Reference Guide. Correct Usage of EasySpray and Duplospray Pressure Regulator

Similar documents
Annex II. Scientific conclusions and grounds for variation to the terms of the Marketing Authorisations

The NAMIC Dream Kit. Single Operator Control. Reduce Contrast Waste. Less Force to Inject. Compensator * Manifold. How the Compensator Manifold Works:

INSTRUCTIONS FOR USE - US RaplixaSpray (Raplixa Delivery Device)

Digital Display large color coded LED display is easy to read precise measuring shows actual cuff pressure

INSTRUCTIONS FOR USE (US)

TOURNIQUET SYSTEMS & PRESSURE INFUSION

Welcome to the Specialized Medical Services Respiratory training webinar series!

Frigitronics CRYO-PLUS

DIAGNOSTIC CARDIOLOGY

TOURNIQUET SYSTEMS & PRESSURE INFUSION

MyoSure Setup Simplified

Operation and Maintenance of the EPV200 Portable Ventilator

Tentec. Instruction Document. Mini Air Driven Pump Unit Model: HTT.627X Series. Part Identifier

nual cylinder change-over unit N) manual Automatic gas cylinder change-over unit Operating manual

Compatible Baxter IV Sets

Nitrogen Tyre Inflator Owner s Manual

Patients come in a range of sizes. Now your oxygenator does, too.

Operation Manual - PN A MENSOR MODEL 73 SHOP AIR BOOSTER

750 Cable Cutter INSTRUCTION MANUAL

DONOR TM Pre-Evacuated Post-Operative Autologous Blood Reinfusion System

Table of Contents. Operating Instructions. Resource v.2 Conserving Regulator

STANDARD OPERATING PROCEDURES DIVISION OF COMPARATIVE MEDICINE UNIVERSITY OF SOUTH FLORIDA

Model 300 Dispensing Systems. Systems User Guide

Stainless Steel 142 mm Filter Holder YY

TJF-Q180V Cleaning and Disinfection Checklist

Tourniquet Systems Pressure Infusion

Installing ASI Umbilical Delivery Systems

INTRODUCING CARDIOSAVE Hybrid MORE THAN A PUMP. A REVOLUTION. SPECIFICATIONS

AUTOVENT 4000 VENTILATOR

Digital Tourniquets. Product Details. For electricity VAC, 50/60 Hz

Servo UNIVERSAL ADVANCED VENTILATION PLATFORM ALL PATIENT CATEGORIES

Universal Valve Company Inc

Medical Instruments in the Developing World

Universal Valve Company Inc

256 Pneumatic Pressure Indicator

TJF-Q180V Cleaning and Disinfection Checklist

Prescriptive Oxygenation

Operating Manual. Models AQT-02 & AQT-COO2 Manual No. MON004 (Rev 2 April 2000)

300 Held Drive Northampton Pa

PRESSURISED PAINT CONTAINER

Alfred ECMO Circuit Priming and Storage Guide

Before using or working with the Grab n Go Heliox system, please read and understand the usage and safety instructions provided in this booklet.

Operation and Maintenance of the MCV100 and MCV100-B Portable Ventilator

PRO SINK -R 1 and 2. Dilution system CONTENTS

UNDERSTANDING, ACCELERATED

CONGRATULATIONS ON YOUR PURCHASE OF YOUR THUNDER COMPRESSOR For your personal safety please read, understand and follow the information provided in

D Quality and Precision you can Trust in Oxygen Administration CONVENTIONAL FLOWMETER DIGITAL FLOWMETER COMPACT FLOWMETER

Aespire 7100 Essential performance Compact design

ARC Unofficial Manual to the Solvent Dispensing System. Designed by J. C. Meyer

OXY-VIVA 3 RESUSCITATOR OPERATING INSTRUCTIONS

STATEMENTS OF FACT BENCH BG-4 CONTEST. 1. A positive pressure leak could be caused by a leakage in or at device components.

COMPACT TRIPLE WALL OUTLET STATION MODEL INSTALLATION AND OPERATING INSTRUCTIONS

PRODUCT CATALOGUE OF

throat/pharyngeal pack

SINORIX Valve Reconditioning

Airless-Spraying Equipment. SuperFinish31. Fully equipped. More power. Innovative QLS technology

Procedure 85 Attaching The Humidifier To The Oxygen Flow Meter Or Regulator. Procedure 86 Administering Oxygen Through A Nasal Cannula

accidents which arise due to non-observance of these instructions and the safety information herein.

