DO NOT PRINT THIS PAGE

Similar documents
Pressure Automated Calibration Equipment

Additel 780 Series Pressure Controller

PACE Modular Pressure Controller

The PACE6000. Modular Pressure Controller/Indicator. GE Measurement & Control Solutions. Features

PACE1000 Precision Pressure Indicator

High-speed pressure sensor Model CPT6140

Additel 761 Automated Pressure Calibrators

Additel 780 Series Pressure Controller

Additel 761 Automated Pressure Calibrators Selection Guide

Additel 761 Automated Pressure Calibrators

UNIK 5600/5700 Marine Certified Pressure Sensing Platform

Additel 761 Automated Pressure Calibrators Selection Guide

Pneumatic High-Speed Pressure Controller Model CPC3000

Additel 761 Automated Pressure Calibrators

Additel 780 Series Pressure Controller

DPC-30 DPC-100. Reference Manual

Series 7250 Ruska High-Speed Digital Pressure Controller. GE Sensing. Features

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

Pneumatic high-pressure controller Model CPC7000

DM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

UNIK 5600/5700. Marine Certified Pressure Sensing Platform. High Quality. Features. Bespoke as Standard. Expertise. bhge.com

Pneumatic high-pressure controller Model CPC7000

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05

Do Not Print This Page

Series Ruska Digital Pressure Indicator. GE Sensing & Inspection Technologies. Features

628 Differential Pressure Decay Leak Tester

陕西创威科技有限公司. Shaanxi Creat Wit Technology Co., Ltd. Precision pressure calibrator-cwy300 Operating Manual

Additel. Overvie. vacuum. Standalone. to 200 bar. products for. to use. The establishes. the future. Calibration Experts EN ISO / IEC

ADT 761 Automated Pressure Calibrator

Pressure Technical Information

Precision digital pressure gauge Model CPG1000

Datasheet TM40. HUBER INSTRUMENTE AG, Grellingerstrasse 23, CH-4208 Nunningen. All rights reserved Paige 1 / 5 Datasheet_TM40_

PPC4E Pressure Controller/Calibrator Superior rangeability and reliability

RPS/DPS High Accuracy Resonant Pressure Sensor. GE Oil & Gas. Features:

Hand-held pressure calibrator with integrated pump Model CPH6600

ADT. Series. oller. Overvie. vacuum Removable. Standalone. Easy-to-use. products for. to use. The establishes

Pressure transmitter PASCAL Ci4

Cecomp. Electronics. Test. Measure. Monitor. Transmit. Alarm. Cecomp High Perfor. formance Digital Pressur

Precision pressure sensor Basic version Model CPT6020

7250 Sys. Ruska Multi-Range Pressure Calibration System. GE Sensing & Inspection Technologies. Features. Applications

RTX 1000H Series. Versatile Transmitters for a World of Pressure. GE Measurement & Control. Features

MODEL 6500 Rev. E USER'S MANUAL

Digitale manometers. TYPE: ETD-01, klasse 0.5. Specificaties HOOFDSTUK 6

Lab 1c Isentropic Blow-down Process and Discharge Coefficient

PTG100 Precision Test Gauge

Stratomaster Smart Single

Industrial pressure controller Model CPC4000

PRESSURE MEASUREMENT DPI 515 PRECISION PRESSURE CONTROLLER/CALIBRATOR OPERATOR'S MANUAL K245. K245 Issue No.2

PS-525 Pitot-Static/Air Data Tester. OPERATION AND MAINTENANCE MANUAL For Models PS-525 and PS-525A

Operating Instructions Part No

[Instruments for vacuum measurement, checking and adjustment] 3

Pressure calibration. 20

MODEL 6500 Rev. F4 USER'S MANUAL LAVERSAB INC., 505 GILLINGHAM LANE SUGAR LAND TX, (281) FAX: (281)

P3000 Series. Pneumatic Deadweight Testers Model P3000. Technical Data. Features

MASS FLOW SYSTEMS MASS FLOW MEASURING, CONTROLLING AND BLENDING SYSTEMS

DIGITAL AUTOMATIC TYRE INFLATOR

Operating Instructions Part No

Digital pressure gauges

High-performance submersible pressure transmitter For level measurement Model LH-10

Industrial pressure controller Model CPC4000

Pneumator. Testo Industrial Services More assurance, better service. Pressure calibrator and measuring instrument.

