UIB30 and UIB30H Sealed Inverted Bucket Steam Traps for use with Pipeline Connectors

Similar documents
MST21 Stainless Steel Balanced Pressure Thermostatic Steam Trap

HM and HM34 Inverted Bucket Steam Traps Installation and Maintenance Instructions

DF1 and DF2 Diffusers

TSS21 Sealed Thermostatic Steam Tracer Trap

Spiratec ST14, ST16 and ST17 Sensor Chambers and sensors

Fig 12, Fig 14HP, Fig 16, Fig 16HP and Fig 16L Strainers

S and SF Inverted Bucket Steam Traps

BT6HC Hygienic Sanitary Balanced Pressure Steam Trap for High Capacity and CIP/SIP Applications

Fig 1, Fig 12, Fig 13, Fig 14HP, Fig 16, Fig 16HP and Fig 16L Strainers

PV4 and PV6 Piston Valves

IFTGS14 Ball Float Steam Trap ½" and ¾" with Integral Spiratec Sensor

S1, S2, S3, S5, S6, S7, S8, S12 and S13 Separators

TA10A and TA10P Steam Tracing Temperature Control Valves Installation and Maintenance Instructions

DCV10 Stainless Steel Disc Check Valve for use with Condensate Pumps

TP1 and TP2 Temporary Cone Shaped Strainers

SCA Series Inverted Bucket Steam Traps

KBV21i and KBV40i Key Operated Boiler Blowdown Valves Installation and Maintenance Instructions

FTGS14 Ball Float Steam Trap DN15 (½") to DN25 (1")

AVC32 Carbon Steel Air Vent for Steam Systems

MSC-P and MSC-N Manifolds for Steam Distribution and Condensate Collection

Dri-Line Mk3 Monnier Compressed Air Drain Trap

KBV21i and KBV40i Air Actuated Boiler Blowdown Valves

AVM7 Stainless Steel Thermostatic Air Vent

AE14 Automatic Air Vents for Liquid Systems Installation and Maintenance Instructions

TDC46M, TDS46M and UTDS46M Thermodynamic Steam Traps with Maintainable Seat Installation and Maintenance Instructions

Dri-Line Mk2 Spirax-Monnier Compressed Air Drain Trap

UBP32 Sealed Balanced Pressure Thermostatic Steam Trap for use with PC_ Pipeline Connectors Installation and Maintenance Instructions

CVS10 Sanitary Check Valves

DCV1, DCV3 and DCV3LT Disc Check Valves Installation and Maintenance Instructions

BTM7, BTS7 and BTS7.1 Stainless Steel Thermostatic Clean Steam Traps

CA44, CA44S, CA46 and CA46S Air and Gas Traps

S1, S2, S3, S5, S6, S7, S8, S12 and S13 Separators Installation and Maintenance Instructions

USM21 Sealed Bimetallic Steam Trap for use with Pipeline Connectors Installation and Maintenance Instructions

CP10 Sensor Installation and Maintenance Instructions

DCV6 Disc Check Valve

Airodyn, BRair and BRoil Compressed Air Drain Traps

Fig 3, 7, 33, 34, 34HP, 36, 36HP, 37, 3616 and Fig 3716 Flanged Strainers

TD62LM and TD62M Thermodynamic Steam Traps with Replaceable Seats

PC10HP Pipeline Connector (ASME 600)

CA10S, CA14 and CA14S Air and Gas Traps

AVS32 Stainless Steel Air Vent for Steam Systems Installation and Maintenance Instructions

FV Flash Vessel Installation and Maintenance Instructions

Fig 7, 33, 33.1, 34, 34HP, 36, 36HP, 37, 3616 and Fig 3716 Flanged Strainers Installation and Maintenance Instructions

TD62LM and TD62M Thermodynamic Steam Traps with Replaceable Seats Installation and Maintenance Instructions

BPT13 Balanced Pressure Thermostatic Steam Traps

MF2M Monnier Miniature Compressed Air Filter

AE30 Automatic Air Eliminators / Air and Gas Vents for Liquid Systems

SA121, SA122, SA123, SA128 and SA1219 Self-acting Temperature Control Systems (Dial Adjustment)

