HYGIENIC SIGHT FLOW INDICATORS

Similar documents
Sterile Visual Flow Indicator

Hygienic Bubble Trap Installation and Operations Manual

Circular Sight Windows

Constant Pressure Crude Oil Container Model CPCCP

INSTALLATION & MAINTENANCE INSTRUCTION

Installation, Operation and Maintenance Manual for Back Pressure Regulator

CRP Ltd INSTALLATION, OPERATING AND MAINTENANCE INFORMATION FOR INLINE SYRINGE SAMPLING SYSTEMS

INSTALLATION, OPERATION AND MAINTENANCE GUIDE

Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0)

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual

CVS10 Sanitary Check Valves

Installation, Operation, and Maintenance Manual

Installation, Operation, and Maintenance Manual

// ADapters GUIDelines

Product Manual. Description. Specifications. CVS Type 1301F and CVS Type 1301G Regulator. Introduction

BTM7, BTS7 and BTS7.1 Stainless Steel Thermostatic Clean Steam Traps

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER RELIEF VALVE

CRP INSTALLATION, OPERATING AND MAINTENANCE INFORMATION FOR INLINE SAMPLING VALVES

AVM7 Stainless Steel Thermostatic Air Vent

Hot Tapping Machine. OPERATIONS MANUAL and OPERATING INSTRUCTIONS

SCA Series Inverted Bucket Steam Traps

THE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv)

Installation Instructions and valve Maintenance Rev. 0 of 21/09/15

Atmospheric relief valve type 1100 Installation and maintenance instructions

A3S Bellows Sealed Stop Valve Installation and Maintenance Instructions

WHEATLEY WHEATLEY SERIES 500 SWING CHECK VALVE. Installation, Operation and Maintenance Manual

Translation of the original Operating Instructions for HKS rubber compensators

Engineering Data Sheet

SALCO PRODUCTS, INC. PRESSURE RELIEF VALVE STORAGE, INSTALLATION, OPERATING, MAINTENANCE/TESTING, AND INSPECTION INSTRUCTIONS

Installation, Operation, and Maintenance Manual. XS150-ULV Urethane Lined Knife Gate Valve

MODEL 200 KNIFE GATE VALVES INSTALLATION & MAINTENANCE MANUAL

Installation, Operation, and Maintenance Manual

Sight Flow Indicators 300# & 600# ANSI Models:

COMBINATION AIR RELEASE DEGASSING (CARD) VALVES INSTALLATION AND MAINTENANCE MANUAL

Installation, Operation, and Maintenance Manual

Mooney * Noise Controller Installation, Operation, and Maintenance Manual

Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0)

Un-Pressurized Orefice Fittings FIO EZ. Parts List and Operation Instructions TECHNICAL MANUAL. Dn 2-6 Class Lbs

M45 ISO Ball Valve DN25 to 150 Installation and Maintenance Instructions

EASTERN ENERGY SERVICES PTE LTD. 60 Kaki Bukit Place #02-19 Eunos Tech Park Singapore, SG Singapore Telephone: Fax:

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER FILTER DRYER

Installation Instructions and valve Maintenance Rev. 0 of 29/09/15

Installation, Operation, and Maintenance Manual

WHEATLEY Series 500 Swing Check Valve

BUTTERFLY VALVES Series 800

USER INSTRUCTIONS. NAF Duball DL Ball Valves. Installation Operation Maintenance. Experience In Motion. flowserve.com

Threaded Closures Installation, Operation & Maintenance

Type BBS-03, BBS-05, BBS-06, BBS-25

Installation Operation Maintenance

PROPORTIONING VALVE. Model 150 INSTRUCTION MANUAL. March 2017 IMS Company Stafford Road

LIQUIP DRYBREAK COUPLER. API800 Series MAINTENANCE INSTRUCTIONS

Instruction Manual. Alfa Laval SB Pressure Exhaust Valve ESE02965-EN Original manual

Ball valve HKSF-W100. Ball valve HKSF-W100. RMA Kehl GmbH & Co. KG Oststrasse 17 D Kehl / Germany

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

JSRH Series. Sanitary Valves JSRH Series High Flow Pressure Reducing Valves. High Flow Bio-Pharma Clean Gas Pressure Reducing Valves

PP-1, PP-1W, PP-2, & PP-3

AIR HAMMERS MODEL NO: CAT138/CAT139 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: / GC064

Modular valve block. Operating manual Series MVB 100/200. Version BA EN Print-No TR MA DE Rev001

MANUAL. Sesame. Thermoplastic Tank Technologies

Type ACE97. Introduction. Installation. P.E.D. Categories. Specifications. Overpressure Protection. Installation Guide English May 2002

627 Series Pressure Reducing Regulators

SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER

Paintball Marker. User s Manual. 530 South Springbrook Road Newberg, OR 97132

BT6HC Hygienic Sanitary Balanced Pressure Steam Trap for High Capacity and CIP/SIP Applications

INSTALLATION, OPERATION AND MAINTENANCE MANUAL. Model Sanitary Vent SECTION I

JSR Series. Sanitary Valves JSR Series Ultra-High Pressure Reducing Valves. High Purity Bio-Pharma Gas Pressure Reducing Valves.

