Operating and installation instructions

Similar documents
Operating and installation instructions

Operating and installation instructions

Operating and installation instructions Safety relief valves ARI-REYCO R / RL Series (Full Nozzle)

Operating and installation instructions Safety valves SAFE

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

Declaration of Conformity as per Directive 97/23/EC

Steam Trap BK 15 (DN40, DN 50) Original Installation Instructions English

Installation & Operation Manual Proven Quality since 1892

Mounting and Operating Instructions EB 2172 EN. Series 43 Temperature Regulators. Type 43-5 and Type Type Type 43-6

Mounting and operating instructions EB 2530 EN. Self-operated Pressure Regulator. Pressure Reducing Valve Type M 44-2

Mounting and Operating Instructions EB EN. Self-operated Pressure Regulators. Type 2335 Excess Pressure Valve with pilot valve

Declaration of Conformity as per Directive 97/23/EC

Mounting and Operating Instructions EB 3017 EN. Self-operated Regulators

Steam Trap BK BK 212-ASME. Original Installation Instructions English

Mounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator

Declaration of Conformity as per Directive 97/23/EC

Installation and operating manual. Pneumatic control station LK product no: PCS 1-10

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Type Type Differential Pressure Regulators (opening)

Steam trap BK 37 BK 28 BK 29 BK 37 ASME BK 28 ASME BK 29 ASME

DC5A. Cyclone Separator Trap for Air. Copyright 2015 by TLV Co., Ltd. All rights reserved ISO 9001/ ISO MA-03 (DC5A) 19 June 2015

TD45 Thermodynamic Steam Trap Installation and Maintenance Instructions

CAST IRON SAFETY VALVE TYPE 6301

USER MANUAL Version: 1/2017

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity

USER MANUAL. 1. Principle of operation. 2. Delivery condition. SPRING-LOADED SAFETY VALVES zarmak. Edition: 07/2016 Date: V (ex.

Type BBS-03, BBS-05, BBS-06, BBS-25

Mounting and Operating Instructions EB 3009 EN. Self-operated Regulators. Type RS Check Valve (backflow protection)

Spiratec ST14, ST16 and ST17 Sensor Chambers and sensors

Pressure Reducing Valve for Steam Type 2333 A

1. Preface Important Safety Notes Brief Product Information Product Working Principle Installation Guidelines...

PV4 and PV6 Piston Valves

Installation, operation & maintenance manual - original version

KBV21i and KBV40i Key Operated Boiler Blowdown Valves Installation and Maintenance Instructions

Crosby style JCE Safety Valve Installation, Maintenance and Adjustment Instructions CROSBY

Needle valve. Contents. User s Manual. (1) Be sure to read the following warranty clauses of our product 1. (2) General operating instructions 2

Flowmeter. Original operating manual DFM

Spilt body Flange ball valve. TC-205MFF-PN1640 User Manual English Version. Document No: TC-205MFF-PN1640.Ur-manual. Date: 2007/04/2617. Version: 1.

A3S Bellows Sealed Stop Valve Installation and Maintenance Instructions

Engineering Data Sheet

M45 ISO Ball Valve DN25 to 150 Installation and Maintenance Instructions

CA10S, CA14 and CA14S Air and Gas Traps

UNA 45 UNA 46 UNA 46A

Mounting and Operating Instructions EB 8546 EN. Type 4708 Supply Pressure Regulators. Translation of original instructions. Type Type

HM and HM34 Inverted Bucket Steam Traps Installation and Maintenance Instructions

USM21 Sealed Bimetallic Steam Trap for use with Pipeline Connectors Installation and Maintenance Instructions

Manual Actuated Boiler Blowdown Valves

Declaration of Conformity as per Directive 97/23/EC and Manufacturer s Declaration as per Directive 98/37/EC

Neotecha SAPRO - Aseptic sampling valve SV Installation, operation and maintenance instructions

Pressure reducing station. ARI-Pressure reducing station, self-acting or with electro-pneumatic control. ARI-PREsys -S. Pressure reducing station

APCO ARV CLEAN WATER AIR RELEASE VALVES. Model 50A

Dri-Line Mk2 Spirax-Monnier Compressed Air Drain Trap

Operating manual Steam trap

TDC46M, TDS46M and UTDS46M Thermodynamic Steam Traps with Maintainable Seat Installation and Maintenance Instructions

Mounting and Operating Instructions EB 2555 EN. Self-operated Pressure Regulators. Pressure Reducing Valves Type 50 ES Type 50 EM.