M33F ISO, M33S ISO and M33V ISO Ball Valves Installation and Maintenance Instructions

CS10-1 Stainless Steel Clean Steam Separator

M10HTi ISO Tobacco Ball Valve Screwed, SW, BW and Flanged versions

Manual Actuated Boiler Blowdown Valves

SA121, SA122, SA123, SA128 and SA1219 Self-acting Temperature Control Systems (Knob Adjustment)

BT6-B Sanitary Balanced Pressure Thermostatic Steam Trap

FT16 Ball Float Steam Trap Installation and Maintenance Instructions

IX1 Spirax-Monnier International Compressed Air Filter Installation and Maintenance Instructions

FT53, IFT53, FT54, IFT54, FT57 and IFT57 Ball Float Steam Traps - DIN

ML3M Monnier Miniature Compressed Air Lubricator

TD45 Thermodynamic Steam Trap Installation and Maintenance Instructions

BCV31 DN40 - Blowdown Control Valve

APT14, APT14HC and APT14SHC Spares 2

SRV66 Sanitary Pressure Reducing Valve

BDV1 and BDV2 Blowdown / Depressurisation Valves

MFP14-PPU (Vented) Automatic Packaged Pump Units

Thermocirc Installation and Maintenance Instructions

SRV2S Pressure Reducing Valve

Spirax SafeBloc TM DBB3 Double Block and Bleed Bellows Sealed Stop Valve. 1. Safety information. 2. General product information. 3.

BTD52L Thermodynamic Steam Trap Installation and Maintenance Instructions

TD10, TD52M and TD259 Thermodynamic Steam Traps Installation and Maintenance Instructions

AE50S Automatic Air and Gas Vent for Liquid Systems Installation and Maintenance Instructions

FT43, FT44, FT46 and FT47 Ball Float Steam Traps Installation and Maintenance Instructions

A3S Bellows Sealed Stop Valve Installation and Maintenance Instructions

TW Temperature Control Valve

CA16 and CA16S-14 Air and Gas trap Installation and Maintenance Instructions

SA Control Valve types: BM, BMF, BX, SB, NS, KA, KB, KC (Normally open) BMRA, BMFRA, BXRA, SBRA, NSRA, KX, KY (Normally closed)

Spirax Compact FREME Flash Recovery Energy Management Equipment

M70i ISO and M80i ISO Stainless Steel Ball Valves for Sanitary Systems Installation and Maintenance Instructions

BCV31 DN20 - Blowdown Control Valve

Fig 1, Fig 12, Fig 13, Fig 14, Fig 16 and Fig 16L Strainers Installation and Maintenance Instructions

PC3000, PC3001 and PC4000, PC4001 Pipeline Connectors

BSA6T and BSA64T Stainless Steel Bellows Sealed Stop Valves Installation and Maintenance Instructions

BRV71 and BRV73 Pressure Reducing Valves

FTC62 and FTS62 Ball Float Steam Traps Installation and Maintenance Instructions

MPC1M, MPC2M and MPC2AM Monnier High Efficiency Compressed Air Filter / Regulators

1. General safety information. 2. General product information. 3. Installation. 4. Commissioning. 5. Operation. 6. Maintenance. 7.

M45 ISO Ball Valve DN25 to 150 Installation and Maintenance Instructions

Type 130 and HL10 'Safeguard High Limit Control' Installation and Maintenance Instructions

Vane Flow Switches Colima FLU Series

BCVi43 Blowdown Control Valve

M111 Spiraflo Transducer

QuickHeat TM Packaged Heat Exchanger Solutions

IP2M, IP2AM and IP2DM Monnier International Compressed Air Filter/ Regulators

LP31 Level Probe. 1. Safety information. 2. General product information. 3. Installation. 4. Wiring. 5. Maintenance

CA46S Austenitic Stainless Steel Air and Gas Trap DN40 and DN50

PC3_ and PC4_ Pipeline Connectors

BDV60 Blowdown Vessel Installation and Maintenance Instructions

STERI-TROL Clean Service 'S' Series Two-port Control Valves DN15 (½") to DN100 (4")

