DT400/436 Tee Connector Installation Instructions

Similar documents
COOPER POWER SERIES. 200 A 15, 25, and 35 KV class insulated standoff bushing installation instructions. Loadbreak Apparatus Connectors MN650039EN

COOPER POWER SERIES. 600 Ampere Deadbreak Grounded Standoff Bushing 15 & 25 kv and 35 kv Class Installation Instructions. Bushings MN650045EN

COOPER POWER SERIES. 600 A 15, 25 and 35 kv class bushing adapter installation instructions. Deadbreak Apparatus Connectors MN650058EN

200 A, 15 and 25 kv class loadbreak bushing insert installation instructions

COOPER POWER SERIES. 200 A 15, 25, and 35 kv class portable feedthru installation instructions. Loadbreak Apparatus Connectors MN650037EN

COOPER POWER SERIES. 600 A 15, 25, and 35 kv class PUSH-OP bushing adapter cap installation instructions. Deadbreak Apparatus Connectors MN650050EN

COOPER POWER SERIES. DS250 deadbreak straight connector installation instructions interface A. Connectors MN650027EN

COOPER POWER SERIES. DE250 deadbreak elbow connector installation instructions interface A. Screened Separable Connectors MN650025EN

COOPER POWER SERIES. 200 A 15/25 kv class deadbreak straight connector installation instructions. Deadbreak Apparatus Connectors MN650043EN

DAI630TB2669 Dead Front Arrester Installation Instruction

Effective March 2015 Supersedes S August 2002

COOPER POWER SERIES. QD8 Quik-Drive tap-changer VR or VL reversing switch stationary contact assembly kit number A48 installation instructions

COOPER POWER SERIES. D-73P3 bypass switches installation instructions. Switches MN008005EN. Effective April 2016 Supersedes S June 2013

COOPER POWER SERIES. EL Bay-O-Net Current-Limiting Fuse Installation Instructions. Fusing Equipment MN132023EN

COOPER POWER SERIES. 200 A 15/25 kv class elbow installation instructions. Deadbreak Apparatus Connectors MN650042EN

COOPER POWER SERIES. Manual or Hostick Operable, Padlockable 150 A Tap-Changer Switch Installation Instructions. Tap-Changer Switch MN800015EN

COOPER POWER SERIES. Series winding ratio test procedure instructions. Voltage Regulators MN225060EN. 120 Vac VOLTMETER

COOPER POWER SERIES. Under-oil arrester disconnector installation/operation instructions. OEM Equipment MN800010EN

COOPER POWER SERIES. UltraSIL Polymer-Housed Distribution-Class MOV Surge Arrester Installation Instructions. Surge Arresters MN235006EN

COOPER POWER SERIES. 600 A, 15, 25, and 35 kv Class Cleer Grounding Elbow Installation Instructions. Loadbreak Apparatus Connectors MN650056EN

COOPER POWER SERIES. VariSTAR Storm Trapper high energy MOV arrester installation instructions. Surge Arresters MN235017EN

COOPER POWER. SERIES VariSTAR type composite light-duty under-oil (CLU) MOV arrester installation instructions. Surge Arresters MN235023EN

COOPER POWER SERIES. UltraSIL polymer-housed VariSTAR surge arrester IEC for MV systems to 36 kv installation instructions

COOPER POWER SERIES. 50 A 2:1 series multiple (dual voltage) switch cap/wrench, lever or hotstick operable handles installation instructions

Effective May 2017 Supersedes July 2009 (S ) 600 A 35 kv Class T-OP II connector assembly installation instructions 200 A PROTECTIVE CAP LRTP

COOPER POWER SERIES. 600 A 35 kv class PUSH-OP deadbreak connector installation instructions. Deadbreak Apparatus Connectors MN650052EN

600 A 35 kv class PUSH-OP deadbreak connector installation instructions

COOPER POWER SERIES. 200 A 35 kv class LE series elbow installation instructions. Loadbreak Apparatus Connectors MN650010EN

COOPER POWER SERIES. Operation Counter Replacement Instructions. Reclosers MN280047EN. Effective May 2016 Supersedes S December 2003

COOPER POWER. SERIES VariSTAR type AZE station class surge arresters installation and maintenance instructions. Surge Arresters MN235022EN 0.

