Check Valves. Pilot Operated Check Valves. Vickers. 4CG-10, 20 Series 4CS-03, 20 Series 4CT-06/10, 20 Series. Basic Characteristics.

Similar documents
VICKERS. SystemStak Valves. ISO ; NFPA-D03; 315 bar (4500 psi); 60 L/min (15.7 USgpm) GB 2027B

Directional Controls

Vickers. Flow Controls. Flow Controls FN, F(C)G, FRG. Released 6/94

Directional Controls

PRESSURE REDUCING (AND CHECK) VALVES RT/RG RCT/RCG. -03/06/10 (3/8, 3/4, 1-1/4) Threaded Connections / Sub-plate Mounting

Flow Controls. DG**-06 Series Stacking Valves. Vickers. ISO (D06) Interface Flows to 340 l/min (90 USgpm) Pressure to 210 bar (3000 psi)

IN-LINE CHECK VALVES CIT-02 / 03 / 06 / 10 (1/4,3/8,3/4,1-1/4) RIGHT ANGLE CHECK VALVES CRT / CRG-03 / 06 / 10 (3/8,3/4,1-1/4)

Logic Elements Screw-in Cartridge Valves Pressures to 290 bar (4200 psi) Flows to 303 l/min (80 USgpm)

Pressure reducing valve, pilot operated, Model 3DR

Pilot Operated Check Valves

Prop. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08

Manapak Sandwich Valves Series CM, CPOM, FM, PRDM, PRM, RM

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R

Pressure reducing valve, direct operated

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R

Double Pilot Operated Cartridge Check Valve, Size 8

Directional Control Valves Technical Information Model 1500

Cover headline. Cover subheadline. Check Valves

2-way flow control valve Model 2FRM 6

ENGINEERING DATA. PVB Piston Pumps. w w w. F l u i D y n e F P. c o m Same Day Shipments of Units or Part Orders

PRESSURE COMPENSATORS TECNORD

SystemStak Valves. ISO4401 Size 02

Pressure reducing valve, direct operated

Check valve hydraulically pilot operated

PRESSURE SEQUENCE VALVE TYPE UZK

Displacement 12, , Maximum flow rate (at 1450 rpm) bar.

PVQ 13 A2 R SE 1 S 20 C-11 D

P2* MODULAR SUBPLATES FOR ISO (CETOP 03) VALVES

Load Controls Screw In Cartridge Valves Pressures to 350 bar (5000 psi) Flows to 190 l/min (50 USgpm)

Auxiliary valve QDS6 Sequence valve, 3-way. Catalogue (GB) (US) October 1998

Pressure reducing valve, pilot operated

E 094 E 103 E 143 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 135 l/min / 35.7 gpm

E Series Piston Pumps Variable Displacement Series for Mobile Applications Technical Catalog PVE012 PVE19 PVE21

Electrically Operated Pressure-Relief Cartridge, Size 10

Min. Metered Flow Capacity L/min. Max. Oper. Pressure Kgf/cm (0.04)* F- FC G N -11 H01. Max. Metered Flow Capacity L/min.

Pilot Operated Check Valves Catalog Quick Reference

Directional Valves. Hydraulic Operated Directional Valves

WK /2 WAY CARTRIDGE VALVE TYPE URZS 32 COVER FOR CARTRIDGE VALVE TYPE ULZS 32. Size 32 up to 42 MPa 700 dm 3 /min DESCRIPTION OF OPERATION

3-Way Pressure-Reducing Cartridge, Size 2 4

Cartridge Valves Technical Information. Pilot operated check valves. Quick reference

Pressure-Relief Cartridge Valve, Size 4

DENISON HYDRAULICS vane pumps - single, double T6G - T67G - T6ZC

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US

Proportional Throttle Cartridges, Size 16

MECHANICALLY OPERATED DIRECTIONAL VALVES Rotary Type : DRT/DRG-02 Cam Operated : DCT/DCG-01, 03 Threaded Connection/Sub-plate Mounting

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Inverse Prop. Pressure-Relief Cart., Size 2 4

Digital relief valves D-CG

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm

E SERIES. Specification. E Series. Relief and Flow Control Valves O M O M EIC-H Model No. Description

HYDRAULIC MOTORS MTM APPLICATION OPTIONS CONTENTS EXCELLENCE GENERAL

Full Range Pressure Compensating Variable Flow Control

E 084 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 80 l/min / 21.1 gpm

E 212 E 222 Tank top mounting Connection up to G1¼ / -20 SAE Nominal flow rate up to 220 l/min / 58.1 gpm

APPLICATION. Conveyors Metal working machines Machines for agriculture Road building machines Mining machinery Food industries

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R

Leak free Pipe Rupture Valve for Excavators

BW0500AO. ByWire Elements BW0500AO Element 4/3 with side ports IBW0500 Interface

Inverse Proportional Pressure-Relief Cart., Size 2 4

Inverse Proportional Pressure-Relief Cart., Size 2 4

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Hand & mechanical directional valves

Function. Valve Size. Pilot Oil. p min. Bold: Designates Tier I products and options.