Pressure measurement explained

AMETEK JOFRA APC Advanced Pressure Calibrator

PS-525 Pitot-Static/Air Data Tester. OPERATION AND MAINTENANCE MANUAL For Models PS-525 and PS-525A

MODEL 6600 Rev. B4 USER'S MANUAL LAVERSAB INC., 505 GILLINGHAM LANE. SUGAR LAND TX (281) FAX: (281)

Digital deadweight tester Model CPD8500

BIOGAS COMBUSTION PLANT MAINTENANCE MANUAL

Pressure & Temperature Calibration Equipment

Digital Pressure Gauge Main features: Data Sheet: BIT02B.417.R6.EN COVER on request

Short manual testo

High-performance submersible pressure transmitter For level measurement Model LH-10

1811G/H PITOT-STATIC TEST SET

Modular pressure controller Model CPC6050

JOLLY2. Installation user s manual. 6 different operating modes selectable. version 3.3. DATA TO BE FILLED OUT BY THE INSTALLER (Page 1)

How to specify a product. Process Sensors and Mechanical Instruments

Pressure transmitters EMP 2

Digital dead-weight tester Model CPD8500

Bubble Tube Installations

Differential Pressure Transmiter

Pegas 4000 MF Gas Mixer InstructionManual Columbus Instruments

Instruction Manual. PLT Series. 1. General Specification. 2. Installation. 3. Wiring. 4. Function. 5. Setting & Calibration

2600T Series Pressure Transmitter Models 264DC Differential and 264HC Gage Level Transmitters. Kent-Taylor

PTS 2000Version User s Manual. Operators Manual

Additel761 Series Firmware Updates

Druck RTX 1000H series

PX3005. Rangeable Industrial Pressure Transmitter M-5721/1018


Data Sheet. Pressure transducers and instrumentation

DPI 610/615 Series. Druck Portable. Pressure Calibrators. GE Sensing. Features. Setting the Standard for Portable. Pressure Calibrators

P3000 Series. Pneumatic Deadweight Testers Model P3000. Technical Data. Features

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI

Programmable pressure and temperature transmitters PTM/RS485

GP1 & GP2. Electropneumatic Regulators FOR PRESSURE CONTROL TO 1,000 PSI

User Manual Pressure Calibration System C and Hydraulic Pressure Pump Models T-620/T-620H Copyright 2008 AMETEK Denmark A/S

Programmable pressure and temperature transmitters PTM/RS485

Copyright 2004 by the Thomas G. Faria Corporation, Uncasville CT No part of this publication may by reproduced in any form, in an electronic

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition

1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure

M2110P SMART PRESSURE GAUGE USER S MANUAL

Transcription:

Pressure measurement for research & industry Druck Limited Fir Tree Lane Groby Leicester LE6 0FH England Tel: 0116 231 7100 Pressure Automated Calibration Equipment Calibration manual K0450 Druck Limited 2010 This document is the property of Druck Limited and may not, either in part or whole, be copied or otherwise reproduced, communicated in any way to third parties, nor stored in any data processing system, without the express written authority of Druck Limited. Page 1 of 26 K0450 Issue 2 DO NOT PRINT THIS PAGE

Amendment Record Iss No Date C/N No Originator Typed Workflow No. Amendments 1 21/04/10 N/A Robert Lee Robert Lee 144693 New document 2 12/10/10 25591 Robert Lee Robert Lee 152835 Add section 2, PACE1000 details Approvals Engineering P BRADLEY Marketing M SINGLETON Technical Communications R LEE Page 2 of 26 K0450 Issue 2 DO NOT PRINT THIS PAGE

Print Instructions Page size 180 x 230 mm. Note: this document is normally published electronically and shipped on UD-0001. THIS HARDCOPY IS NOT TO BE USED AS CAMERA COPY. Page 3 of 26 K0450 Issue 2 DO NOT PRINT THIS PAGE