COOPER POWER SERIES. 200 A 15 and 25 kv class elbow with integral jacket seal* for use on tape and wire shielded cable installation instructions

COOPER POWER SERIES. 200 A 15 and 25 kv class elbow with optional integral jacket seal installation instructions. Loadbreak Connectors MN650008EN

Effective January 2017 Supersedes July 2011 (I ) VariSTAR Type AZG4 Surge Arresters Installation and Maintenance Instructions

S Surge Arresters

S Loadbreak Apparatus Connectors WARNING: WARNING:

Installation Instructions for the Walking Beam Interlock for Eaton EHD, FDB, FD, HFD, FDC, FW, HFW, FWC, Circuit Breakers and Molded Case Switches

COOPER POWER SERIES. Types E, 4E, V4E, H, 4H, V4H, L, and V4L single-phase recloser installation and operation instructions. Reclosers MN280051EN

COOPER POWER SERIES. VFI SF6-insulated vacuum fault interrupter installation, operation and maintenance instructions. Switchgear MN285004EN

INTRODUCTION BILL OF MATERIALS SPECIFICATIONS & TOOLS PROCEDURES OPERATION OF SEATPOST GIANT LIMITED WARRANTY

Norrsken Family Booklet

Operation Manual Enabling Pole-Top Communication Via the TripSaver II Magnet Tool

DISASSEMBLING & REASSEMBLING CARTRIDGE INSTALLING SEATPOST ON BIKE

Effective May 2017 Supersedes August 2005 (S )

3" UC Ultra-Chuck Durable Lightweight Air Inflated Bladder Chuck Operation/Repair Manual. (76.2 mm) DOUBLE E COMPANY, INC.

Cocoa Patio Pond with Lit Spillway

DEH Instructions. Three-Phase, Platform-Mounted Distribution Transformers

3M Liqui-Cel EXF-14x28 and 14x40 Series Membrane Contactor

ROPV R40 E Series User Manual

Booster Pump PB4-60 Replacement Kits

MAVERICK FOOSBALL TABLE

3M Liqui-Cel EXF-4x13 and 4x28 Series Membrane Contactors

Media-Isolated Mag Plus Probe Low Pressure-ISO Kit

S Surge Arresters. Handling and Storage. Standards. Acceptance and Initial Inspection

Model No Product Name Handpiece Only Complete System

Copyright Trek Bicycle Corporation 2005 All rights reserved

Vessel Installation and Operating Manual

USER MANUAL. DM65 Manual Flush/Tilt Combo Mount

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

Inspection Recommendations

Repair instructions. Pivot bushing replacement. XL-AS10001RM-en-DE Rev B

Pressure Dump Valve Service Kit for Series 2300 Units

ESA Elbow Sealing Adapter Kit

Teledyne Oil & Gas North Williamson Blvd. Daytona Beach, FL USA (phone) (fax)

Installation and Operating Manual

FLANGED TWO-PIECE BALL VALVES

This document to be used with Hurley traditional Davits

FLANGED TWO-PIECE BALL VALVES

6 & 8 Bubble Panel Installation Manual

For ELECTRIC ANCHOR WINCH Models: T Pontoon 35 T sw Salt Water Series Coastal 35

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP

1/2 Twin Hammer Composite. Air Impact Wrench ASSEMBLY AND OPERATING INSTRUCTIONS

Pressure Dump Valve Service Kit for Series 3000 Units

Installation, Operation & Maintenance Manual

Triple Tine Mechanical Grapple

OPERATING and MAINTENANCE INSTRUCTIONS MAXIS Grips

1 DRIVE INDUSTRIAL IMPACT WRENCH

DP Spare parts list. Demolition pulverizer. DP 2800 s/n DEQ Construction Tools GmbH No

deluxe toilet safety support

GRAVITY BIKE RACK ASSEMBLY & OPERATING INSTRUCTIONS

60 farm jack. Distributed exclusively by Harbor Freight Tools Mission Oaks Blvd., Camarillo, CA 93011

