Installation and Maintenance Manual. Dual Medical Gas Outlets

Similar documents
Installation and Maintenance Manual. Compact Medical Gas Outlets

Product Description 3 Cleaning and Lubricating 4 Inspection and Testing 4

Operation and Maintenance Manual for GENTEC Medical Gas Outlets

Shut-Off Valves and Valve Boxes

COMPACT TRIPLE WALL OUTLET STATION MODEL INSTALLATION AND OPERATING INSTRUCTIONS

Compact Triple Cabinet Outlet Station Model Installation and Operating Instructions

Nitrous Oxide / Oxygen FLOOR MOUNTED OUTLET STATION Installation and Instructions

Compact Triple Cabinet Outlet Station Model B Installation and Operating Instructions

Installation & Maintenance Manual. C2 & C3 Manifolds

Medical Gas Control Panel

Operating and Maintenance Manual. Flowmeter

Installation & Maintenance Manual. Economy Manifold

V-24 OXYGEN LANCE VALVE

GM2 SERIES DOME BIAS AUTOMATIC MANIFOLD

Booster Pump PB4-60 Replacement Kits

Pressure Dump Valve Service Kit for Series 2300 Units

Assembly Drawing: W-311B-A01, or as applicable Parts List: W-311B-A01-1, or as applicable Special Tools: , , &

Installation, Operation and Maintenance Manual for Back Pressure Regulator

Helium-Oxygen Blender

INSTALLATION, OPERATION AND MAINTENANCE GUIDE

PC7-C Flowmeter O2/N2O Sedation Unit Instruction Manual

TRADITIONAL HIGH VIBRATION HOSE SYSTEM THE STANDARD FOR MANY AUTOMOTIVE APPLICATIONS

Table of Contents. Operating Instructions. Resource v.2 Conserving Regulator

Economy Manifold Alert -2. Installation and Maintenance Manual V1.6

MEDICAL REGULATOR RANGE (MEDIREG RANGE)

TECHNICAL DATA CAUTION

Installation Instructions for NP100 Series Nitrogen Control Panels

Oxygen Dialflow Meter. Instructions for Use

INSTALLATION INSTRUCTIONS FOR GRT75-PF-RFS PET FOUNTAIN

Installation Instructions

AREA VALVE SERVICE UNITS

Technical Specification

SERIES-O REGULATOR. Instructions for use

// ADapters GUIDelines

MANUAL GAS MANIFOLDS

Operation and Maintenance Manual for GENTEC Model 881VR Continuous/Intermittent Digital Suction Regulators

Rada-Presto TF2020 and TF2020S

453 Series Steam Heated Vaporizing Regulator

Pressure Dump Valve Service Kit for Series 3000 Units

INSTALLATION INSTRUCTIONS

Horizontal Bladder Tanks

SEQUENTIAL SHOWER VALVE INSTRUCTION MANUAL PLEASE LEAVE THIS MANUAL WITH THE END USER

AND OPERATION INSTRUCTIONS

Model MTB-ASME Horizontal Bladder Tanks

Vertical Bladder Tanks

Instruction Manual. CG16K Barometrically Compensated Capsule Dial Gauge. CG16K Capsule Dial Gauge, 0 to 25 mbar

Yoke Block Instruction Manual

Parker Hannifin Corporation Porter Instrument Division 245 Township Line Road Hatfield, PA USA Tel: Ref Rev.

