OPERATION MANUAL PNEUMATIC VALVES

Similar documents
VS18/26 with PROFINET and EtherNet/IP Interface. ATEX Installation Instructions

Type 0404 / /2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation

Type Operating Instructions. 2/2-way solenoid valve 2/2-Wege Magnetventil Electrovanne 2/2 voies.

4/2 way Pneumatic Solenoid Valve

Operation Manual Air Saver Unit ASV5000 Series

Type 2000 INOX. Quickstart. English Deutsch Français. 2/2-way angle seat valve 2/2-Wege Schrägsitzventil Vanne à siège incliné 2/2 voies

USER MANUAL. JET TST and JET TST S.

Hafner-Pneumatik presents: General information on ATEX 95 & Products for explosion hazardous environment from the Hafner range

Pneumatic switch module 3/2-way valve (On/Off) Types P Types FP Function tested for use of the float in Ex-zone 0

6301 TYPE CAST IRON SAFETY VALVES

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar

INSTRUCTION MANUAL IS3.003

VA FLOWMETERS Supplementary Instructions

Flow controller Type ED/CCB311 Instruction manual

User guide DIAPHRAGM SEALS. Industrial instrumentation for Pressure and Temperature

Pneumatic proportional controller Types M Types FM Function tested for use of the float in Ex-zone 0

Operating and maintenance manual Filter and reducing station Series / 1.0

SOLENOID VALVES AND PNEUMATIC VALVES

Operating Instructions

Type BBS-03, BBS-05, BBS-06, BBS-25

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

PNEUMATIC STOPPERS OPERATING MANUAL. Type F G H - FOG

CAST IRON SAFETY VALVE TYPE 6301

(Certification N:o VTT 08 ATEX 066 or IECEx VTT )

PRAHER PLC-MP AQUASTAR MANAUL 2009

II 2G EEx ia IIC T6. Ignition protection class

MODEL 200 KNIFE GATE VALVES INSTALLATION & MAINTENANCE MANUAL

FLANGED TWO-PIECE BALL VALVES

OFFICINE OROBICHE S.p.A. 1/9

Target disk flowmeter Series DP. Instructions manual DP65 DP500. R-MI-DP Rev.: 4 English version

Installation & Operation Manual Proven Quality since 1892

Safety Please read and keep in a safe place Operating instructions Linear flow control VFC Linear flow control with actuator IFC

Overspeed governors (113 OG Моment 250 MR, 114 OG Moment 250 A3, 115 OG Moment 250 MRL, 119 OG Moment 250 MRL/1)

FLANGED TWO-PIECE BALL VALVES

Spilt body Flange ball valve. TC-205MFF-PN1640 User Manual English Version. Document No: TC-205MFF-PN1640.Ur-manual. Date: 2007/04/2617. Version: 1.

Temperature gauge Installation Guide

To use the Atex valve model is obligatory to consult the appropriate manual.

e.do Gripper Safety requirements, technical features and assembly and integration instructions

Supplementary Installation and Operating Instructions. Variable Area Flow Meters SGK-1 Ex SGK-2 Ex SGK-3 Ex. Category: II 2G Ex IIC II 3G Ex IIC

USER MANUAL PNEUMATIC SERIES SL 275 SL 475 SL(-2) 10 GX 14 GX(-2) 20 DX(-2) 34 GX(-2) 40 DX 46 GX DX 110 DX

453 Series Steam Heated Vaporizing Regulator

Pneumatic valve islands

Push-In Fitting Type Silencer

CS / SE QUICK EXHAUST INSTRUCTION MANUAL 2091

FULL STAINLESS STEEL EXPLOSION-PROOF SOLUTIONS OIL & GAS I OFFSHORE AND ONSHORE

English. Introduction. Safety Instructions. All Products. Inspection and Maintenance Schedules. Parts Ordering. Specifications WARNING WARNING

OPERATION MANUAL NTF-15

FLANGED MULTI-PORT BALL VALVES

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

Directional spool valves, direct operated, with manual actuation

OPERATION MANUAL NTF-60 Plus

Series CGZT three-jaw grippers with T-guide

Type 2080 FALTENBALGVENTIL BELLOWS VALVE VANNE A SOUFFLET. Operating Instructions. Bedienungsanleitung Manuel d utilisation

OPERATING INSTRUCTIONS MANUAL FOR QACV PNEUMATIC DOSING PUMP

Pressure switch, Differential pressure switch and Thermostat RT-E

Air operated valve. VGA342R Series

Application Note. Safety Sub-functions SSC Category 1, up to PL c PUS Category 1, up to PL c. Application Note SSC, PUS, Category 1, up to PL c STOP

BETTIS RPE Series Rack and Pinion Pneumatic Actuators. Safety Guide DOC.SG.BRPE.EN Rev. 1 November 2015

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

AIR INLINE METAL SHEAR

Electropneumatic Positioner Type 4763 Pneumatic Positioner Type 4765

ATEX installation and service instruction

Application Note. Safety Sub-function PUS Category 1, up to PL c. Application Note PUS, Category 1, up to PL c M20 S22 R20 M1 Q20