RE / Meter out pressure compensator Sandwich plate design Type SCA... /Series 2X. Description of function, Section 1/6. Replaces: 09.

Cooler-Bypass Thermostat Valve, Size 16

Inverse Proportional Pressure-Relief Cartridge, Size 10

HIGH PRESSURE FILTERS DFDK Series Inline Duplex Filters 4568 psi up to 90 gpm

shutoff valves 900 Series psig Manual Shutoff Valves

Desiccant Air Breathers DBE. Section 3: TNK SCHROEDER INDUSTRIES ACCESSORIES 21

Pressure Control (and Check) Valve

Dual displacement motor A10VM Plug-in dual displacement motor A10VE for open and closed circuit applications

Pilot operated check valves 4CG

Pressure relief valve, direct operated

005 Series Modular Valves

OMS Technical Information Technical data

Principles of Filtration. Filter Elements. High Pressure Filters. Section 4. Tank-Mounted, Return Line and Medium Pressure Filters

Axial piston pumps type PVC

Orbital Motors Type OMP X and OMR X

Cartridge Valves Technical Information. Pressure Reducing, Quick Reference

Pilot operated pressure relief valve sandwich plate,type ZDB/Z2DB6 Huade América 1

Axial piston pumps type PVC

PLD 03 T A CASAPPA S.p.A.

HYDRAULIC MOTORS MV APPLICATION GENERAL

OMS Technical Information. Versions OMS. Versions

Orbital Motors Type OMP, OMR and OMH. Technical Information

Pressure Reducing Valves Catalog Quick Reference

4/3 Directional valve elements L8_P5 with proportional (ED-IP) control and with or without LS connections L8_P5 (ED-IP)

420 Mobile Piston Pump Design Code B

Pressure control. Direct and pilot operated pressure control valves for applications up to 350 bar (5000 psi) and 300 L/min (80 USgpm)

20 to 280l/min 21MPa. econnecting a remote control valve to the vent port allows remote control of adjustment pressure.

4/3 Directional valve elements L85L1...(EDC-LV) with manual lever operated control with flow sharing control (LUDV concept) L85L1...

Pressure relief valve, direct operated Type DBD

CV08-20 Check Valve DIRECTIONAL VALVES. DESCRIPTION A screw-in, cartridge-style, hydraulic check valve for use as a blocking or load-holding device.

Proportional Two-Stage Directional Valves Servo Performance with Double Spool Feedback. KBHDG5V-5/7/8/10 12 Design Pressures to 350 bar (5000 psi)

E 328 E 498 Tank top mounting Connection up to G1½ and SAE 2 Nominal flow rate up to 600 l/min

Pressure reducing valve, direct operated, type DR 5 DP Huade América 1

directional control valve series cv691

DENISON HYDRAULICS T6 industrial application

FIK In-Tank Filters FIK. Max Flow: 170 gpm (643 lpm) Working Pressures to: Rated Static Burst to: Flow Range to:

Transcription:

Vickers heck Valves Operated heck Valves 4G-10, 20 Series, 20 Series 4T-06/10, 20 Series Typical Section 4T1-06-D*-20-U, illustrating external drain and decompression features asic haracteristics Maximum pressure..... Up to 210 bar (3000 psi) Nominal flow rate..... Up to 280 L/min (74 USgpm) Mounting: 4G-10 models.... Subplate/manifold models.... 3 / 4-16 UNF, SAE 4T-06 models...... G 3 / 4 ( 3 / 4 SPF) 4T-10 models.... G1 1 / 4 (1 1 / 4 SPF) General Description These pilot operated check valves operate as standard check (non-return) valves in one direction, but can also be opened by a remote pilot pressure signal to permit reverse flow. Functional Symbols 4G 4S/T An optional decompression feature (used in conjunction with appropriate pilot pressures) provides for the controlled decompression of large volumes of pressure fluid before the valve opens to allow full flow. See catalog 2329 for other subplatemounted pilot operated check valves for pressures up to 350 bar (5000 psi) and flow rates up to 300 L/min (80 USgpm) and with integrally mounted solenoid operated pilot valves. 4G1/2 4T1 April 1996 G-2340A