SRV461S and SRV463S Stainless Steel Direct Acting Pressure Reducing Valves

BSA and BSAT Bellows Sealed Stop Valves Installation and Maintenance Instructions

PTF4 Pivotrol Pump (patented) version Dual Mechanism - Pressure Powered Pump

Transcription:

1130050/4 IM-P113-02 ST Issue 4 UIB30 and UIB30H Sealed Inverted Bucket Steam Traps for use with Pipeline Connectors Installation and Maintenance Instructions 1. Safety information 2. General product information UIB30 and UIB30H 3. Installation 4. Commissioning 5. Operation 6. Maintenance 7. Spare parts Copyright 2013 IM-P113-02 ST Issue 4 1 Printed in GB

2 IM-P113-02 ST Issue 4

1. Safety information Safe operation of these products can only be guaranteed if they are properly installed, commissioned, used and maintained by qualified personnel (see Section 1.11 ) in compliance with the operating instructions. General installation and safety instructions for pipeline and plant construction, as well as the proper use of tools and safety equipment must also be complied with. Warning The inner and outer gaskets used when installing / maintaining the UIB to a PC_ pipeline connector contain thin stainless steel support rings which may cause physical injury if not handled and disposed of carefully. 1.1 Intended use Referring to the Installation and Maintenance Instructions, product marking and Technical Information Sheet, check that the product is suitable for the intended use / application. The UIB30 and UIB30H comply with the requirements of the European Pressure Equipment Directive 97 / 23 / EC and fall within category 'SEP'. It should be noted that products within this category are required by the Directive not to carry the mark. i) The UIB30 and UIB30H have been specifically designed for use on steam, air or condensate / water which are in Group 2 of the above mentioned Pressure Equipment Directive. The products use on other fluids may be possible but, if this is contemplated, Spirax Sarco should be contacted to confirm the suitability of the product for the application being considered. ii) Check material suitability, pressure and temperature and their maximum and minimum values. If the maximum operating limits of the product are lower than those of the system in which it is being fitted, or if malfunction of the product could result in a dangerous overpressure or overtemperature occurrence, ensure a safety device is included in the system to prevent such over-limit situations. iii) Determine the correct installation situation and direction of fluid flow. iv) Spirax Sarco products are not intended to withstand external stresses that may be induced by any system to which they are fitted. It is the responsibility of the installer to consider these stresses and take adequate precautions to minimise them. v ) R e m o v e p r o t e c t i o n c o v e r s f r o m a l l c o n n e c t i o n s a n d p r o t e c t i v e fi l m f r o m a l l name-plates, where appropriate, before installation on steam or other high temperature applications. 1.2 Access Ensure safe access and if necessary a safe working platform (suitably guarded) before attempting to work on the product. Arrange suitable lifting gear if required. 1.3 Lighting Ensure adequate lighting, particularly where detailed or intricate work is required. 1.4 Hazardous liquids or gases in the pipeline Consider what is in the pipeline or what may have been in the pipeline at some previous time. Consider: flammable materials, substances hazardous to health, extremes of temperature. IM-P113-02 ST Issue 4 3

1.5 Hazardous environment around the product Consider: explosion risk areas, lack of oxygen (e.g. tanks, pits), dangerous gases, extremes of temperature, hot surfaces, fire hazard (e.g. during welding), excessive noise, moving machinery. 1.6 The system Consider the effect on the complete system of the work proposed. Will any proposed action (e.g. closing isolation valves, electrical isolation) put any other part of the system or any personnel at risk? Dangers might include isolation of vents or protective devices or the rendering ineffective of controls or alarms. Ensure isolation valves are turned on and off in a gradual way to avoid system shocks. 1.7 Pressure systems Ensure that any pressure is isolated and safely vented to atmospheric pressure. Consider double isolation (double block and bleed) and the locking or labelling of closed valves. Do not assume that the system has depressurised even when the pressure gauge indicates zero. 1.8 Temperature Allow time for temperature to normalise after isolation to avoid the danger of burns. 1.9 Tools and consumables Before starting work ensure that you have suitable tools and /or consumables available. Use only genuine Spirax Sarco replacement parts. 1.10 Protective clothing Consider whether you and / or others in the vicinity require any protective clothing to protect against the hazards of, for example, chemicals, high / low temperature, radiation, noise, falling objects, and dangers to eyes and face. 1.11 Permits to work All work must be carried out or be supervised by a suitably competent person. Installation and operating personnel should be trained in the correct use of the product according to the Installation and Maintenance Instructions. Where a formal 'permit to work' system is in force it must be complied with. Where there is no such system, it is recommended that a responsible person should know what work is going on and, where necessary, arrange to have an assistant whose primary responsibility is safety. Post 'warning notices' if necessary. 1.12 Handling Manual handling of large and / or heavy products may present a risk of injury. Lifting, pushing, pulling, carrying or supporting a load by bodily force can cause injury particularly to the back. You are advised to assess the risks taking into account the task, the individual, the load and the working environment and use the appropriate handling method depending on the circumstances of the work being done. 4 IM-P113-02 ST Issue 4

