valves Total Control.

Similar documents
Installation, commissioning and servicing instructions

Installation, commissioning and servicing instructions

Tempering valve for solar and instantaneous applications Installation, commissioning and servicing instructions 2522HP series

Installation, commissioning and servicing instructions

Installation, commissioning and servicing instructions

BASIN AND WALL MIXER INSTALLATION INSTRUCTIONS

553 Series.

TECHNICAL CATALOGUE PRESSURE REDUCING VALVES EUROPRESS

TECHNICAL CATALOGUE PRESSURE REDUCING VALVES EUROPRESS

Installation, commissioning and servicing instructions

HERZ-Motorised flow controler

MZX. Three-Port Seat Valves SPECIFICIATIONS AND GUIDE TO SELECTION

bathrooms.com Concentric Thermostatic Shower Mixers Cleaning and Care Installation Manual Contents

Pressure regulator for water

Reduce pressure zone device suitable for high and medium hazard rated applications BSP screwed connections

PRICE LIST. November GST Exclusive

DN 1/2" to 2" Female BSP + 0 C C Max Pressure : 16 Bars Specifications : Stainless steel removable filter Female / Female With draining valve

High Performance BSP Dial Up Pattern Pressure Reducing Valve

VALVCHEQ BACKFLOW PREVENTERS FIGURE RP03

CASH VALVE TYPE KP BACK PRESSURE VALVES

POP Safety Valve. POP Safety Valve INTRODUCTION DEFINITIONS

M03 WUNDATRADE. Heat Pump Manifold. Before you start: Check the contents. Optional. ...a division of WUNDA GROUP PLC

System Pressure Manager Standard & System Pressure Manager Plus

CALEFFI. Ball zone valves. series /03 GB

SYSTEM REGULATING VALVES PRESSURE RELIEF VALVE - SRV BRASS & S/STEEL ADJUSTABLE

Mainsboost Installation, Operation & Maintenance Instructions

Dynamic Valve Type RA-DV Pressure Independent Radiator Valve

DS MZ, MZF, MJF THREE-PORT SEAT VALVES

Function. Code Automatic filling units with pressure gauge connection Size 1/2 Code Automatic filling units with pressure gauge Size 1/2

TECHNICAL DATA. Q = C v P S

Installation Guide - C01202 & C01203 Thermostatic Mixing Valve TMV2

THERMOSTATIC MIXING VALVES

HORNE 20 THERMOSTATIC MIXING VALVE TYPE H-2003

Pressure Reducing Valve DMV 755

D05 Pressure Regulating Valves

RA-N radiator valves with integrated presetting and self-sealing tailpiece

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

Intamix Thermostatic Mixing Valve

Technote. Frese PV-SIGMA Compact Dynamic Pressure and Flow Regulation. Description. Application. Operation. Features. Benefits.

BTV. Internally threaded 2-way control valve. Flow characteristics. Function

THE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv)

C 10 Pressure Reducing Valve

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

Differential pressure and flow controller (PN 16) AVPQ - return mounting, adjustable setting

CALEFFI. Pre-adjustable pressure reducing valves with self-contained cartridge series 01085/17 GB. replaces 01085/14 GB

How to Order RM0 0 Z. IN/OUT fitting type Metric size Inch size Straight Elbow Straight Elbow Straight Elbow Straight Elbow ø ø ø ø ø ø ø ø ø/ ø/ ø/ ø

TECHNICAL DATA. Q= Cv S

776 Cryogenic Safety Valve

Chrome plated radiator valves type RA-NCX and lockshield valves type RLV-CX

Pressure reduction controller (PN 16, 25, 40)

756 Safety Relief Valves

Reduce pressure zone device suitable for high and medium hazard rated applications Flanged end connections

Twin & Triple Control Concealed Thermostatic Shower Valve

DS05C,D,G Dial Set Pressure Regulating Valves

VALVCHEQ BACKFLOW PREVENTERS FIGURE RP03

Electronic Single and Twin Pump System Pressure Managers

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

HAYWARD FLOW CONTROL Series PBV Back Pressure Valve and Series RPV Pressure Relief Valve INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS

Installation, commissioning and servicing instructions. General

ACCREDITED. Technical specifications series

CALEFFI. Inclined pressure reducing valves series 01024/17 GB. replaces 01024/14 GB

APEX-COMMERCIAL-CATALOGUE Commercial Plumbing. Plumbing control valves for non-residential applications. Apex.com

