Operating Instructions

Similar documents
Safety instructions and operating manual

User manual. ZX trolley.

OPERATING AND MAINTENANCE MANUAL GOLD LINE EXTRACTION CLEANERS M14-M26

Setup Guide for your HVO Naked Drone

DK46 - DK800 Supplementary instructions

original operating manual Operating manual TankQuick 100 F2 Translation of the Item-No.:

SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER

SAFETY POLICY AND PROCEDURE MANUAL All Euramax Subsidiaries. Number K-3.0 Welding Safety Procedures

User Manual. Quantos Automated Dosing Liquid Module

Safety, Set-Up, and Operating Instructions

400H HARDMOUNT AIR COMPRESSOR KIT PART NO H HARDMOUNT AIR COMPRESSOR KIT PART NO

H-1000 Fuel Cell Stack User Manual

VERTICAL AIR COMPRESSORS

Columbus Instruments

Med Aire Alternating Pressure Pump and Pad System

MANUAL DIRECT PURGE OPTION. UNION Instruments GmbH CWD2005 PLUS. General information, safety standards and regulations for direct purge option

INSTALLATION GUIDE Gas Rangetops

Instrument Operating Manual

50L ENGINE DRIVEN AIR COMPRESSOR MODEL NO: XPPV11 & XPP15 RANGE

AIR-OPERATED DOUBLE DIAPHRAGM PUMP USER S MANUAL

ALU-CD 12, ALU-CD 25, ALU-CD 35, ALU-CD

Chapter 2 Preparations for Tank Cleaning Work

12 Volt Inflator. Operator s Manual. Model: ICC12F, ICC12FC, ICC12FCN, ICC12FCM, ICC12N

Cal/OSHA T8 CCR 1536 Cal/OSHA T8 CCR 4799 Cal/OSHA T8 CCR 4845 Cal/OSHA T8 CCR 4848

VERTICAL AIR COMPRESSORS

Permit-To-Work Guidance and Templates

Technical Data Sheet MF010-O-LC

I. Subject: Compressed gas cylinders, regulators, and portable liquid systems.

Instruction and Maintenance Manual

User Manual V14.1 IP68 LED FLEX NEON

CITY AND COUNTY OF DENVER CR&CF RISK UNIT Compressed Gas Safety Standard

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

HSE guidelines. SMay 2015 ELECTRICAL SAFETY HSE LIFE THE NATIONAL OIL&GAS INDUSTRY STANDARD FOR PROFESSIONALS

03/07/2014 V

GAS BBQ 4 burner. instructions for. model no: BBQ10

450P- RV AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

MODEL NUMBER: PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank

EXPLOSIVE ATMOSPHERES - CLASSIFICATION OF HAZARDOUS AREAS (ZONING) AND SELECTION OF EQUIPMENT

450P AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: WARRIOR 55 PART NO: (110V) , (230V) , LS0512

Installation and Maintenance Manual. ECO Filtration Unit with 6-way-Top-Mount-Valve. Art. Nr

MODEL NUMBER: M20005 AIR SOURCE KIT. 30% Duty Compressor on. 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE

FIRE AND EXPLOSION HAZARD MANAGEMENT

MODEL NUMBER: P-A AUTOMATIC PORTABLE COMPRESSOR

Training Title IDENTIFY OPERATIONAL UPSETS, REVIEW & VALIDATE IN OIL & CHEMICAL PLANTS

AQUARIUS. Operating Instructions for the. Type 70 Electrolytic Gas Soldering / Welding Unit. Table of Contents

PRESSURISED PAINT CONTAINER

Risk Management Department. Compressed Gas Safety

MSDS Interspiro Spiroscape EEBD (compressed breathing air)

DSEAR- Storage, Use and handling of gas cylinders guidance.

Manual Actuated Boiler Blowdown Valves

Gas Fired Residential Heating Boilers

General Precautions for handling compressed gases

SUMMITTM 400 & 600. Natural Gas Barbecues. Step-By-Step Guide

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

USE AND MAINTENANCE LIGHT TOWER

Describe Flammable Gas Measurement

Safety Data Sheet BUTANE Legislation 1907/2006/EG

USER S INFORMATION MANUAL

FILTERING ELECTRICAL INTERFERENCE

for the of and the EM55-1

DATA SHEET Revised edition no : : flammable gas. M M«

User Manual. Quantos Automated Dosing Liquid Module

Liquid Nitrogen Cooling Accessory CE

Welding, Cutting, and Brazing

Technical Information

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

DATA SHEET Revised edition no : 0. o óm MÁM M« : Industrial and professional. Perform risk assessment prior to use. Company identification

