS GENERAL INFORMATION RECOMMENDED USE OPERATING PRINCIPLE TIPS ON TAKING YOUR BLOOD PRESSURE 3-4 BATTERY INSTALLATION

SBC 21. Electromagnetic Compatibility Information

User Manual. Hopkins IMPACT Digital Wrist BP RELATED ITEMS. Item #526014

Fully Fuzzy Auto Digital Wrist Blood Pressure Monitor. tensio control. INSTRUCTION MANUAL Model GP-6220

Digital Blood Pressure Monitor for the Upper Arm INSTRUCTION MANUAL

VER: A00. Model No:BA2010

INSTRUCTION MANUAL. Automatic Blood Pressure Monitor with Fit Cuff. =Fit Cuff=!"#$% IA1B. Model

REF CH-602B IDENTIFICATION OF PARTS

Sports Wrist Digital Blood Pressure Monitor Item #

Model UB-328. Wrist Digital Blood Pressure Monitor. Instruction Manual. Manuel d instructions. Manual de Instrucciones. Manuale di Istruzioni

Model AUTOMATIC UPPER ARM Blood Pressure Monitor

MEDICARE 60. Semi-automatic upper arm blood pressure monitor. Instruction manual

REF CH-302B IDENTIFICATION OF PARTS

Semi-Automatic Blood Pressure Monitor with Memory

Auto Arm Blood Pressure Monitor

Fully Automatic ihealth Track Connected Arm Blood Pressure Monitor USER MANUAL

Oregon Scientific Wrist Blood Pressure Monitor (BPW211)

TD-3140 Blood Pressure Monitor. Owner s Manual

TD-3140 Blood Pressure Monitor. Owner s Manual

Wrist Blood Pressure Monitor Model R2

Talking Wrist TypeBlood Pressure Monitor. Talking Wrist Type Blood Pressure Monitor Model: BPW810. User Manual

User Manual DMD1001. Arm Type. Digital Blood Pressure Monitor. version:1.0

Instruction Manual. Gebrauchsanweisung Manuale di istruzioni Manual de instrucciones Gebruiksaanwijzing РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ

Wrist Type Blood Pressure Monitor

INSTRUCTION MANUAL MANUAL INFLATION BLOOD PRESSURE MONITOR

Fully Automatic Blood Pressure Monitor

User Manual DMD1001. Arm Type. Digital Blood Pressure Monitor. version:1.0

Owner's Manual. Wrist-type Fully Automatic Blood Pressure Monitor. Contents. Safety Notice. Model BP2116. Document No. Version: REV

VIDEO TUTORIAL: greatergoods.com/0605

Instruction Manual. Auto Inflate Blood Pressure Monitor

Instructions for use. 3year. Wrist MOBIL BASIS. The monitor for first users To be used on the wrist. Also suitable for: WARRANTY. Clinically validated

Operating Instructions Instrucciones de funcionamiento

Check following components!

VGP-4300-G. Travel Pulse. Blood Pressure Monitor for Travel

English Español Português Italiano Deutch Français INSTRUCTION MANUAL FOR DIGITAL BLOOD PRESSURE MONITOR MODEL CH-656C. - Eng 1 -

Instruction Manual Mode d emploi Gebrauchsanweisung Manuale di istruzioni Manual de instrucciones Gebruiksaanwijzing РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ

MODEL CH-432B INSTRUCTION MANUAL FOR DIGITAL BLOOD PRESSURE MONITOR. - Eng 1 - English Español Português Deutch. Italiano Français CH-432B

Oregon Scientific Wrist Blood Pressure Monitor (BPW120)

User Manual DMD1001 1

Content

Talking Wrist Style Blood Pressure Monitor Model INS-LAB-RevB08

Contents. Helpline No. UK/Northern Ireland , Rep. Ireland Web Support Model Number:

Owner s Manual. EZ Health TM Platinum Talking Automatic Wrist Blood Pressure Monitor ABP-A3

Instruction Manual Mode d emploi Gebrauchsanweisung Manuale di istruzioni Manual de instrucciones Gebruiksaanwijzing

Blood Pressure Monitor

Device Equivalence Evaluation Form Comparison of the Omron RS2 (HEM 6121 E) with the Omron RS3 (HEM 6130 E)

premium wrist blood pressure monitor

GoWISE USA R Blood Pressure Monitor Wrist Type. Instruction Manual

ProSeries 2. Blood Pressure Monitor. Quick Start Guide. A complete user guide is available at vitasigns.com