REVERSE OSMOSIS INSTALLATION Watermark 4 Stage

Overview of types. T5-R B2/R B2 en v Subject to changes 1 / 4. k vs (Sequence 2)

Automatic balancing valves ASV

Pressure Independent Control Series

Filling valves AL, ALM Series Automatic filling units ALOMDIW, ALOMDNW Series

SEQUENTIAL SHOWER VALVE INSTRUCTION MANUAL PLEASE LEAVE THIS MANUAL WITH THE END USER

Direct on Mains (DOM) Unvented Kit Components Literature

Versions. Benefits. Balancing DN15-32 DN40 DN50 DN15, DN20, DN25, DN32, DN40, DN50. Dimensions

Standard Specifications

29 SERIES - SAFETY VALVE

URINAL FLUSHING SYSTEM WITH MICROWAVE SENSOR

Automatic balancing valves ASV

Premium Series. Economical Price & Reliable Performance. High Quality. Rust-Resistant. Long Life. Tamper-Resistant locking Screw.

Differential pressure controller (PN 16) AHP - return mounting, adjustable setting

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified

Art PRESSURE REDUCER

Series V47 Temperature Actuated Modulating Valves

Operating Manual. R280 Pressure regulator made of brass. 1. Intended Use

36E DSI and HSI Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

DUAL CHECK VALVES 2NV20-20F PRODUCT CODES OPERATION LOW HAZARD RATING. 20mm FEATURES APPLICATION SPECIFICATION STATEMENT DESCRIPTION

Accessories for Potable Water Installations

Description Pressure range Connection thread Device Page

differential pressure regulating valve - threaded

IMPORTANT PLEASE READ BEFORE COMMENCING INSTALLATION

Bar valve with fixed shower head Installation guide

Pressure relief valve DHV 716 set range: 0,5-10,0 bar

Regulator from 1800 B series

D05T Compact Design Pressure Regulating Valves

TECHNICAL DATA. Page 1 of 12

Horne Engineering Ltd

Pre-adjustable pressure reducing valves

Overview of types. Technical data. Safety notes

TEC 1/2 3/4 DN A B C 32,25 32,25 F Kg/cm 2 bar LBS - psi

Presetting Valve Type RA-N with Flange Connection

RELIABLE PROTECTION FOR A WIDE RANGE OF RESIDENTIAL, COMMERCIAL AND INDUSTRIAL APPLICATIONS. water pressure reducing valves

STAD Series. Balancing and control valves. Technical Data Sheet. WattsIndustries.com

Technical data sheet. Type overview. Technical data. Safety notes. T5-R2.. Open-close en v Subject to changes 1 / 3

Transcription:

valves Total Control.

Contents Tempering Valves 2 Thermostatic Mixing Valves 4 Non-Return Isolating Valves 5 Pressure Reducing Valves 6 Pressure Limiting Valves 8 ackflow Prevention Valves 9 Pressure & Temperature Relief Valves 1 Expansion Control Valves 11

Tempering Valves C F D Standard Tempering Valve 15 MM 2 MM E 15mm 2mm 62.5mm 69mm C 125mm 138mm D 97.5mm 133mm E 48.5mm 84mm F 49mm 49mm C F D High Performance Solar 15 MM 2 MM E 15mm 2mm 142mm 164mm C 166mm 194mm D 44mm 113mm E 74mm 75mm F 63mm 62mm Optional Copper Olive and Nuts also included for horizontal connections. 2 Tomson Valves

