What we have learned over the years Richard Williams I Sales Manager

Similar documents
Operating Manual for the Evance Iskra R9000 Wind Turbine

Covered Task 409OP Training Guide Inspecting Interference Bonds

THE FUTURE OF WATER IS WIRELESS

Cathodic Protection Retrofit Options Comparison of Current Distribution

ASSE International Product (Seal) Listing Program

Florida Building Code 6 th Edition (2017) Residential. Broward County Edition Loose-leaf Supplement

sdfghjklzxcvbnmqwertyuiopasdfghjklzxcvbnmqw ertyuiopasdfghjklzxcvbnmqwertyuiopasdfghjklzx

These Instructions apply to all low-voltage installations where Operations Manager HV in Statnett has authority as Operations Manager LV.

Recent Developments in Pressure Management

References 6 k thermal overload relays, adjustable from 0.11 to 16 A

Certificate of compliance

AN ISOLATED SMALL WIND TURBINE EMULATOR

LAKE BLUFF PARK DISTRICT BLAIR PARK SWIMMING POOL Questions and Answers OVERVIEW

IST-203 Online DCS Migration Tool. Product presentation

Installation, use and maintenance instructions. Gas burner (5)

Wade Reynolds 1 Frank Young 1,2 Peter Gibbings 1,2. University of Southern Queensland Toowoomba 4350 AUSTRALIA

Status Date Prepared Reviewed Endorsed Approved

Bringing Pressure Under Control: Harnessing Control Valves for Intelligent Water Networks. A Report on Best Practice from TALIS

Survey of Underwater NDT Technologies for Offshore Assets

ServicePlus S21R & S27R Series 2 Installation Instructions

Electrical Shore Connections

PIKO IQ 4.2, Plenticore plus 4.2 Rating: 10,0kW 8,5kW 7,0kW 5,5kW 4,2kW Rated voltage: PIKO IQ 8.5, Plenticore plus 8.5

Computer Operator Instructions. Extra Instructions for High School District Championship Meets

ANNUAL RELIABILITY AND POWER QUALITY REPORT for the year ended 30 June 2017

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

Products for Cryogenic Applications

INSTALLATION PROCEDURE 1/4 & 1/8 MILE PERMANENT TRACK

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

ES18 Security Theory/Regulations Answer Schedule

Metham Aviation Design Limited, Station Approach, Four Marks, Alton. Hants. GU34 5HN Tel +44 (0) Fax +44 (0)

AC or DC Transmission for a Remote Wind Farm?

Energy Networks Management Safety Procedures DEFINITIONS

Site Safety & National Transmission Pipeline Marker Signs

Best Practice RBI Technology Process by SVT-PP SIMTECH

RUNNING - HIGH KNEE-LIFT RUN

2013 Special Reliability Assessment: Accommodating an Increased Dependence on Natural Gas for Electric Power

BPZM-MRD Nitrogen Injection System

Team Ram-Rod. Rod. Aaron Gardiner Tyler Murphy Vivian Phinney Farheen Rizvi Ali Toltz

1 st Tidal and Water Level Working Group Meeting DHN, Niteroi, Brazil 31/03/09 02/04/09 Vertical Offshore Reference Framework (VORF) Chris Jones

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

Sorensen DCS Series. 1 3 kw V A. General Purpose Systems Power Supply

Sharing practice: OEM prescribed maintenance. Peter Kohler / Andy Webb

Check with local zoning official for property line distance requirements.

UNIVERSITY OF CAMBRIDGE INTERNATIONAL EXAMINATIONS International General Certifi cate of Secondary Education

Tennis Victoria Club Guide Coach Relationship

Quarries National Joint Advisory Committee (QNJAC) Occupational Health. Information Sheet 7. October Whole Body Vibration

Product Overview. Product Description CHAPTER

Second Generation Charging Station

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

A SURVEY OF THE RELIABILITY OF HVDC SYSTEMS THROUGHOUT THE WORLD DURING On behalf of Study Committee B4

About us. Try us to trace your network!

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter

SCIENCE LAB UTILITY CONTROLS

Health and Safety Executive. Key aspects of HS(G) 253. Andrew Hall HID CI 1G. HM Specialist Inspector (Mechanical)

Unit 24: Applications of Pneumatics and Hydraulics

ACCURATE PRESSURE MEASUREMENT FOR STEAM TURBINE PERFORMANCE TESTING

Key Features & Advantages of JEHA MK IV (5,000 PSI Hydraulic Test Stands)

COMPANY PROFILE. Sales to 90 countries worldwide

CENTRAL GAS SUPPLY SYSTEMS : CYLINDER BATTERIES AND HIGH PRESSURE HOSES

SAFETY PRECAUTIONS FOR THE BLACK BEARD S BEACH WATER PARK

<:\_J Senior Manager- Safety, Security & Emergency Response. Ell ORIGINAL DELIVERED BY COURIER. June 7, 2017

STAND alone & p.c. VERSION

Electrical Equipment for Hazardous Areas GNEM1

A comprehensive approach to monitor weight of fire extinguishing agent

IALA World-Wide Academy. Model Course For. Aids to Navigation. Level 2 Technician Training

IP Track Delivery Update The Railway Correspondence and Travel Society. 4 September 2014 Steve Featherstone

Copeland Discus with CoreSense Diagnostics January 2011

CIRCUIT BREAKER TESTING - JOB SAFETY ANALYSIS

Connect with Confidence NO POWER NO PROBLEM

IntelliChlor Power Center (For use with IntelliChlor model IC60, IC40 and IC20)

Yokosuka Cruise Report YK11-02

URC Voltage Sensor SEN-VOLT for use with MRX units containing sensor ports

A i r c r a f t E l e c t r i c a l S y s t e m s ( 1 2 B )

MAKING ELECTRICAL A GUIDE ON HOW TO INSPECT AND TEST PORTABLE APPLIANCES SAFELY AND EFFECTIVELY

Polatrak ROV II - Tip Contact Probe Operation Manual

CO, NO, NO 2, NO x, SO 2, CH 4, HCl, CO 2 & H ² O. Extractive low cost, low maintenance devices for continuous process and emissions monitoring.

