A MICRO-SCALE N 2 REJECTION PLANT TO UPGRADE LOW-BTU MARGINAL GAS

Similar documents
DEMONSTRATION OF A LOW COST 2-TOWER MICRO SCALE N 2 REJECTION SYSTEM TO UPGRADE LOW-BTU GAS FROM STRIPPER WELLS

A NEW PROCESS FOR IMPROVED LIQUEFACTION EFFICIENCY

Removing nitrogen. Nitrogen rejection applications can be divided into two categories

1 PIPESYS Application

PTRT 2470: Petroleum Data Management 3 - Facilities Test 4 (Spring 2017)

Fundamentals of Vapor Recovery

CALCULATING THE SPEED OF SOUND IN NATURAL GAS USING AGA REPORT NO Walnut Lake Rd th Street Houston TX Garner, IA 50438

Agilent 490 Micro GC Natural Gas Analyzer

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs.

Your local gas generation partner. Precision series Modular gas generation solution for GC.

Gas Turbine Performance Analysis

MASS FLOW SYSTEMS MASS FLOW MEASURING, CONTROLLING AND BLENDING SYSTEMS

Chapter 22 Testing Protocols

SUPERSONIC GAS TECHNOLOGIES

Your local gas generation partner. Precision series Modular gas generation solution for GC.

By: Eng. Ahmed Deyab Fares - Mobile:

The Feasibility of Flare Gas Recovery for Ethylene Plants Dr. John Joyce, PhD, PE

Designing Flexible Plants for Market Adaptation

NITROGEN GENERATION FOR INDUSTRIAL APPLICATIONS

Your local gas generation partner. Precision series Modular gas generation solution for GC.

Chapter 8: Cryo-sorption pumps

Successful Implementation of Dry Gas Seal in High Pressure Recycle gas Compressor at Hydrocracker & Effect of Gas composition on DGS Performance

Efficient Pigging of Gathering Lines. Energy Management Workshop for Upstream and Midstream Operations

Traceability of greenhouse gases and volatile organic compounds for air monitoring in South Africa

Applied Technology and Best Practices in CEE. Conference

ISO INTERNATIONAL STANDARD

Multiple Gas#5 GC configuration Jan 2016

GAS CONDENSATE RESERVOIRS. Dr. Helmy Sayyouh Petroleum Engineering Cairo University

Medical Oxygen Concentrator Systems. Generate gases on site generate savings

IRwin Methane Leak Detector. Innovation makes the difference

hydro-pac, inc. Low-Pressure Gas Compressors 1500 to 6000 PSI

AIR DRIVEN. Gas Boosters & SYSTEMS. Accepting VISA, MasterCard and American Express

Nitrogen subtraction on reported CO 2 emission using ultrasonic flare gas meter

Misuse of Combustible Gas Meters

Column Design Using Mass Transfer Rate Simulation

VERIFYING GAS CHROMATOGRAPH OPERATION AT CUSTODY TRANSFER LOCATIONS Murray Fraser Daniel Measurement & Control

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

R-410A 50% R-32 50% R-125.

Three Columns Gas Chromatograph Analysis Using Correlation between Component's Molecular Weight and Its Response Factor

Laser Gases and Support

TECHNICAL INFORMATION

Simplicity in VRU by using a Beam Gas Compressor

FlashCO2, CO2 at 23 $/ton

USE A RELIABLE A INNOVATIVE A COST EFFICIENT GAS EQUIPMENTS AND GAS SYSTEMS

PRECISION GAS MIXTURES

Instrument Performance Evaluation, comparing ISO and NORSOK I-106 Dr Paul Holland, EffecTech Group & Jon Carlsen, Norsk Analyse North Sea Flow

Figure Vapor-liquid equilibrium for a binary mixture. The dashed lines show the equilibrium compositions.

METHOD 3C - DETERMINATION OF CARBON DIOXIDE, METHANE, NITROGEN, AND OXYGEN FROM STATIONARY SOURCES

Linde Cryogenics. Helium Recovery Systems.

