A New GC/MS System Designed for Helium Carrier Gas Conservation

Similar documents
Addressing the World Shortage of Helium

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs.

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

Retention Time Locking: Concepts and Applications. Application

Advancements in Gas Chromatography Analyzers - Keeping up with New Technology. Chuck Runkle Gas Phase Product Specialist ASTS June 2013

Converting Helium Carrier Gas GC Methods Nitrogen and Hydrogen

Zebron Gas Management

UNITY 2 TM. Air Server Series 2 Operators Manual. Version 1.0. February 2008

Best Practice for Identifying Leaks in GC and GC/MS Systems

DETERMINATION OF TETRAHYDROTHIOPHENE IN AMBIENT AIR BY GAS CHROMATOGRAPHY WITH A PFPD DETECTOR COUPLED TO A PRECONCENTRATION TECHNOLOGY

3 Flow and Pressure Control

Operation of the Perkin Elmer TGA-GC/MS

Impact of Air Leaks on the Productivity of GC and GC/MS Systems

Detector Carrier Gas Comments Detector anode purge or reference gas. Electron Capture Nitrogen Maximum sensitivity Nitrogen Argon/Methane

Agilent 7697A Headspace Sampler

Simplified Backflush Using Agilent 6890 GC Post Run Command Application Note

Gases&Technology. Measurement of Impurities in Helium Using the Dielectric Barrier Discharge Helium Ionization Detector. FEATURE.

6890 GC Site Preparation

6890 GC Not Ready Messages (A16010)

GCMSD-Headspace Analysis SOP

Automated Determination of Dissolved Gases in Water Anne Jurek. Abstract: Discussion:

Your local gas generation partner. Precision series Modular gas generation solution for GC.

ASTM WK Standard Test Method for Dissolved Gases. Anne Jurek Applications Chemist

5890II GC Standard Operating Procedure 9/2/2005

Supporting Information for Micro-Collection of. Gases in a Capillary Tube: Preservation of Spatial

Carrier Gases in Capillary GC

Advances in Capillary Column Backflushing

Using the PreVent System in Time-Saver Mode with the AutoSystem XL Gas Chromatograph and the TurboMass Mass Spectrometer

General Specifications: Forensic. Petrochemical Environmental. Lab Quality Analyses in the Field, It Goes with you Anywhere!

Rapid and Reliable Detection of Dissolved Gases in Water

Site Preparation Specification for GCMS system. Dimensions and Weight. Agilent 7820MSD Series G3175A (G7020A), G3176A (G7021A)

Varian 3300 Gas Chromatograph Abbreviated Operating Instructions

HiQ laboratory gas generators.

IMPACT OF THE HELIUM SHORTAGE ON PROCESS GAS CHROMATOGRAPHS

Optimizing Vial Pressurization Parameters for the Analysis of <USP 467> Residual Solvents Using the 7697A Headspace Sampler

During today's webinar we're going to look at the following topics:

Gas Clean. Filters. Delivering Clean Gases for GC and GC/MS Operation

OMCL Network of the Council of Europe QUALITY ASSURANCE DOCUMENT

Title: Standard Operating Procedure for Measurement of Ethylene (C 2 H 4 ) in Ambient Air by Reduced Gas Detection (RGD)

Considerations and Best Practices for Maintaining Your Agilent GC s Split/Splitless Injection Port

Automated Determination of Dissolved Gases in Water Anne Jurek

For additional information about our solutions, please visit our web site at US/Pages/HomePage.

The. «Modular Alliance» Gas Generators. ALLIANCE, the partnership that keeps the gas flowing. One step ahead!

Agilent G3180B Two-Way Splitter Kit

Your local gas generation partner. Precision series Modular gas generation solution for GC.

User manual. TC-20 Sample conditioning and dry-purge rig. QUI-0003 Version 6.3 September

High Automation of Thermo Scientific FlashSmart CHNS/O Analyzer using the MultiValve Control (MVC) Module

Your local gas generation partner. Precision series Modular gas generation solution for GC.

