Automated Liquid Handling Station

Similar documents
Liquid Handling Systems

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

AKTA pure 25 New Owner s Intro

Microfluidic Demonstration

UNITY 2 TM. Air Server Series 2 Operators Manual. Version 1.0. February 2008

AKTA ION EXCHANGE CHROMATOGRAPHY SOP Date: 2/02/05 Author: A DeGiovanni Edited by: C. Huang Reviewed by:

AKTA MC SOP Page 1 9/27/04 AKTA METAL CHELATING SOP

Automated Determination of Dissolved Gases in Water Anne Jurek. Abstract: Discussion:

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs.

Read this first. Zetasizer nano series Self installation and Quick start guide MRK825-02

Boyle s Law: Pressure-Volume Relationship in Gases

Armfield Distillation Column Operation Guidelines

Application Note. Rapid performance verification of AZURA systems with refractive index detector. Summary. Introduction

AKTA 3D SOP. Click on the System Control tab. This screen has 4 windows.

Figure 1: Plug in ion inlet of mass spec

SHIMADZU LC-10/20 PUMP

Automated Determination of Dissolved Gases in Water Anne Jurek

VROC (Viscometer/ Rheometer-on-a-Chip) User s Manual 1

Instructions for Assembly, Installation, and Operation of the Gas Addition Kit Accessory with the CEM Discover Systems

Pegas 4000 MF Gas Mixer InstructionManual Columbus Instruments

NanoSight NS300. NanoSight NS300. Operation instructions. Laser Spectroscopy Labs, UCI

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

SOP: Buck Scientific BLC-20P HPLC Operation

VIAFLO 96. Electronic 96 Channel Hand Held Pipettor

DXH Troubleshooting FlowCharts

The ICC Duckworth-Lewis-Stern calculator. DLS Edition 2016

Intelligent Pipette Automation made Simple

Agilent 1100 Series Analytical and Preparative Scale Fraction Collectors. User s Guide

Quick Start Guide. A. Hardware installation B. Software installation C. Start the software for the first time D. Do your first measurement

FROG-4000 TM Chemical Analysis System

Increasing the productivity of ICP-OES with the Thermo Scientific Qtegra ISDS Software

Mass Spec will not Autotune

SS32L Dissolved O 2 Probe

AutoTrace SPE Workstation User s Manual

KEM Scientific, Inc. Instruments for Science from Scientists

In addition to reading this assignment, also read Appendices A and B.

TOC-VCPH/CPN & TOC-Control V Software

Automated Determination of Dissolved Gases in Water By Headspace Calibration of Mixed Gases Anne Jurek

FROG-4000 TM Chemical Analysis System

Using the Akta Prime plus October 22, 2012

Pneumatic high-pressure controller Model CPC7000

Blackwave Dive Table Creator User Guide

MASK INTEGRITY TEST ACCESSORY (MITA) MODEL 8120

SOP for use of the SX19 Stopped-Flow Instrument

CONSUMER MODEL INSTALLATION GUIDE

GA-300 Gas Analyzer. Technical Note. Overview. Front Panel. iworx Systems, Inc. GA-300

Manual for continuous distillation

Appendix D: SOP of INNOVA 1412 Photoacoustic Multi-Gas Monitor. Description and Principle of Operation

FROG-5000TM Chemical Analysis System User s Manual

The instrument will process the samples one by one till all the samples have been cleaned up.

GCMSD-Headspace Analysis SOP

Setting a New Standard in Flash Chromatography Performance

ASE SOLVENT CONTROLLER INSTALLATION INSTRUCTIONS Dionex Corporation

AX5000 Operational Manual

HPICAL Operation & Data Logging Procedures. Click spacebar to advance through slides 1

1. A Tutorial on LSA SwimMeet

Accurate, easy to use and reliable: Easy to use control panel. Clear, backlit LCD display: Quick connect spindles:

Operating instructions for. For visualization of your measurements

Air Displacement Pipetting Module. Total Integrated Liquid Handling

Operating Manual. SUPREMA Calibration. Software for Fire and Gas Warning Units. Order No.: /01. MSAsafety.com

CP-8400 AutoSampler and CP-8410 AutoInjector

Performance Verification of BioTek s Precision 2000 using Artel s Multichannel Volume Verification (MVV ) System

Liquid Handling Application Designer V2.0. Software Manual P/N M5200R0

Quantos Automated Dosing Solution Preparation Precise concentrations Process compliance Minimize out-of-specs

Setting Up the Ingenico isc250 Pinpad via USB

Online League Management lta.tournamentsoftware.com. User Manual. Further support is available online at