1.13 Residual hazards In normal use the external surface of the product may be very hot. If used at the maximum permitted operating conditions the surface temperature of the product may reach temperatures up to 425 C (797 F). Many products are not self-draining. Take due care when dismantling or removing the product from an installation (refer to Maintenance instructions ). 1.14 Freezing Provision must be made to protect products which are not self-draining against frost damage in environments where they may be exposed to temperatures below freezing point. 1.15 Disposal Unless otherwise stated in the Installation and Maintenance Instructions, this product is recyclable and no ecological hazard is anticipated with its disposal providing due care is taken. 1.16 Returning products Customers and stockists are reminded that under EC Health, Safety and Environment Law, when returning products to Spirax Sarco they must provide information on any hazards and the precautions to be taken due to contamination residues or mechanical damage which may present a health, safety or environmental risk. This information must be provided in writing including Health and Safety data sheets relating to any substances identified as hazardous or potentially hazardous. IM-P113-02 ST Issue 4 5

2. General product information 2.1 General description The UIB30 and UIB30H are sealed inverted bucket steam traps for either horizontal or vertical installation (with the cover hanging downwards). The UIB30H is designed for higher capacities. When installed with a suitable pipeline connector (available separately from Spirax Sarco) the UIB can easily and simply be removed without breaking into the pipeline, thus speeding up trap replacement with minimal system downtime. Pipeline connectors are available with screwed, socket weld and flanged end connections. Standards This product fully complies with the requirements of the European Pressure Equipment Directive 97 / 23 / EC. Certification This product is available with certification to EN 10204 3.1. Note: All certification / inspection requirements must be specified at the time of order placement. Note: For additional information see Technical Information Sheet: TI-P113-01 for the UIB30 and UIB30H. 1 Cover * Optional extras The cover (1) is also available with a threaded drain plug and connection (13 + 14) in " NPT, ½" NPT or ½" BSP to allow for drainage. If this 13 * option is required it must b e s p e c i fi e d a t t h e t i m e 14 * of order placement. Fig. 1 UIB30 2.2 Sizes and pipe connections The UIB30 and UIB30H can be fitted to a variety of different pipeline connectors including:- PC10HP Straight connector ASME 600 (see TI-P128-10) PC20 Connector with 'Y' type strainer ASME 300 (see TI-P128-15) PC30 Connector with one piston isolation valve ASME 600 (see TI-P128-02) PC40 Connector with two piston isolation valves ASME 600 (see TI-P128-03) See the relevant Technical Information Sheet as listed above for details of the connections available on pipeline connectors. 6 IM-P113-02 ST Issue 4

