D OPERATION and MAINTENANCE MANUAL MILITARY ALTIMASTER MA-10 (30,000 foot COMPRESSED SCALE: FP-02093) January 3, 2008 REV 12

Similar documents
D OPERATION and MAINTENANCE MANUAL MILITARY ALTIMASTER MA-10 (12,000 foot LINEAR SCALE: FP-02096) April 8, 2013 REV L

DT 630 ALTIMETER, BAROMETER AND COMPASS WATCH OPERATING INSTRUSTIONS

Altimeter and Compass Watch Instruction Manual

ECHO MANUAL WARNING. L B A ltim e te rs. ECHO is a trademark of LB Altimeters, Denmark

MARINER REGATTA YACHTSMAN

BUILT TO WIN PAINTBALL LOADER SPIRE III MANUAL

The Military CYPRES Quick Guide For Operators

ALTIMAX VECTOR X-LANDER

Field 1. Barometer Alarm Symbol. Field 2. Barometer Trend Indicator. Altimeter/Barometer Alarm Symbol Field 4. Altimeter Function Indicator

Bante820 Portable Dissolved Oxygen Meter Instruction Manual

Optical Dissolved Oxygen Meter

TABLE OF CONTENTS INTRODUCTION 3 SAFETY PRECAUTIONS 3 PACKAGE CONTENTS 4 DEVICE OVERVIEW 4 BUTTON OPERATION SUMMARY 5 BASIC OPERATION 6

WARNING! Jump Number Main Window Exit Altitude Alti-Meter Mode Deployment Altitude Speed-Meter Mode...

Bante821 Portable Dissolved Oxygen Meter Instruction Manual

VISO Manual. LARSEN & BRUSGAARD Mosevej Kirke Hyllinge, Denmark Phone: Fax:

DG100 Digital Depth Gauge and Timer. Training Module, Rev B

DOscan10 Pocket Dissolved Oxygen Tester Instruction Manual

COMBAT SWIM BOARD. RJE International, Inc. RJE International January 16, TAC-300 Revision 4

Optical Dissolved Oxygen Meter

RC 195 Receiver-Controller

COMBAT SWIM BOARD. RJE International, Inc. TAC-300 Revision C. RJE International August 3, TAC-300 Revision C

OPERATION MANUAL DIVE CALIPER NOT SCALE / IF IN DOUBT ASK* *ALL UNITS IN MM/DEGREES UNLESS SPECIF. Dive Caliper General DC-051

Model 130M Pneumatic Controller

1.0 General Guide WARNING!

COMBAT SWIM BOARD. RJE International, Inc. RJE International Feb 1, TAC-300 Revision 6

GE Measurement & Control

MicroTim XB. User Manual. Precision Digital Barometric Altimeter / Barometer / VSI. Document Revision 1.0 Firmware Version 3.0

Copyright 2004 by the Thomas G. Faria Corporation, Uncasville CT No part of this publication may by reproduced in any form, in an electronic

TAC-100A DIVER NAVIGATION BOARD OPERATIONS MANUAL. RJE International, Inc. RJE International, October 20, TAC-100A Revision 3

DIVER NAVIGATION BOARD

TABLE OF CONTENTS TABLE OF CONTENTS HOW TO USE THIS MANUAL 3 OPERATING THE WATCH CARE & MAINTENANCE 4 WATCH FUNCTIONS 5-6 KEYS AND THEIR FUNCTIONS 7-8

La Crosse Technology, Ltd. Page 1

WATCH COLLECTION NG701 SERIES INSTRUCTION MANUAL

BAROMETER PRESSURE STANDARD PRESSURE CONTROLLER

NAVY EOD III Low Magnetic Signature DIVE COMPUTER Operator's Manual

Manufactured by: AAA

Kit Details Air Lift Performance HARDWARE LIST STOP!