MOUNTING SURFACE MOUNTING POSITION MAXIUMUM OPERATING PRESSURE FLUID OPERATING VISCOSITY FLUID CLEANLINESS HYSTERESIS REPEATABILITY THRESHOLD VOLTAGE

Auto-Rewind Hose Reels INSTRUCTION MANUAL FOR OXY-LPG MODEL

Technical Datasheet. Rigid & Retractable Pendants. Rigid Pendant

AIR/OVER HYDRAULIC JACK 20 TON

Model 7989T Steel Pipe Squeezer Sch. 40 & Sch. 80. Operations Manual

299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012

Operation Manual Piston Sensed Gas Pressure Regulators

VB-7213 Series. Application. Features. Applicable Literature. 1/2" to 2" Screwed NPT Stem Up Open, Two-Way Valves General Instructions

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

Model MTB-ASME Vertical Bladder Tanks

American Meter Co. Five-Year Limited Warranty Industrial Regulators

Micro Dial-Flowmeter. Instructions for Use

TECHNICAL DATA. Trimpac 244a. September 16, 2013

Contents. Stainless Steel Side Block. 1.1 Separating the Side Block. Stainless Steel Side Block Reassembly of. Assembly from the Helmet Shell

Air-Oxygen Blender. Service Manual. Model No. PM5200 Series PM5300 Series (shown)

CS150 CAP STAPLER OWNER S MANUAL

Model MTB-ASME Vertical Bladder Tanks

Oxygen Dialflow Meter. Instructions for Use

CO2 Tank Conversion Kit P.N , P.N , and P.N

SWIRLFLO Refrigerated fountains with FLEXI-GUARD

Continental Industries TRANSITION FITTINGS or FAX Visit

SAPAG. Safety valves, type 5700 Storage, Use, Operation and Maintenance Instructions. IMPORTANT NOTICE

VB-7323 Series. Application. Features. Applicable Literature. 1/2 to 2 Screwed NPT Three-Way Diverting Valves General Instructions

OWNER S MANUAL SUCTION GUN SG-300

Air Operated Hydraulic Pumping Systems to 50,000 psi

TECHNICAL DATA. Trimpac 251a. Spetember 16, 2013

Specialists in HTM Medical Gas Pipeline Equipment AVSU/Module Operating and Maintenance Instructions

Equinox II USER MANUAL NITROUS OXIDE/ OXYGEN 50%/50% USER ADMINISTRATION SYSTEM 01EQ7000E DEMAND VALVE 01EQ7001E TABLE OF CONTENTS

WHEATLEY Series 500 Swing Check Valve

AUTOMATIC GAS MANIFOLDS

PARTS, SERVICE & REPAIR BULLETIN

Instruction & Parts Manual

Anti-flood device Model B-1

IP2, IP2A and IP2D. Spirax-Monnier International Compressed Air Filter/ Regulators

Instructions for Use. Plug connection for medical gas and vacuum acc. to DIN / 2004 DIN EN ISO

TECHNICAL INSTRUCTIONS

GM Series Dual-Block Multi-Function Gas Control Valves

Wafer Check Valve. Contents. User s Manual. (1) Be sure to read the following description of our product warranty 1

Hydraulic Punch Drivers

MUELLER. Mega-Lite Drilling Machine. Reliable Connections. table of contents PAGE. Equipment 2. Operating Instructions 3-4. Parts Information 5

PRESSURE REDUCING STATION INSTALLATION, OPERATIONS & MAINTENANCE MANUAL

MUD 1. Vent check valves. Instruction and maintenance manual.

EXOTHERMIC TORCH ADAPTER. Instruction Manual

Introduction. Table of Contents. Andersen Medical Gas 12 Place Lafitte Madisonville, LA

Rev. B. Operating Instructions

WHEATLEY WHEATLEY SERIES 500 SWING CHECK VALVE. Installation, Operation and Maintenance Manual

MUELLER. A Wall Type. Indicator Post. Reliable Connections. General Information 2. Technical Data/ Dimensions 3. Installation 4-5.

MUELLER A A Non-Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.

