Technical Support Note

Similar documents
White Paper. Chemical Sensor vs NDIR - Overview: NDIR Technology:

Protective Atmospheres, Measurement Technologies and Troubleshooting Tools

Diagnosing EVAP systems By: Bernie Thompson

METHOD 25A - DETERMINATION OF TOTAL GASEOUS ORGANIC CONCENTRATION USING A FLAME IONIZATION ANALYZER

Compiled by: B Beard. Approved by: SH Carstens. Description of requirements and procedures for compact provers to be used as verification standards.

acrolein, acetaldehyde and acetone( cm -1 ); methanol (1306 cm -1 ); ethylene (949 cm -1 ); and isoprene (893 cm -1 ).

CHAPTER 16 %UHDWKLQJ*DV0L[LQJ3URFHGXUHV

METHOD 21 - DETERMINATION OF VOLATILE ORGANIC COMPOUND LEAKS. 1.2 Scope. This method is applicable for the

Problem Solving. Gas Laws

Example: 25 C = ( ) K = 298 K. Pressure Symbol: p Units: force per area 1Pa (Pascal) = 1 N/m 2

Flow meter. bellow vaporizer. APL valve. Scavenging system

The Helium Leak Detector

Membrane covered optical CO 2 sensor

Vehicle and Engine Emissions Testing

Air Quality 2b - PFGC/FID Analysis of Benzene and Toluene in Automobile Emissions

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

Applications Note: Use of "pentane equivalent" calibration gas mixtures

Medical Instruments in the Developing World

ENVIRONMENTAL AND POLLUTANTS GAS ANALYZERS

Multi Cylinder TPA and DI Pulse Model Development using GT-SUITE. Lakshmidhar Reddy Isuzu Technical Center America

Kinetic-Molecular Theory

E A C S. Engine Altitude Conditions Simulator. Technical description

VOC Emissions From the Drying of Red Alder Lumber

Application Note AN-107

Chapter 13 Gases, Vapors, Liquids, and Solids

METHOD 3C - DETERMINATION OF CARBON DIOXIDE, METHANE, NITROGEN, AND OXYGEN FROM STATIONARY SOURCES

J. David Hailey Ph.D. Vice President, Business Development COSA Xentaur 7125 North Loop East Houston, TX 77028

Focus on VOC Emissions Reduction Using an Oxygen Based Inerting Control System For Inert Gas Blanketing of Chemical Process Vessels

Mass Spec will not Autotune

World of Chemistry Notes for Students [Chapter 13, page 1] Chapter 13 Gases

Process Name Compressed Gas Cylinders Program

Pressure Regulator. Instructions for Use

Section 35 Brieser Construction SH&E Manual

Common-duct series-cell electrolyzer with anomalous gas production rate

CUTTING TORCH SAFETY. The Safe Use and Handling of OXY Fuel Cutting, Welding, and Heating Equipment

OxyCheq Expedition-X Oxygen Analyzer. Operator s Manual

Quebec Quebec Tel : Fax : MSDS: Hydrogen 25% in Nitrogen Mixture PRODUCT INFORMATION

Summary of the MRA LPG Codes of Practice

Compressed Gases and Cryogens

MK 3 Passive Operating Guide

Application Worksheet

Exercise 2-2. Second-Order Interacting Processes EXERCISE OBJECTIVE DISCUSSION OUTLINE. The actual setup DISCUSSION

OPERATOR S MANUAL Ar-Gone Weld Gas Analyzer

Title: Standard Operating Procedure for Measurement of Ethylene (C 2 H 4 ) in Ambient Air by Reduced Gas Detection (RGD)

IPG IGNITION GAS PILOTS BACK-LOADED GAS

RADIATION PROCEDURES MANUAL Procedure Cover Sheet

DANGER WARNING IMPORTANT

Lab 3 Introduction to Quantitative Analysis: Pumps and Measurements of Flow

1. Add a new Annex B.8 to read as follows:

M3060 Handling Compressed Gas Cylinders Safely. Leader s Guide

Cal/OSHA T8 CCR 1536 Cal/OSHA T8 CCR 4799 Cal/OSHA T8 CCR 4845 Cal/OSHA T8 CCR 4848

Detector Carrier Gas Comments Detector anode purge or reference gas. Electron Capture Nitrogen Maximum sensitivity Nitrogen Argon/Methane

General Chemistry I Percent Yield of Hydrogen Gas From Magnesium and HCl

I. Subject: Compressed gas cylinders, regulators, and portable liquid systems.

Leakfinder INSTRUCTION MANUAL. Diagnostic Smoke Vapor Machine. Model No. WV605. with UltraTraceUV Dye Solution

OXYGEN ACETYLENE WELDING & CUTTING EQUIPMENT

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs.