Nozzles and portable monitors

Tridak Model 1050 User Guide

Instructions for Cleaning & Maintaining Air Compressor

Air Plus User Manual

General Anaethesia Airway

STATEMENTS OF FACT BENCH BG-4 CONTEST. 1. A positive pressure leak could be caused by a leakage in or at device components.

Heart/Lung Perfusion Packs INSTRUCTIONS FOR USE

SECRETARY OF THE AIR FORCE 17 APRIL 2000 LOADMASTER MAFFS CHECKLIST. Summary of Revisions: Redundant pages removed.

100L AIR COMPRESSOR MODEL NO: TIGER 16/1010 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS01/13

Instructions for use Evacuation system compressed air injector SL 20 / SL 20 Max SL 30 / SL 30 Max

DATA SHEET. VENTILATION SERVO-s

Mass Casualty Ventilator

Rev. B. Operating Instructions

Disposable Transducers

CPR MEDICAL DEVICES INC. OPERATING MANUAL

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50 Systems Outfitted with ABM-725 Monitor C O M P A N Y

KEG PUMP. Range of Electric Keg Pumps

INFUSION SYSTEM (110V) (220V) USER S MANUAL

Dialflow Regulator. Instructions for Use

INSPIRE Min.I. Redefining minimally invasive approach to perfusion. Expand your choices with INSPIRE Min.I.

COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: WARRIOR 55 PART NO: (110V) , (230V) , LS0512

SCK01 AIR COMPRESSOR KIT WITH QUICK FITTINGS - SPRAY/BLOW/OIL GUN, TYRE INFLATOR & HOSE

Hi-Force Limited Prospect Way Daventry Northants NN11 8PL United Kingdom Tel: +44(0) : Fax: +44(0) : Website:

3:1 High Ratio Oil Pump W. Extn. Kit

Mass Casualty Ventilator Models: MCV100 & MCV100-B

Techcon Systems TS1258 Pressure Pot

Clinician Guide. Baxter Elastomeric Devices. Promoting patient-centric care

HANDBOOK. Squeeze Off Unit SOU 400. Please refer any queries to:

Hallowell EMC 2000 and 2002 Veterinary Ventilator Set-up, Use, and Troubleshooting

XpressFill XF2500 Counter Pressure Filler. Operating Instructions

Simplified Automated Ventilator Training Slides

ACCU-PULSE Installation and Operation Instructions

Technical Data and Specifications

CDI System 500. Blood Parameter Monitoring System. Continuous blood parameter monitoring for improved blood gas management

Budget Range Operators Handbook

Bleeding Trauma Module Set. Directions for Use

REDUCER REDUCER REDUCER

Spray Gun 134-A. 1 Liter High- Pressure Gel Coat. Usage Instructions & Parts List

Instruction Manual Updated 7/26/2011 Ver. 2.2

FILTER REGULATORS MODEL NO: CAT155 & CAT156 FITTING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS

O P E R A T O R S M A N U A L

Transcription:

Reference Guide Correct Usage of EasySpray and Duplospray Pressure Regulator b

EASYSPRAY and DUPLOSPRAY MI EASYSPRAY Pressure Regulator Operation (open surgery) 1 Insert 9V battery into the EASYSPRAY Pressure Regulator device 4 Connect Spray Set filters to EASYSPRAY device. Connect the blue filter to the blue female luer connector and the clear filter to the male luer connector 2 Connect EASYSPRAY device to IV pole or cart rail using the clamps on the back of the device 5 Turn the on/off switch on the front side of the EASYSPRAY to the ON (I) position 3 Use suitable connection tube to connect the EASYSPRAY device to medical air (ranging 3.5 7 bar / 50 100 psi) 6 Check the gauge on the EASYSPRAY device for the appropriate pressure range of 1.5-2.0 bars (21.5-28.5 psi). Adjust pressure setting by turning the black pressure control knob DUPLOSPRAY MIS Pressure Regulator Operation (laparoscopic procedures) 1 Position DUPLOSPRAY System so the foot pedal is placed next to the surgeon s foot at time of application 2 Attach gas supply hose, located at back of regulator, to source of medical grade CO2 3 Attach spray set to regulator. Connect the blue vent line filter to the blue female luer and the clear gas line filter to the male luer on the regulator 4 While depressing foot pedal, adjust gas flow rate to 1.0-2.0 liters per minute. Check gas flow by noting height of ball in flow gauge while stepping on foot pedal 5 Depress foot pedal to start gas flow prior to applying TISSEEL Fibrin Sealant. Check gas flow gauge on regulator before inserting applicator. If flow level ball does not move when foot pedal is depressed, the applicator tip is occluded and should be replaced