Versatility. Accuracy. Compact. Versa. Automated Headspace Vial Sampler

Managing Timecard Exceptions

Varian 3300 Gas Chromatograph Abbreviated Operating Instructions

FinePointe WBP. D a t a S c i e n c e s I n t e r n a t i o n a l TH STREET NW SUITE 100 ST. PAUL, MN USA (651) (800)

Standard Operating Procedure Inductively Coupled Plasma Optical Emission Spectrometer (ICP-OES) - Thermo Scientific icap 6300

Ghost Peaks: How to Fix a Haunting Problem. Jacob A. Rebholz Teledyne Tekmar VOC Product Line Manager

Picus NxT Electronic Pipettes Ergonomic, Efficient, & Safe

Environmental Petrochemical, Pharmaceutical, Foods & Flavors, Chemicals, Personal Care, Forensics,...and more!

Fencing Time Version 4.3

Autosampler problems!

PC Configuration software for Discovery MkVI v 1.03 User guide

Quick Start Guide. For Gold and Silver Editions

Chemistry Lab Cookbook ICP Interstitial Water Analysis v 210.0

XC2 Client/Server Installation & Configuration

SSI Solaris 150 RTA Revision /27/2016 Page 1 of 9. SSI Solaris 150 RTA

Quick Reference Guide

KIV-SACS Safe automatic calibration system:

How to Set Up Your League

Operation of the Perkin Elmer TGA-GC/MS

Description. Measuring Device 3760XBI USP. Balancing

BASIC Z-STACK AND TIME SERIES SCAN ON THE ZEISS LIGHTSHEET Z. 1

5890II GC Standard Operating Procedure 9/2/2005

BVIS Beach Volleyball Information System

Competition Management

ACQUITY UPLC Sample Manager - Fixed Loop Operator s Overview and Maintenance Information

RM-80 respiration monitor

Pneumatic high-pressure controller Model CPC7000

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

Operating Manual. BACVis. Manual BACVis. for. Sensors and MilliGascounter. Rev

Triturus Analyzer Instructions for Use

Laboratory #2 Pipetting Technique and Micropipette Calibration Skills=40 pts

FireHawk M7 Interface Module Software Instructions OPERATION AND INSTRUCTIONS

INSTRUCTIONS FOR NAVIGATING TOPDOG

Hertfordshire Girls Football Partnership League Promoting the development of girl s football in Hertfordshire

Transcription:

Automated Liquid Handling Station Software User s Guide Manual Part Number 32-0442-048 Rev 0 2018 Teledyne Technologies Incorporated. All rights reserved. Printed in USA.

Installation See the SimPrep Quick Installation Guide for information on how to install the hardware and software. See the Teledyne CETAC ASX-280/ASX-560 Operator s Manual for additional information about the autosampler. REMINDER The syringe unit must be connected to the PC with the supplied USB or serial cable. Likewise, the autosampler must be connected to the syringe unit with the supplied serial cable. The USB-RS232 adapter cables are not ordinary USB-RS232 adapters. The software works exclusively with these cables. Vial Positions Place vial racks on the sample tray so that the feet on the rack s underside engage the locating slots on the sample tray's surface. Correctly placed sample vial racks will not move more than ±2millimeters in each direction. The racks are named R1, R2, R3, R4 from left to right. Vials are numbered by columns, beginning with R1-01 in the left rear. (21-vial racks are shown here) 01 08 15 01 08 15 02 09 16 02 09 16 03 10 17 03 10 17 04 11 18 04 11 18 05 12 19 05 12 19 06 13 20 06 13 20 07 14 21 07 14 21 R1 R2 The complete name of each vial results from rack name, hyphen and vial position, for example: R1-01, R2-15 Standards are named Standard 1, Standard 2, and so on, from left to right, unless otherwise specified by the user. 2

Running the Software for the First Time The first time you run the software, you will be asked to do two things: Station Configuration Select the combination of syringe unit and autosampler which you will be using. The following Hamilton Microlab syringe units are implemented: Microlab 500: Models 530/531 Microlab 600: Models 615/625/635 (Fluidic tubing according to ML625-DIL required) The following Teledyne CETAC autosamplers are implemented: ASX-280 ASX-560 You will not be able to proceed beyond the login screen until you select a configuration. Log In Initially only one user, "admin," is created, which does not require a password. Click OK to start the software. 3