Sizing Pulsation Dampeners Is Critical to Effectiveness

Tigerloop Article. 1 of 8 11/22/ :33 AM. Tigerloop Article - As seen in Fuel Oil News Magazine. by Lindy Lindtveit

RD(H)20/25 Pressure-Reducing Regulator User Manual

JLCA NEWS LETTER. No.21. Japan Auto Parts Industries Association

Revision 2013 Vacuum Technology 1-3 day Good Vacuum Practice 1 Day Course Outline

CALCULATING THE SPEED OF SOUND IN NATURAL GAS USING AGA REPORT NO Walnut Lake Rd th Street Houston TX Garner, IA 50438

Chemistry Chapter 11 Test Review

OXY FUEL SYSTEM SET UP & SHUT DOWN PROCEDURE CHECKLIST ACETYLENE FUEL GAS

Instruction Bulletin Addendum For Pressure-Balanced In Situ Oxygen Probes

Chemistry HP Unit 6 Gases. Learning Targets (Your exam at the end of Unit 6 will assess the following:) 6. Gases

Describe Flammable Gas Measurement

Oxygen Dialflow Meter. Instructions for Use

How is pressure handled when we have a mixture of gases?

The Discussion of this exercise covers the following points:

Welding. Module

Cylinder Exchange Training Manual

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

CITY AND COUNTY OF DENVER CR&CF RISK UNIT Compressed Gas Safety Standard

deltaflowc deltaflowc Venturi or Probe

Characterizing a Cu/Mn Alloy for Extracting Oxygen from Inert Gas. Streams

Title: Standard Operating Procedure for Dasibi Model 5008 Gas Dilution Calibrator

Safe Work Instructions For Oxygen Acetylene Equipment

Series MG Mixing Tubes

CHAPTER 31 IDEAL GAS LAWS

Flow metering in gases Introduction to COMBIMASS family

Dalton s Law How is the total pressure of a mixture of gases related to the partial pressures of the component gases?

Foundations of Agriculture

Welding, Cutting, and Brazing

Oxygen Dialflow Meter. Instructions for Use

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

PLANT OPERATIONS AND TECHNOLOGY I & II: REAL TIME FURNACE AIR IN- LEAKAGE MONITORING ON COAL, OIL AND/OR GAS FIRED BOILERS

Technical Data Bulletin #221

Reclaim Basic Set Up

Ontario ENGINEERING STANDARD SPECIFICATION 1.0 PURPOSE

GEN-1e CO2 Generator OVERVIEW INSTALLATION PROPANE GENERATORS ONLY NATURAL GAS GENERATORS ONLY

LOW PRESSURE EFFUSION OF GASES revised by Igor Bolotin 03/05/12

USER MANUAL OPERATION AND THE USE OF A CAR WITH. Diego G3 / NEVO SEQUENTIAL GAS INJECTION SYSTEM

Accelerated Chemistry Study Guide Chapter 13: Gases

Instruction Manual 742 5/1/2009. Eclipse Ratio Regulators ES Series Version 1

INSTRUCTOR RESOURCES

Ch. 14 The Behavior of Gases

Maintenance and Troubleshooting of Pneumatic Conveying Systems for Sand in a Foundry

Safe Handling of Pressurized Gases and Cylinders. Dr. Michael Hanisch

Transcription:

Title: Air Dilution Correction using O2 and CO2 TSN Number: 17 File:S:\Bridge_Analyzers\Customer_Service_Documentation\Technical_Support_Notes\ 17 Air Dilution correction using O2 and CO2.docx Created by: R. Schrader Last Revision Date: 22-Nov-07 Overview Qualify the exhaust by using the O2 and CO2 readings: The purpose of this document is to provide insight into air dilution the major cause of gas measurement errors in tailpipe testing of vehicle exhaust and a methodology to qualify the integrity of the exhaust gas sample being measured. The Problem - Getting good exhaust gas delivery with pulsating exhaust: Internal combustion engines produce exhaust gas pulses which can easily be mixed with air as ambient air gets drawn into the tailpipe. Sometimes it is difficult to obtain good exhaust gas due to low exhaust gas volume and pulsations at low rpm s, insufficient or difficult probe insertion, or an extraneous air leak. Fortunately, the levels of O2 and CO2 in the delivered gas can be used to qualify the integrity of the gas sample and determine the relative amounts of exhaust gas to ambient air in the gas sample. The oxidation of the hydrocarbon fuel produces H2O (water) and CO2 and CO and use up the oxygen in the air to do so. While water vapor is not measured, the carbon products are, as is oxygen allowing a quick and easy way to tell if the gas being measured is air-diluted. Exhaust Gases Principle of Combustion: The purpose of the engine is to use the oxygen in ambient air (about 21%) to oxidize the hydrogen and carbon atoms in the fuel producing heat as a result, and then to use this heat to create mechanical power. To do this, the engine intakes ambient air, mixes it with the correct ratio of fuel, intakes it into the cylinder, ignites it, and uses the heated expanding gas to create power. The air/fuel mix is balanced so that there should be just enough oxygen in the incoming air to burn all of the fuel in the intake charge. This is called Stoichiometric combustion and spark-ignited engines seek to maintain air fuel mixtures close to stoichiometric throughout the range of rpm and power settings. This means that the exhaust gases produced should have very low levels of unused oxygen and high levels of CO2 in them as opposed to ambient air which has high levels of oxygen and low levels of CO2. This can be used to determine if there is ambient air in the measured gas. 1 of 5

How to use the O2 and CO2 Readings to estimate air dilution: Because we know that there is 21% oxygen in ambient air, every extra 1.0% O2 in the exhaust is an indication of 5% air dilution. So, for example, if the analyzer is indicating 4.5% O2, and you are expecting to see 0.5% O2, then you have 4.0% excess Oxygen meaning about 20% air dilution. So always look first at the O2 reading to see if it is low enough. If it is not you have a high probability of air dilution. This air dilution means that all of the other gases will be reading lower than they would be on true exhaust gas too, and you can use this fact to confirm that you are seeing air diluted exhaust and the next thing to do is to add up all the carbons in the exhaust gas. The combined addition of CO and CO2 on gasoline is about 15% for gasoline, and 12% for LPG. Look at the CO and CO2 readings, add them together, and evaluate the sum. For the case above you would see only 80% of the expected 15.0% CO+CO2 in gasoline exhaust or about 12%. For LPG, where the expected carbon sum is 12%, you would be seeing about 10%. The combination of high O2 and low carbon sums are proof of air dilution, and can easily be used to qualify exhaust gas sampling and find air leaks. This method allows you to evaluate and reduce the amount of air dilution in the gas sample by changing the probe insertion length, position, or partially blocking the exhaust - or by increasing the throttle setting to increase the gas flow to fill the exhaust system better. Once you have achieved the best sampling you can, you can compensate for it in the other gas readings. In the case above, for example, dividing CO, HC, CO2 and NOx by 0.8 will correct the readings for the 20% air dilution. Correcting the Sources of Air Dilution what to look for: When the probe is first inserted in the exhaust pipe (engine running), you should expect to see the indicated O2 reading go down from 20.6% to 1.0% or less within about 10 seconds. If the O2 level does not go down low enough but stabilizes at a higher than expected reading, this is an indication that air dilution exists, and the level of air dilution can be determined by multiplying the excess O2 reading (subtract the normal O2 reading from the indicated O2 reading first) by 5% air dilution. A good number to obtain is less than 10% air dilution, or less than 2.0% excess O2 in the gas being measured. If you see more than this, you should troubleshoot the system and correct it if possible. Vehicle-Related Air Dilution: Pulsating Exhaust Gas: Increase the engine rpm to create more exhaust gas volume and smooth the flow, and watch the exhaust gas analyzers. If the O2 reading goes down to acceptable levels after 2 of 5