5 Function Indicator. Outside Air Temperature (C) Outside Air Temperature (F) Pressure Altitude Density Altitude Aircraft Voltage STD TEMP SL 15000

TEL/jlRE" Introduction. Display Features and Modes. Startup Procedure. Power-Up Procedure. Adjustment Modes

User Manual GRI- 1500Li

OPERATING INSTRUCTIONS

DIVER NAVIGATION BOARD. RJE International, Inc. RJE International Feb 1, TAC-100D Revision 10

WELCOME TO THE REVOLUTION

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

Dissolved Oxygen/Temp Waterproof Tester

USER GUIDE 1000, 2000, 2500 & 2500NV, 3000, 3500 & 3500NV, 3500DT.

Aqua-DP. Aqua-DP Waterproof Dissolved Oxygen - ph -mv Temperature Meter. TPS Australia - Quality hand-made instruments since 1968.

INSTRUCTION MANUAL D Pedometer with Clip. VIDEO INSTRUCTIONS:

Heavy Duty Dissolved Oxygen Meter

MANUAL BE SERIES Test Benches

M104 Series: Digital Manometer: 0.1 % of Full Scale

Outbreaker Sailor Compass / Outbreaker Sailor Compass Medium Model: RA202 / RA282 User Manual TABLE OF CONTENTS

DIVER NAVIGATION BOARD

CRYOGENIC TANK SERVICES - CHART RECORDER MANUAL

EN FR DE ES IT NL FI SV ADVIZOR METRON INSTRUCTION MANUAL.

USER S GUIDE DepthTrax 1H HawkEye Portable Depth Finder (DT1H)

Pilot s Operating Handbook

Psyclone TM. Protimeter Thermo-Hygrometer. GE Sensing. Operating Manual. INS7800, Rev. A (September 2007)

Sampling Equipment Catalog. MicroPurge Low-Flow Pump Control

Approach. owner s manual

Bante810 Benchtop Dissolved Oxygen Meter Instruction Manual

PTG100 Precision Test Gauge

OC Panel High Limit Aquastat Kit, Manual Reset p/n

Digital pressure gauge Model CPG500

PART 5 - OPTIONS CONTENTS 5.1 SYSTEM EXPANSION 5-3

F&J SPECIALTY PRODUCTS The nucleus of quality air monitoring programs

OPERATION INSTRUCTIONS

PM105 PRESSURE METER USER S MANUAL

CONGRATULATIONS ON OWNING YOUR NEW NAUTICA WATCH DEVELOPED FROM ADVANCED ELECTRONICS TECHNOLOGY, THE MOVEMENT IS MANUFACTURED FROM THE BEST QUALITY

BI-680 Online Dissolved Oxygen Controller Instruction Manual

User Manual GRX- 1250Li

LM6 LEATHER MOISTURE METER

INCREDIBLY EASY EASILY INCREDIBLE

INSTRUCTION MANUAL. P330A 3D Pedometer LAYOUT FEATURES. VIDEO INSTRUCTIONS:

F11 OPERATING MANUAL F11 OPERATING MANUAL

Outdoor Watch with Sport/Ski-Timer

HumiSys HF High Flow RH Generator

DX2/DXX Operating Instructions

D-OptoLogger Dissolved Oxygen Logger Operation Manual

Instruction Manual VCG-6

QUICK START GUIDE Kestrel 5500 Weather Meter

Manufactured by: Mosevej Kirke Hyllinge, Denmark Phone: Fax:

Date of Purchase

9A5N Solid State CW Paddle

GPS OWNERS MANUAL. All PowaKaddy electric trolleys have been awarded the Quiet Mark by the Noise Abatement Society

GNX 120/130. Owner s Manual

OWNER S MANUAL. All PowaKaddy electric trolleys have been awarded the Quiet Mark by the Noise Abatement Society

CCT-7320/ROC-2313 Reverse Osmosis Controller

For Models: 55A00-2 (HAI UPB 1500W Wall Switch Dimmer) 55A00-3 (HAI UPB 2400W Wall Switch Dimmer) 37A00-1 (HAI Auxiliary Switch)

RH800 & 2000 BASIC OPERATIONS

Instruction Manual DO 6. Economy Hand-held Dissolved Oxygen Meter. 68X Rev 2 Apr 08. Technology Made Easy... Part of Thermo Fisher Scientific

product manual H-1200 & H-1250 Universal and Portable Penetrometers

Contents: 1. Introduction

INCREDIBLY EASY. EASILY INCREDIBLE.

