Liquid Handling Systems

Similar documents
Technical Procedure for General Laboratory Equipment

Automated Liquid Handling Station

Instructions for Assembly, Installation, and Operation of the Gas Addition Kit Accessory with the CEM Discover Systems

PREPARED BY: Marshall K. Cheung, Ph.D., Laboratory Director. REVISED BY: Marshall K. Cheung, Ph.D., Laboratory Director

Automated Determination of Dissolved Gases in Water Anne Jurek. Abstract: Discussion:

Toxicology Gas Chromatography-Mass Spectrometry (GC-MS)

GCMSD-Headspace Analysis SOP

HemoCue Hb Procedure Template

SOP: Buck Scientific BLC-20P HPLC Operation

MSD 96-Well MULTI-ARRAY and MULTI-SPOT Human Granulocyte Colony Stimulating Factor (hg-csf) Ultrasensitive Assay

Endo-Flush Order # ZUTR30004 OPERATION MANUAL. Zutron Medical, LLC W 98 th St #40-27 Lenexa, KS Phone Fax

Standard Operating Procedure. Air Displacement Pipette Calibration

UNITY 2 TM. Air Server Series 2 Operators Manual. Version 1.0. February 2008

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

OPERATION OF LIQUID PARTICLE COUNTER. GP-B P0045 Rev -

MASSACHUSETTS STATE POLICE CRIME LABORATORY. Certificate of Calibration Procedure for the Alcotest 9510

Arizona State University NanoFab XACTIX ETCHER. Rev A

AKTA pure 25 New Owner s Intro

Standard Operating Procedure

Pipettor. User Manual

NanoSight NS300. NanoSight NS300. Operation instructions. Laser Spectroscopy Labs, UCI

Intelligent Pipette Automation made Simple

SOP for use of the SX19 Stopped-Flow Instrument

VIAFLO 96. Electronic 96 Channel Hand Held Pipettor

Technical Procedure for Instrument Calibration and Maintenance

Technical Procedure for Drug Chemistry Gas Chromatograph/Mass Spectrometry (GC-MS)

AKTA ION EXCHANGE CHROMATOGRAPHY SOP Date: 2/02/05 Author: A DeGiovanni Edited by: C. Huang Reviewed by:

PosiTector UTG, UTG-STD & UTG-ME

ACV-10 Automatic Control Valve

6900 Maintenance Instruction System Flush

Department of Laboratories St. Louis, MO ISSUE DATE: June 2007 REVISION DATE: July 2010 REVIEWED DATE: May 2017 PRINCIPILE:

Tips for Proper Pipette handling and Maintenance. D. Muruganand, Ph.D ILQA - Bangalore, Feb 2014

COULTER A C T diff Analyzer. Operator s Guide. diff. PN DB (March 2016) Beckman Coulter, Inc. 250 S. Kraemer Blvd. Brea, CA U.S.A.

ASE SOLVENT CONTROLLER INSTALLATION INSTRUCTIONS Dionex Corporation

v /07/17 Page 1 of 18

Multiplate Platelet Function Analyzer: An Overview

SomnoSuite FAQ. Setup. Calibration 4. What are the calibration requirements for the SomnoSuite? Settings

METHOD 204F--VOLATILE ORGANIC COMPOUNDS CONTENT IN LIQUID INPUT STREAM (DISTILLATION APPROACH) 1.1 Applicability. This procedure is applicable for

Superconducting Susceptometer (MPMS-5S) Quantum Design Room 296 (MPMS)

CP-8400 AutoSampler and CP-8410 AutoInjector

OXFORD PLASMALAB 80PLUS (CLOEY)

Title: Standard Operating Procedure for Dasibi Model 5008 Gas Dilution Calibrator

STANDARD OPERATING PROCEDURES DIVISION OF COMPARATIVE MEDICINE UNIVERSITY OF SOUTH FLORIDA

Focus on VOC Emissions Reduction Using an Oxygen Based Inerting Control System For Inert Gas Blanketing of Chemical Process Vessels

Varian 3300 Gas Chromatograph Abbreviated Operating Instructions

Laboratory #2 Pipetting Technique and Micropipette Calibration Skills=40 pts

KIOSK: SCORE CENTRE USER MANUAL RCGA Network Kiosk: Score Centre User Manual

Quick Reference Guide

PLASMA ENHANCED CHEMICAL VAPOR DEPOSITION (PECVD) SOP OXFORD PLASMALAB SYSTEM 100

Instruction Manual Dräger MSI P7 and MSI P7 plus

Rapid and Reliable Detection of Dissolved Gases in Water

Air Quality 2b - PFGC/FID Analysis of Benzene and Toluene in Automobile Emissions