1 2 5 3 4 6 7 8 9 STNDRD TEMPERING VLVE Recommended use The tempering valve is used to regulate the set temperature of mixed hot and cold water even when variations occur in the water supply conditions for storage gas and electric hot water units. HIGH PERFORMNCE SOLR Recommended use The tempering valve is used to regulate the temperature of mixed hot and cold water even when variations occur in the water supply conditions for continuous flow, solar and heat pump hot water units. Reece Code and Description 1921 TOMSON STD TEMPERING VLVE 15MM 19211 TOMSON STD TEMPERING VLVE 2MM Specifications Temperature control: ±3 C Minimum cold inlet temperature: 5 C Maximum cold inlet temperature: 3 C Minimum hot inlet temperature: 55 C Maximum hot inlet temperature: 85 C Maximum working pressure :14 kpa Minimum flow rate for stable operation: 4 l/min 1 year S432.2 LN:WMK2466 Temperature set: Must be commissioned on site to achieve desired temperature. Prior to the installation of the Tomson valve, the system must be checked to ensure that the system operating conditions fall within the recommended operating range of the valve, i.e. verify supply temperatures, supply pressures, risk assessments, etc. Valve body: DZR alloy Reece Code and Description 19216 TOMSON HPS TEMPERING VLVE 15MM 19217 TOMSON HPS TEMPERING VLVE 2MM Specifications Hot Temperature Supply Range: 55 C 99 C Cold Temperature Supply Range: 5 C 3 C djustable Temperature Range: Full Cold 55 C Maximum Supply Pressure: 16kPa Maximum supply pressure variation: 2:1 Minimum Temperature differential (between hot supply and outlet temperature): 1 C Flow rate, minimum: 4 L/min Flow rate, maximum @ 3kPa: 36 L/min 2 years S432.2 LN:WMK1593 Valve must be commissioned on site to achieve desired temperature. Prior to the installation, the system must be checked to ensure that the system operating conditions fall within the recommended operating range of the valve, i.e. verify supply temperatures, supply pressures, risk assessments, etc. Surface Finish: Nickel plated body with un-plated fittings Flow Characteristics Flow Characteristics Pressure Drop - kpa P (kpa) 1 9 8 7 6 5 45 4 35 3 2 2 18 16 14 12 1 9 8 7 6 5 4,5 3,5 4 3 2,5 2 1,8 1,6 1,4 1,2 1 1,2 1,4 1,6 1,8 2,5 3,5 4,5 1 12 Ø15mm 14 16 18 2 Ø2mm 25 3 35 4 45 5 Pressure Drop (kpa) 3 25 2 15 1 5 5 1 15 2 3 35 4 HP DN2 HP DN15 Flow rate - Litres per minute Q (l/min) Flow rate Litres per minute Tomson Valves 3

Thermostatic Mixing Valves Recommended Use The thermostatic mixing valves are a safe and reliable way to control water temperature. Reece Code & Description 19296 TOMSON TMV 15MM 19297 TOMSON TMV SERVICE KIT 19298 TOMSON TMV WLL RCKET 19299 TOMSON TMV STINLESS STEEL OX Pressure Loss with alanced Inlet Pressures (kpa) 35 3 25 2 15 1 5 1 2 3 4 Mixed Outlet Flow rate - Litres per minute Conditions Hot Temp Supply Range: 55 C - 9 C Cold Temp Supply Range: 5 C - 3 C Max. Supply Pressure: 16kPa Pressure Loss Ratio: 1:1 (max) Operating Specifications ccuracy: ±2ºC Operating Temperature Range: 35ºC - 5ºC Factory Set Temperature Range: 43ºC ±2ºC Min. Temperature Differential (hot supply and outlet temp): 1 C Min. Flow rate: 4 L/min 2 Year S432.1-25 Lic. No. WMK1593 NSW Health pproved Must be fitted and installed in accordance with S/NZS 35.1. Nickel plated body and fittings. Chrome plated ½ nuts Thermostatic Mixing Valve C C 15 MM 121mm 52mm 7mm 4 Tomson Valves

Non-Return Isolating Valves Recommended Use To prevent contamination of mains supply and protection from isolation of water. FLOW CHRCTERISTICS DN15 Reece Code & Description 13783 TOMSON NRI LL VLVE 15MM C&C 13784 TOMSON NRI LL VLVE 2MM C&C 13785 TOMSON NRI LL VLVE 15MM C&C (INT FLRE) 13788 TOMSON NRI LL VLVE 15MM F&F 13789 TOMSON NRI LL VLVE 2MM F&F Conditions Maximum Inlet Pressure: 14kPa Maximum Inlet Temperature (Peak): 93ºC Maximum Inlet Temperature (Continuous): 65ºC Fluid Media: Water 2 Year : S1357.1 and S1357.2 Lic. No. WMK21984 Pressure Drop (kpa) 1 9 8 7 6 5 4 3 2 1 5 1 15 2 25 3 35 4 45 Flow rate - Litres per minute 15mm Must be fitted and installed in accordance with S/ NZS 35.1 and by a licensed plumber. Install valve with direction of flow as indicated by arrow on valve body. Valve suitable for horizontal or vertical installations. Flush plumbing lines before connection. Ensure that the leaver is easily accessible. FLOW CHRCTERISTICS DN2 Valve ody: DR rass Handle: luminium Pressure Drop (kpa) 3 25 2 15 1 5 2mm 1 2 3 4 5 6 7 Flow rate - Litres per minute C C 15 MM (OLIVE) 2 MM (OLIVE) Tomson C&C 15 MM (INT FLRE) 13mm 11mm 94mm 75mm 75mm 74mm C 45mm 53mm 45mm Tomson F&F 15 MM 2 MM 81mm 95mm 75mm 75mm C 45mm 53mm Tomson Valves 5