FACTORBIKES.COM. Assembly Manual V2.20

Installation, Operation and Maintenance Manual

SANTA CRUZ BICYCLES Cable Routing Procedure MY17

Operating Instructions for BAIR22-6 AIR-POWERED CRIMPING TOOL

COMPACT METAL bender 99826

PARK AVENUE 7' POOL TABLE WITH TABLE TENNIS & BENCHES ASSEMBLY INSTRUCTIONS

Operating Instructions

APPENDIX D HYDRO-VAC

Owner s Manual & Safety Instructions

3M Liqui-Cel EXF-10x28 Series Membrane Contactor

INSTRUCTION MANUAL. Includes: OPERATION SETUP USE & CARE SERVICE. SPORTS ATTACK LLC

3/8" Dr. Air Butterfly Impact Wrench

STYLE 3414/3416 & 3421/3423 Apollo Monitor with Foldaway Legs OPERATING & MAINTENANCE INSTRUCTIONS

INSTALLATION COMMISSIONING, OPERATION & MAINTENANCE MANUAL

J Air and Water Kit Instructions Part# 02584

RDK-408D2 Cold Head. Technical Manual. SHI-APD Cryogenics Inc Vultee Street Allentown, PA U.S.A. Revision A: September 2005

PHOENIX MMXI 7 FOOT 3 IN 1 BILLIARD TABLE

Arbor Terminator Press Operation Manual For IDT Connectors Order No Engineering No: AM

600 / 600FC OWNER'S MANUAL

Instruction Manual. Model TC1-S TopSide Clamp. top side clamp. For your personal safety READ and UNDERSTAND instructions before using tools.

Transcription:

Connectors Lorem ipsum and dolor Splices sit Amat Effective September 2014 Supersedes IS550-30-1 March 2011 MN650001EN DT400/436 Tee Connector Installation Instructions

DISCLAIMER OF WARRANTIES AND LIMITATION OF LIABILITY The information, recommendations, descriptions and safety notations in this document are based on Eaton Corporation s ( Eaton ) experience and judgment and may not cover all contingencies. If further information is required, an Eaton sales office should be consulted. Sale of the product shown in this literature is subject to the terms and conditions outlined in appropriate Eaton selling policies or other contractual agreement between Eaton and the purchaser. THERE ARE NO UNDERSTANDINGS, AGREEMENTS, WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILITY, OTHER THAN THOSE SPECIFICALLY SET OUT IN ANY EXISTING CONTRACT BETWEEN THE PARTIES. ANY SUCH CONTRACT STATES THE ENTIRE OBLIGATION OF EATON. THE CONTENTS OF THIS DOCUMENT SHALL NOT BECOME PART OF OR MODIFY ANY CONTRACT BETWEEN THE PARTIES. In no event will Eaton be responsible to the purchaser or user in contract, in tort (including negligence), strict liability or other-wise for any special, indirect, incidental or consequential damage or loss whatsoever, including but not limited to damage or loss of use of equipment, plant or power system, cost of capital, loss of power, additional expenses in the use of existing power facilities, or claims against the purchaser or user by its customers resulting from the use of the information, recommendations and descriptions contained herein. The information contained in this manual is subject to change without notice. ii

Contents SAFETY INFORMATION Safety Information...iv PRODUCT INFORMATION Introduction...1 Acceptance and Initial Inspection....1 Handling and Storage...1 Standards...1 INSTALLATION PROCEDURE Installation Instructions...2 iii