Translation of the original Operating Instructions for HKS rubber compensators

CA44, CA44S, CA46 and CA46S Air and Gas Traps

GESTRA Steam Systems AK 45. Installation Instructions Condensate Drain Valve AK 45

USER MANUAL. 781T (ex. 781) 776 ( ex. 775-I)

S1, S2, S3, S5, S6, S7, S8, S12 and S13 Separators Installation and Maintenance Instructions

KTM OM-2 SPLIT BODY FLOATING BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

SCA Series Inverted Bucket Steam Traps

Pressure Reducing Valve DMV 750 set range: bar

Pressure reducing station. ARI-Pressure reducing station, self-acting or with electro-pneumatic control. ARI-PREsys -S. Pressure reducing station

TP1 and TP2 Temporary Cone Shaped Strainers

UIB30 and UIB30H Sealed Inverted Bucket Steam Traps for use with Pipeline Connectors

Operating Instructions. Ball valve fitting according to ZB For pressure transmitter VEGABAR 82. Document ID: 50027

Pfeiffer. Operating, assembly and maintenance instructions for discontinuous sampling valve Series 27i. 1. Design, operation and dimensions

Steam Trap MK 25/2 MK 25/2S

S1, S2, S3, S5, S6, S7, S8, S12 and S13 Separators

Pressure Reducing Valve

Installation, Operating and Maintenance Manual Overflow Regulator Type 94/ 94 E

Model GP PRESSURE REDUCING VALVE Installation & Operation Manual

Installation, Operating and Maintenance Instructions. V914 Cast Iron Flanged Swing Check Valve V914

GESTRA Steam Systems BK 45 BK 45U BK 46. English. Installation Instructions Steam Traps BK 45, BK 45U, BK 46

Pressure Relief Valve DHV 718

Pressure Reducing Valve DMV 755 set range: 1,0-9,0 bar

FTC62 and FTS62 Ball Float Steam Traps Installation and Maintenance Instructions

Non-Return Valve SRK 22A

Inverted Bucket Steam Trap IB 16A-7

KBV21i and KBV40i Air Actuated Boiler Blowdown Valves

EB EN. Type 44-0 B Steam Pressure Reducing Valve Type 44-1 B Pressure Reducing Valve. Translation of original instructions

Combination Air Valve

Ball Float Steam Trap UNA 43 PN 16/CL 125/JIS 10K UNA 46 PN 40/CL 150/CL 300/JIS 10K/JIS 20K DN 80, 100, 150, 3", 4", 6"

TITAN FLOW CONTROL, INC.

TD62LM and TD62M Thermodynamic Steam Traps with Replaceable Seats

Operating instructions for KLINGER SCHÖNEBERG ball valves type RK-Chemoball, type RK-Proball and type RK-Ecoball

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

KTM 50 (DN ) Installation, maintenance and operating instructions

Wafer Check Valve. Contents. User s Manual. (1) Be sure to read the following description of our product warranty 1

Pressure relief valve DHV 716 set range: 0,5-10,0 bar

Pressure relief valve

Operating Instructions in compliance with Pressure Equipment Directive 2014/68/EU. FAS Manual Brass Shut-Off Valve DN10 through DN22

WHEATLEY Series 500 Swing Check Valve

SAPAG. Safety valves, type 5700 Storage, Use, Operation and Maintenance Instructions. IMPORTANT NOTICE

T R A N S L A T I O N Declaration of Conformity as per Directive 2014/68/EU

IFTGS14 Ball Float Steam Trap ½" and ¾" with Integral Spiratec Sensor

Pneumatic proportional controller Types M Types FM Function tested for use of the float in Ex-zone 0

MST21 Stainless Steel Balanced Pressure Thermostatic Steam Trap

Telefon (+45) Telefax (+45)

Transcription:

Ball float steam traps CONA S (PN16-160 / Class 125-900) PN16 / PN40 Class 125 / Class 150 / Class 300 - with flanges (series 631...1) - with screwed sockets (series 631...2) - with socket weld ends (series 631...3) - with butt weld ends (series 631...4) PN16 / PN40 Class 125 / Class 150 / Class 300 - with flanges (series 639...1) PN63 / PN100 - with flanges (series 631...1) - with socket weld ends (series 631...3) - with butt weld ends (series 631...4) PN160 Class 900 - with flanges (series 631...1) - with socket weld ends (series 631...3) - with butt weld ends (series 631...4) Angle pattern: - with flanges (series 632...1) - with butt weld ends (series 632...4) 1.0 General information on operating instructions...2-2 2.0 Notes on possible dangers...2-2 2.1 Significance of symbols... 2-2 2.2 Explanatory notes on safety information... 2-2 3.0 Storage and transport...2-2 4.0 Description...2-3 4.1 Scope of application... 2-3 4.2 Operating principles... 2-3 4.3 Diagram... 2-4 4.4 Technical data - remarks... 2-6 4.5 Marking... 2-6 5.0 Installation...2-7 5.1 General notes on installation... 2-7 5.2 Installation instructions for welding... 2-8 5.3 Controller adjustment... 2-8 5.4 Steam trap testing through ultrasonic measurement... 2-8 Contents 5.5 Installation position... 2-8 5.5.1 Possible installation positions... 2-9 6.0 Putting the valve into operation... 2-9 7.0 Care and maintenance... 2-10 7.1 Cleaning and/or replacing the steam trap... 2-10 7.2 Changing the installation position...2-11 7.3 Options blow down valve / manual air vent valve... 2-12 7.4 Union for pressure compension line resp. external vent... 2-12 7.5 Tightening torques... 2-13 8.0 Troubleshooting... 2-14 9.0 Troubleshooting table... 2-14 10.0 Dismantling the valve or the body... 2-15 11.0 Warranty / Guarantee... 2-15 Rev. 0040805000 0618 english - Translated original instructions -

1.0 General information on operating instructions These operating instructions provide information on mounting and maintaining the fittings. Please contact the supplier or the manufacturer in case of problems which cannot be solved by reference to the operating instructions. They are binding on the transport, storage, installation, start-up, operation, maintenance and repair. The notes and warnings must be observed and adhered to. - Handling and all work must be carried out by expert personnel or all activities must be supervised and checked. It is the owner s responsibility to define areas of responsibility and competence and to monitor the personnel. - In addition, current regional safety requirements must be applied and observed when taking the fittings out of service as well as when maintaining and repairing them. The manufacturer reserves the right to introduce technical modifications at any time. These Operating Instructions comply with the requirements of EU Directives. 2.0 Notes on possible dangers 2.1 Significance of symbols... Warning of general danger. 2.2 Explanatory notes on safety information In these Operating and Installation Instructions dangers, risks and items of safety information are highlighted to attract special attention. Information marked with the above symbol and ATTENTION! describe practices, a failure to comply with which can result in serious injury or danger of death for users or third parties or in material damage to the system or the environment. It is vital to comply with these practices and to monitor compliance. All other information not specifically emphasised such as transport, installation, operating and maintenance instructions as well as technical data (in the operating instructions, product documentation and on the device itself) must also be complied with to the fullest extent in order to avoid faults which in turn can cause serious injury to persons or damage to property. 3.0 Storage and transport - Protect against external force (like impact, vibration, etc.). - Valves must not be used to take external forces, e.g. they are not designed for use as climbing aids, or as connecting points for lifting gear. - Suitable materials handling and lifting equipment should be used. See catalog sheet for weights. - At -20 C to +65 C. - The paint is a base coat to protect against corrosion during transportation and storage. Do not damage paint protection. Page 2-2 Rev. 0040805000 0618 - Translated original instructions -