DPC-30 DPC-100. Reference Manual

American Standard. Selectronic Remote Control Operating Manual M965370

35 Watt LED. Lighting System USER MANUAL. January 2019 Rev A

DRILL MONITOR DM-100 OPERATIONS MANUAL

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

HawkEye Handheld Sonar System PX Instruction Manual

Transcription:

D-90046 OPERATION and MAINTENANCE MANUAL MILITARY ALTIMASTER MA-10 (30,000 foot COMPRESSED SCALE: FP-02093) January 3, 2008 REV 12 D-90046 Manual, Operation and Maintenance MA-10 Compressed Rev 12.doc ALTI-2 PROPRIETARY Page 1 of 15

TABLE OF CONTENTS DESCRIPTION... 3 SPECIFICATION... 4 BUTTONS... 5 TURN ON/OFF... 6 POWER SAVING MODE... 7 ZERO TO CURRENT ALTITUDE... 7 MANUAL DZ OFFSET... 8 IMPORTANT... 8 SET DZ ALTITUDE AND BAROMETRIC PRESSURE... 9 BATTERY REPLACEMENT... 11 CLEANING AFTER SALTWATER SUBMERSION... 12 CLEANING AFTER FRESH WATER SUBMERSION... 15 D-90046 Manual, Operation and Maintenance MA-10 Compressed Rev 12.doc ALTI-2 PROPRIETARY Page 2 of 15

1. DESCRIPTION ROBUST stepper motor mechanism 0-40,000' dual scale operation Use in simple "zero" mode for training, or preset DZ altitude and DZ barometric pressure for operational use Easily accessible batteries (Type AA Lithium) Electro-luminescent dial face Robust aluminum frame Waterproof down to 6 feet of water One piece wrist strap, no tools required to change -40 to +80 deg C operation Weight and dimensions are smaller than the original MA2-30 military Altimaster design. The MA-10 is designed for high-altitude (40,000 +) military operation. For training purposes the instrument has a simple zero function. For operational use the DZ altitude and barometric pressure may be preset, the MA-10 will display the correct AGL altitude above the DZ. The unit is based on a stepper motor design and is extremely robust; dropping the instrument will not damage the mechanism. The embedded software is updateable. D-90046 Manual, Operation and Maintenance MA-10 Compressed Rev 12.doc ALTI-2 PROPRIETARY Page 3 of 15

2. SPECIFICATION Model Mechanism Scale Feet per pointer revolution MA10 (FP-02093) ELECTRONIC - solid state pressure sensor with ROBUST stepper motor driven pointer Dual or Linear (programmable to customer requirements) 30,000 (programmable to customer requirements) Max. Operating Altitude 40,000 feet MSL + Ability to preset remote DZ altitude and barometric pressure Case Material Dimensions Weight Yes DZ altitude and pressure may be set at anytime before exit without loss of accuracy. Aluminum 3.27" x 3.20" x 1.37" 83mm x 81mm x 34mm 9.1 oz (255g) (including batteries and wrist strap) Lens Material Lens Replacement Operating Temp Range Dial Face High impact 1/16 thick extruded lexan Supplied with self adhesive lens protector - field replaceable. Lens is factory replaceable. -40 to +80 deg C -40 to +172 deg F Black print on electro-luminescent white face, with yellow warning sector (3000' - 2500') and red warning sector (2500' - 0') LED status indicator Dial face illumination Smart Light Monitor Back-up Illumination Three status modes: On/Off/Sleep Electro-luminescence LED status indicator intensity is adjusted to ambient light level and turns off when backlight is activated. Backlight is automatically turned on in low light conditions when MA-10 is active. Not Required D-90046 Manual, Operation and Maintenance MA-10 Compressed Rev 12.doc ALTI-2 PROPRIETARY Page 4 of 15