Model odes Features in brackets ( ) may be omitted. All other features must be specified. For Subplate-Mounted Model (F3-)4G (*)-10-(D) * - 2* -UG 1 2 4 5 6 For Thread-Mounted Models Size 03: (F3-)- (D) * - 2* 1 4 5 6 Sizes 06 and 10: (F3-) 4T (1)-**- (D) * -2* -U 1 2 3 4 5 6 1 Fluid compatibility lank = Antiwear hydraulic oil (class L-HM), invert emulsion (L-HF) or water glycol (class L-HF) F3 = As above or phosphate ester (class L-HFD) 6 Design number, 2* series Subject to change. Installation dimensions unaltered for design numbers 21-29. 2 piston external drain option (Not available on models) 1 = Drain through lower cover For 4G*-10 model only: 2 = Drain through interface port 3 Nominal size For 4T models only: 06 = 3 / 4 nominal bore pipe size 10 = 1 1 / 4 nominal bore pipe size 4 Decompression feature Omit D if not required 5 A F racking (opening) pressure = 2 bar (30 psi) = 3,4 bar (50 psi) (except 4*-10) = 5 bar (75 psi) = 10 bar (150 psi) 2

Operating Data Maximum pressures All ports, all models Nominal flow rates: 4T-06 4T-10, 4G-10 210 bar (3000 psi) racking (opening pressure) See Model ode 5 pressures Area ratios piston to check valve:, 4T-06 4T-10, 4G-10 piston to decompression poppet: 4T-06 4T-10, 4G-10 45 L/min (12 USgpm) at p 1,7 bar (25 psi) 114 L/min (30 USgpm) at p 2,8 bar (40 psi) 284 L/min (75 USgpm) at p 3,4 bar (50 psi) See Pressures below 3,5:1 2,6:1 33,8:1 52,6:1 77,0:1 Hydraulic fluids See Model ode and Hydraulic Fluids 1 Temperatures Ambient: Min. Max. Fluid temperatures For 4G model only: Subplate Mounting bolts Mass (weight): 4T-06 4T-10 4G-10 20 (4 F) +70 (158 F) See Fluid Temperatures E-RXGM-10(X), see page 6 See Installation Data 2,8 kg (6.2 lb) 5,7 kg (12.5 lb) 12,1 kg (26.7 lb) 11,9 kg (26.2 lb) Hydraulic Fluids All valves can be used with the fluids specified in Model ode 1. Prefix F3- must be specified to obtain seals suitable for operation with phosphate esters (not alkyl based). The extreme operating viscosity range is from 13 to 860 cst (70 to 4000 SUS), but the recommended running range is 13 to 54 cst (70 to 245 SUS). For further information about fluids see leaflet 920. ontamination ontrol Requirements Recommendations on contamination control methods and the selection of products to control fluid condition are included in Vickers publication 9132 or 561, Vickers Guide to Systemic ontamination ontrol. The book also includes information on the Vickers concept of ProActive Maintenance. The following recommendations are based on ISO cleanliness levels at 2 m, 5 m and 15 m. For products in this catalog the recommended levels are: Up to 210 bar (3000 psi) 19/17/14 Fluid Temperature Water- containing Petroleum oil Pressures The pilot pressure required to open the check valve or decompression poppet is stated as a ratio of the pressure on the check to the pilot pressure. To determine the required pilot pressure the following formulae should be used. For internally drained pilot piston models, no symbol at model code 2 : pressure P out P in Area ratio P in Model 4T-06 4T-10 4G-10 factor for cracking pressure, model code 5 A F 0,6 0,6 0,8 0,8 1,0 1,0 2,0 2,0 1,5 1,5 4,0 3,0 4,0 4,0 For externally drained pilot piston models, 1 (or 2 for 4G) at model code 2 : pressure P out Area ratio Where: P in = Pressure (bar) at free flow inlet P out = Pressure (bar) at free flow outlet = Varies according to model/ cracking pressure, see table. Min. 20 +10 (4 F) (50 F) Max.* +80 +54 (+176 F) (130 F) * To obtain optimum service life from both fluid and hydraulic system 65 (150 F) normally is the maximum temperature except for water-containing fluids. For synthetic fluids consult manufacturer or Vickers representative where limits are outside of those for petroleum oil. Whatever the actual temperature range, ensure that viscosities stay within the limits specified under Hydraulic Fluids. 3