2.3 Pressure/temperature limits Temperature C Pressure psi g 0 100 200 300 400 500 600 700 425 400 300 200 100 Steam saturation curve 0-29 0 10 20 30 40 49.6 Pressure bar g The product must not be used in this region. 700 600 500 400 300 200 100 0 Note: The model of pipeline connector and connections selected will dictate the maximum operating pressure and temperature of the complete assembly. Consult the specified Technical Information Sheet for this information (see Section 2.2). Body design conditions ASME 300 PMA Maximum allowable pressure 49.6 bar g @ 38 C (720 psi g @ 100 F) TMA Maximum allowable temperature 425 C @ 28 bar g (800 F @ 405 psi g) Minimum allowable temperature -29 C (-20.2 F) PMO Maximum operating pressure for saturated steam service 32 bar g (464 psi) TMO Maximum operating temperature 425 C @ 28 bar g (800 F @ 405 psi g) Minimum operating temperature 0 C (32 F) UIB30/4 UIB30H/5 30 bar (435 psi) UIB30/5 UIB30H/6 20 bar (290 psi) UIB30/6 UIB30H/7 12 bar (174 psi) Maximum PMX differential pressure UIB30/7 UIB30/8 UIB30H/8 UIB30H/10 8.5 bar 5 bar 4 bar (123 psi) (72.5 psi) (58 psi) UIB30/10 2.5 bar (36 psi) UIB30H/12 2 bar (29 psi) UIB30/12 1.5 bar (22 psi) Designed for a maximum cold hydraulic test pressure of: 75 bar g (1 088 psi g) Temperature F IM-P113-02 ST Issue 4 7

3. Installation Note: Before actioning any installation observe the 'Safety information' in Section 1. Referring to the Installation and Maintenance Instructions, name-plate and Technical Information Sheet, check that the product is suitable for the intended installation: 3.1 Check materials, pressure and temperature and their maximum values. If the maximum operating limit of the product is lower than that of the system in which it is being fitted, ensure that a safety device is included in the system to prevent overpressurisation. 3.2 Determine the correct installation situation and the direction of fluid flow. 3.3 Remove protection covers from all connections and protective film from all name-plates, where appropriate, before installation on steam or other high temperature applications. 3.4 If the trap has been supplied with a drain plug and is to be replaced with a drain device, this should be completed before fixing the trap to the pipeline connector. When removing the plug or assembling a drain device, suitable spanners must be used on the drain connection flats (13) and the drain plug flats (14). 3.5 The UIB can be installed on any pipeline connector. See separate Installation a n d M a i n t e n a n c e I n s t r u c t i o n s f o r S p i r a x S a r c o p i p e l i n e c o n n e c t o r s ( I M - P 12 8-0 6, IM-P128-11 and IM-P128-13). Ensure that both gaskets are clean and undamaged and that the transfer holes are clear. Place the UIB body against the connector gasket face, ensuring that the trap itself is vertical so the bucket always rises and falls in a vertical plain. A p p l y a s u i t a b l e a m o u n t o f a n t i - s e i z e t h r e a d l u b r i c a n t t o t h e t h r e a d s o f t h e c o n n e c t o r screws (10). Tighten the screws finger tight until the mating gasket faces are in parallel, intimate contact. Tighten the screws evenly and gradually to the recommended torque value (see Table 1). Open isolation valves slowly until normal operating conditions are achieved. 3.6 Inverted bucket steam traps do not permit rapid release of air. On process applications, in particular, this can lead to slow warm-up times and waterlogging of the steam space. A separate external air vent is therefore required in parallel to vent air efficiently. Any bypass should be positioned above the trap. If it is below, and is leaking or left open, the waterseal could be blown away leading to steam wastage. Where inverted bucket traps are fitted in exposed conditions the possibility of freezing damage can be reduced by thermal insulation. 3.7 The inlet of the trap should be below the drain point of the plant being drained, so that a waterseal can be maintained around the open end of the bucket. When installed in a horizontal pipeline a small drop leg should precede the trap - typically 150 mm (6"). 3.8 Where the trap discharges into a closed condensate return system or where there is a lift at the trap, a check valve should be fitted downstream of the trap. 3.9 If the trap has to be installed at a higher point than the drainage point, then a small bore riser into a 'U' seal should be used. A check valve should be fitted before the trap to prevent the loss of the internal waterseal. 3.10 If the trap is installed on a superheated steam system application, then a non return valve should be fitted on the trap inlet, to prevent the trap from losing its waterseal. Priming of the trap with water may be required before commissioning. 3.11 Check for leaks. Note 1: If the trap is to discharge to atmosphere ensure it is to a safe place, the discharging fluid may be at a temperature of 100 C (212 F). Note 2: On all blast discharge steam traps check valves and sight glasses must be installed at least 1 metre (3 ft) downstream of the trap. 8 IM-P113-02 ST Issue 4