! SAFETY FOR LIFE Safety for life! SAFETY FOR LIFE Eaton s Cooper Power Systems products meet or exceed all applicable industry standards relating to product safety. We actively promote safe practices in the use and maintenance of our products through our service literature, instructional training programs, and the continuous efforts of all Eaton s Cooper Power Systems employees involved in product design, manufacture, marketing, and service. We strongly urge that you always follow all locally approved safety procedures and safety instructions when working around high voltage lines and equipment, and support our Safety For Life mission. Safety information The instructions in this manual are not intended as a substitute for proper training or adequate experience in the safe operation of the equipment described. Only competent technicians who are familiar with this equipment should install, operate, and service it. A competent technician has these qualifications: Is thoroughly familiar with these instructions. Is trained in industry-accepted high and low-voltage safe operating practices and procedures. Is trained and authorized to energize, de-energize, clear, and ground power distribution equipment. Is trained in the care and use of protective equipment such as arc flash clothing, safety glasses, face shield, hard hat, rubber gloves, clampstick, hotstick, etc. Following is important safety information. For safe installation and operation of this equipment, be sure to read and understand all cautions and warnings. Hazard Statement Definitions This manual may contain four types of hazard statements: DANGER Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. WARNING Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. CAUTION Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. CAUTION: Indicates a potentially hazardous situation which, if not avoided, may result in equipment damage only. Safety instructions Following are general caution and warning statements that apply to this equipment. Additional statements, related to specific tasks and procedures, are located throughout the manual. DANGER Hazardous voltage. Contact with hazardous voltage will cause death or severe personal injury. Follow all locally approved safety procedures when working around high- and low-voltage lines and equipment. G103.3 WARNING Before installing, operating, maintaining, or testing this equipment, carefully read and understand the contents of this manual. Improper operation, handling or maintenance can result in death, severe personal injury, and equipment damage. G101.0 WARNING This equipment is not intended to protect human life. Follow all locally approved procedures and safety practices when installing or operating this equipment. Failure to comply can result in death, severe personal injury and equipment damage. G102.1 WARNING Power distribution and transmission equipment must be properly selected for the intended application. It must be installed and serviced by competent personnel who have been trained and understand proper safety procedures. These instructions are written for such personnel and are not a substitute for adequate training and experience in safety procedures. Failure to properly select, install or maintain power distribution and transmission equipment can result in death, severe personal injury, and equipment damage. G122.3 iv

Product Information Introduction DT400/436 Tee Connector Kit from Eaton's Cooper Power Systems is a premoulded separable connector designed for connection of polymeric (XLPE, EPR, etc.) cable to transformers, switchgear, motors and other electrical apparatus. It can be used indoors or outdoors in installations up to 36 kv requiring a continuous current rating of 630 A or less, where the mating bushing complies with CENELEC standard EN50180, Interface C. Read This Manual First Read and understand the contents of this manual and follow all locally approved procedures and safety practices before installing or operating this equipment. Additional Information These instructions cannot cover all details or variations in the equipment, procedures, or process described nor provide directions for meeting every possible contingency during installation, operation, or maintenance. For additional information, contact your representative. Acceptance and Initial Inspection Each elbow is in good condition when accepted by the carrier for shipment. Upon receipt, inspect the shipping container for signs of damage. Unpack the elbow and inspect it thoroughly for damage incurred during shipment. If damage is discovered, file a claim with the carrier immediately. Figure 1. 630 A deadbreak bolted tee connector. Handling and Storage Be careful during handling and storage of the elbow to minimize the possibility of damage. If the elbow is to be stored for any length of time prior to installation, provide a clean, dry storage area. Standards ISO 9001 Certified Quality Management System 1