INSTRUMENT INSTRUMENT YL INSTRUMENT

Demystifying the Process of Calibrating your Thermal Desorption Gas Chromatography System using Compressed Gas Standards.

Markes Thermal Desorption Systems Site Preparation Page 1 of 8

This GC has two columns (I think new columns can be ordered from Restek)

Superior Result from Analytical Instruments The constant purity of the nitrogen improves system stability and ensures reproducible results

Environmental Petrochemical, Pharmaceutical, Foods & Flavors, Chemicals, Personal Care, Forensics,...and more!

Gas Chromatography. MS Vent Enhancement to the PreVent System to Optimize Operation with the TurboMass, TurboMass Gold, and Clarus 500 GC/MS Systems

3-Way Decoking Valve Option - Installation and Operation Instructions Accessory G Background

490 Micro GC Site Preparation Checklist

6850 Series Control Module User Information

Customer Responsibilities. Important Customer Information GCMS QQQ Site Preparation Checklist

Agilent 7890 Series Gas Chromatograph

STANDARD OPERATING PROCEDURES

Site Preparation Specification for GCMS system. Dimensions and Weight. Agilent 5975C MSD Series G3170A, G3171A, G3172A, G3174A

A Column-Flow Independent Configuration for QuickSwap. Application. Authors. Abstract. Introduction

Multiple Gas#5 GC configuration Jan 2016

The Tekran Series 2600-IVS Difference!

Low-Pressure Retention Time Locking with the 7890A GC. Application. Authors. Abstract. Introduction HPI

Instant Connect Helium Saver Injector Module

CP-3800 GC Operator s Manual

STANDARD OPERATING PROCEDURES

Agilent G Rebuilt Electron Capture Detector

Carrier Gases in Capillary GC

Bernhard Thomas September EnCal 3000 prochain Energy in Gas with ROI

Agilent 7800 ICP-MS. Specifications and Typical Performance. Fast track metals analysis with Solution-Ready ICP-MS

Three Columns Gas Chromatograph Analysis Using Correlation between Component's Molecular Weight and Its Response Factor

Agilent 7890 / 220 Ion Trap GCMS Site Preparation Checklist

System Overview. TCD Detector temperature setpoint Regulator

Super-Clean Gas Filters from Restek

Usage Policies Notebook for NanoFurnace Furnace (EasyTube 3000 System)

Mass Spec will not Autotune

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment Varian 310

Test Report # Rev 0. AP1500 and AP1400T Gas Permeation Tests

LINEAR TRANSFORMATION APPLIED TO THE CALIBRATION OF ANALYTES IN VARIOUS MATRICES USING A TOTAL HYDROCARBON (THC) ANALYZER

Inert Air (N2) Systems Manual

Please refer to the Hydrogen Safety Guide which is shipped with the Instrument. 5977B Series GC/MS Systems Site Preparation Checklist

Quick Reference Guide. OPTIC 3 - PTV on Shimadzu GC-2010 Gas Chromatograph

Gases and welding distributors continue

490 Micro GC Site Preparation Checklist

AKTA pure 25 New Owner s Intro

Experiment GC : Analysis of BTEX by GC-FID

Toxicology Gas Chromatography-Mass Spectrometry (GC-MS)

The HumiPyc - Model 1 - Gas Pycnometer; Density, Moisture, Permeation Analyzer; RH sensor Calibrator

The HumiPyc ( Model 2) - Gas Pycnometer; Density, Moisture, Permeation Analyzer; Filter Integrity Tester; RH sensor Calibrator

PERFORMANCE SPECIFICATION PROPELLANT, HYDROGEN

Jaap de Zeeuw Restek Corporation, Middelburg, The Netherlands. Copyrights: Restek Corporation

Automated Determination of Dissolved Gases in Water By Headspace Calibration of Mixed Gases Anne Jurek