4.0 Description 4.1 Scope of application Float-type steam traps with level control and thermal regulation are used for the drainage of industrial steam facilities. - Refer to the data sheet for applications, limits on use and possibilities. - Certain media require or preclude the use of special materials. - The valves are designed for standard operating conditions. If conditions exceed these requirements, e.g. aggressive or abrasive media, the operator should state the higher requirements when ordering. - Valves made from grey cast iron are not authorised for use in systems subject to TRD 110. The information complies to the Pressure Equipment Directive 2014/68/EU. It is the responsibility of the machine planner to ensure compliance. The special markings on the valve must be taken into account. Refer to the catalogue sheet to see which materials are used in standard versions. Please contact the supplier or the manufacturer if you have any questions. 4.2 Operating principles (see Fig. 7a and b page 11) The steam trap is controlled by a swivel-mounted ball float (Pos. 24.16). An integral bimetallic element (Pos. 24.6) provides automatic starting ventilation in the cold state. At temperatures less than 90 C, the bi-metallic element holds the discharge orifice open, allowing air and other gasses to escape. At 90 C the bi-metallic element is fully closed and discharge is controlled only by the float mechanism (Pos. 24.16). At the higher temperatures, air is automatically evacuated (Pos. 24.12), ejector style, with the condensate. If the amount of condensate decreases or if there is no condensate, the ball float (Pos. 24.16) faces and locks the valve ball (Pos. 24.4) on the seat (Pos. 24.1). If the steam trap is acted upon only by vapour, the condensate-flooded seat (Pos. 24.1) remains shut. The valve ball (Pos. 24.4) also works with the seat (Pos. 24.1) as a non-return valve. - Translated original instructions- Rev. 0040805000 0618 Page 2-3

4.3 Diagram Fig. 1: CONA S - series 631 PN16-40 DN15-50 Class 125 / Class 150 / Class 300 NPS 1/2-2 Fig. 2: CONA S - series 631 PN63-100 PN63 without erosion deflector (pos. 29) DN15-50 Page 2-4 Rev. 0040805000 0618 - Translated original instructions -

Fig. 3: CONA S - series 631 PN160 DN15-50 Class 900 NPS 1/2-2 Fig. 4: CONA S - series 632 PN160 DN15-50 Class 900 NPS 1/2-2 - Translated original instructions- Rev. 0040805000 0618 Page 2-5

Fig. 5: CONA S - series 639 PN16-40 DN50-100 Class 125 / Class 150 / Class 300 NPS 2-4 Refer to the data sheet for information about materials with designations and figure numbers. 4.4 Technical data - remarks for - Principal dimensions, - Pressure-temperature-ratings, operating limits, - Valves with different types of connection, etc. refer to datasheet. 4.5 Marking Details of the CE-marking on the valve: CE-marking 0090 Notified body EAC-marking AWH Manufacturer Typ Bj. Type Year of manufacture Address of manufacturer: refer to item 11.0 Warranty / Guarantee Page 2-6 Rev. 0040805000 0618 - Translated original instructions -

5.0 Installation 5.1 General notes on installation The following points should be taken into account besides the general principles governing installation work: - Remove flange covers if present. - The interior of valve and pipeline must be free from foreign particles. - The float steam trap can be installed for vertical or horizontal flow. Note installation position with reference to flow, see mark on valve. - Steam line systems should be designed to prevent water accumulation. - Lay pipelines so that damaging transverse, bending and torsional forces are avoided. - Protect valves from dirt during construction work. - Connection flanges must mate exactly. - Valves must not be used to take external forces, e.g. they are not designed for use as climbing aids, or as connecting points for lifting gear. - Suitable materials handling and lifting equipment should be used. See data sheet for weights. - Centre gaskets between the flanges. - Precautions against freezing should be taken as a matter of course in any facilities susceptible to frost. If a system not in operation is in a position susceptible to freezing, we recommend that the drain plug (Pos. 50) on the unpressurised steam trap be unscrewed, the residual condensate drained off, the seal faces cleaned and the plug screwed down again. The sealing ring (Pos. 49) should be replaced if necessary. (see Fig. 1 page 4 - Fig. 5 page 6) - Planners / construction companies or operators are responsible for positioning and installing products. - The valves are designed for application, not influenced from weather. - For application outside or in adverse environments like corrosion-promoting conditions (sea water, chemical vapours, etc.), special constructions or protective measures are recommended. - Translated original instructions- Rev. 0040805000 0618 Page 2-7