INTEROFFICE MEMORANDUM MODIFICATIONS TO DEW POINT CONTROL PROCESS

Improved Reliability in Natural Gas Energy Measurement with the Revised ISO Standard. Gerard Nieuwenkamp - VSL

CAMASS. Calibration Centre. Gas flow technology and services

2. Determine how the mass transfer rate is affected by gas flow rate and liquid flow rate.

Vacuum Simulations of the KATRIN Experiment

PETROLEUM & GAS PROCESSING TECHNOLOGY (PTT 365) SEPARATION OF PRODUCED FLUID

NGN Series nitrogen generator

DISTILLATION POINTS TO REMEMBER

In-Water Mass Spectrometry for Characterization of Light Hydrocarbon Seeps and Leaks

Title: Choosing the right nitrogen rejection scheme

INTRODUCTION. The Quantum Technology system has the following advantages:, as it does not need plastic gas-bags which are volume-consuming,

UNITY 2 TM. Air Server Series 2 Operators Manual. Version 1.0. February 2008

A NOVEL APPROACH TO ETHANE REFRIGERANT EXTRACTION FOR GREENFIELD LNG PLANTS

Dynamic Simulation for T-9 Storage Tank (Holding Case)

Real-time Analysis of Industrial Gases with Online Near- Infrared Spectroscopy

OIL AND GAS SEPARATION DESIGN MANUAL

Detector Carrier Gas Comments Detector anode purge or reference gas. Electron Capture Nitrogen Maximum sensitivity Nitrogen Argon/Methane

The Effect of Air Column in Transport Canisters on Measured Gas Contents

Unique solutions for Oxygen and Nitrogen supply

Technical Manual. Sensepoint XCD Gas Detector

Tproperties of refrigerants, arranged for the occasional user. The

CAMASS. Calibration Centre. Gas flow technology and services

Superior Result from Analytical Instruments The constant purity of the nitrogen improves system stability and ensures reproducible results

S.A. Klein and G.F. Nellis Cambridge University Press, 2011

New low temperature technologies of natural gas processing

MEDICAL EQUIPMENT CATALOG

Simulation and Economic Optimization of Vapor Recompression Configuration for Partial CO2 capture

Fit for Purpose Compositional Input for Allocation Using Equations of State Thomas Hurstell, Letton Hall Group

A Financial Analysis for the Recovery of High Purity Propylene from Refinery LPG R.E. (Ed) Palmer Ian M. Glasgow

Facilities Design Shift Horizontal Equipment in Oklahoma Scott King

Specialty Gases & Equipment ISO 9001: 2008 CERTIFIED. A Division of Norco, Inc.

Review of the Hall B Gas System Hardware. George Jacobs

Nonrefillable Cylinders

AND EQUIPMENT FOR ENVIRONMENTAL APPLICATIONS (800) B Polk Street Houston, TX

Gases&Technology. Measurement of Impurities in Helium Using the Dielectric Barrier Discharge Helium Ionization Detector. FEATURE.

2 Sentry MCL Installation, Operation & Maintenance

Innovating Gas-Lift for Life of Well Artificial Lift Solution. The Unconventional Solution!

Balston Nitrogen Generation Systems

Applied Compression s nitrogen generator packages offer users a cost-effective alternative to costly bottled nitrogen.

The Ultimate Way To Degasify Compressor Seal Oils

Flare Gas Composition Analysis and QA/QC Lessons Learned and Lessons Lost SPECTRUM ENVIRONMENTAL SOLUTIONS, LLC 1

METHOD 21 - DETERMINATION OF VOLATILE ORGANIC COMPOUND LEAKS. 1.2 Scope. This method is applicable for the

BULK GASES BULK GASES. Gases Helium Hydrogen Nitrogen Argon CO2 Nitrogen Oxygen

Elimination of Percent Level H 2 S Calibration Gas from Flare Gas Monitoring Systems Measuring Total Sulfur, H 2 S and BTU.

stat0il Tone Orke Reservoir Fluid Study for Statoil, Well by Arne M.Martinsen LAB Den norske stab ol.ieselskap a.