Batteries Required 2 x AA Lithium Batteries. (Regular AA batteries may be used but will result in shorter battery life) Battery Life 100 Hrs + Low Battery Warning Automatic power saving mode Automatic Shut-off Tools required to change batteries or wrist strap Battery state indication during self test The system will turn off the motor and backlight if the altitude is below 7000 MSL and there is no significant change in altitude for a period of 30 minutes. The Power On LED at the 12 o clock position will flash to indicate power saving mode. If altitude activity is sensed, the unit will automatically revert to full function. System shuts down after 18 hrs from turn-on, all settings are retained and the system may be turned on at any time without loss of information or accuracy. None Waterproof Depth / Duration 6 feet / 1 hour Metric Available? Yes 3. BUTTONS The MA-10 Altimeter has a total of 5 buttons. The single button marked SEL near the 6 o clock position simply activates the other buttons. This eliminates the possibility of accidental button pushes. D-90046 Manual, Operation and Maintenance MA-10 Compressed Rev 12.doc ALTI-2 PROPRIETARY Page 5 of 15

4. TURN ON/OFF The needle parks at approximately 22,000 when the unit is off. To turn the unit on press and hold the Activate Button marked SEL and then press ON/OFF Button marked I/O. The needle will first show battery status, 7-3 (White) = OK 2.5-3 (Yellow) = Be ready to change battery <2.5 (Red) = Change battery before next jump The needle will move to the current altitude / pressure. The Power On LED at the 12 o clock position will be illuminated. The Power On LED intensity adjusts automatically based on ambient light levels. In very low light conditions the LED is turned off to prevent loss of night vision and the electroluminescent backlight indicates that the unit is active. NOTE: If the needle pauses at 6 o clock position this indicates that DZ Altitude and Pressure have been set. D-90046 Manual, Operation and Maintenance MA-10 Compressed Rev 12.doc ALTI-2 PROPRIETARY Page 6 of 15

5. POWER SAVING MODE The system will turn off the motor and backlight if the altitude is below 7000 MSL and there is no significant change in altitude for a period of 30 minutes. The Power On LED at the 12 o clock position will flash to indicate power saving mode. If altitude activity is sensed, the unit will automatically sweep the pointer one revolution and revert to full function. 6. ZERO TO CURRENT ALTITUDE For training jumps when the Departure Airfield and the target DZ are the same location, zero the altimeter when standing on the DZ. To zero the altimeter, momentarily press the two buttons shown; UP ZERO & the SEL Activate Button. Do NOT hold the UP ZERO button; this will cause the set altitude to increase. NOTE: This action will clear any preset DZ altitude and pressure settings. NOTE: The manual zero altitude will be retained when the unit is turned off. The MA-10 acts like a mechanical altimeter, it will react to barometric changes and will need to be rezeroed when powered back on. D-90046 Manual, Operation and Maintenance MA-10 Compressed Rev 12.doc ALTI-2 PROPRIETARY Page 7 of 15

7. MANUAL DZ OFFSET When the Departure Airfield and the target DZ are at different altitudes, the DZ Offset may be set manually. To manually offset the altitude reading, press and hold the SEL Activate Button and then use the UP ZERO or DWN buttons to set the desired altitude. The rate of pointer movement will speed up (this helps with larger offsets). If you release the UP ZERO or DWN button and continue to hold the bottom button, the rate will start slowly again when you press up or down. NOTE: This action will clear any preset DZ altitude and pressure settings. 8. IMPORTANT When setting altitudes, ignore the compressed scale. There is a barometric pressure graduation dot at every 250 and these may be used to set altitudes below zero feet. The red arrows indicate the position of -1000, -2000, and -3000 feet. D-90046 Manual, Operation and Maintenance MA-10 Compressed Rev 12.doc ALTI-2 PROPRIETARY Page 8 of 15

9. SET DZ ALTITUDE AND BAROMETRIC PRESSURE When the Departure Airfield and target DZ are at different altitudes, the DZ Offset may be entered using the DZ altitude and form of barometric pressure called Altimeter Setting. Step 1 Press the two buttons shown ( PRG & SEL Activate Button), the DZ Altitude set light (DA) will be illuminated. 10. Step 2 Use the UP ZERO or DWN buttons to set the altitude (feet MSL) of the target DZ. NOTE: This action will clear any preset Manual DZ Offset. D-90046 Manual, Operation and Maintenance MA-10 Compressed Rev 12.doc ALTI-2 PROPRIETARY Page 9 of 15