Installation instructions Complete Tee Connector kit includes: 1 Moulded tee connector 1 Clamping screw 1 Basic insulating plug 1 Rubber cap 1 Cable adapter 1 Bi-metallic conductor contact Silicone lubricant Paper towel Installation instructions WARNING Hazardous voltage. All associated apparatus must be de-energized during installation and/or maintenance. Failure to comply may result in death, severe personal injury and equipment damage. SCREEN WIRES 435 mm VINYL TAPE INSULATION SCREEN 100 mm Figure 2. Step 1 1. Train the cable to the desired finished position. (See Figure 2.) Be sure that the cable is long enough to permit movement of the tee connector from the apparatus bushing to a standoff bushing. 2. Initially, cut the cable 100 mm past the bushing centerline. Note: This is the initial length of the cable to ensure that the screen wires are long enough to reach the earthing eye on the tee connector. The cable will be cut to its final length in a later step. 3. Remove 435 mm of the cable sheath. 4. Fold the screen wires back over the sheath and secure them with two wraps of vinyl tape. (This step is optional. The vinyl tape is not included in the kit.) 5. Position the cable to its final position and cut it 50 mm from the centerline of the apparatus bushing. See Figure 3. 2

Step 2 1. Remove 225 mm of the insulation screen. 2. Remove 77 mm of core insulation. 3. Cut a 45 chamfer onto the end of the cable insulation. INSULATION 225 mm CHAMFER 77 mm Figure 3. Removal of insulation. 50 mm CONDUCTOR 4 3 2 1 Figure 5. Insertion of conductor into crimp barrel. Step 5 1. Clean the outer surface of the cable adapter and the interior of the cable end of the tee connector with a lint-free cloth. Apply a thin layer of lubricant to both surfaces. 2. Push the tee connector over the cable adapter as far as it will go. Ensure that the hole in the top of the crimp connector is visible through the interface end of the tee. 3. Connect one of the screen wires to an earthing eye on the tee connector. Step 3 1. Thoroughly clean the core insulation, using a suitable cleaner and a lint-free cloth. 2. Wrap several layers of electrical tape over the end of the conductor. 3. Apply a thin layer of lubricant to the core insulation and the inside diameter of the cable adapter. 4. Slide the cable adapter onto the cable, black end first, until the grey end is 85 mm from the end of the cable. Remove the electrical tape from the conductor. Tape (Remove before next step) 85 mm Figure 4. Cable adapter insulation. Step 4 1. If the conductor is aluminum, thoroughly wire brush the exposed conductor. 2. Immediately insert the conductor into the crimp barrel as far as it will go. Ensure that the flat of the copper face is parallel to the face of the bushing. 3. Crimp the connector starting at the shoulder, as shown. Rotate the crimping tool 90 for each successive crimp. 4. Remove any inhibitor that may come out of the crimp connector. 3

Step 6 1. Clean the bushing interface and the tee interface and apply a thin layer of lubricant to each. 2. Push the tee connector onto the bushing. Step 8 1. Clean and apply lubricant to the insulating plug and the tee connector interface. 2. Insert the insulating plug into the connector and engage the threads of the clamping screw. 3. Tighten the insulating plug to a torque of 40 Nm (30 ft-lbs), using a torque wrench and 24 mm socket wrench. CLEAN AND LUBRICATE DT400 24 kv Figure 6. Installation of tee connector onto bushing. Step 7 1. Insert the long threaded end of the clamping screw through the hole of the crimp connector and into the threaded hole of the bushing, taking care to avoid cross-threading. 2. Tighten the clamping screw to a torque of 50 Nm (37 ft-lbs) using a 22 mm socket wrench. DT400 24 kv DT400 24 kv Figure 8. Installation of insulating plug. Figure 7. Installation of clamping screw. 4

Step 9 1. Clean the interior surface of the rubber cap. 2. Place it over the insulating plug and push it until it snaps into place. DT400 24 kv Figure 9. Installation of cap. CAUTION The apparatus bushing and tee connector should not support the weight of the cable. Clamp the cable immediately below the cable screen adapter. Failure to comply may result in equipment damage. 5

This page is intentionally left blank. 6

This page is intentionally left blank. 7

! SAFETY FOR LIFE Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com Eaton s Cooper Power Systems Business 2300 Badger Drive Waukesha, WI 53188 cooperpower.com 2014 Eaton All Rights Reserved Printed in USA Publication No. MN650001EN / Rev 00 Eaton and Cooper Power Systems are valuable trademarks of Eaton, in the U.S. and other countries. You are not permitted to use these trademarks without the prior written consent of Eaton.