MATERIAL SAFETY DATA SHEET. Oxygen, Refrigerated Liquid DOT Hazard Class: 2.2

Operating Manual ALU 7 - ALU 10 - ALU 20 - ALU 26 ALU 35 - ALU 60 - ALU 100

TECHNISPRAY PAINTS LTD. Linton House, Catherine Street, Aston, Birmingham B6 5RS U.K. Tel: ++44 (0) Fax: ++44 (0)

ISO INTERNATIONAL STANDARD. Small craft Liquefied petroleum gas (LPG) systems

200 PSI COMPRESSORS - MODEL NUMBERS

ECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION

Safe Work Instructions For Oxygen Acetylene Equipment

100C Air Compressor Kit

24L OIL FREE AIR COMPRESSOR MODEL NO: TIGER 7/250 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS10/13

BOC: Living healthcare. Manual. LIV IQ BOC Integrated Valve with digital display portable delivery system for Medical Oxygen. BOC: Living healthcare

SAFETY DATA SHEET ACETYLENE (DISSOLVED)

IMPORTANT SAFETY INSTRUCTIONS

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

AMS 2710 PCB pressure sensor module with V output

SC505 Sof Care Inflator. Operating Instructions and Service Manual

Propane Conversion Kit Instruction

Instructions for High Altitude Conversion

Manual. Online Degasser DDG-75. Manual Degasser DDG-75 April DURATEC Analysentechnik GmbH Rheinauer Strasse 4 DE Hockenheim Germany

OPERATING INSTRUCTIONS

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

USER MANUAL LTH-255A Hand Piece

Confined Space Policy

DTC P0441 Evaporative Emission Control System Incorrect. DTC P0446 Evaporative Emission Control System Vent Control Malfunction

Assembly and Installation Procedures

MoveRoll Conveyor Operating and Maintenance Manual

SHHH AIR COMPRESSOR Model Nos. SHHH5/24 - SHHH5/50 - SHHH7/100

VT-0017 CWH OVERVIEW. intended provide PARTS NEEDED. a cryogenic tank. avoid gas from. proper PPE tanks & testing. LNG. Review.

MODEL NUMBER: P PORTABLE COMPRESSOR

NGP-250/500 Nitrogen Generator Quick Start Guide

MAGNUM MIG 190 II DIGITAL INSTRUCTIONS MANUAL

RG6000. Refrigerant Recovery Machine. Operating Manual. 99 Washington Street Melrose, MA Phone Toll Free

444C DUAL PERFORMANCE VALUE PACK

Transcription:

Operating Instructions www.fuelcellstore.com sales@fuelcellstore.com E101/E102 Electrolyser 5 / 10 E103/E104 Electrolyser Cell5 / Cell10 Overview Electrolyser side of the gas storage tank Compensation tanks Oxygen- (O 2 ) outlet Oxygen- (O 2 ) side of the electrolyser Hose clamps Gas storage tanks Hydrogen- (H 2 ) outlet Sockets for DC voltage source (red=+, black=-) Hydrogen- (H 2 ) side of the electrolyser Fuel cell side of the gas storage tank

General Safety Precautions The units may only be set up and operated by a responsible supervisor. WARNING! Not suitable for children under 12 years! Read the Operating Instructions before setting up the fuel cell. Follow them during use and keep them readily available for reference. The equipment may only be used with h-tec solar modules (h-tec Solar Module Basic, Art.-Nr. 2086; Solar Module Tutorial, Art.-Nr. A113; Solar Module Tutorial Double, Art.-Nr. A118), h-tec batterybox (BatteryBox, Art.-Nr. A115) or h-tec plugin power supply (h-tec PowerSupply, Item No. 2033). Wear protective goggles. Equipment and gases must be used and stored out of the reach of small children. Plug-in power supplies can be dangerous - they are not toys! Disconnect the unit from the plug-in power supply and the solar module before cleaning with liquids. Unless instructed to the contrary by the manual, do not reverse or short-circuit the connecting terminals. The units must not be operated when empty. Always ensure that they contain sufficient water. Pay attention to the water level marks. Remove flammable gases, vapours or liquids from the area surrounding fuel cells and electrolysers. The catalytic materials involved may cause spontaneous ignition. Hydrogen and oxygen may escape from the units. Operate the units in wellventilated rooms to ensure that the gases do not accumulate and form explosive mixtures. The units may only be operated in display cases if adequate ventilation is guaranteed under all circumstances. The operator is responsible for ensuring this.