SUPERIOR RESULTS WITH UNIQUE FEATURES

Vibration-Free Joule-Thomson Cryocoolers for Distributed Microcooling

Gas Boosters & Systems

nert Gas: Inert gas systems on ships

APPLICATION NOTE. Fast Analysis of Coal Mine Gas Using the INFICON 3000 Micro GC ABSTRACT

TABLE OF CONTENTS LIST OF FIGURES

Transcription:

A MICRO-SCALE N 2 REJECTION PLANT TO UPGRADE LOW-BTU MARGINAL GAS Saibal Bhattacharya 1, K. David Newell 1, W. Lynn Watney 1, and Michael Sigel 2 1) Kansas Geological Survey, Lawrence, KS; 2) American Energies Corp, Wichita, KS Project Funding: Stripper Well Consortium (The Pennsylvania State University) Steve Moore: Proposed the initial plant design and the idea behind costeffective low-btu upgradation Alan DeGood: Fianancial Support, Encouragement, and Patience

U.S. natural gas reserves around 204 tcf (EIA, 2006) Sub pipeline quality gas - CO 2 and/or N 2 contaminated - 17.5 tcf in Midcontinent region (Hugman and others, 1990) - 9 tcf in Rocky Mountain region (Hugman and others, 1990) - 60 tcf in the U.S. (Lokhandwala and Zammerille, 2006) Kansas - 33% (of 1253 samples) tested low-btu (Newell, 2007) Sub-quality - due to N 2 contamination Problem Statement - 15+% N 2 reduces heat value to less than 950 BTU/cu ft - Mid-continent - N 2 primary cause (Beebe, 1968; Jenden et al., 1988) - 17% of gas (> 32 tcf) nationwide (Lokhandwala and Zammerille, 2006) - Significantly in modest/small fields - Isolated location, low pressure & flow rates, rapid declines How to upgrade marginal low-btu gas within resource reach of small producers?

Low-BTU Gas in Kansas Significant volumes of Low-BTU periphery of Hugoton field Low-BTU gas is widely prevalent in Kansas. 33% of 1253 samples collected and tested were found to be of low-btu. Centralized upgradation plants - Cryogenic (>5 mmcf/d) - Conventional PSA/TSA (0.5-20 mmcf/d)

Low-BTU in Elmdale Field Most of the wells produce pipeline quality gas from deeper Lansing horizon. Lansing production declining between 15 to 20% annually. Low-BTU gas has been tested in shallower intervals (Ireland, Tecumseh, Douglas) at several wells. Currently, limited low-btu gas produced by blending with higher BTU What happens when Lansing gas runs out? Low-BTU Plant NOTE: Complex geology gas pockets and compositional variation within a zone

Plant Layout Footprint - around 400 sq ft. Low-BTU feed to plant 2 line Upgraded gas to the scrubber and compressor 3 line N 2 -rich vent gas to flare tower 2 line Plant tested - 105 psi and held 28 of Hg vacuum Expected to process - 150 mcf/d feed

Process Towers Diameter = 48 Height = 8 Feed line Upgraded gas line

Surge Tank Knockout vessel in feed line Surge tank 25 long and 5 feet diameter Holding time = 1 hour - Desorbed gas attains uniform composition

Gas Compressor & Engine Engine - 6-cylinder 50 HP VGG-330 gas-fired engine - operates on low-btu feed Compressor - Ingersoll-Rand compressor designed for vacuum service

Adsorption Bed Commonly available activated carbon made from coconut husks was used as adsorption bed Activated carbon was purchased in 1100 lb bags and costs around 7 cents/lb Each tower was charged with 2200 lb of carbon

PLANT BLUE PRINT STEP 1 - Tower 1 Adsorption, Tower 2 Desorption STEP 2 - Tower 1 Venting, Tower 2 in Vacuum STEP 3 - Tower 1 Desorption, Tower 2 Adsorption

CRITICAL FACT ABOUT LOW-BTU UPGRADATION BTU CONTENT BTU/cu ft Methane 1010 Ethane 1770 Propane 2516 i-butane 3253 n-butane 3264 i-pentane 4000 n-pentane 4006 n-hexane 4722 n-heptane 5500 Heavy HCs (C 2 H 6 +) significantly contribute to the BTU content of natural gas. Low-BTU upgraded to pipeline quality if process captures and recovers maximum C 2 H 6 + content. Also, success of upgradation depends on how rich low-btu feed is in terms of its C 2 H 6 + content.