Gas Diluter Portable Gas Dilution System User s Manual

Agilent 490 Micro GC Natural Gas Analyzer

no peaks missing peaks too small peaks increasing retention decreasing retention

Agilent G3185B QuickSwap Accessory

STANDARD OPERATING PROCEDURES

Transcription:

A New GC/MS System Designed for Helium Carrier Gas Conservation Approaches for the Smarter Use of Helium Dale R. Walker GCMS Applications Specialist August, 7, 2013 1

Helium Facts How it's produced Where did it all go? What can you do conserve? Is there an alternative gas? 2

Helium Facts A brief history of Helium Created by radioactive decay of heavy radioactive elements Primarily Thorium and Uranium Produces Alpha particles which form He nuclei Trapped in Natural Gas Fields mainly in American Great Plains Up to 7% by volume Separated from natural gas by low temperature fractional distillation 3

Helium Facts continued. National Helium Reserve - Amarillo, Texas (Dept. of Interior) Fed by 425 mile pipeline from Kansas to Texas Five Helium plants feed the pipeline 1996 Congress decided to phase out the Helium Reserve Helium Reserve was $1.4 Billion in debt in 1996 Plan is to empty the reserve to recover the funds Expected to be empty by 2018 As of 2012 the Reserve supplied 30% of the worlds Helium 4

Helium Facts cont. For many years the U.S. supplied 90% of the world s Helium New plant in Algeria can supply all of Europe s demand Other plants are now on line in Canada and Poland U.S. maintains reserves in Kansas, Oklahoma, and Texas New plants coming on line Wyoming, Qatar, and Russia New plants are not expected to ease the shortage 5

Helium Facts cont. Most Helium is used for cryogenics (MRI s) and welding Also controlled atmospheres such as wind tunnels Gas Chromatography is a minor consumer Prices are expected to continue to rise From 2002 to 2007 world prices doubled From 2007 to 2013 world prices have more than doubled again 6

Helium Facts continued What can you do? There are only two realistic choices: Option 1: Implement Helium conservation measures. This approach extends the lifetime of existing Helium supplies, reduces operating costs, and ensures business continuity. Option 2: Switch to a different carrier gas such as Hydrogen. 7

Option 1: Helium Conservation Environmental Protection Agency, Region 6 Houston, Texas The Environmental Protection Agency (EPA) Region 6 Laboratory is working with manufacturers to find solutions to the ongoing Helium shortage that is affecting many laboratories. 8

Option 1: Helium Conservation Approach 1: Manual switching valve A manual switching valve is connected to both a Nitrogen and Helium cylinder and is manually switched at the end of each day, this requires someone to be physically present to switch the valve. 9

Option 1: Helium Conservation An example installation The EPA tested manual valve switching and found it suitable 10

Option 1: Helium Conservation This simple cost saving alternative to switching carrier gases can be implemented immediately, with no time needed for method development, and without any noticeable effects on hardware or performance. Depending on the total number of instruments and the time between sequences, this procedure has the potential to save laboratories thousands of dollars per year by conserving Helium. 11

Option 1: Helium Conservation Approach 2: Automated valve A better approach is to use an automated switching device that delivers Helium or Nitrogen to the GC flow control modules. This type of automatic valve switching is preferred to the manual valve because it does not require user interaction. This switch may be programed to engage or disengage at the beginning or the end of your analytical run or sequence. 12

Option 1: Helium Conservation Automated switching valve: SW controlled To injection port Nitrogen Helium 13

Option 1: Helium Conservation Switching the Carrier with the Carrier Saver switch Helium carrier in forward flow Helium Carrier To injection port(s) During GC-MS operation < 100-psi N 2 trap He trap < 100-psi Helium Nitrogen 14

Option 1: Helium Conservation Switching the Carrier with the Carrier Saver switch During GC-MS downtime < 100-psi N 2 trap Nitrogen Carrier To injection port(s) He trap Helium back flushing column prevents intrusion < 100-psi Nitrogen Nitrogen carrier in injection port ONLY Helium 15