11. Step 3 Press the two buttons shown, ( PRG & SEL Activate Button), the DZ Barometric Pressure set light (DP) will be illuminated. 12. Step 4 Use the UP ZERO or DWN buttons to set the barometric pressure (in Hg.) of the target DZ. Barometric pressure is marked in grey numerals inside the scale. WARNING: WHEN OBTAINING THE BAROMETRIC PRESSURE ALWAYS REQUEST THE ALTIMETER SETTING FOR THE DZ. DO NOT USE THE ACTUAL BAROMETRIC PRESSURE (STATION PRESSURE) OR SEA LEVEL CORRECTED PRESSURE FROM THE DZ. THE CURRENT ALTIMETER SETTING FOR THE DZ IN INCHES OF MERCURY (Hg) WITHIN 100 MILES OF THE INTENDED DZ MUST BE DETERMINED BY USING THE MOST ACCURATE METHODS AVAILABLE. IF THERE ARE NO AVAILABLE MEANS TO CALCULATE THE CURRENT ALTIMETER SETTING, THE COMBAT SETTING OF 29.92 INCHES OF MERCURY WILL BE USED. D-90046 Manual, Operation and Maintenance MA-10 Compressed Rev 12.doc ALTI-2 PROPRIETARY Page 10 of 15

13. Step 5 Press the two buttons shown ( PRG & SEL Activate Button). This completes the DZ setup and the altimeter is in RUN mode. The altimeter displays the DZ Offset between your current altitude and the target DZ. NOTE: Since your altitude is below 8000 AGL from the DZ, the scale is LINEAR, i.e. ignore the compressed scale. NOTE: The DZ altitude and pressure settings will be retained when the unit is turned off. 14. BATTERY REPLACEMENT Step 1 Remove the wrist strap. Locate the battery door lever. Press firmly on battery door to release pressure on latch, and rotate latch 90 degrees past lever lock to unlocked position. D-90046 Manual, Operation and Maintenance MA-10 Compressed Rev 12.doc ALTI-2 PROPRIETARY Page 11 of 15

15. Step 2 Replace batteries with 2 type AA lithium batteries. NOTE: Alkaline batteries may be used, however battery life will be shorter and the unit may not function if soaked to temperatures below -20 deg C. 16. Step 3 Press firmly on battery door and rotate latch 90 degrees past lever lock into locked position. Replace wrist strap. 17. CLEANING AFTER SALTWATER SUBMERSION Equipment needed to clean MA-10 altimeters. Tap, bottled or filtered water. Two (2) clean containers. D-90046 Manual, Operation and Maintenance MA-10 Compressed Rev 12.doc ALTI-2 PROPRIETARY Page 12 of 15

18. Step 1 Fill two adequately sized containers (for the number of altimeters to be rinsed) with tap, bottled or filtered water. 19. Step 2 Remove wrist strap. Open battery compartment and remove batteries. NOTE: Do not reuse these batteries. D-90046 Manual, Operation and Maintenance MA-10 Compressed Rev 12.doc ALTI-2 PROPRIETARY Page 13 of 15

20. Step 3 With the battery door open, completely submerge altimeters in the first container and let soak for 10 minutes. NOTE: Be sure to remove any air pockets from the battery compartment. 21. Step 4 When soak time is completed, dunk the soaked altimeters at least five times in the same container. Shake off excess water by hand. 22. Step 5 Place the drained altimeters into the second container and again dunk at least five times. D-90046 Manual, Operation and Maintenance MA-10 Compressed Rev 12.doc ALTI-2 PROPRIETARY Page 14 of 15

23. Step 6 Place rinsed altimeters right side up with battery door open, on a stable surface to drip dry. 24. CLEANING AFTER FRESH WATER SUBMERSION Follow the procedure for Cleaning After Saltwater Submersion using one rinse container. NOTE: The removed batteries may be reused. D-90046 Manual, Operation and Maintenance MA-10 Compressed Rev 12.doc ALTI-2 PROPRIETARY Page 15 of 15