Pressure Reducing Valves D C E Straight djustable 15 MM 2 MM 25 MM D 1/2 3/4 1 74.5mm 74.5mm 74.5mm C 22mm 22mm 23mm D Ø46mm Ø46mm Ø46mm E 79mm 84.5mm 95mm Right ngled Locked 2 MM C 3/4 67mm C 46mm D Ø46mm E 43mm E 6 Tomson Valves

STRIGHT DJUSTLE Recommended use Reduce pressure from domestic mains water supply. RIGHT NGLED LOCKED Recommended use Reduce pressure from domestic mains water supply. Reece Code and Description 9549 TOMSON PRV STRIGHT 1-6KP 15MM 95491 TOMSON PRV STRIGHT DJ 1-6KP 2MM 95492 TOMSON PRV STRIGHT DJ 1-6KP 25MM Conditions Maximum Supply Temperature: 8ºC Maximum Inlet Pressure: 2kPa djustable Outlet Pressure Range: 1 6kPa (Factory Set at 5kPa) Fluid Media: Water Operating Specifications Factory Set Pressure: 5kPa ± 1% 2 Years S1357.2 Lic. No. WMK2467 Do not install valve where it may become frozen. Freezing will cause damage to the valve components Pressure djustment: The valve is user adjustable. Use flat-bladed screw driver to increase or decrease outlet pressure as required. Reece Code and Description 95493 TOMSON PRV R/NG LOCKED 5KP 2MM Conditions Maximum Supply Temperature: 8 C Maximum Inlet Pressure: 2kPa djustable Outlet Pressure Range: Locked @ 5kPa Fluid Media: Water Operating Specifications Factory Set Pressure: 5kPa ± 1% 2 Years S1357.2 Lic. No. WMK2467 Do not install valve where it may become frozen. Freezing will cause damage to the valve components Surface Finish: Valve ody is natural finish forged brass. Ports: The entry port is at a right-angle (9º) with the exit port. Cap: S Surface Finish: Valve ody is natural finish forged brass. Gauge Port: Valve body has a G ¼ gauge port with removable gauge plug. Cap: S Flow Characteristics 15 1 /2 3 /4 1 Flow Characteristics 15 3 /4 Pressure Loss (kpa) 12 1 8 7 6 5 4 3 Pressure Loss (kpa) 12 1 8 7 6 5 4 3 5 1 2 5 Flow rate - Litres per minute 5 1 2 5 Flow rate - Litres per minute Tomson Valves 7

Pressure Limiting Valves INLET PRESSURE CONTROL The Tomson inline pressure limiting valve (PLV) limits supply pressure to a preset maximum to prevent damage to appliances and tapware down the line. The valve remains open whilst the pressure in the supply line remains below that preset maximum pressure. n increase in the supply pressure above the preset limit will cause the valve to shut-off until pressure returns below the limit. Reece Code Product Description Part Number 954 TOMSON PLV F&F 15MM 35KP P1132.GG 9541 TOMSON PLV F&F 15MM 5KP P1132.NN 9542 TOMSON PLV F&F 15MM 6KP P1132.RR 9543 TOMSON PLV C&C 15MM 35KP P1T122G.GG 9544 TOMSON PLV C&C 15MM 5KP P1T122G.NN Specifications Maximum inlet temperature: 8 C Maximum inlet pressure: 2. kpa L 2 years Ø S1357.2 Lic No. WMK25646 C&C Flush all impurities from pipe before installing the Tomson PLV Install the valve in accordance with direction of flow, as indicated by an arrow on the valve body The valve is suitable for vertical or horizontal installation Install the Tomson PLV downstream of a Tomson NRI valve and line strainer Must be installed by a licensed plumber to S/NZS 35. L Ø 78mm 35.8mm L ody Spring Seat disc Piston UNI EN 12164 CW62 ISI 32 EN 127-3NS UNI EN 12164 CW62 + EPDM ISI 34 EN 127-3NS F&F Ø L Ø 89mm 35.8mm 8 Tomson Valves