Digital Blood Pressure Monitor. Model UA-705. Instruction Manual. Manuel d instructions. Manual de Instrucciones. Manuale di Istruzioni 1WMPD B

Digital Blood Pressure Monitor. Model UA-787

INSTRUCTION MANUAL MANUAL INFLATION BLOOD PRESSURE MONITOR

Model M3 Intellisense

Owner s Manual & Safety Instructions

Blood Pressure Monitor Instruction Manual

5 series Blood Pressure Monitor

Model MIT Elite Plus

Instruction Manual. S&S Tradings

Module No GETTING ACQUAINTED GENERAL GUIDE TIMEKEEPING

.$2;,)*3/6$ USER MANUAL

Device Equivalence Evaluation Form

Instruction Manual Mode d emploi Gebrauchsanweisung Manuale di istruzioni Manual de instrucciones Gebruiksaanwijzing

Instruction Manual. Wrist Blood Pressure Monitor with Advanced Positioning Sensor (APS ) Model HEM-650 ESPAÑOL ENGLISH

Device Equivalence Evaluation Form

INSTRUCTION MANUAL FOR DIGITAL BLOOD PRESSURE MONITOR

Device Equivalence Evaluation Form

Model UA-705. Digital Blood Pressure Monitor 使用手冊翻譯. Instruction Manual. Manuel d instructions. Manual de Instrucciones. Manuale di Istruzioni

Instruction Manual. Automatic Blood Pressure Monitor for Arm - Voice Prompt Function Announces Measured Values HB-ZA310V

Digital Blood Pressure Monitor Model UA-621 Instruction Manual

WARNING: EXPLOSION HAZARD

SpotArm Type Blood Pressure Monitor. Model i-q142

Digital Automatic Wrist Blood Pressure Monitor Model R6 Instruction Manual. English Français Deutsch Italiano Espanõl Nederlands Русский

User Manual. Wrist Blood Pressure Monitor. Wrist Type

LD6. Digital Blood Pressure Monitor Instruction Manual

REF CH-308B INSTRUCTION MANUAL FOR DIGITAL BLOOD PRESSURE MONITOR IDENTICATION OF PARTS Eng 1 - Exhaust button Air connector Pumping bulb tube

INSTRUCTION MANUAL DIGITAL BLOOD PRESSURE MONITOR

BM 26 ENGLISH. Blood pressure monitor Instructions for use... 2

INSTRUCTIONS FOR USE

Blood Pressure Monitor Instruction Manual

DYNAMIC COMPRESSION THERAPY

Med Aire Alternating Pressure Pump and Pad System

Digital Wrist. Blood Pressure Monitor Advanced Wrist Monitor Instruction Manual

MODEL CH-485E INSTRUCTION MANUAL FOR DIGITAL BLOOD PRESSURE MONITOR. English Español Português Deutsch. English Español Português Deutch Français

Omron Blood Pressure Monitor Need Manual Bp760 Automatic

Blood Pressure Monitor

Check following components! Vérifier les composants suivants! Digital Automatic Blood Pressure Monitor Model M3 Instruction Manual

LD22. Digital Blood Pressure Monitor Instruction Manual

TMB-986 英文说明书 (A0 ) 印色 : 单黑材质 :80G 书纸尺寸 :170*120mm

Automatic Blood Pressure Monitor Model M6 Instruction Manual

Instructions for use. Recognises atrial fibrillation The most frequent cause of stroke. Upper arm PROFESSIONELL TOUCH. Also suitable for:

Instructions. Upper Arm Blood Pressure. Model EW3153

Model UA Digital Blood Pressure Monitor 使用手冊翻譯. Instruction Manual. Manuel d instructions. Manual de Instrucciones. Manuale di Istruzioni

LD7. Digital Blood Pressure Monitor Instruction Manual. Ciśnieniomierz elektroniczny automatyczny LD Instrukcja Obsługi ENG POL

Gebrauchsanweisung Mode d' emploi Instrucciones para el uso Istruzioni per l'uso Инструкции по зксплуатации. ri-fox N

Blood Pressure Monitor

User Manual. Blood Pressure Monitor. Arm Type

Blood Pressure Monitor

Transcription:

6833_INSTRUCTIONS MANUAL DIGITAL WIRST BLOOD PRESSURE PURCHASE ACKNOWLEDGEMENT JOCCA thanks you for the trust placed in the purchase of our product and we are certain that you will always be satisfied with any of our products. PRODUCT DESCRIPTION a-adjustment (S Set) b-operation (M Mode) c-start/stop d-lcd screen e-memory read (RECALL) f- Wrist cuff g-storage box h-alkaline batteries i- Month j- Day k-hour l- Minutes m-blood pressure icon n-blood pressure reading unit o-battery consumption indicator p-error indication q-memory r- In the afternoon s-systolic t- Diastolic u-pulse v-pulse icon SAFETY WARNINGS -These instructions are very important. Please read this instructions manual carefully before using the appliance and keep it at hand to refer to it at any time. -JOCCA declines any responsibility for the improper use of the product, or any other use that is not described in this manual. -Before using the product for the first time, unpack the product and check that it is in perfect conditions. If not, do not use the appliance and contact JOCCA, as the guarantee covers any damage from origin or manufacturing defects. -This product is only indicated for domestic use. Do not use the appliance outdoors. Never leave the appliance exposed to climatic agents such as rain, snow, sun, etc... which can damage its operation. -This appliance is intended to be used only by adults. Do not allow people not accustomed to this kind of appliances, handicapped people or children to use this item. -Do not immerse the appliance or any part of it in water or any other liquid. -Avoid knocks or letting the unit fall down. -Remove the battery from the compartment if you are not going to use the scales for a long period of time. -Change the batteries when they run out. Do not mix new batteries with used ones. Only use batteries of the same model or equivalent to those recommended. -The batteries must be fitted in agreement with the correct polarity indicated. -Never place the battery compartment close to a fire or heat source. -Do not throw the batteries into the fire or place the control unit in direct sunlight. -The results of a reading can only be interpreted by a doctor. If you suffer from arrhythmias, the reading results must only be analysed by your doctor. If you have any doubts with respect

to your blood pressure and the reading which are not included in these user instructions, please see your doctor. -The cuff should not be twisted under any circumstances whatsoever. -Do not inflate the cuff with air when it is not in position on the wrist. -Do not attempt to open the unit, or modify the screen components nor the cuff. -The unit is only suitable for measuring the blood pressure of adults. -The unit should not be used on an injured wrist. INSTRUCTIONS FOR USE -Open the battery compartment cover on the under side of the unit and insert two 1.5 V AAA batteries in the battery compartment in keeping with the polarity indicated. -All the icons will appear momentarily on the screen, and then the indication of the month 1, date 1, time 12, and minute 0. -To adjust the date and time, press the M button and the month will begin to flash on the screen. Select the month by pressing S. Once the required month has been selected, press M to set the day, and press the S button once again. Press M to set the hour (12h) and then the S button. Press M once again to set the minutes, and then finally the S button once again to finish. -To go to the normal time press the M button once again and the screen will now show the month, day hour and minute. -To measure your blood pressure you should follow the following steps very carefully: 1 Sit down in a chair in an upright position, and during the measuring of the blood pressure keep still and do not talk. 2 Place the cuff around your wrist and at the same height as your heart, exactly as indicated in the drawing. Do not pull hard on the cuff nor tighten down the cuff on the wrist too much. A watch or clothing that might restrict your blood flow during measurement should be avoided. 3 The unit should be at the same height as your heart to obtain the best reading (please see fig1). 4 Press the START/STOP button. 5 All the icons will show 888 for three seconds and then the current time will be shown on the screen. 6 The blood pressure measuring icon will appear on the screen and the air pressure will automatically increase up to 195 mmhg. In the case of a tendency towards an over high blood pressure, the air pressure will continue increasing to the level necessary to make a measurement. 7 After having increased, the air pressure will then begin to lower gradually. 8 On detecting the heart rate, the pulse icon will start to flash on the screen. 9 After having taken the blood pressure, the systolic and diastolic results and the pulse rate will appear on the screen for one minute and will then automatically disappear. -In the event of interrupting the inflation of the cuff, the process should be stopped by pressing the START/STOP button. -The systolic and diastolic results and the pulse rate readings and also the measurement date will be automatically stored after each reading. -Up to 48 readings can be stored. Thereafter the oldest readings will be automatically deleted from the memory. -To see the memory details, the Recall button should be pressed, and the systolic and diastolic results and the heart rate, and also the time and date of the register of the reading data will appear. The data will disappear after one minute (60 seconds), and to see the following measurements the RECALL button should be pressed again. -To delete all the data that has been memorised, all you have to do is to remove the two batteries and put them back in place immediately. To check that the data has been deleted press the RECALL button. In this case no data will appear on the screen. -Substitute the batteries if the following icon appears on the screen if this is not done no blood pressure measurement can be carried out. Blood pressure classification table: Hypotension