At the bottom right corner you can choose the language. NOTE Before creating a new sequence please make all important station, sequence, and user settings (see page 7). Setting Up the Software For a Dilution 1 Configure the operating parameters (see Settings Menu on page 7). The station settings are global and will apply to whatever sequence is loaded, whereas the sequence settings apply only to the loaded sequence. 2 Create a new sequence (see Sequence Table below) or load an existing sequence ( File>Open ). You must be logged in as an admin user to create a new sequence ( File>New ). Remember to save the sequence ( File>Save ) when you are done setting it up. 3 Use the icons on the main screen or the selections in the Station menu to start the sequence. Sequence Table After log in the following window appears: In the sequence table you can create, start, save and load dilution sequences. This means that after creation and saving of a standard dilution sequence this sequence can be loaded and run as often as necessary. Sequence Information Current User: Start Date: Method creator: Method Date: The system fills in the user name as selected during log-in. The system fills in the start time of the sequence. The user who created the sequence. The system fills in the method s last save date. 4

Diluent: Rack 1-4: Enter the name of the current diluent. This does not affect system performance, but is meant as a reminder for the user to ensure that the correct diluent is used. This name must be an exact match to one of the diluent names defined in Settings>Station>Diluent. For each rack position, select the type of rack you will use. For the ASX-280, only two racks are available, so the fields "rack 3" and "rack 4" have to remain empty. For an ASX-560, four rack positions are available. Contact Teledyne CETAC if you need additional rack types. Status By clicking the icon in the Status column, you can change the line status to Skip, Go or Express. The Error, Running and Done icons are set by the software. By clicking the column header you can change the states of all lines. Skip: The line will not be processed (user) Go: The line will be processed (user) Express: The line will be processed preferentially (user) Error: The line has an error (system) Running: The line is in process (system) Done: The line is finished (system) Sample The sample is the vial with the undiluted sample. Position Name Position of the undiluted sample vial. (e.g. R1-01). Name of the sample (optional informative only) 5

Dilution (1-3) The dilution fields let you specify the destination vial and dilution parameters. Up to three dilutions can be done from a single sample (see Sample Splitting on page 16 for an example). Position: Position of the destination vial on the tray (e.g., R2-01). Volume [µl]: The total volume of the dilution in µl Vol Sample: Vol Std: The volume of the undiluted sample. The following notations are allowed: o 100 absolute Volume in µl o 10% percentage o 1:10 relative volume based on the total volume o 1+9 relative volume based on the total volume o 1/10 same as 1:10 The volume [µl] of standard. Use the same notation as for Vol Sample. Name Std: The standard name (e.g., Standard 1) Red dots indicate errors. To see information about the error, hover the cursor over the red dot. 6

Station Menu Start Starts the sequence according to the values given Pause Stop Initialize Pauses the run. Continue by clicking Start. Stops the sequence immediately Sends the syringe and autosampler probe to their home positions Change Syringes Purge Moves the syringe drive down so that the syringe can be removed. After reinstalling, click Initialize. Purges the system with the defined Purge Volume Pump Standard Pumps standard into waste. This function is only used with the MVP motor valve accessory. Settings Menu The Settings menu is available only for users with admin rights. Station Settings The Station Settings are global and will affect the running of all sequences. Only the Diluents and Syringes tabs need addressed by most users. Diluents 7

Please enter the diluent names. You will use these names to specify diluents in the sequence table. Usually there is just one diluent name, but in some cases (e.g. when using a motor valve MVP) it is possible to use different diluents. If you have already entered a diluent name in the sequence table, all that needs to be done in the Diluents tab is to change the entry so that it exactly matches what is seen on the sequence page. This does not affect function. Standards Please enter the standard names. The positions on the sampler are shown in the picture on page 2. In some cases (e.g. when using a motor valve MVP) it is possible to use standards not located in these vials. Syringes This is where the syringe sizes are specified. Ensure that the syringe sizes listed match what is currently installed on the system. Note that S1 is the left syringe and S2 is the right. The smaller syringe must be installed on the right. This arrangement allows for the greatest accuracy in dilutions as the smaller syringe tends to handle sample movement while the larger handles diluent movement. Misc Loop Volume: Purge Volume: The volume of the tubing between needle and valve. This volume is used to block dilutions where sample or standard could reach the syringe. This volume will be purged to waste when clicking Purge. 8

Sequence Settings The settings in this dialog are stored together with the sequence, so they can be different for each individual sequence. Volumes Volumes is the most commonly used tab among of all the settings as it gives access to many useful features of the software. Air Segment: No Drop Air Volume Dip into Washport: Initial Wash Volume The specified volume of air will be pulled into the probe before loading any sample or standard. This creates a separation between standards, samples, and diluent preventing mixing and ensuring cleaner washout and more accurate dilutions. A volume of air can be pulled up after dispense or pickup in order to avoid drips. If this box is checked the probe will visit the rinse station after each aspiration of either standard or sample to prevent cross contamination. At the beginning of each sequence the probe will visit the rinse station and dispense the specified amount of diluent. This is to ensure that the system starts with a clean probe and fresh diluent. If this is set to 0 there will be no initial rinse visit. Wash Volume between samples The specified amount of diluent will be dispensed into the rinse station between each sample. If this is set to 0 the rinse station will not be visited between samples. Mix Volume Some samples may require mixing beyond what will be experienced during the dispense step. For such there is the option to have the probe visit again, pull up the specified amount of sample, and then re-dispense. This can be repeated several times if desired. Mixing is done by repeated aspiration and dispense. The first parameter is the volume which is used during mixing. The second parameter is the number of repetitions. Pay attention to the needle depth, as the needle must dip into the liquid in the vial for mixing to occur. 9