NHR Powder Feed Hopper

BlenderBuddy 2. Operating Manual & Instructions For Use ENGLISH R233M01 REV. A

Wilo Triple Duty Valve / Triple Service Valve Installation and operating instructions

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B

Transcription:

Installation and Maintenance Manual Dual Medical Gas Outlets

Contents Product Description 3 Cleaning and Lubricating 4 Inspection and Testing 4 Installation and Dimensions 5-6 Model Numbers 7 Service 8 Rough-In Assembly 8 Replacement Components 9 Notes 10-11 2 Amico Corporation

Product Description The Amico Dual Medical Gas Outlet combines two Latch Valve Asemblies into a single compact design. The Amico Dual Medical Gas Latch Valve works with standard Amico Rough-in Assembly (which are to be ordered separately). The Rough-in Assembly consists of a brass machined body that incorporates a spring loaded check assembly. A 1/2" [12.7 mm] OD copper pipe is silver brazed into the body for external pipeline connections. The brass body and pipe assembly are inserted into a gas specific plate. The Rough-in Assembly has a color coded label on the copper pipe, so that the installer can easily identify the gas that the copper pipe should be connected to. The rough-in has a check valve that allows the Latch Valve Asembly to be removed for service, without requiring the pipeline to be shut down. The Rough-in Assembly has a gas specific indexing arrangement to prevent the wrong Latch Valve Asembly from being plugged into the Rough-in Assembly. The Dual Latch Valve Asembly is manufactured in 3 different connection combinations using DISS, Ohmeda and Chemetron. The Dual Latch Valve Asembly consists of 2 connectors with an integral check valves, a color coded plate complete with indexing pins and an optional trim plate. CAUTION: DO NOT overtighten the Latch Valve Mounting screws! Distortion of the Latch Valve can occur. The quick connect connectors are compatible with the Ohmeda Diamond and Chemetron adaptors and only corresponding type of adaptors can be used. The DISS connector conforms to the CGA Pamphlet V-5 standards. Since the Rough-in Assembly is the same, the Dual outlets can easily be converted from one connection combination to another by simply replacing the Latch Valve Asembly. NOTE: The Amico Dual Outlet is recommended to be used with 3/8 (10 mm) ID (nominal) rough-ins. For ceiling applications, only DISS connections are recommended. Dual outlet fronts are not servicable. If found to be inoperable, Latch Valve needs to be replaced. www.amico.com 3

Cleaning and Lubricating The Amico Outlets are factory cleaned for oxygen service. Exposed surfaces of the outlet may be cleaned with a mild detergent solution or wiped with a disinfectant commonly used in patient rooms, that is compatible with plastics. Lubricate elastomer seals sparingly with a silicone lubricant that is oxygen compatible. DO NOT USE OIL. Inspection and Testing Medical Gas Outlets should be inspected periodically or at least once a year. The tests should be in accordance with NFPA 99 Gas and Vacuum systems and/or ISO 9170 Terminal Units for Medical Gas Pipeline Systems. Test for Leaks: Ensure that no leaks exists, with or without the adapter inserted. Test for Indexing: Only a mating gas specific adapter should insert smoothly into the outlet, latch and be retained. Test for Flow: Refer to appropriate standards for the proper way of performing the flow test. Note: The Amico Medical Gas Outlets meet and exceed the requirements at the time of manufacture. However, piping source capacity, sizing and restrictions may prevent outlets from attaining these values. 4 Amico Corporation

Installation and Dimensions Dual Wall Outlets DISS, Ohmeda and Chemetron compatible. 1/2 [12.7] O.D. (3/8 [10] nominal) Type K copper pipe rotates 360 for entry from any angle Inch [mm] 11-1/4 [286] 5-3/4 [146] 5-1/2 [140] 1-7/8 [47] Wall thickness may vary from 3/8 to 1 [10 to 25] 4 [102] 8 [203] 6 [152] Dual Ceiling Outlets DISS, Ohmeda and Chemetron compatible. Inch [mm] 5-3/4 [146] 5-1/2 [140] 2 [51] Wall thickness may vary from 3/8 to 1 [10 to 25] 1/2 [12.7] O.D. (3/8 [10] nominal) Type K copper pipe 4 [102] 8 [203] 6 [152] www.amico.com 5