Piloted Non-Return Valves

GAS STRUT SAFETY INFORMATION

Supratec Gesellschaft für Umweltund Verfahrenstechnik mbh OXYFLEX - M T / M T M E M B R A N E D I S C D I F F U S ER AERATION TECHNOLOGY

Installation, operation & maintenance manual - original version

WELLS JOHNSON HIGH VOLUME CANISTERS

64 Series Pressure Reducing Regulators

ATS430 turbidity sensor Retractable insertion assembly

Operating instructions - Translation of the original -

Installation / Operation / Maintenance Manual KLINGER Reflex Level Gauge Type R 25

USM21 Sealed Bimetallic Steam Trap for use with Pipeline Connectors Installation and Maintenance Instructions

CA16 and CA16S-14 Air and Gas trap Installation and Maintenance Instructions

DelVal Flow Controls Private limited

WHEATLEY Series 822/820 Swing Check Valve

1.0 - OPENING AND CLOSING THE DOOR

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

Model VR6 System. Installation, Operation & Maintenance

H4802, H4802-1, H , and Pole Tampers

30T A/Manual Hydraulic Shop Press

PRESSURE TEST PUMP OPERATING & MAINTENANCE INSTRUCTIONS. Model No: PTP100. Part No: GC01/09

BTD52L Thermodynamic Steam Trap Installation and Maintenance Instructions

Installation, Operation, and Maintenance Manual. Welker Constant Pressure Cylinder With Solid Indicator (Non-mixer) Model CP-30SI

GILMONT ACCUCAL FLOWMETERS

Types 749B and R130 Changeover Manifolds

Operating Procedures for GripTight 15.5 SDR & IPS Test Plugs

CS10-1 Stainless Steel Clean Steam Separator

Pure-Flo Handwheel Operated Valves (903, 913, 963) Instruction Manual

Anderson Greenwood Series 93 Positive Pressure POSRV Installation and Maintenance Instructions

GEMS SENSORS & CONTROLS

Reduce pressure zone device suitable for high and medium hazard rated applications BSP screwed connections

Johnston Invar Coupling Johnston Invar Coupling

ACCUMULATOR OPERATING & MAINTENANCE INSTRUCTIONS

Assembly Drawing: W-311B-A01, or as applicable Parts List: W-311B-A01-1, or as applicable Special Tools: , , &

Operation and Maintenance Instructions

Contents. 1. General information BROEN BALLOMAX Steel Ball Valves Approvals Quality Management...2

Transcription:

Section: T500 Bulletin: T500.3 Date: 03/16/15 Supersedes: NEW HYGIENIC SIGHT FLOW INDICATORS Installation, Operation, and Maintenance Manual

Table of Contents 1. Introduction... 2 1.1. Specification... 2 1.2. Components... 3 2. Installation... 4 2.1. Unpacking... 4 2.2. Visual Inspection... 4 2.3. Positioning... 4 2.4. Commissioning / Start Up... 4 3. Maintenance... 5 3.1. Disassembly... 5 3.2. Assembly... 5 1

1. Introduction Clark-Reliance Hy-Sight hygienic inline flow indicators are designed and manufactured to provide an uninterrupted window for observation of the process flow in high purity applications. The inline tubular design has evolved to incorporate a number of features that ensure the internal area or flow path is smooth & crevice free, exceeding the requirements as governed by both the ASME BPE and 3A standards. As standard units are supplied with tri-clamp ended covering imperial OD tube sizes from 1/4 through to 6. 1.1. Specification The specified operating conditions for your Hy-Sight unit is tube size, pressure and temperature dependant, ensure your chosen Hy-Sight product conforms to the quick reference table shown below: Operating Tube Maximum Allowable Operating Temperature ( F / C) Pressure Size Bar OD PSIG EPDM Silicone FKM (Viton ) FEP/Silicone g 1/4" 300 21 265 129 450 232 400 204 450 232 3/8 300 21 265 129 450 232 400 204 450 232 1/2 300 21 265 129 450 232 400 204 450 232 3/4" 250 17 265 129 450 232 400 204 450 232 1 ALT 200 14 265 129 450 232 400 204 450 232 1 200 14 265 129 450 232 400 204 450 232 1 ½ 150 10 265 129 450 232 400 204 450 232 2 125 9 265 129 450 232 400 204 450 232 2 ½ 125 9 265 129 450 232 400 204 450 232 3 110 8 265 129 450 232 400 204 450 232 4 90 6 265 129 450 232 400 204 450 232 6 (FV) 70 4.8 265 129 450 232 400 204 450 232 If in any doubt regarding specification and suitability, please contact a member of the Clark-Reliance technical sales team, prior to installation. DANGER Exceeding designed operating pressures or temperatures could result in loss of containment, sudden escape of pressure could result in severe personal injury or property damage. 2