Installation Dimensions in mm (inches) and 4T(1)-06/10 Pipe-Mounted Models 3rd angle projection E F D E A Free flow outlet, or reverse controlled flow inlet (Gage port 1). Thread K. J Pressure gage ports, all models: 7 / -20 UNF-2, SAE O-ring ports Gage port 1 Gage port 2 G Free flow inlet, or reverse controlled flow outlet (Gage port 2). Optional ports. Thread K. For 4T1-06/10 models only: External drain connection G 1 / 8 M H L pressure connection: : 9 / -18 UNF-2, SAE O-ring port All others: G 1 / 4 Model A D E F G H J K L M 4T(1)-06 4T-10 4T1-10 122 (4.8) 178 (7.0) 194 (7.6) 204 (8.03) 70 (2.76) 93 (3.66) 70 (2.76) 89 (3.5) 35 (1.38) 50,8 (2.0) 86,4 (3.4) 86,4 (3.4) 60 (2.36) 75 (2.95) 99 (3.9) 99 (3.9) 40 (1.57) 50,8 (2.0) 68,3 (2.69) 68,3 (2.69) 53 (2.09) 78 (3.07) 84 (3.31) 94 (3.7) 57 (2.24) 70 (2.76) 95 (3.74) 95 (3.74) 23,1 (0.91) 26,9 (1.06) 28,9 (1.14) 28,9 (1.14) 3 / 4-16 UNF-2 G 3 / 4 (SPF) G1 1 / 4 (SPF) G1 1 / 4 (SPF) 45,2 (1.78) 57,2 (2.25) 70,6 (2.78) 82 (3.23) 42,7 (1.68) 54,6 (2.15) 4

4G(*)-10, Subplate-Mounted Models 3rd angle projection 6 holes Ø10,8 (0.425 dia) thru, counterbored Ø17,0 (0.67 dia) to dimension F for mounting bolts. Mounting surface (seals supplied) A Free flow outlet or reverse controlled flow inlet (Gage port 1) Location pin Gage port 1, G 1 / 4 pressure connnection D G Gage port 2, G 1 / 4 E Free flow inlet or reverse controlled flow outlet (Gage port 2) F For 4G1 models only: External drain G 1 / 8 When using 4G-10 or 4G1-10 models, plug this connection at the subplate or at the mounting face (e.g. do not drill matching hole in subplate/ manifold block). Model A D E F G 4G-10 4G*-10 194 (7.64) 204 (8.03) (4.65) (4.65) 100 (3.93) 100 (3.93) 55 (2.17) 65 (2.56) 48,4 (1.91) 48,4 (1.91) 95,3 (3.75) 95,3 (3.75) 26 (1.0) 5

E-RXGM-10(X) Subplate For 4G (*)-10 Models For external drain connection for 4G2 models only: Ø4,8 (0.19 dia) at mounting face; G 1 / 4 on rear face When used for 4G or 4G1 models this connection must be plugged. 11,2 (0.44) 20,6 (0.81) 138,1 (5.43) 3,97 (0.16) 161,0 (6.34) 96,83 (3.81) When a subplate is not used, a machined pad (as indicated by shaded area) must be provided for mounting. The pad must be flat within 0,013 mm (0.0005 in) and smooth within 1,6 m (63 microinch). Mounting bolts provided by the customer should be lass 12,9 (ISO 898) or better. 2 holes Ø7,1 (0.28 dia) x 7,9 (0.31) deep for location pins 67,5 (2.66) 59,5 (2.34) 42,1 (1.66) 24,6 (0.97) (2) OUT IN (1) 62,71 (2.47) 84,1 (3.31) 95,4 (3.76) 147,0 (5.79) 16,9 (0.67) 6 holes tapped M10 x 24,0 (0.94) deep at mounting face Ø17,0 (0.67 dia) 21,49 (0.85) 48,4 (1.91) 92,86 (3.65) 119,3 (4.7) 11,2 (0.44) 31,4 (1.24) External pilot pressure connection: Ø4,8 (0.19 dia) at mounting face; G 1 / 4 on rear face Main ports on rear face; 2 holes Ø28,6 (1.125 dia) at mounting face 12,0 (0.47) 22,4 (0.88) 47,75 (1.88) Ø10,8 (0.425 dia) 2 holes tapped A Model A E-RXGM-10-20R E-RXGM-10X-20R G1 1 / 4 (1 1 / 4 SPF) G1 1 / 2 (1 1 / 2 SPF) 76,2 (3.0) 78,1 (3.1) 7,9 (0.31) 6,0 (0.24) Pin at location (1) for pilot operated check valves; at location (2) for pressure reducing valves. Installation Data Mounting Attitude No restrictions Mounting olts olt kit.............. KRX-10-662M If not using Vickers recommended bolt kit, bolts used should be to ISO 898 class 12,9 or better. Recommended bolt torque..... 49-59 Nm (36-44 lbf ft) Ordering Procedure Specify full model code. 6