5.2 Installation instructions for welding Operating and installation instructions (refer to Fig. 3 page 5) Please note that only qualified persons using appropriate equipment and working in accordance with technical rules are allowed to install fittings by welding. The responsibility for this lies with the system owner. Please refer to the catalogue sheet for information on type and instructions relating to welding socket weld ends/butt weld ends. When welding products to the pipeline system they should be adequately cooled to prevent any adverse effect on the complete controller assembly (Pos. 24) or possibly the flat gasket (Pos. 17). The heat-affected zone should be restricted to the immediate weld seam area! Note pre- and post-welding heat treatment in accordance with Material Fact Sheet DIN EN 10222. If there are plans to acid clean the facility before putting it into operation, the controllers (Pos. 24) should be dismantled completely, replaced by acid cleaning inserts, and reassembled after acid cleaning (see 7.1). In such an event please contact the manufacturer. 5.3 Controller adjustment The controller is set by the manufacturer as stated in the order and does not need changing. Should the operating parameters have changed fundamentally compared with the particulars in the order, please contact the manufacturer to change the controller! 5.4 Steam trap testing through ultrasonic measurement Testing the operation of the steam trap in the installed state is straightforward with the ARImetec -S mulitfunctional testing device. Refer to data sheet ARImetec -S. 5.5 Installation position (refer to Fig. 6 page 9 and Fig. 7a and b page 11) The float steam trap can be installed for vertical or horizontal flow. This should be stated when ordering. If the installation position is not stated it will be supplied for vertical flow. It is possible to change the installation position at a later stage (see 7.2). However the steam trap must always be installed so that the ball float (Pos. 24.16) can work in a vertical plane. The vent tube (Pos. 24.12) must point up! Page 2-8 Rev. 0040805000 0618 - Translated original instructions -

5.5.1 Possible installation positions Horizontal installation: Inlet from the left side (ZL) Vertical installation (standard): Inlet from the top Horizontal installation: Inlet from the right side (ZR) Fig. 6 6.0 Putting the valve into operation - Before putting the valve into operation, check material, pressure, temperature and direction of flow. - Regional safety instructions must be adhered to. - Residues in piping and valves (dirt, weld beads, etc.) inevitably lead to leakage. - Touching the valve when it is operating at high (> 50 C) or low (< 0 C) media temperatures can cause injury. Affix warning notice or protective insulation as appropriate! Before putting a new plant into operation or restarting a plant after repairs or modification, always make sure that: - All works has been completed! - The valve is in the correct position for its function. - Safety devices have been attached. - Translated original instructions- Rev. 0040805000 0618 Page 2-9

7.0 Care and maintenance Operating and installation instructions Maintenance and maintenance-intervals have to be defined by the operator according to the requirements. - refer to item 10.0 and 11.0 prior to dismantling and repair work! - refer to item 6.0 before restarting the plant! Prior to installation, threads and seal faces should be coated with temperaturestable lubricant (e.g. OKS Anti-Seize Paste white/metal-free for PN 16-40 / Class 125 / Class 150 / Class 300or Rivolta lubricant and parting agent for PN 63 / Class 900 onwards). 7.1 Cleaning and/or replacing the steam trap (refer to Fig. 1 page 4- Fig. 5 page 6 and Fig. 7a and b page 11) - Dismantle hood (Pos. 16) by slackening hexagonal nuts (Pos. 28) and cheese-head screw (Pos. 27). - While removing the hood (Pos. 16) swivel it upwards through approx. 45o to avoid twisting the vent tube (Pos. 24.12). Dismantle studs (Pos. 27) PN63-160 / Class 900 if necessary. - Remove dirt from body (Pos. 1) and hood (Pos. 16); tiny dirt particles can be removed by flushing out the ducts and rinsing the body (Pos. 1). Clean the strainer (Pos. 2). - If necessary dismantle the float controller (Pos. 24) and clean separately or change float controller. - Unscrew the hollow-core screw (Pos. 24.10) of the float controller (Pos. 24) from the body (Pos. 1). - Pull complete float controller (Pos. 24) out to remove, taking care with the sealing ring (Pos. 11). (From PN63 onwards metal seal with no sealing ring (Pos. 11)). - Do not make any changes to spindle adjustment (Pos. 24.3), the float controller (Pos. 24) is set by the manufacturer (except in the case of extremely high back pressures, when please consult the manufacturer). - Check lifting force of the ball float (Pos. 24.16) by immersing the whole controller (Pos. 24) in a water bath with the vent tube (Pos. 24.12) pointing upwards spindle (Pos. 24.3) in a horizontal position. When immersed in the water bath the ball float (Pos. 24.16) must float to the top. If the ball float (Pos. 24.16) sinks (i.e. goes under) the complete controller (Pos 24) should be replaced! - The flat gasket (Pos. 17) and sealing ring (Pos. 11) should be replaced if used. PN100-160 / Class 900: - Special wear bushing is used. This can, if necessary, be changed after dismantling the controller (Pos. 24). It is used to protect the body (Pos. 1) from blasting wear. - Assemble in reverse order (refer to item 7.5). Page 2-10 Rev. 0040805000 0618 - Translated original instructions -