Installation and Dimensions Dual Console Outlets DISS, Ohmeda and Chemetron compatible. Inch [mm] 1/2 [12.7] O.D. (3/8 [10] nominal) Type K copper pipe rotates 360 for entry from any angle 3-3/4 [95] 2-7/16 [62] 2-5/8 [66] 8 [203] 6 [152] Dual Ceiling Column Outlets DISS, Ohmeda and Chemetron compatible. Inch [mm] 3-3/4 [95] 1/2 [12.7] O.D. (3/8 [10] nominal) Type K copper pipe 2-1/2 [62] 2-5/8 [67] 8 [203] 6 [152] 6 Amico Corporation

Model Numbers Dual Outlets The Letter X Defines the Left Side Connection Options: The Letter Y Defines the Right Side Connection Options: DISS = D DISS = D Ohmeda = Q Ohmeda = Q Chemetron = C Chemetron = C 15 LPM Thorpe Flowmeter = T15 15 LPM Thorpe Flowmeter = T15 Outlet O-DZZZ-XY-L-GAS The Word GAS Defines the Type of Gas: The Letters ZZZ Define the Index Type: Amico Double Pin Indexing = FAC Amico Single Pin Indexing = FPC Dual The Letter L Defines the Language: English (NFPA) English (ISO) = U = E Oxygen Medical Air = OXY = AIR French (ISO) = F The Letters XXXX Defines the Rough-In Type: Spanish (NFPA) = SU Spanish (ISO) = SE Wall = W Console Ceiling Column Ceiling = CON = CCOL = CEI O-BAKXXXX-L-GAS (Rough-in Assembly) O-TRIM-M400C (Wall Trim Plate - Chrome) O-TRIM-P275C-G2 (Console Trim Plate) NOTES: Dual outlets are available for Oxygen and Medical Air only. Rough-ins and trims are to be ordered seperately. www.amico.com 7

Service NOTE: Dual outlet fronts are not servicable. If found to be inoperable, Latch Valve needs to be replaced. Rough-In Assembly CAUTION: Ensure that the supply pressure is shut off before performing service. Inside the Rough-in Assembly is a secondary check valve whose function is to shut off gas flow when the Latch Valve Asembly is removed. This seat/seal also prevents leakage around the Latch Valve connector. As the secondary seal is only a static seal, it will rarely need replacement. However, if the seat/seal does need replacement, follow the following procedure: 1. Ensure that no pressure exists in the line by depressing the secondary check valve (5). 2. Remove the retaining ring (8) from the inside of the outlet body. Use a small screwdriver to pull the end of the ring towards the center and then pull the ring up and out. 3. Remove the washer (7), seat/seal (6), secondary check valve (5) and secondary check valve spring (4). Inspect items for wear or damage and replace the seat/seal (6). 4. Re-install the spring (4), secondary check valve (5), seat/seal (6) and the washer (7). Insert the retaining ring (8) into the slot and ensure that the whole ring is seated properly. 5. Turn on the pressure and check for leaks. Re-install the Latch Valve Asembly and perform the inspection and test on page 1. 8 Amico Corporation

Replacement Components Rough-in Assembly Replacement Components Item Description 1 Rough-in Assembly 2 Rough-in Pipe 3 Ganging Screws (2 Required) 4 Secondary Check Valve Spring* 5 Secondary Check Valve * 6 Seat/Seal* 7 Washer* 8 Retaining Ring* Above parts with * are found in repair kit O-RK-BAK, not sold separately www.amico.com 9

Notes 10 Amico Corporation

Notes www.amico.com 11

www.amico.com Amico Corporation 85 Fulton Way, Richmond Hill, ON L4B 2N4, Canada 71 East Industry Court, Deer Park, NY 11729, USA Toll Free Tel: 1.877.462.6426 Tel: 905.764.0800 Fax: 905.764.0862 Email: info@amico.com www.amico.com C US LISTED APE-IM-DUAL-OUTLETS 04.23.2018