Y MIS Pressure Regulator - Instructions for correct usage CAUTION BOX Any application of pressurised gas may be associated with a potential risk of air or gas embolism, tissue rupture or air or gas entrapment with compression, which may be life threatening if the product is sprayed incorrectly Precautions For TISSEEL Fibrin Sealant and ARTISS Solutions for Sealant b In open-wound surgery: when applying sprayable fi brin solutions for sealant using a pressure regulator device, the maximum pressure should be 2.0 bar (28.5 psi). The product should be sprayed at a distance at least 10 cm from the tissue surface. b Spray application should only be used if it is possible to accurately judge the spray distance as recommended by the manufacturer. Do not spray closer than the recommended distances. b Prior to applying sprayable fi brin solutions for sealant, the surface area of the wound should only be dried using standard techniques (eg, intermittent application of compresses, swabs, use of suction devices). b Blood pressure, pulse rate, oxygen saturation and end tidal CO 2 should be monitored closely when spraying fi brin solutions for sealant using a pressure regulator device, because of the possibility of occurrence of air or gas embolism. b Regulators should be used in line with manufacturer recommendations and the SmPC and Instruction for Use. For TISSEEL Fibrin Sealant only b In laparoscopic procedures:use CO 2 only when using spray application. When applying the product as a spray using a CO 2 pressure regulator device, the maximum pressure should be 1.5 bar (22 psi). The product should be sprayed at a distance at least 2cm (recommended range 2-5cm) from the tissue surface. For ARTISS Solutions for Sealant only b ARTISS is recommended for subcutaneous use only. ARTISS is not recommended for laparoscopic use.

Fibrin Sealant Surgery Spray set to be used Applicator tips to be used Open surgery TISSEEL/ARTISS Spray Set TISSEEL/ARTISS Spray Set 10 Pack DUPLOSPRAY MIS Applicator 20cm TISSEEL DUPLOSPRAY MIS Applicator 30cm Laparoscopic/ minimally invasive procedures DUPLOSPRAY MIS Applicator 40cm Replaceable Tip ARTISS Open surgery TISSEEL/ARTISS Spray Set TISSEEL/ARTISS Spray Set 10 Pack Laparoscopic/ minimally invasive procedures n.a n.a Caution: Any application of pressurised gas may be associated with a potential risk of air or gas embolism, tissu appropriate measures to address these risks by observing the recommended minimum spraying distance and the

Recommended Pressure and Distance Overview Pressure regulator to be used EASYSPRAY EASYSPRAY Recommended distance from target tissue 10-15cm Recommended spray pressure/flow rate 1.5-2.0 bar (21.5-28.5 psi). DUPLOSPRAY MIS Regulator DUPLOSPRAY MIS Regulator NIST B11 DUPLOSPRAY MIS Regulator DUPLOSPRAY MIS Regulator NIST B11 DUPLOSPRAY MIS Regulator 2-5 cm 1.0-2.0 L/min (1.2-1.5 bar/ 18-22 psi) DUPLOSPRAY MIS Regulator NIST B11 DUPLOSPRAY MIS Regulator DUPLOSPRAY MIS Regulator NIST B11 EASYSPRAY EASYSPRAY 10-15cm 1.5-2.0 bar (21.5-28.5 psi) n.a n.a n.a tissue rupture or air or gas entrapment with compression, which may be life threatening. Be sure to take the maximum pressure provided in the appropriate spray set instructions for use and in the table above.

Notes

b Baxter Healthcare Ltd Wallingford Road, Compton Newbury, RG20 7QW Surecall Tel: +44 (0) 1635 206345 Surecall Fax: +44 (0) 1635 206071 Email: surecall@baxter.com For detailed information please contact your local representative. Baxter, Tisseel, Tissucol, Artiss, Duplospray, and Easyspray are trademarks of Baxter International Inc., ist subsidiaries or affiliates UK/MG24/13-0003 September 2013