7.2 Changing the installation position Operating and installation instructions (refer to Fig. 1 page 4- Fig. 5 page 6 und Fig. 7a and b page 11) - Position body (Pos. 1) as desired, bearing in mind the direction of flow. - Remove hood (Pos 16), then slacken hollow-core screw (Pos. 24.10) approximately 1/2 turn. - Rotate controller (Pos. 24) 90º in the direction required The vent tube (Pos. 24.12) must point upwards! - Tighten hollow-core screw (Pos. 24.10) by holding against nozzle part (Pos. 24.11). - Inspect and if necessary replace body seal (Pos. 17). - Put on hood (Pos. 16) with the drain plug (Pos. 50) pointing diagonally down. - Fit hexagonal nuts (Pos. 28) (see 7.5) and tighten crosswise. PN63: - A resilient sleeve (Pos. 30) is also fitted to the union of body (Pos. 1) and hood (Pos 16). Fig. 7a: CONA S - series 631 PN63 Bild 7b: Controller, cpl - Translated original instructions- Rev. 0040805000 0618 Page 2-11

7.3 Options blow down valve / manual air vent valve (siehe Fig. 1 page 4 and Fig. 8 page 12) Escape of hot medium under pressure! Observe item 2.2! Operating and installation instructions Accumulated dirt and condensate can be removed from the hood (Pos. 16) through the blow down valve by opening the pressure screw (Pos. 46.1). When opening, hold against blow down valve (Pos. 46). Accumulating inert gases can also be discharged to the environment using the manual air vent valve (Pos. 51) by opening the pressure screw (Pos 51.1). During operation it is imperative to observe general working safety conditions and possibly fit devices to guard against scalding/injury. Note section 7.5 when installing and operating the option. Fig. 8 7.4 Union for pressure compension line resp. external vent By connecting a pressure compensation line to the union (Pos. 52) it is possible to return the accumulating inert gases to the system and to bypass the controller using a Series 614 diverter as an external vent. Note section 7.5 when installing the option. Fig. 9 Page 2-12 Rev. 0040805000 0618 - Translated original instructions -

7.5 Tightening torques (siehe Fig. 1 page 4 - Fig. 9 page 12) Pos. CONA S PN16 / Class 125 DN15-20 / NPS 1/2-3/4 Torque (Nm) DN25 / NPS 1 DN32-50 / NPS 1 1/2-2 24 Controller 60 60 100 50 Plug 50 50 50 27 Cheese head screw M10 / M12 / M16 15 25 50 51 Manual air vent valve 50 50 50 51.1 Pressure screw 30 30 30 46 Blow down valve 50 50 50 46.1 Pressure screw 30 30 30 52 Union for pressure compension line 50 50 50 Pos. CONA S PN40-160 / Class 300 / Class 900 DN15-20 / NPS 1/2-3/4 Torque (Nm) DN25 / NPS 1 DN32-50 / NPS 1 1/2-2 24.8 Hex. nut M4 5 5 10 50 Plug 70 70 70 51 Manual air vent valve 70 70 70 51.1 Pressure screw 30 30 30 46 Blow down valve 70 70 70 46.1 Pressure screw 30 30 30 Pos. CONA S PN40 / Class 150 / Class 300 DN15-20 / NPS 1/2-3/4 Torque (Nm) DN25 / NPS 1 DN32-100 / NPS 1 1/2-4 24 Controller 60 60 100 27 Cheese head screw M12 / M12 / M16 25 30 60 52 Union for pressure compension line 70 70 70 Pos. CONA S PN63-100 Torque (Nm) DN15-20 DN25 DN32-50 24 Controller 130 130 130 28 Hex. nut M20 150 150 150 Pos. CONA S PN160 / Class 900 DN15-20 / NPS 1/2-3/4 Torque (Nm) DN25 / NPS 1 DN32-50 / NPS 1 1/2-2 24 Controller 130 130 130 28 Hex. nut M20 180 180 180 Page 2-13 Rev. 0040805000 0618 - Translated original instructions -