CALIBRATION FOR GAS ANALYSIS Correlations are dependent on both the feed BTU and gas composition (ratio of heavy hydrocarbons to total hydrocarbons, C 2 H 6 +/CH 4 +) Portable handheld hydrocarbon detector y = 1.6496x - 60.292 GC CH4+ % R 2 = 0.961 100 90 80 70 60 50 40 30 20 10 0 HYDROCARBON CONTENT y = 1.2169x - 15.569 R 2 = 0.9976 50 60 70 80 90 100 Handheld CH4+ % y = 11.038x - 29.796 R 2 = 0.9992 BTU dry 1200 1100 1000 900 800 700 600 500 BTU Estimation y = 12.447x - 92.702 R 2 = 0.9982 400 50 60 70 80 90 100 GC CH4+% Palmer + Others Linear (Palmer (new meter)) Palmer (new meter) Linear (Palmer + Others) Palmer + Others Linear (Palmer) Palmer Linear (Palmer + Others) FEED 615 BTU/cu ft, avg C2H6+/CH4+ = 3.8% FEED 700 BTU/cu ft, avg C 2 H 6 +/CH 4 + = 7.9%

Feed @ 700 BTU/cu ft, C 2 H 6 +/CH 4 +=7.9% Vent from Top Pipeline Quality Corrected Corrected Tower Vent to Avg Feed Avg Sales Efficiency Efficiency N2 % in Charge Pr psi CH4+, fr CH4+, fr Sales/Feed N2 stripping CH4+ Rec Vent Gas BTU feed BTU sales BTU rec % 34 2 0.63 0.84 0.54 76.7 73.2 63.1 687 953 75.7 20 2 0.65 0.85 0.60 73.8 77.4 63.2 722 964 79.7 Sales/Feed ratio - indicative of gas (CH 4 + & N 2 ) lost from the system - HIGH - tower charge pressure low, dead space volume minimized - LOW - tower charge pressure high, dead space volume significant N 2 Stripping Efficiency - % of feed N 2 volume that is rejected (vented) - HIGH - high tower charge pressure (more HCs adsorbed) - LOW - low tower charge pressure (less HCs adsorbed) CH 4 + Recovery Efficiency - % of feed HC captured for sales - HIGH - low tower charge pressure (less HCs lost during vent) - LOW - high tower charge pressure (more HCs lost during vent) BTU Recovery Efficiency - (Sales BTU*Sales mcf)/(feed BTU*Feed mcf) - Follows CH 4 recovery efficiency - HCs determine BTU content

GAS ANALYSIS Sample date Sample No. KGS 1 Sample description 30-May-08 Feed gas Component Mole % BTU/scf Hydrogen 0.0000 0.00 Helium 0.6495 0.00 CO2 0.2135 0.00 Neopentane 0.0014 0.00 Nitrogen 33.7049 0.00 Argon 0.1748 0.00 Methane 60.3800 609.84 Ethane 2.8948 51.23 Propane 1.3320 33.52 i-butane 0.1826 5.94 n-butane 0.3161 10.31 i-pentane 0.0664 2.66 n-pentane 0.0665 2.67 n-hexane 0.0135 0.64 n-heptane 0.0040 0.22 CH4+ 65.3 C2H6+ 4.9 C2H6+/CH4+ 0.075 Sample date Sample No. KGS 5 Sample description 6-Jun-08 Sales gas Component Mole % BTU/scf Hydrogen 0.0000 0.00 Helium 0.1225 0.00 CO2 0.1820 0.00 Neopentane 0.0000 0.00 Nitrogen 14.5400 0.00 Argon 0.3692 0.00 Methane 75.3267 760.80 Ethane 5.2381 92.70 Propane 2.7426 69.01 i-butane 0.3890 12.65 n-butane 0.7116 23.22 i-pentane 0.1574 6.30 n-pentane 0.1640 6.58 n-hexane 0.0363 1.73 n-heptane 0.0205 1.13 CH4+ 84.8 C2H6+ 9.5 C2H6+/CH4+ 0.112 Most heavy HCs are adsorbed by the activated carbon and subsequently recovered. Calls in question the feasibility of capturing vent gas for secondary upgradation given that it lacks heavy HCs that significantly add to the BTU of the upgraded gas.