Needle Depths Needle depths can be adjusted individually for each sequence, rack, row, and vial. The depth is measured from the upper, fully retracted needle position. Needle depth can be adjusted between 0mm (fully up) and 150mm (fully down). Pay attention to the depth to prevent the needle from crashing into the bottom of the vial. If there might be a sediment in the vial take care that the needle does not reach this sediment. Sample positions Dilution positions Default Needle Depth 130 mm 80 mm Flows Flows can be adjusted individually for each sequence and each vial. If the table does not contain a flow value for a given position, a standard flow which is suitable for most cases will be used. Therefore flows should only be changed in case of problems like 10

- Outgassing air during aspiration (slow flow) - High viscous samples or diluents (slow flow) - Too much sprinkling during dispense (slow flow) Due to hardware restrictions not every flowrate is possible. If the desired flowrate is not possible the system chooses the next lower possible flowrate. Beside this there are minimum and maximum flowrates for the different syringe sizes: Flow [µl/sec] Microlab 600 Microlab 500 Syringe size min max min max 10µL 0,003 6,5 # # 25µL 0,007 16,5 0,1 12,5 50µL 0,014 33 0,2 25 100µL 0,03 66,5 0,4 50 250µL 0,07 166,5 1 125 500µL 0,14 333 2 250 1000µL 0,3 665 4 500 2500µL 0,7 1250 10 1250 5000µL 1,4 2500 20 2500 10000µL 3 5000 40 5000 25000µL 7 5000 100 12500 50000µL 14 5000 # # Users This dialog is available only for users with admin rights. It allows you to create new users and set admin rights. If a user is marked as is admin he will be shown the Settings menu and the commands New, Save and Save as which are hidden for a normal user. When installed, there is only the user "admin" with no password. By clicking the button new... the following dialog is opened: 11

Enter a user name and an associated password (can be empty). If the user name you entered already exists, the software asks whether the user should be overwritten. This is useful if you want to change a user's password 12

Example Methods Dilution The most common application of the SimPrep is sample dilution. See below for an example of a simple 1:10 dilution. 13

Dispensing Another common use for the SimPrep is as a dispenser. This can be used to add diluent to an existing solution or an empty vial. Note that the Sample Position and Vol Sample are left blank when dispensing rather than diluting. 14

Serial Dilution Occasionally it may be necessary to prepare your samples in a multistep process called serial dilution. Below is a depiction of a three step 1:100000 dilution. The three steps are repeated across 5 samples. 15

Sample Splitting The SimPrep software allows you to prepare the same sample up to three different ways. This works nicely when the same sample needs to be prepared for multiple applications. Here you see the sample being done at a 1:10, a 1:5, and a 1:100 with standard spike. In the sequence it can be seen that while only one sample position is indicated there are three dilution positions. This indicates that the same sample is to be prepared three different ways. The order of these different dilutions is determined by the final concentration of each, with the least concentrated (1:100) being performed first. In this example the order would be Dilution 3, Dilution 1, Dilution 2. 16

Calibration Curve One very useful application of the SimPrep s standard addition option is the creation of calibration curves from a single stock solution. This sequence table shows how the SimPrep can create a 6-point calibration curve: This same preparation can also be shown by percent instead of value: These two sequences produce identical results: a reliable calibration curve made from a single standard stock. Note that there is no sample specified as the only solution being diluted is the standard. The blank is simply dispensed from the probe, which provides a matrix match to the standards in the curve. If desired, this could also be done out of a single sample position rather than the standard positions. 17

Service & Safety Instructions Microlab Syringe Units For safety and service information, see the manuals, which may be found under the Help menu in the SimPrep software. Autosampler For safety and service information, see the Operator s Manual on the CD. Changing Syringes To remove the syringes, go to Station > Change Syringes. Install the new syringes and confirm by clicking OK. Remember that the smaller syringe should always go on the right (S2). Flushing the Liquid Flow Path At regular intervals, the entire liquid flow path should be rinsed with a pure medium. Use the purge function (Station > Purge). Getting Help If you need more assistance please contact Teledyne Cetac Customer Support at cetacservice@teledyne.com. 18