Option 1: Helium Conservation Switching the Carrier with the Carrier Saver switch Approach 3: Automated Helium conservation Seamless integrated system includes GC hardware and software control which allows laboratories to integrate programmable Helium conservation into the daily operation of the GC or GC/MS system. 16

Option 1: Helium Conservation Introducing the Programmable Helium Conservation Module Combines with 7890B Sleep-Wake feature Automatically switches carrier gas supply to N 2 during GC idle time TWO Critical Components Carrier gas switching EPC module 7890B Sleep/Wake Feature Plus Chromatographic grade N 2 gas 17

Carrier Gas Switch EPC Module Ensures Business Continuity To Inlet EPCs Purge Built on 5 th generation EPC Fully integrated and controlled by OpenLAB CDS Flow channel inside the bridge block N 2 in Std. Aux EPC He in Purge channel prevents cross contamination of gases Precise pressure control between tank and GC In AWAKE mode, switches between gases within 15-30 min for most detectors including MSD 18

Option 1: Helium Conservation Introducing the Programmable Helium Conservation Module 19

Option 1: Helium Conservation Introducing the Programmable Helium Conservation Module Greater reliability Based on proven 5 th generation AUX EPC Provides Nitrogen substitution when the GC is idle It also provides additional warnings if set points are not reached. This safety feature is very important when using Hydrogen. If a leak is detected an auto shutdown occurs and it remains in that state until reset by the user. 20

Option 1: Helium Conservation Introducing the Programmable Helium Conservation Module Greater performance Purge channel prevents cross contamination of gases and acts as an intermediate pressure regulator from the tank to inlet EPC to ensure greater analytical precision. Because there are no changes during the analytical sequence this eliminates the need for method revalidation. 21

Option 1: Helium Conservation Introducing the Programmable Helium Conservation Module Seamless integration Fully integrated within the 7890B GC (Open LAB, Chem Station, Mass Hunter) Method identifies both gases and uses the appropriate flows for each gas. Switching between each gas is easily implemented using new OpenLAB Sleep/Awake functions. 22

Option 1: Helium Conservation Introducing the Programmable Helium Conservation Module The new Agilent Open Lab CDS software provides many possible Sleep/Wake program configurations and operates much like a programmable home heating system. 23

Option 1: Helium Conservation Introducing the Programmable Helium Conservation Module You program the 7890B GC to load the Sleep method when not in operation, this eliminates the use of Helium by using Nitrogen as a carrier gas. 24

How Does It Work? Helium Conservation Mode (Sleep Mode with Nitrogen Carrier) 1.0 ml/min (out) AUX EPC 1 Nitrogen 70 psig 25.2 ml/min N 2 AUX EPC 3 Purge Vent 10 psig AUX EPC 2 Helium 0 psig (< 0.2 ml/min) He Bridge Block 24.2 ml/min N 2 Helium OFF, Nitrogen ON at 70 psig To GC Inlet EPC 25

Option 1: Helium Conservation Introducing the Programmable Helium Conservation Module You program the Wake method to load just before the start of the workday, this restores helium as the carrier gas so the GC system is completely ready and waiting to run samples. 26

How Does It Works? Normal Operation Mode (Wake Mode with Helium Carrier) 1 ml/min (out) AUX EPC 1 Nitrogen 0 psig AUX EPC 3 Purge 1.0 psig AUX EPC 2 Helium 80 psig (< 0.2 ml/min) N 2 25.2 ml/min He Bridge Block 24.2 ml/min He To GC Inlet EPC Helium ON at 80 psig, Nitrogen OFF GC/FID Wake Method: 15-30 Min GC/MS Wake Method: 15-30 Min Some other detectors may need longer 27

Option 1: Helium Conservation Introducing the Programmable Helium Conservation Module For GC and GC/MS systems, it only takes 15 minutes to completely remove all of the Nitrogen from the internal GC flow paths. The GCMS will pass the Nitrogen background test and be available to start the analytical sequence within 20 minutes of loading the wake method. 28