HOW POOR A GAS CAN BE UPGRADED? Feed 615 BTU/cu ft, HHC = 3.8% Corrected Corrected Tower Vent to Avg Feed Avg Sales Efficiency Efficiency N2 % in Charge Pr psi CH4+ % CH4+ % Sales/Feed N2 stripping CH4+ Rec Vent Gas BTU feed BTU sales BTU rec % 15 2 T* 59 78 0.64 66 85 75 619 831 86 30 2 T* 59 82 0.49 79 69 64 622 881 70 70 13 T* 59 86 0.45 85 66 63 621 920 67 66 9.5 T* 59 84 0.49 84 73 68 618 923 74 66 4 T&B** 58 88 0.42 88 64 64 607 940 65 69 3 T&B** 60 89 0.39 90 58 59 633 958 59 72 4 T&B** 60 89 0.40 89 59 59 634 956 60 T* - vent from top; T&B** - vent from top and bottom of the tower Pipeline Quality As feed quality changed, lower BTU and lower C 2 H 6 +/CH 4 + ratio, the plant settings had to be changed dramatically to achieve pipeline quality output that resulted in lower sales/feed ratios. SIMULTANEOUS VENTING FROM TOP & BOTTOM Dead space remains at the bottom of each tower and this is filled with N 2 - rich feed gas after the vent phase. Upon desorption, this remaining feed gas enters the surge tank and lowers the BTU of the sales gas. Attempts were made to flush out much of this feed gas in the bottom dead space by simultaneously venting from both the top and bottom of the tower.

DEAD SPACE IN TOWER FLARE CH 4 Detector - HOTWIRE & TELEMETRY X X Control Panel Scrubber X X Dead space caused by blow out of bed 18 Minimize dead space in tower especially relative to the tower volume. LOW-BTU FEED Dead space topped with activated carbon and sealed by placing a filter in the top flange Inlet Separator & Meter DEAD SPACE X DEAD SPACE X 20 Higher bed mass, increases volume of adsorbed gas and therefore results in higher sales/feed ratios.

PERFORMANCE COMPARISON WITH COMMERCIAL PLANT Daily Feed, mcf 1,300 to 1,750 Seller s % 72 1,100 to 1,299 70 900 to 1,099 68 650 to 899 64 550 to 649 59 450 to 549 55 < 450 51 ADDITIONAL DETAILS Feed limitations: Often cant have too high N 2 (< 28% N 2 ) concentration Transportation costs if pipeline is available to connect source to plant (would additionally cost 13% of volume transported in this case)

PLANT ECONOMICS Feed 150 mcf/d, Gas Price = $7/mcf Plant Construction Costs = $120,000 @ 615 BTU/cu ft feed, Sales = 60 mcf/d, Revenue = $420/daily, Pay out = 9.5 months @ 700 BTU/cu ft feed, Sales = 90 mcf/d, Revenue = $630/daily, Pay out = 6.5 months

FUTURE PLANS 1. Fill-up towers to reduce dead space (at the bottom). 2. Test Towers - Feed at 615 BTU/cu ft. Optimize charge and vent pressures to maximize sales/feed at pipeline quality. 3. Complete building 2nd set of towers where dead space is insignificant to tower volume and operationalize tower at an American Energies (Corp) field. 4. American Energies (Corp) plans to build, install, and sell many more plants. Height = 20, Diameter = 6

CONCLUSIONS YES, WE CAN its is possible to upgrade low-btu gas to pipeline quality using a simple cost-effective plant. Approximating plant construction costs at $120,000 and assuming a feed of 150 mcf/d, payout is estimated at 9.5 months for 615 BTU/cu ft feed and 6.5 months for 700 BTU/cu ft feed. Minimize dead space relative to tower volume. Greater the bed mass, more HCs adsorbed and better the sales/feed ratio. Need to evacuate (desorb) towers to maximum vacuum ( 25 Hg) quickly to recover heavy HCs adsorbed and increase plant throughput. This improves bed life and BTU of desorbed gas. SO DO NOT GO CHEAP ON THE COMPRESSOR. Optimum plant settings will change as per feed composition (BTU and C 2 H 6 +/CH 4 + ratios).