ackflow Prevention Valves COMPCT DOULE CHECK VLVE Recommended Use To prevent contamination of water supply in a medium hazard application. Reece Code & Description 952346 TOMSON CKFLOW COMPCT DCV 2MM 952347 TOMSON CKFLOW COMPCT DCV 25MM Conditions Maximum Supply Temperature: 9 C Maximum Inlet Pressure: 12kPa 2 Year : S/NZS 2845.1:1998 Lic. No. WMK1325 Operating Specifications Operating Temperature Range 1 C 9 C Minimum Pressure Differentral 7kPa (between valve inlet and outlet) 12 FLOW CHRT FOR 96 DOULE CHECK VLVE Must be fitted and installed in accordance with S/NZS 35.1.2 Pressure Loss (kpa) 1 8 6 4 2 2 4 6 8 1 12 14 16 18 Flow rate - Litres per minute 2 22 24 2mm 25mm Surface Finish: Unplated ody and End Connections: Forged DR rass Check Valves: Neoperl Thermoplastic (High Temperature) (S 42 pproved) Testcocks: (S 42/S2345 pproved) Internal Spacers: Wrought DR rass Seals: Tesnit (S 42 pproved) Retainer: 34 Stainless Steel Tomson DCV 2 MM 25 MM 17mm 165mm 16mm* 16mm* * 16mm Minimum clearance required for removal and replacement of test cocks Tomson Valves 9

Pressure & Temperature Relief Valves Recommended Use The Pressure and Temperature Relief Valve is designed to relieve excess pressure and temperature, which may develop during the normal heating cycle. Reece Code & Description 95395 TOMSON PTR VLVE 15MM 85KP 95396 TOMSON PTR VLVE 15MM 1KP 95397 TOMSON PTR VLVE 15MM 14KP 95398 TOMSON PTR VLVE W/EXT 15MM 1KP 95399 TOMSON PTR VLVE W/EXT 15MM 14KP Conditions Inlet ½ male Drain ½ female Standard pressure settings: 85, 1, 14 kpa Opening temperature not exceeding 99 C Valve rated:1 kw 2 Year Designed and Manufactured to S1357.1 WMK 938 71mm From tip of Lever to end of Drain connection outlet 99mm Should the temperature probe protruding from inside the inlet thread be damaged or bent, do not install, and obtain a replacement valve. Clean out all deposits from the valve housing before fitting a replacement valve, otherwise the new valve risks contamination and premature failure. pply PTFE thread tape to the male taper thread, making sure that the tape does not hang over the outer end of the thread, as this can lead to premature valve failure. Screw the valve into the heater socket. Do not use a wrench on the valve body. No valves, taps, or other isolating devices are to be fi tted between the Temperature and Pressure relief valve and the water heater. Install the drain line to match the nominal size of the valve 17mm Valve ody:dr brass Exposed Probe Length 72mm PTR with extended body 17mm 121mm 49mm 1 Tomson Valves

Expansion Control Valves Recommended Use Expansion Control Valves are fitted to allow cold water to be relieved during the heating expansion cycle Reece Code & Description 95391 TOMSON ECV 15MM 7KP 953911 TOMSON ECV 15MM 85KP 953912 TOMSON ECV 15MM 12KP Conditions Inlet ½ SPT male Drain ½ SP female Standard pressure settings: 7, 85, 12 kpa Opening temperature not exceeding 99 C Valve rated: 2 kw 2 Year Designed and Manufactured to S1357.1 WMK 938 Clean out all deposits from the valve housing before fitting a replacement valve, otherwise the new valve risks contamination and premature failure. pply PTFE thread tape to the male taper thread, making sure that the tape does not hang over the outer end of the thread, as this can lead to premature valve failure. Screw the valve into a T piece fitted between the non-return valve and the heater inlet. Do not use a wrench on the valve body. Install the drain line to match the nominal size of the valve. 71mm From tip of Lever to end of Drain connection outlet Valve ody:dr brass 99mm Tomson Valves 11

Notes: 12 Tomson Valves

Tomson Valves 13

Reece. Works for you. Call 18 32 566 or visit www.reece.com.au for your nearest Reece store. The information provided in this brochure is provided as a guide only. Reece Pty Ltd does not warrant or accept liability in relation to the accuracy of this information. Individual users should make their own assessment of the information provided. Reece Pty Ltd reserves the right to change specifications, designs and availability without prior notice. Due to limitations in the printing process the colours in this brochure are a guide only. Reece Pty Ltd accepts no responsibility for possible errors or omissions. The use of the information in this brochure is subject to the terms and conditions which are located on the Reece website being www.reece.com.au V7 (ROCHURE CODE 213184)