Programmable Helium Conservation Module Perfomrance Testing: Switching from Helium to Nitrogen Running Helium only Running Nitrogen in the injection port overnight Running over a weekend with Nitrogen purge in the inlet shows no backdiffusion of Nitrogen into the MS 29

Performance: No Change in Chromatography After N 2 Carrier Sleep Method (GC/FID) Day 1 - Original He carrier gas run Day 2 First He carrier gas run after overnight N 2 Sleep.M method Day 3 First He carrier gas run after overnight N 2 Sleep.M method 14 16 18 20 22 24 Min. 30

Counts Performance: Pass MS Tune Within 15min After Switching From N 2 to He as Carrier (GC/MSD) Nitrogen Background 5000000 500000 50000 5 ml/min He 2 ml/min He 5000 0 5 10 15 20 Time (min) Counts of Nitrogen Ion Time (min) 5 ml/min He Relative to Saturation 2 ml/min He Relative to Saturation 3 1735168 20.69% 8388096 100.00% 4 1033280 12.32% 4959232 59.12% 5 590080 7.03% 1618944 19.30% 6 354112 4.22% 722944 8.62% 7 228480 2.72% 333696 3.98% 10 56984 0.68% 102576 1.22% 15 9052 0.11% 17080 0.20% 31

Carrier Gas Savings Calculator Save Helium by > 90% compared to a typical use Helium supplies last MUCH longer Gas saver mode: 9 times longer N 2 standby: another 3.3 times more Total save: last 30 times longer 32

Carrier Gas Savings Calculator Change values in gray boxes to calculate savings for your operating parameters Method: Column: ASTM D7504 - Analysis of Trace Impurities in Monocyclic HP-INNOWax, 30 m x 0.32mm ID x 0.25 um Gas Flow Conditions He Carrier Flow (ml/min): 1.2 He Split flow (ml/min): 190 Gas Saver Flow (ml/min): 20 Gas Saver On (min): 3 Run Time(min.): 30 Gas Volume in Cylinder (L): 8000 Runs per Day: 15 He Cylinder Cost ($): 300 N2 Cylinder Cost ($): 60 Parameter No Gas Saver Gas Saver On Gas Saver + N 2 Standby Daily He Usage (L) 275 30 9 He Cylinder Life (days) 29 265 873 Daily N 2 Usage (L) 0 0 21 N 2 Cylinder Life (days) 0 0 381 Yearly He Cost ($) 3,769 413 125 Yearly N2 Cost ($) 0 0 57 Yearly Total Gas Cost ($) 3,769 413 183 33

Option 2: Hydrogen Carrier Hydrogen is great for many GC methods such as ECD and FID. Many people have been successful switching their GCMS methods to Hydrogen carrier gas as well Vince Marti at Region 8 lab for 8270 and 8260 Vince uses cylinder Hydrogen Lisa Wool at Region 6 for Pesticide s, PCB s, TPH Lisa uses a Hydrogen generator 34

Option 2: Hydrogen Carrier However, Hydrogen is not the best gas for GCMS methods. Depending on the method requirements The main issue with Hydrogen carrier is that it is not inert There is some reactivity with specific compounds Reactivity with Dichloromethane forms HCL in the GC inlet (Vince Marti in Region 8 discovered cooler inlet temps avoid this problem) BFB tuning anomalies can occur (ion 96) DFTPP tuning seems to be less effected 35

Pertinent Application Notes Reducing Helium Costs more than 10-fold with the PCT Gas Saver mode Agilent Technologies, Inc., April 1, 2010 5990-5444EN Prevent Business Disruptions by Managing your Helium Usage Agilent Technologies, Inc., April 30, 2013 5991-2256EN Successfully converting from Helium to alternate gases when analyzing VOC s following EPA 524.2 methodology Agilent Technologies, Inc., August 2013 36

Original Designers of Each System Fred Feyerherm, PhD Harry Prest, PhD Jim McCurry, PhD Bruce Quimby, PhD 37