DK46 - DK800 Supplementary instructions

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

30T A/Manual Hydraulic Shop Press

Propane Conversion Kit Instructions

Instruction manual. for. high purity gas pigtails 200 bar / 300 bar

INSTRUCTIONS AND MAINTENANCE MANUAL SERIES: RT

VALFONTA INSTRUCTIONS: OPERATION AND INSTALLATION PRESSURE REDUCING VALVE MODEL PRV44

INSTALLATION MANUAL Matheson Tri-Gas Cabinet Enclosures

Instructions for High Altitude Conversion

Further technical information is available on

Type /2-Way Globe Valve 3/2-Wege-Geradsitzventil Vanne à siège droit 3/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation

* * Data Sheet and Operating Manual. Digital manometer ME01 ## # 87 # HL S#### Dust explosion protection Zone 22.

OPERATING MANUAL. Contents. Bottom outlet ball valve Type ecoline

VALVES ISO 5599/1, SERIES IPV-ISV

SSFU SUPER SPRAYFAST UNIVERSAL ADHESIVE APPLICATOR

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 09.14

3:1 High Ratio Oil Pump W. Extn. Kit

Pressure Regulator. Instructions for Use

OWNER S TECHNICAL MANUAL

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

Safety Please read and keep in a safe place Operating instructions Linear flow control VFC Linear flow control with actuator IFC

Code AWC20HP Air Compressor

Pressure booster combination DPA-CRVZS. Operating instructions a [ ]

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

THE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv)

INSTALLATION, OPERATION AND MAINTENANCE MANUAL. Model Sanitary Vent SECTION I

Operating Instructions

Technical Data. General specifications. Rated operating distance s n 5 mm

INSTRUCTIONS PARTS LIST

Booster Regulator/Air Tank

Magnetic level switch type MR783 Instruction Manual

U S E R M A N U A L AIR FLOWMETER. MODELS: 1MFA2001 (shown) 1MFA9001 CAUTION. ISO Certified

Pilot Check Valve: Metal Body Type

Pressure control, differental pressure control and thermostat Type RT

EP500 Advanced ATEX Electropneumatic Positioner

MECAIR CSN RAINTIGHT ENCLOSURE CLEAN AIR SOLUTIONS PRODUCT LEAFLET

Transcription:

OPERATION MANUAL PNEUMATIC VALVES DIRECTIVE 2014/34/EU ATEX ENGLISH

Index 1 Product identification 2 Security 3 Guarantee 4 Transportation 5 Assemblage 6 Setting up 7 Adjustments 8 Technical information 9 Usage 10 Maintenance 11 Disassembling/Disposal 12 Conformity declaration Rev.0 dated 03-03-2006 Page 2 of 7

1 Product identification This manual describes function and maintenance of the valve and gives important information for a safe usage of it. Product identification: standard model size G1/8" - G1/4" - G1/2" model size 16 mm model size 18 mm model complying with VDMA 24563, size 01 and 02 NAMUR model model complying with UNI ISO 5599/1, size 1, 2, 3 All the persons in charge for the setting up of the valve commit themselves to observe the fundamental instructions about safety against explosions, work safety, accident prevention and to read all considerations indicated in this manual especially in chapter Security. AZ Pneumatica s.r.l. prohibits to reproduce, to distribute, re-use or give this manual to others, both partially and completely. Label with mark ATEX: I II2G Ex h IIC T6 Gb II2D Ex h IIIC T85 Db Ambient temperature: -25 C 60 C European directive approved for potentially explosive atmospheres II2G / II2D Ex h IIC IIIC c T6 T85 C Gb / Gd -25 C 60 C group II, G gas, D dust Protection mode not electric Group gas IIC (it covers IIB, IIA) Conductive combustible dust group Protection class Temperature class Temperature class for dust EPL Ambient temperature range 2 Security All the persons in charge for the setting up of the valve commit themselves to use the valve in a proper way, that is to observe the technical information indicated on the label with mark ATEX and on the Conformity Declaration. Rev.0 dated 03-03-2006 Page 3 of 7