Project Single Points of Failure

Galaxy Shore Connection 500 kva Installation 04/

REMOTE WATER LEVEL MONITORING

C&G Level 3 Award in the Periodic Inspection, Testing and Certification of Electrical Installations

Type Operating Instructions. 2/2-way solenoid valve 2/2-Wege Magnetventil Electrovanne 2/2 voies.

Electrical. OSHA Office of Training and Education 1

EasyTouch. Because automation makes it all so simple. Pool and Spa Control Systems. By Pentair Water Pool and Spa

EasyTouch. Pool and Spa Control Systems By Pentair Water Pool and Spa. Because automation makes it all so simple

Visualize Nitrogen Gas Consumption

Vortex flowmeters. Product family introduction Principle of operation Product review Applications Key product features

Lecture 04 ( ) Hazard Analysis. Systeme hoher Qualität und Sicherheit Universität Bremen WS 2015/2016

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL ACCUMULATORS. This work covers part of outcome 2 of the Edexcel standard module:

Applied Pressure Management Techniques to Reduce and Control Leakage

NATIONAL TRAINING CENTER COURSE CATALOG

EasyTouch. Because automation makes it all so simple. Pool and Spa Control Systems. by Pentair Water Pool and Spa

PSSI 1 High Voltage Switching

kēlo LED Light Installation Instructions

User Manual MFCS TM -EZ

Section Freepoint Service 26.1 FREEPOINT CONTROL PANEL

frequently asked questions

Transport Workshop Dearbhla Lawson Head of Transport & Infrastructure Policy & Funding University of the Third Age.

Sewable LED kits Teaching Notes Issue 1.1

Potter Nitrogen Generators

PSSI 3 High Voltage Metal-Enclosed Switchgear

Transcription:

Subtitle Content Specialists in Remote Monitoring Benefits of Remote Synchronised Interruption What we have learned over the years Richard Williams I Sales Manager Slide: 1: #

Agenda 1. Overview of MERLIN Monitoring applications 2. Benefits of Remote Synchronised Interruption for above ground surveys 3. New benefits of Remote Synchronised Interruption 4. Lessons learned over the years Slide: 2: #

In The Beginning Transformer Rectifier Monitor Output Voltage Output current ON / OFF potentials at the TR Test Post Monitor ON Potential Instant OFF potential Coupon Current AC and DC measured Slide: 3: #

Remote Monitoring Advantages Proactive Cathodic Protection monitoring Increase in the effectiveness of Cathodic Protection Schemes Understanding of vulnerable points of the pipeline Reliable readings Compliance with HSE requirements Auditable recorded results using the CPSM database Slide: 4: #

Further Applications Sleeve Integrity Isolation Joints Critical bonds Sacrificial Anodes Nitrogen Filled Sleeve Monitoring Satellite communications for the TR Monitors icpsm Internet based Remote Synchronised Interruption. Slide: 5: #

Interrupting Pipelines For Above Ground Surveys Extremely time consuming Synchronised via Rugby Clock or internal circuit timing Battery failures Pipelines can be very long Unreliable method of synchronisation Slide: 6: #

Tackling The Challenges Time consuming methods. Permanently fitted Interruption solution No need to install unreliable standalone current switching devices Timing GPS Accurate to 1 m/s Battery failures Permanent installation Remote Switching icpsm Scheduled Interruption Solid State Relay Slide: 7: #

Software Features Slide: 8: #

Typical Installation Slide: 9: #

New benefits Pipelines will be in separate schemes Surveys carried out on smaller sections Slide: 10 : #

Example Network Picture of AGI with pipelines and TR s on each section Slide: 11 : #

Example Network Slide: 12 : #

New Advantages Interconnected CP system will allow the schemes to support each other Potential for less Transformer Rectifiers on the pipelines Potential for less ground bed installations Electrical connection of pipelines would not be typical Slide: 13 : #

Pipelines Electrically Connected Slide: 14 : #

Pipelines Electrically Connected Slide: 15 : #

New Concepts Deep well technology for ground beds More efficient ground beds Drill on Networks AGI Slide: 16 : #

Illustration Of Deep Well Ground Bed Slide: 17 : #

Deep Well Drilling At An AGI Content Slide: 18 : #

Reducing Challenges Land owner permission Landowner payments Third party agency payments Existing AC power Slide: 19 : #

What does this mean? Two distinct outcomes: Save Money! Up to 50% can be saved per installation Save time! Months can be saved in installations Slide: 20 : #

Lessons Learned by this GDN Eliminated monthly functional checks Conversion of Anode Systems Would require monitoring Cost savings to not visiting The data has to be managed effectively More issues have been realised and fixed Direct workforce can concentrate on more CP related tasks Slide: 21 : #

Questions Slide: 22 : #