Normal Limit Hypertension Systolic pressure lower 105 mmhg lower 140 mmhg 140-160 mmhg upper 160 mmhg Diastolic pressure lower 60 mmhg lower 90 mmhg 90-95 mmhg upper 95 mmhg ERRORS -If the cuff is put on loosely erroneous readings will be obtained. -If on taking the blood pressure the arm is too high or too low (please see the illustration), for every 15 centimetres difference in height a measurement error 10 mm Hg. will be obtained. People suffering from high blood pressure, diabetes, hepatopathia, artery diseases or blood circulation problems should take special care when taking their blood pressure. SCREEN ICONS CLEANING AND STORAGE -Do not use abrasive detergents or products that may damage the appliance. -NEVER IMMERSE THE APPLIANCE IN WATER OR ANY OTHER LIQUID. -Use a damp cloth or sponge to clean the unit. -Please put the unit away in its case after use. -Do not expose to extremely low temperatures (under 20 C) or high temperatures (-70 C). -We recommend that technical measurement servicing of this unit is carried out every 2 years. By means of the oscillometric measurement method, the systolic and diastolic pressure and the pulse rate are measured in people. TECHNICAL SPECIFICATIONS Measurement method: oscillometric. Measurement range: pressure 0-300 mmhg. Pulse: 40-199 pulsations/minute.

Measurement precision: pressure +/- 3 mmhg, pulse +/- 5%. Approximate pressure: automatic re-inflating system. Pressure setting: automatic pressure setting by means of a pump. Pressure reduction: automatic pressure reducing valve system. Outlet valve: automatic outlet valve. LCD screen. Memory: 48 lines of data can be stored. Measurements: length 70 x width 72 x height 29 mm. Weight: approximately 133 g (batteries included). Cuff size: for a wrist perimeter of approximately from 135 to 195 mm. Permitted working temperature: +10 C to +40 C, <85% relative air humidity. Storage temperature: -20 C to +70 C, <85% relative air humidity. Power supply: two 1.5 V AAA type alkaline batteries. Battery life: for approximately 250 measurements. 3V DC (2XAAA 1,5V) This device conforms to the safety requirements and provisions of directives 93/42/EC on medical appliances. PROTECTION OF THE ENVIRONMENT DIRECTIVE 2002/96/EC This product has been designed and manufactured with high quality materials and components that can be recycled and reused. When you see the symbol of a crossed out litter bin on wheels next to a product, this means that the product conforms to the European Directive 2002/96/EC. Please obtain information about the local recycling system for electric and electronic products. Follow the local rules and do not dispose of used products by throwing them in the normal bins at home. Proper recycling of your used product will help avoid negative impacts on the environment and people s health. This blood pressure monitor complies with the EC Directive and bears the CE mark. This blood pressure monitor also complies with mainly following standards, (included but not limited). Safety standard: EN 60601-1 Medical electrical equipment part 1: General requirements for safety. EMC standard: EN 6061-1-2 Medical electrical equipment part 1-2: General requirements for safety - Collateral standard: Electromagnetic compatibility - Requirements and tests. Performance standards: EN 1060-1 Non-invasive sphygmomanometers - General requirements. EN 1060-3 Non-invasive sphygmomanometers - Supplementary requirements for electromechanical blood pressure measuring systems. EN 1060-4 Non-invasive sphygmomanometers - Test procedures to determine the overall system accuracy of automated non-invasive sphygmomanometers. Important/Caution/Note! Read the operating instructions. Consult instructions thoroughly before use. BF Classification: -Internally powered equipment. -BF type applied part. -IPX0 -Not suitable for use in presence of flammable anesthetic mixture with air or with Oxygen or nitrous oxide. -Continuous operation with short-time loading.

To avoid inaccurate results caused by electromagnetic interference between electrical and electronic equipments, do not use the device near a mobile phone or microwave oven. 1. Please rest for at least 5~10 minutes before taking the measurement. 2. To allow your blood vessels to return to the condition prior to taking the measurement, please wait at least 3~5 minutes between measurements. You may need to adjust the wait time according to your personal physiological situation. 3. If you have one of the circulatory problems as arteriosclerosis, diabetes, liver disease, kidney disease, severe hypertension, peripheral circulation..., please consult your doctor or healthcare professional before using the devices. Discard the used product to the recycling collection point according to local regulations.