Prepared By: Lisa McAvoy 30/Nov/17 dd/mmm/yy. Approved By: Veronica Harris-McAllister 30/Nov/17 dd/mmm/yy

Elcometer 138. Bresle Kit and Patches. Operating Instructions

Calibration Procedure

PRECISION liquid handling

Picus NxT Electronic Pipettes Ergonomic, Efficient, & Safe

Convergent Technologys product overview

Microfluidic Demonstration

Using the Akta Prime plus October 22, 2012

Pipetting Small Volumes

8.1 Calibration of gas sensors

Arizona State University Center for Solid State Electronics Research Issue: E Title: Heat Pulse 610 Operating Procedure Page 1 of 7

Lab Skills Practice: Pipetting Small Volumes. B3 Summer Science Camp at Olympic High School 2016

Draeger Fabius GS Pre-Use Check

Elcometer 138. Bresle Kit and Patches. Operating Instructions

Armfield Distillation Column Operation Guidelines

OPERATING INSTRUCTIONS FOR

MSD 96-Well MULTI-ARRAY CRP Assay

6800 Maintenance Instruction System Flush Procedure

Oil Content Analyzer OCMA-500 Instruction manual CODE:GZ

Usage Policies Notebook for NanoFurnace Furnace (EasyTube 3000 System)

25/04/56. LTC Carmen A. Bell Chief, Laboratory Operations USAMC-AFRIMS

UNCC Biotechnology and Bioinformatics Camp. Dr. Jennifer Weller Summer 2010

Quantos Automated Dosing Solution Preparation Precise concentrations Process compliance Minimize out-of-specs

Title: Standard Operating Procedure for R&R Environmental Devices Model MFC201 Gas Dilution Calibrator

MP-70/50 Series Scoreboard Controller User Guide

Model of a Standard Operating Procedure (SOP) for SO 2 measurements with a UV fluorescence analyzer

SOP-I-101 Operation and Calibration of the Analytical Balance

Calibration Procedure

CHM250 Calibration and Measurement Lab. Balance Calibration

METHOD 25A - DETERMINATION OF TOTAL GASEOUS ORGANIC CONCENTRATION USING A FLAME IONIZATION ANALYZER

JETFIRST 150 RTA SYSTEM OPERATING MANUAL Version: 2 Feb 2012

Oil Content Analyzer OCMA-550 Instruction manual CODE:GZ

Standard Procedure. for using ConfiRM with the SoloVPE. Slope

IMPROVING QUALITY THROUGH INNOVATION: A FULLY AUTOMATED SOLUBLE SALT METER

AKTA 3D SOP. Click on the System Control tab. This screen has 4 windows.

Calibration Procedure

MSD 96-Well MULTI-ARRAY Human (6E10) Abeta 42 Ultra-Sensitive Kit

Relative Humidity Calibration Kit

COULTER A C T diff 2 Analyzer. Operator s Guide. PN BA (August 2010) Beckman Coulter, Inc. 250 S. Kraemer Blvd.

MSD 96-Well MULTI-ARRAY Human (6E10) Abeta 40 Ultra-Sensitive Kit

6890 GC Site Preparation

Fresenius Medical Care North America Service Bulletin

Color Change Procedures ColorMax Powder Booth with Spectrum II Feed Center and Prodigy HDLV Powder Transfer System A04

RayPette Plus Autoclavable Pipette. User Manual

AKTA MC SOP Page 1 9/27/04 AKTA METAL CHELATING SOP

Automated Determination of Dissolved Gases in Water Anne Jurek

QAM-I-117 Volumetric Equipment Calibration Verification

Ensuring pipette & weighing device performance: Verification & Calibration

Transcription:

Liquid Handling Systems 1.0 Purpose - This procedure specifies the required elements for the maintenance and use of the Hamilton- Microlab 1000 Plus and the Microlab 500 Liquid Handling Systems. 2.0 Scope This procedure applies to the Liquid Handling Systems used to prepare liquids for analysis by Headspace Gas Chromatography in the Toxicology Units of the State Crime Laboratory. 3.0 Definitions N/A 4.0 Equipment, Materials and Reagents 4.1 Equipment Hamilton Microlab 1000 Plus or Microlab 500 liquid handling system 4.2 Materials Headspace sample vials Magnetic seals Hand crimper Liquid waste container (suggested 250 ml beaker) Kimwipes or equivalent Reservoir for the diluent solution 4.3 Reagents 10 % bleach solution 5.0 Procedure 5.1 Standards and Controls 5.1.1 The system is verified by the use of positive and negative controls with an internal standard each time the system is utilized. Refer to the Toxicology Unit Headspace Gas Chromatography to Quantitate and Identify Volatiles in Liquids procedure. 5.2 Calibrations 5.2.1 The liquid handling systems shall be calibrated annually by a vendor or contractor and the certificate of calibration maintained by the Blood Alcohol Key Operator. 5.2.2 The calibration shall be recorded in the instrument log by the Blood Alcohol Key Operator or designee. 5.3 Maintenance 5.3.1 The Blood Alcohol Key Operator or designee shall flush the tubing with a 10 % bleach solution, or equivalent, once every three months to remove protein build-up and prevent bacterial growth in the tubing. Page 1 of 7

5.3.2 All maintenance shall be recorded in the instrument log by the Blood Alcohol Key Operator or designee. 5.4 Instrument Set Up - For use with the Toxicology Unit Headspace Gas Chromatography to Quantitate and Identify Volatiles in Liquids procedure. 5.4.1 Hamilton Microlab 1000 Plus 5.4.1.1 Start up 5.4.1.1.1 Turn power on with switch located on the back of the unit at the bottom right. 5.4.1.1.2 Selections on the display screen may be entered by pressing the "ENT/JA/YES" key. 5.4.1.1.3 Different selections may be displayed or highlighted by pressing the "NEIN/NO" key. 5.4.1.1.4 Values may be entered via the numeric keyboard. 5.4.1.2 Program - If program has been entered, skip this step. 5.4.1.2.1 Select the entries which are in bold face type 5.4.1.2.2 Method? - {enter method #} 5.4.1.2.3 *Function: - Dil - Diluter 5.4.1.2.4 *Vol: 5.4.1.2.5 Air gap? - 10 ul 5.4.1.2.6 Asp Automatic Air? yes 5.4.1.2.7 Sample Vol? - 200 ul 5.4.1.2.8 Diluent? ul 5.4.1.2.9 Diluent? - 1800 ul 5.4.1.2.10 Wash Vol? - 0 ul 5.4.1.2.11 Wash Step? 1 5.4.1.2.12 *Syr: 5.4.1.2.13 A - Syringe AD 2.5 ml 5.4.1.2.14 B - Syringe DAD 250 ul 5.4.1.2.15 Standard tubing yes Page 2 of 7

5.4.1.2.16 *Speed: (suggested values) 5.4.1.3 Running the method 5.4.2 Hamilton Microlab 500 5.4.2.1 Start up Asp sample 2 sec. Disp sample 2 sec. Asp diluent 4 sec. Disp diluent 3 sec. 5.4.1.3.1 Select and enter "RUN." 5.4.1.3.2 Choose method containing program. 5.4.1.3.3 Press enter to "zero" the syringes. 5.4.1.3.4 Place the diluent tubing on the left of the Microlab 1000 plus into the diluent solution. 5.4.1.3.5 Prime the system by pressing the "ENT" key at the "PRIME? prompt. The system shall be primed five times before use to clear the tubing of air and any residue. Once priming is done, press the "NO" key to continue. 5.4.2.1.1 Turn power on with switch located on the front of the unit at the bottom right. 5.4.2.1.2 Selections on the display screen may be entered by pressing the "Run/Stop" key. 5.4.2.1.3 The arrow keys may be used to move from one data entry field to another. 5.4.2.1.4 Values may be entered via the numeric keypad. 5.4.2.2 Program - If program has been entered, skip this step 5.4.2.2.1 Select the entries in bold face type: 5.4.2.2.2 Main Menu Create a new Method or Edit an existing Method Select {Select Method Name} Select 5.4.2.2.3 Method Title 5.4.2.2.4 Ratio 1: 9.0 Page 3 of 7