about 10 seconds or so you are getting air dilution at the probe tip. This can be corrected by either increasing the insertion depth of the exhaust probe, or restricting the area between the probe and the tailpipe to prevent outside air from entering the exhaust pipe. Additionally, the engine speed can be increased to create a better fill of the exhaust pipe. Air Leaks in the Exhaust, or Intentional Air Injection: Examine the exhaust system for air leaks, and make sure Air Injection Control is disabled during the test. Even small air leaks close to the sampling site can cause serious air dilution problems. Analyzer-Related Air Dilution: Correct Ambient Air Leaks in the Probe or Sampling Line: Examine the probe fittings to make sure that they are tightly sealed especially the filter interfaces as sometimes when filters are changed, they either are not tightly installed, or have thread impaction that allows air leaks to occur. The entire gas transport system operates under a vacuum from the probe tip into the analyzer, so any leak in the path can cause unwanted air dilution. Makes sure the gas transport system is leak-free. Water Trap Valve: Examine the water trap valve at the base of the clear water trap. If this valve has particles in it, it cannot seal well and will leak air. This is indicated by bubbles appearing in the water in the water trap, or can be easily tested by temporarily placing your thumb over the water trap valve housing when the probe is installed to ensure a tight seal, and observing its effect on the O2 reading on the analyzer. Backup Test of the Analyzer Check a Modern Car or Truck: Overall System Verification a Functional Test using Standard Automotive Exhaust: Modern (after 1996) gasoline fueled vehicles have advanced engine control systems with electronic closed-loop fuel injection systems and catalytic converters. These vehicles produce excellent examples of complete combustion exhaust gas leaving the tailpipe. They can be used to verify that the exhaust gas analyzer is operating properly, as they produce very low levels of O2, CO, and HC, while keeping CO2 at quite high levels around 15%. The exhaust gas analyzer can be used to measure the exhaust from a gasoline fueled road vehicle as well as LPG-fueled equipment and by knowing that the road vehicle produces very consistent gas levels, both the operation of the gas analyzer and the amount of air dilution in the gas sampling system can be readily assessed. This process can be used as a back-up method to determine whether a problem is due to the gas analyzer or gas sampling method. 3 of 5

Mathematical correction for air dilution: There is a strict mathematical method that uses the O2 reading to determine air dilution, and then the CO2 reading can be used to check the calculated value. This is handy for those cases where there is no easy remedy to correct the source of air dilution. The mathematical process is given below: 1. Record the O2 reading. 2. Subtract the normally expected exhaust gas O2 reading from it (0.5% to 1.0% for non-catalytic converter equipped vehicles.) 3. Divide the remainder by 20.6 the oxygen in ambient air. The result is the air dilution factor the fraction of gas being measured that is ambient air. (This number should be less than 1.00 and as low as possible (0.10 or less) is what you are aiming for.) 4. Subtract the air dilution value obtained above from 1.00. This is the exhaust gas dilution factor, the fraction of gas being measured that is true exhaust gas. (This number will always be less than 1.00, but make it as high as possible.) 5. Divide the reported CO and CO2 readings by the exhaust gas dilution factor obtained above. The result in a dilution corrected sum value, which should agree with the typical values of that exist in the true exhaust. (15.0% for Gasoline and 12.0% for LPG.) 6. If the results of the test calculation confirm the air dilution calculation, you may use the exhaust gas dilution factor obtained in 4. to correct the CO, HC, and NO readings. Divide the CO, HC, and NO readings by the exhaust gas dilution factor to obtain dilution corrected readings. 7. If the results of the test calculation in 5. do not confirm the dilution correction because the corrected CO+CO2 is still too low, you may have estimated too much normal O2 in the exhaust and there may be more dilution than you calculated. Some refinement may be necessary. 4 of 5

The Exhaust Gas Dilution Correction equations look like ExhaustGasDil 1.00 O 2 Re ading ExpectedO 2 AirDilutio n 20.60 ExhaustGasDil 1.00 AirDilutio n O 2 Re ading ExpectedO 2 20.60 CorrectedGas Re adings Gas Re ading ExhaustGasDil 5 of 5