8.0 Troubleshooting In the event of malfunction or faulty operating performance check that the installation and adjustment work has been carried out and completed in accordance with these Operating Instructions. - It is essential that the safety regulations are observed when identifying faults. If malfunctions cannot be eliminated with the help of the following table 9.0 troubleshooting table, the supplier or manufacturer should be consulted. 9.0 Troubleshooting table - refer to item 10.0 and 11.0 prior to dismantling and repair work! - refer to item 6.0 before restarting the plant! Fault Possible cause Corrective measures No flow Installed in wrong flow direction Fit valve in direction of flow arrow. Note installation position; refer to item 5.5.1! Flange covers not removed Remove flange covers Ball float (Pos. 24.16) defective Check lifting force; refer to item 7.1 Little flow Wrong installation position Note installation position; refer to item 5.5.1 Correct installation position; refer to item 7.2 Strainer clogged (Pos. 2) Clean strainer; refer to item 7.1 Piping system clogged Check piping system Wrong controller size choosen Correct selection acc. to flow diagram Changed upstream pressure or back pressure operating conditions Correct selection acc. to flow diagram No closure or internal leakage External leakage Excessive amount of inert gases in system Use pressure compensation line and external vent option; refer to item 7.4 Controller clogged Clean strainer and controller; refer to item 7.1 Controller worn out Change controller; refer to item 7.1 Controller incorrectly screwed into body Check seal face between body and controller, tighten controller correctly; refer to item 7.5 Controller operated above safe operating pressure Hood (Pos. 16) not properly tightened with hex. nut (Pos. 28) or cheese-head screw (Pos. 27) Flat gasket (Pos. 17) defective Observe operating limits as per data sheet, i.e. possibly select different controller Tighten; refer to item 7.5 Replace sealing; refer to item 7.1 Page 2-14 Rev. 0040805000 0618 - Translated original instructions -

10.0 Dismantling the valve or the body The following points must be observed: - Pressureless pipe system. - Medium must be cool. - Plant must be drained. 11.0 Warranty / Guarantee Operating and installation instructions The extent and period of warranty cover are specified in the "Standard Terms and Conditions of Albert Richter GmbH & Co. KG valid at the time of delivery or, by way of departure, in the contract of sale itself. We guarantee freedom of faults in compliance with state-of-the-art technology and the confirmed application. No warranty claims can be made for any damage caused as the result of incorrect handling or disregard of operating and installation instructions, datasheets and relavant regulations. This warranty also does not cover any damage which occurs during operation under conditions deviating from those laid down by specifications or other agreements. Justified complaints will be eliminated by repair carried out by us or by a specialist appointed by us. No claims will be accepted beyond the scope of this warranty. The right to replacement delivery is excluded. The warranty shall not cover maintenance work, installation of external parts, design modifications or natural wear. Any damage incurred during transport should not be reported to us but rather to the competent cargo-handling depot, the railway company or carrier company immediately or else claims for replacements from these companies will be invalidated. Technology for the Future. GERMAN QUALITY VALVES ARI-Armaturen Albert Richter GmbH & Co. KG, D-33750 Schloß Holte-Stukenbrock Telephone (+49 5207) 994-0 Telefax (+49 5207) 994-158 or 159 Internet: http://www.ari-armaturen.com E-mail: info.vertrieb@ari-armaturen.com - Translated original instructions- Rev. 0040805000 0618 Page 2-15