UIB in horizontal a pipeline UIB in vertical a pipeline Fig. 2 10 Pipeline connector Fig. 3 UIB30 and UIB30H Inverted bucket steam trap 1 Cover * Optional extras The cover (1) is also available with a threaded drain plug and connection (13 + 14) in " NPT, ½" NPT or ½" BSP to allow for drainage. If this 13 * option is required it must be specified at the time of 14 * order placement. Table 1 Recommended tightening torques or Item Part N m (lbf ft) mm 10 Connector screws 9 /16" 30-35 (22-26) IM-P113-02 ST Issue 4 9

4. Commissioning After installation or maintenance ensure that the system is fully functioning. Carry out tests on any alarms or protective devices. 5. Operation As condensate reaches the trap it forms a water seal inside the body. The weight of the bucket keeps the valve off its seat. Condensate can then flow around the bottom of the bucket and the trap. Under low load or superheat conditions the trap may need to be 'primed' with water before system start-up. When steam enters the underside of the bucket it gives it buoyancy and the bucket rises allowing the valve to seat and stop steam escaping. The bucket will lose its buoyancy as the enclosed steam condenses due to radiation losses and steam escapes through the vent hole. Once this happens the weight of the bucket will pull the valve off its seat and the cycle is then repeated. Any air reaching the trap will also give the bucket buoyancy and close the valve preventing condensate flow. The small vent hole in the bucket will bleed air into the top of the trap. The vent hole is of small diameter to reduce steam loss and will consequently vent air very slowly. Under most conditions the trap will discharge condensate with a blast type action. Under low load and / or low pressure applications the discharge may tend to 'dribble'. Condensate is discharged at steam temperature consequently due care must be given to the site of the discharge. 6. Maintenance Note: Before actioning any maintenance programme observe the 'Safety information' in Section 1. Warning The inner and outer gaskets used when installing / maintaining the UIB to a PC_ pipeline connector contain thin stainless steel support rings which may cause physical injury if not handled and disposed of carefully. 6.1 General information Before undertaking any maintenance on the trap it must be isolated from both the supply line and return line and any pressure allowed to safely normalise to atmosphere. The trap should then be allowed to cool. When reassembling, ensure that all joint faces are clean. 6.2 Replacement of the trap unit: - Ensure that the correct tools and necessary protective equipment are used at all times. - Replacement of the trap unit is achieved by removing the two connector screws (10) and removing the trap. - The new trap unit should be positioned against the connector gasket face and apply a suitable amount of anti-seize thread lubricant to the threads of the connector screws. - Tighten screws finger tight and ensure that the trap body is parallel to the connector. - Tighten the screws evenly and gradually to the recommended torque (see Table 1). - Open isolation valves slowly until normal operating conditions are achieved. - Check for leaks. 10 IM-P113-02 ST Issue 4

7. Spare parts The UIB and UIB30H are sealed non-maintainable trap units. No internal spares are available. The spares which are available are shown in heavy outline. Parts shown in a broken line are not supplied as spares. Available spares Connector screws and gasket set 10, 11, 12 How to order spares Always order spare parts by using the description given in the column headed 'Available spares' and state the size, model no. and pressure rating of the trap. Examples: 1 - Connector screw and gasket set for a Spirax Sarco UIB30 sealed stainless steel bucket steam trap (for use with pipeline connectors). UIB30 inverted bucket steam trap Fig. 4 Pipeline 10 connector 12 11 Table 1 Recommended tightening torques or Item Part N m (lbf ft) mm 10 Connector screws 9 /16" 30-35 (22-26) Table 2 Dimensions of the optional drain connection - See Fig. 1 or Item Part mm 13 Drain connection 32 A / F 18 A / F " NPT 14 Drain plug 22 A / F ½" NPT 22 A / F ½" BSP IM-P113-02 ST Issue 4 11

12 IM-P113-02 ST Issue 4