General Safety Precautions Remove from the vicinity of the units anything that could ignite the hydrogen (e.g. open flame, materials that can become charged with static electricity, substances with a catalytic action). Remove from the vicinity of the units all substances that could spontaneously ignite in increased oxygen concentration. Do not smoke. Hoses, plugs and gas tanks are used for pressure compensation. They must not be fixed or secured with clamps, adhesive, etc. Only use the gas storage tanks associated with or supplied with the units. Never connect alternative gas storage tanks. The units may only be operated at room temperature and ambient pressure. Minimum separation distances must be observed when using solar modules and artificial lights. These are: 30 cm between h-tec solar modules and the h-tec Videolight, and 50 cm in the case of the h-tec Spotlight. When using lights from other manufacturers, observe the minimum distance specified by them. WARNING! The surface of solar modules can get very hot during extended operation. Tell your students about any potential dangers and carefully supervise experimentation. h-tec accepts no responsibility for injuries or damage sustained in the event that these Safety Precautions are not followed.

Setting up 1/3 Introduction This PEM electrolyser (PEM = Proton Exchange Membrane) uses electricity to break down distilled water into hydrogen and oxygen. Setting up Read the Operating Instructions and the General Safety Precautions before using any of the equipment. Note: Electrolyser 5 and Electrolyser 10 are pre-assembled, so users of these products can skip to No. 3. 1. Use four hoses to connect the top and bottom connectors of the electrolyser to the corresponding connectors on the electrolysis side of the gas storage tanks. 2. Fit hoses with hose clamps to the connectors on the fuel cell side of the gas storage tanks. 3. Fit hose clamps to the gas storage tank outlets and close them firmly. 4. Fill both storage tanks 1 with distilled water up to the top mark and then open the hose clamps one after the other. Air will escape from the gas storage tanks and from the electrolyser. The process is complete when the water level in the storage tanks stops falling (Fig. 1). Close the hose clamps once more.

Setting up 2/3 Gas production/storage 1. Connect a DC voltage source (e.g. solar module, h-tec PowerSupply or BatteryBox). When doing so, make sure that the polarity is correct (red = "+", black = "-") and observe the maximum permissible voltage (Fig. 2). 2 Important: The maximum permissible voltage for the Electrolyser 5 or the Electrolyser Cell5 is 2 V, and for the Electrolyser 10 or Electrolyser Cell10 is 4 V. 2. The current breaks down the water into hydrogen and oxygen in a ratio of 2:1. The gases collect in the gas storage tanks and displace the water there into the compensation tanks (Fig. 3). Warning: Make sure that no gases can collect above the compensation tanks. 3

Setting up 3/3 Emptying the storage tanks 1. Remove the hoses from the fuel cell side of the gas storage tanks and hold the storage tanks over a collecting tray as shown in Fig. 4 until they are completely empty. 4 Accessories Accessories (not included) Solar Module Tutorial Item No. A113 Solar Module Tutorial Double (for Electrolyser 10 or Electrolyser Cell10) Item No. A118 Gas storage tank Storage 30 Item No. A103 Plug-in PowerSupply Item No. 2033 BatteryBox Item No. A115 Maintenance The electrolysers we provide in our sets are maintenance-free. However, always remember: Use fresh, distilled water each time. Drain the water from the storage tanks after use.

Troubleshooting The electrolyser does not produce hydrogen when the solar cell is connected. Cause 1: The light intensity is insufficient. Solution 1: Check the power specifications of the light source. You need sufficient sunlight or halogen lamps with focused light such as the h-tec Videolight or h-tec Spotlight. Energy-saving lamps, fluorescent tubes, etc. are not suitable for the operation of solar modules. Cause 2: You are using a double-cell electrolyser (electrolyser 10 or electrolyser cell 10) and are running it with a solar module for single cells. Solution 2: Use the appropriate solar module - the Tutorial Double Solar Module. The electrolyser does not work despite being set up correctly. You have not used distilled water. The cell is permanently damaged.

Technical Data Electrolyser 5 (E101) Single-cell electrolyser with storage tanks on baseplate Electrolyser mode: 5 cm 3 /min H 2 2.5 cm 3 /min O 2 1.16 W Gas storage tank: 30 cm 3 H 2 / O 2 H x W x D: 90 x 170 x 135 mm Weight: 280 g Electrolyser 10 (E102) Double-cell electrolyser with storage tanks on baseplate Electrolyser mode: 10 cm 3 /min H 2 5 cm 3 /min O 2 2.33 W Gas storage tank: 30 cm 3 H 2 / O 2 H x W x D: 90 x 170 x 135 mm Weight: 290 g Electrolyser Cell5 (E103) Single-cell electrolyser Electrolyser mode: 5 cm 3 /min H 2 2.5 cm 3 /min O 2 1.16 W H x W x D: 50 x 40 x 50 mm Weight: 52 g Electrolyser Cell10 (E104) Double-cell electrolyser Electrolyser mode: 10 cm 3 /min H 2 5 cm 3 /min O 2 2.33 W H x W x D: 56 x 42 x 57 mm Weight: 63 g www.fuelcellstore.com sales@fuelcellstore.com