D-90073 OPERATION and MAINTENANCE MANUAL MILITARY ALTIMASTER MA-10 (12,000 foot LINEAR SCALE: FP-02096) January 3, 2008 REV 9 D-90073 Manual, Operation and Maintenance MA-10 Linear Rev 9.doc ALTI-2 PROPRIETARY Page 1 of 15

TABLE OF CONTENTS DESCRIPTION... 3 SPECIFICATION... 4 BUTTONS... 5 TURN ON/OFF... 6 POWER SAVING MODE... 7 ZERO TO CURRENT ALTITUDE... 7 MANUAL DZ OFFSET... 8 SET DZ ALTITUDE AND BAROMETRIC PRESSURE... 8 BATTERY REPLACEMENT... 11 CLEANING AFTER SALTWATER SUBMERSION... 12 CLEANING AFTER FRESH WATER SUBMERSION... 15 SERVICING... 15 D-90073 Manual, Operation and Maintenance MA-10 Linear Rev 9.doc ALTI-2 PROPRIETARY Page 2 of 15

1. DESCRIPTION ROBUST stepper motor mechanism 0 12,000 scale. 0-40,000' operation. Use in simple "zero" mode for training, or preset DZ altitude and DZ barometric pressure for operational use Easily accessible batteries (Type AA - Lithium) Electro-luminescent dial face Robust aluminum frame Waterproof down to 6 feet of water One piece wrist strap, no tools required to change -40 to +80 deg C operation Weight and dimensions are smaller than the original MA2-30 military Altimaster design The MA-10 is designed for high altitude (40,000'+) military operation. For training purposes the instrument has a simple zero function. For operational use the DZ altitude and barometric pressure may be preset, the MA-10 will display the correct AGL altitude above the DZ. The unit is based on a stepper motor design and is extremely robust; dropping the instrument will not damage the mechanism. The embedded software is updateable. D-90073 Manual, Operation and Maintenance MA-10 Linear Rev 9.doc ALTI-2 PROPRIETARY Page 3 of 15

2. SPECIFICATION Model Mechanism Scale Feet per pointer revolution MA-10 (FP-02096) ELECTRONIC - solid state pressure sensor with ROBUST stepper motor driven pointer Linear 12,000 (programmable to customer requirements) Max. Operating Altitude 40,000 feet MSL + Ability to preset remote DZ altitude and barometric pressure Case Material Dimensions Weight Yes DZ altitude and pressure may be set at anytime before exit without loss of accuracy Aluminum 3.27" x 3.20" x 1.37" 83mm x 81mm x 34mm 9.1 oz (255g) (including batteries and wrist strap) Lens Material Lens Replacement Operating Temp Range Dial Face LED Status Indicator Dial face illumination Smart Light Monitor Back-up Illumination High impact 1/16 thick extruded lexan Supplied with self adhesive lens protector - field replaceable. Lens is factory replaceable. -40 to +80 deg C -40 to +172 deg F Black print on electro-luminescent white face, with red warning sector (2500' - 0'). Three status modes: On/Off/Sleep. Electro-luminescence LED status indicator intensity is adjusted to ambient light level and turns off when backlight is activated. Backlight is automatically turned on in low light conditions when MA-10 is active. Not Required 2 x AA Lithium Batteries. (Regular AA Batteries Required batteries may be used but will result in shorter battery life.) Battery Life 100 Hrs + Low Battery Warning Battery state indication during self test D-90073 Manual, Operation and Maintenance MA-10 Linear Rev 9.doc ALTI-2 PROPRIETARY Page 4 of 15

Automatic power saving mode Automatic Shut-off Tools required to change batteries or wrist strap Waterproof Depth / Duration Metric Available? The system will turn off the motor and backlight if the altitude is below 7000 MSL and there is no significant change in altitude for a period of 30 minutes. The Power On LED at the 12 o clock position will flash to indicate power saving mode. If altitude activity is sensed, the unit will automatically revert to full function. System shuts down after 18 hrs from turnon, all settings are retained and the system may be turned on at any time without loss of information or accuracy. None 6 feet / 1 hour Yes 3. BUTTONS The MA-10 Altimeter has a total of 5 buttons. The single button marked SEL near the 6 o clock position simply activates the other buttons. This eliminates the possibility of accidental button pushes. D-90073 Manual, Operation and Maintenance MA-10 Linear Rev 9.doc ALTI-2 PROPRIETARY Page 5 of 15