1.2. Components Each standard Hy-Sight assembly unit is comprised of five different components: Body Component Quantity: 1 Material: 316L Stainless Steel (standard, options available) Head Connection Quantity: 2 Material: 316L Stainless Steel (standard, options available) Glass Cylinder Quantity: 1 Material: 3.1 Borosilicate Glass (standard, Acrylic available) Sealing O-Ring Quantity: 2 Material: USP Class VI Elastomer, EPDM (Standard, options available) Centralizing O-Ring Quantity: 2 Material: USP Class VI Elastomer, EPDM (Standard) 3

2. Installation 2.1. Unpacking Your Hy-Sight unit is pre-assembled by Clark-Reliance and should arrive carefully packed and as one fully assembled unit. WARNING Care should be taken during the un-packing of the unit as all units contain glass components that have the potential to have been broken through mishandling. 2.2. Visual Inspection Upon receipt of your Hy-Sight unit visual inspect the unit for any sign of damage that may have of occurred during shipping or mishandling. During visual inspection, particular attention should be made to the glass cylinders internal and external surfaces. Any sign of chips, cracks or imperfections on these surfaces may potentially reduce the safe operating pressure as published. In the unlikely event of damage being discovered or suspected to do not attempt installation under any circumstances. 2.3. Positioning The Hy-Sight unit can me mounted in any orientation, vertically or horizontally with the flow passing through in either direction. Locating & positioning the unit should be given careful consideration, to optimise the life time of the unit, it is essential that the unit is not exposed to any of the following: a) Piping loads or torsional forces. (the unit is not designed to be load bearing) b) Sudden increases of pressure. c) Excessive vibrations. d) Rapidly fluctuating temperatures. e) Other moving parts. To maximise clarity of the media passing through the unit, we would recommend installation in a length of pipe that has 24 of straight line pipe either side of the unit, promoting a laminar flow through the viewable area. 2.4. Commissioning / Start Up Following correct installation, the Hy-Sight unit should be brought into service slowly, gradually building the pressure & temperature until the desired process values are reached. We would advise this is carried out during a CIP process where the unit can be checked for leaks prior to the process media being introduced. 4

3. Maintenance Periodic maintenance and inspection should be carried out on the Hy-Sight unit, the frequency of which will vary with application. The end user should determine the appropriate maintenance schedule based on their experience with the given application. Maintenance & inspection procedures should focus on the following areas: a) The screwed head connections remain tight and butted up against the body. b) The glass cylinder for signs of wear or damage. c) The sealing O-rings for signs of degradation, protrusion or intrusion. d) The centralizing O-rings for signs of degradation, resulting in a loose fittings glass cylinder. e) Corrosion to the stainless steel body or head connections. Elastomer based O-rings degrade over a period of time, this reduction in volume greatly affects the compressibility of an O-ring and in turn the sealing capability, resulting in a unit that may leak. We advise that both the sealing & centralizing O-rings are replaced to fall in line with the end users current gasket change out schedule. WARNING Do not attempt to carry out maintenance on the Hy-Sight unit whilst installed in pipework, ensure the pressure has been removed from the process line prior to unit removal 3.1. Disassembly Disassembly should only be carried out by trained personnel who are familiar with this IOM manual. The following steps should be taken: a) Release the tri-clamps from both ends of the Hy-Sight unit, remove the unit as a whole. b) Unscrew the head connections from the body, one at a time. c) Carefully remove the glass from the body. d) Remove the O-rings from both the glass cylinder and/or the head connections. Used O-rings should be disposed of immediately, never try to re-assemble the Hy-Sight unit with O-rings that have already been used in service. DANGER Adequate PPE should be warn when assembling or disassembling the Hy- Sight unit, this includes but not limited to eye protection and cut proof gloves. 3.2. Assembly Assembly should only be carried out by trained personnel who are familiar with this IOM manual. The following steps should be taken: a) Install one of the new centralizing O-rings over the glass cylinder, so that it sits approximately 1 away from the one end of the cylinder. b) Place the new sealing O-rings into the head connections (one in each), ensuring they sit snuggly into the precision machined groove. 5

c) Now add lubricant** to the visible surfaces of both sealing O-rings & the external threads of the head connections. d) Place the glass cylinder into one of the head connections, centralizing O-Ring end first. e) Roll the centralising O-Ring down to sit between the precision groove on the head connection and the glass cylinder. f) Carefully place the body over the top of the glass cylinder, slipping it down and over until it engages with the threaded head connection. g) Loosely thread the body onto the head connection. Do not tighten the two components together, a small gap between body & head connection should be visible. h) Fit the final centralizing O-ring into the groove in outstanding head connection. i) Now add lubricant** to the visible surfaces of the centralizing O-ring. j) Slip the head connection complete with installed O-Rings over the glass cylinder and tighten loosely. k) Tighten both head connections until they a butted up against the body. ** Ensure the lubricant used is not harmful to either the O-rings material or the end users process. DANGER Adequate PPE should be warn when assembling or disassembling the Hy- Sight unit, this includes but not limited to eye protection and cut proof gloves. 6