5.4.2.2.5 Dilution 1: 10.0 5.4.2.2.6 Left Diluent Volume (ul): 1800.0 5.4.2.2.7 Right Air gap volume (ul): 10.0 5.4.2.2.8 Right Sample volume (ul): 200.0 5.4.2.2.9 Final Volume (ul): 2000.0 5.4.2.2.10 ACCEPT when complete 5.4.2.2.11 Syringe Fill speed: Left 3 5.4.2.2.12 Syringe Aspirate speed: Right 1 5.4.2.2.13 Syringe dispense speed: Left - 3 Right 2 5.4.2.2.14 Syringe Fill mode: AUTO 5.4.2.2.15 Air gap mode: AUTO 5.4.2.2.16 Air gap delay: 0.0 5.4.2.2.17 ACCEPT when complete 5.4.2.2.18 Wash volume (ul) 0.0 5.4.2.2.19 Left syringe fill speed 4 5.4.2.2.20 Left syringe dispense speed 4 5.4.2.2.21 ACCEPT when complete 5.4.2.2.22 CONFIRM to Save Method, ESCAPE to Cancel 5.4.2.3 Running the Method 5.4.2.3.1 From the main menu, select Run an existing method. 5.4.2.3.2 Highlight the appropriate method and press SELECT. 5.4.2.3.3 Left syringe size (µl): 2500.0 5.4.2.3.4 Right syringe size (µl): 250.0 5.4.2.3.5 CONFIRM 5.4.2.3.6 The system will purge. Page 4 of 7

5.4.2.3.7 Place the left diluent tube in the diluent solution and prime the system. 5.5 Sampling 5.5.1 Refer to the Toxicology Unit Headspace Gas Chromatography to Quantitate and Identify Volatiles in Liquids procedure for sample preparation instructions. 5.5.2 The liquids being analyzed shall be at room temperature before use. 5.5.3 Liquids containing volatile substances shall be covered or sealed to prevent evaporation of the volatiles. 5.5.4 The reservoir containing the diluent (internal standard) solution shall be covered, but not sealed, to prevent a vacuum from forming in the reservoir. 5.6 Application of Procedure on Evidence 5.6.1 Microlab 1000 Plus 5.6.1.1 The following steps may be activated in two ways by pressing the "ENT" key or by pressing the button on the wand. 5.6.1.2 The sample to be analyzed shall be collected by placing the tubing on the right side of the system into the sample, and aspirating the sample by pressing the button on the wand. 5.6.1.3 The outside of the tubing shall be wiped with a clean Kimwipe or equivalent to remove excess sample residue. 5.6.1.4 The sample/diluent shall be dispensed into the proper vial by pressing the button on the wand again. 5.6.1.5 The seal shall be placed on top of the headspace vial and shall be crimped firmly with the hand crimper. The seal shall be checked to ensure that it is secure and cannot be removed by hand. 5.6.1.6 The tubing shall be washed between each sample by aspirating an air sample and then dispensing the air/diluent into a waste container. (The washing procedure flushes the sample tubing with 1.8 ml of diluent). 5.6.1.7 The outside of the tubing shall be wiped again, and the next sample is ready to be collected. 5.6.2 Microlab 500 5.6.2.1 The following steps may be activated in two ways by pressing the run/stop key or by pressing the button on the wand. 5.6.2.2 Allow the left syringe to fill and the air gap on the right syringe to fill. The sample to be analyzed shall be collected by placing the tubing on the right Page 5 of 7

side of the system into the sample, and aspirating the sample by pressing the button on the wand. 5.7 Calculations N/A 5.6.2.3 The outside of the tubing shall be wiped with a clean Kimwipe or equivalent to remove excess sample residue. 5.6.2.4 The sample/diluent shall be dispensed into the proper vial by pressing the button on the wand again. 5.6.2.5 The seal shall be placed on top of the headspace vial and shall be crimped firmly with the hand crimper. The seal shall be checked to ensure that it is secure and cannot be removed by hand. 5.6.2.6 The left syringe shall be allowed to fill and the air gap on the right syringe to shall be allowed to fill before proceeding to the next sample. 5.6.2.7 The tubing shall be washed between each sample by aspirating an air sample and then dispensing the air/diluent into a waste container. (The washing procedure flushes the sample tubing with 1.8 ml of diluent.) 5.6.2.8 The outside of the tubing shall be wiped again and the next sample is ready to be collected 5.8 Uncertainty of Measurement N/A 6.0 Limitations N/A 7.0 Safety 7.1 Refer to Laboratory Safety Manual. 8.0 References Hamilton Microlab 1000 plus User Manual; part number 610 370 / 01. Hamilton User=s Manual Microlab 500 B/C Series; part number 69176 (Rev. B). 9.0 Records Liquid Handling System Instrument log Case Record 10.0 Attachments N/A Page 6 of 7

Revision History Effective Date 09/17/2012 Version Number 1 Reason J-03 conversion to ISO format 02/15/2013 2 2.0 - Reworded for procedure merge with Triad Laboratory 11/15/2013 3 Added issuing authority to header Page 7 of 7