4. TURN ON/OFF The needle parks at approximately 10,000 when the unit is off. To turn the unit on press and hold the Activate Button marked SEL and then press ON/OFF Button marked I/O. The needle will first show battery status, 7-3 (White) = OK 2.5-3 (White) = Be ready to change battery. <2.5 (Red) = Change battery before next jump. The needle will move to the current altitude / pressure. The Power On LED at the 12 o clock position will be illuminated. The Power On LED intensity adjusts automatically based on ambient light levels. In very low light conditions the LED is turned off to prevent loss of night vision and the electro-luminescent backlight indicates that the unit is active. NOTE: If the needle pauses at 6 o clock position this indicates that DZ Altitude and Pressure have been set. D-90073 Manual, Operation and Maintenance MA-10 Linear Rev 9.doc ALTI-2 PROPRIETARY Page 6 of 15

5. POWER SAVING MODE The system will turn off the motor and backlight if the altitude is below 7000 MSL and there is no significant change in altitude for a period of 30 minutes. The Power On LED at the 12 o clock position will flash to indicate power saving mode. If altitude activity is sensed, the unit will automatically sweep the pointer one revolution and revert to full function. 6. ZERO TO CURRENT ALTITUDE For training jumps when the Departure Airfield and the target DZ are the same location, zero the altimeter when standing on the DZ. To zero the altimeter, press the two buttons shown; UP ZERO & the SEL Activate Button. Do NOT hold the UP ZERO button; this will cause the set altitude to increase. NOTE: This action will clear any preset DZ altitude and pressure settings. NOTE: The manual zero altitude will be retained when the unit is turned off. The MA-10 acts like a mechanical altimeter, it will react to barometric changes and will need to be rezeroed when powered back on. D-90073 Manual, Operation and Maintenance MA-10 Linear Rev 9.doc ALTI-2 PROPRIETARY Page 7 of 15

7. MANUAL DZ OFFSET When the Departure Airfield and the target DZ are at different altitudes, the DZ Offset may be set manually. To manually offset the altitude reading, press and hold the SEL Activate Button and then use the UP ZERO or DWN buttons to set the desired altitude. The rate of pointer movement will speed up (this helps with larger offsets). If you release the UP ZERO or DWN button and continue to hold the bottom button, the rate will start slowly again when you press up or down. Note: This action will clear any preset DZ altitude and pressure settings. 8. SET DZ ALTITUDE AND BAROMETRIC PRESSURE When the Departure Airfield and target DZ are at different altitudes, the DZ Offset may be entered using the DZ altitude and form of barometric pressure called "Altimeter Setting". Step 1 Press the two buttons shown ( PRG & SEL Activate Button), the DZ Altitude set light (DA) will be illuminated. D-90073 Manual, Operation and Maintenance MA-10 Linear Rev 9.doc ALTI-2 PROPRIETARY Page 8 of 15

9. Step 2 Use the UP ZERO or DWN buttons to set the altitude (feet MSL) of the target DZ. NOTE: This action will clear any preset Manual DZ Offset. 10. Step 3 Press the two buttons shown ( PRG & SEL Activate Button), the DZ Barometric Pressure set light (DP) will be illuminated. D-90073 Manual, Operation and Maintenance MA-10 Linear Rev 9.doc ALTI-2 PROPRIETARY Page 9 of 15