Proper use The valve has been produced to deviate and/or block the compressed air flow on the basis of the technical information indicated in this document. The external pilot occurs in a mechanical, pneumatical, or electropneumatical way. The proper use also includes the duty to let exclusively the producer s special trained workers, intended for the assistance, to carry out any intervention on the valve. It is forbidden for all persons in charge for the setting up of the valve to: do any kind of alteration on the valve; do anything that compromises the safety of the valve; disassemble and/or put out of order any safety and protection device; use fittings and accessories not authorized by the producer. It is compulsory for all the staff in charge for the setting up of the valve to: observe all the safety information indicated on the valve and tags for compressed air connections; maintain these tags readable; use tools in a correct way without getting collisions; observe the producer s information regarding lubrication, solvent and cleaning substances; observe the information regarding safety instructions and security procedures recognized by the EU and the specific ones in the own nation. There could be damages and danger for things and persons if the valve is used in an improper way. The producer declines all responsibility for damages due to an improper use. 3 Guarantee AZ Pneumatica s.r.l. guarantees the conformity of the supplied products, it means that they correspond in quality, quantity and performance to what has been established in the sales contract. The guarantee is valid for 12 (twelve) months and it starts from the delivery of the products and, for the substituted products or parts, from the day of their substitution. Within that date AZ Pneumatica s.r.l., to which the customer, not later than eight days from the delivery for obvious defects and eight days from the date of discovery for the hidden ones, has to send a written report about the defect, commits itself, at its choice, to repair or replace free of charge the parts or products that are defective. The return of defected goods has to be authorized by AZ Pneumatica s.r.l. and must respect the original packing. The guarantee expires if the product has been stored, assembled or used in an incorrect way or if it has received an insufficient maintenance or if it has been modified or repaired without AZ Pneumatica s.r.l. written authorization. AZ Pneumatica s.r.l. is not responsible for defects due to normal wear and tear of these parts that, due to their nature, are subject to quick and continuous wear and tear. 4 Transportation Improper transportation can cause damages and danger to persons and things. The transportation of the valve can be done only by instructed and trained staff. We recommend to store the valve in flat and dry rooms, not subject to dust and vibrations. The damages due to transportation and/or missing parts must be communicated as soon as possible to the forwarder and to AZ Pneumatica s.r.l. or to the re-seller with a written report. Rev.0 dated 03-03-2006 Page 4 of 7

5 Assemblage Wrong assemblage can cause damages and danger to persons and things. We recommend to assemble the valve paying attention to convoy the exhaust air; or in alternative assemble the valve putting silencers into exhaust ports. This is to avoid that inflammable dust can enter the internal space of the valve. Moreover, all the staff entrusted to the assemblage has to be sure that: The package is removed in all its parts and correctly disposed; Pipes and surfaces are cleaned; All the sealing gaskets have been inserted in the valve or correctly put on the connection plate; The valve has to be assembled without efforts and distortions; All the elements of control and connection have to be reachable; Electric grounding through the machine or system has to be done; A technician trained to do the setting up of electrical systems in spaces in which there is the risk of explosions has to connect the electrical supply; The ATEX label has to be readable. To avoid the risk of overheat due to external sources make sure that fresh air always circulate in the valve and that, in proximity of external heat sources, screens against overheating have been assembled. After the assemblage of the valve do not carry out operations of welding on the machine or on the system as the system could leak. 6 Setting up Before setting up verify that all connections has been carried out correctly and that the valve has been assembled and fixed in a correct way. 7 Adjustments The valves and the microvalves in these instructions do not need any adjustments. Rev.0 dated 03-03-2006 Page 5 of 7

8 Technical information The following characteristics are valid for standard size G1/8" and G1/4, series 16 mm, series 18 mm, series VDMA 24563, series NAMUR, series UNI ISO 5599/1 size 1 Fluid Working pressure Working pressure (for servo-piloted valves) Monostable Bistable Filtered air 5 µm without lubrication -0,1 1 MPa 0,3 1 MPa 0,2 1 MPa Temperature [ C] -25 +60 Working frequency 2 Hz The following characteristics are valid for standard size G1/2", series UNI ISO 5599/1 size 2 and 3. Fluid Working pressure Working pressure (for servo-piloted valves) Monostable Bistable Filtered air 5 µm without lubrication -0,1 1 MPa 0,3 1 MPa 0,2 1 MPa Temperature [ C] -25 +60 Working frequency 1 Hz 9 Use There is danger for explosions if the valve is overheated. In case of problems on the valve, stop the machine/system immediately; inform the producer s staff intended for assistance. Do not carry out any intervention on the valve but apply only to the producer s staff. 10 Maintenance The only interventions of maintenance that the customer can carry out are the following: Check the general condition / integrity of the valve. Check the connections. Cleaning of the external surface exclusively with an antistatic damp; no flammable material should settle on the surface of the valve, and the cleaning interval has to be adequate to the ambient condition in which the valve is assembled. in case of electrical valves, only the use of ATEX certificated magnetic coils with the correct electrical characteristics is allowed. The magnetic coils has to be tightened with the nut and the round piece that are given as accessories; verify that the magnetic coil after the assemblage is safely fixed. Rev.0 dated 03-03-2006 Page 6 of 7

N.B. If there are the first occurrences of oxidation at the point of contact between the valve actuation button and the metal lever, the metal lever must be immediately removed. 11 Disassembling / disposal Carry out the disassembling exclusively with: The machine turned off, The compressed air blocked, Unload the compressed air circuit around the valve to reach atmospheric pressure. During the disassembling wear protective glasses and gloves to avoid possible injuries and proceed with particular caution. Observe chapter Security and the local security arrangements. For the disposal of the material strictly follow the local laws and instructions. AZ Pneumatica s.r.l. has the right to modify these instructions and the technical information indicated in this manual. More information: http://www.azpneumatica.srl/azweb/ita/atex.htm Rev.0 dated 03-03-2006 Page 7 of 7