11. Step 4 Use the UP ZERO or DWN buttons to set the barometric pressure (in Hg.) of the target DZ. Barometric pressure is marked in grey numerals inside the scale. WARNING: WHEN OBTAINING THE BAROMETRIC PRESSURE ALWAYS REQUEST THE ALTIMETER SETTING FOR THE DZ. DO NOT USE THE ACTUAL BAROMETRIC PRESSURE (STATION PRESSURE) OR SEA LEVEL CORRECTED PRESSURE FROM THE DZ. THE CURRENT ALTIMETER SETTING FOR THE DZ IN INCHES OF MERCURY (HG) WITHIN 100 MILES OF THE INTENDED DZ MUST BE DETERMINED BY USING THE MOST ACCURATE METHODS AVAILABLE. IF THERE ARE NO AVAILABLE MEANS TO CALCULATE THE CURRENT ALTIMETER SETTING, THE COMBAT SETTING OF 29.92 INCHES OF MERCURY WILL BE USED. 12. Step 5 Press the two buttons shown ( PRG & SEL Activate Button). This completes the DZ setup and the altimeter is in RUN mode. The altimeter displays the DZ Offset between your current altitude and the target DZ. NOTE: The DZ altitude and pressure settings will be retained when the unit is turned off. D-90073 Manual, Operation and Maintenance MA-10 Linear Rev 9.doc ALTI-2 PROPRIETARY Page 10 of 15

13. BATTERY REPLACEMENT Step 1 Remove the wrist strap Locate the battery door lever. Press firmly on battery door to release pressure on latch, and rotate latch 90 degrees past lever lock to unlocked position. 14. Step 2 Replace batteries with 2 type AA lithium batteries. NOTE: Alkaline batteries may be used, however battery life will be shorter and the unit may not function if soaked to temperatures below -20 deg C. D-90073 Manual, Operation and Maintenance MA-10 Linear Rev 9.doc ALTI-2 PROPRIETARY Page 11 of 15

15. Step 3 Press firmly on battery door and rotate latch 90 degrees past lever lock into locked position. Replace wrist strap. 16. CLEANING AFTER SALTWATER SUBMERSION. Equipment needed to clean MA-10 altimeters. Tap, bottled or filtered water. Two (2) clean containers. D-90073 Manual, Operation and Maintenance MA-10 Linear Rev 9.doc ALTI-2 PROPRIETARY Page 12 of 15

17. STEP 1 Fill two adequately sized containers (for the number of altimeters to be rinsed) with tap, bottled or filtered water. 18. STEP 2 Remove wrist strap Open battery compartment and remove batteries. NOTE: Do not reuse these batteries. 19. Step 3 With the battery door open, completely submerge altimeters in the first container and let soak for 10 minutes. NOTE: Be sure to remove any air pockets from the battery compartment. D-90073 Manual, Operation and Maintenance MA-10 Linear Rev 9.doc ALTI-2 PROPRIETARY Page 13 of 15

20. STEP 4 When soak time is completed, dunk the soaked altimeters at least five times in the same container. Shake off excess water by hand. 21. STEP 5 Place the drained altimeters into the second container and again dunk at least five times. 22. STEP 6 Place rinsed altimeters right side up with battery door open, on a stable surface to drip dry. D-90073 Manual, Operation and Maintenance MA-10 Linear Rev 9.doc ALTI-2 PROPRIETARY Page 14 of 15

23. CLEANING AFTER FRESH WATER SUBMERSION Follow the procedure for Cleaning After Saltwater Submersion using one rinse container. NOTE: The removed batteries may be reused. Servicing If the altimeter behaves abnormally or unusually, discontinue use IMMEDIATELY and return to Alti-2, Inc. Alti-2, Inc. 1400 Flightline Blvd. Suite E Deland, FL 32724 Tel: (386) 943 9333 Fax: (386) 943 9303 e-mail: info@alti-2.com Please be sure to include contact information such as Phone Number, Fax Number, and/or email address, and a description of the problem. Status on your altimeter can be checked by contacting the Alti-2, Inc. Service Department, or by initiating a Request for Repair Status through the Alti-2, Inc. web-page. ALTIMASTER is a registered trademark of Alti-2 Incorporated The Altimaster Dial Face design is a registered trademark of Alti-2 Incorporated VELCRO is a registered trademark of Velcro Ind. B.V. CYALUME is a registered trademark of American Cyanmid Company exclusively licensed to Omniglow Corporation. D-90073 Manual, Operation and Maintenance MA-10 Linear Rev 9.doc ALTI-2 PROPRIETARY Page 15 of 15