Page 4 of 26 K0450 Issue 2 DO NOT PRINT THIS PAGE

GE Measurement & Control Solutions Pressure Automated Calibration Equipment Calibration manual K0450 PACE5000 PACE6000 PACE Indicators g

The General Electric Company. All rights reserved

Introduction This technical manual provides calibration instructions for the PACE Pressure Controllers and Indicators. The features shown and described in this manual may not be available on some models. Safety The manufacturer has designed this equipment to be safe when operated using the procedures detailed in this manual. Do not use this equipment for any other purpose than that stated. This publication contains operating and safety instructions that must be followed to ensure safe operation and to maintain the equipment in a safe condition. The safety instructions are either warnings or cautions issued to protect the user and the equipment from injury or damage. Use suitably qualified * calibration technicians and good engineering practice for all procedures in this publication. Pressure Do not apply pressures greater than the maximum working pressure to the equipment. It is the responsibility of the calibration technician to apply pressures within the published pressure range and to only use external pressure equipment with correctly rated fittings and components. Toxic Materials There are no known toxic materials used in construction of this equipment. Maintenance The equipment must be correctly maintained, the manufacturer s procedures should be carried out by authorized service agents or the manufacturer s service departments. Technical Advice For technical advice contact the manufacturer. * A qualified calibration technician must have the necessary technical knowledge, documentation, special calibration/test equipment and tools to carry out the required work on this equipment. K0450 Issue No. 2 i

Abbreviations The following abbreviations are used in this manual; the abbreviations are the same in the singular and plural. abs Absolute a.c. Alternating current ALT Altitude BSP British pipe thread CAS Calculated airspeed CSK Countersunk d.c. Direct current DPI Digital Pressure Instrument e.g. For example etc. And so on Fig. Figure ft Foot g Gauge Hg Mercury HTS High tensile steel Hz Hertz IAS Indicated airspeed i.e. That is IEC International Electrotechnical Commission IEEE 488 Institute of Electrical and Electronic Engineers standard 488 data in Inch kg Kilogram kts/kn knot LCD Liquid crystal display m Metre ma Milliampere max Maximum mbar Millibar min Minute or minimum mm Millimetre mv Millivolts MWP Maximum working pressure No. Number NPT National Pipe Thread PACE Pressure Automated Calibration Equipment Para. Paragraph PDCR Pressure transducer PED Pressure Equipment Directive psi Pounds per square inch PTX Pressue transmitter K0450 Issue No. 2 ii

ROC Rate of Climb RS232 Serial communications data standard RtCAS Rate of calculated airspeed RtMach Rate of Mach SCPI Standard Commands for Programmable Instruments UUT Unit under test V Volts VFC Volts-free contact +ve Positive -ve Negative C Degrees Celsius Associated publications K0447 PACE5000/6000 User Guide and Safety Instructions K0467 PACE1000 Indicator User Guide and Safety Instructions K0443 PACE5000/6000 Controller User Manual K0470 PACE1000 Indicator User Manual K0476 Pressure Control Module User Guide and Safety Instructions K0472 SCPI Communications Manual K0469 Heritage Communications Manual - Instrument Emulation Symbols The equipment contains the following symbols to identify hazards. This equipment meets the requirements of all relevant European safety directives. The equipment carries the CE mark. This symbol, on the instrument, indicates that the user should refer to the user manual. This symbol, on the instrument, indicates do not throw-away in domestic bin, hazardous material, dispose correctly in accordance with local regulations. K0450 Issue No. 2 iii

Pressure units and conversion factors Pressure units Factor (hpa) Pressure units Factor (hpa) mbar 1.0 cmh 2 O @ 20 C 0.978903642 bar 1000.0 mh 2 O @ 20 C 97.8903642 Pa (N/m 2 ) 0.01 kg/m 2 0.0980665 hpa 1.0 kg/cm 2 980.665 kpa 10.0 torr 1.333223684 MPa 10000.0 atm 1013.25 mmhg @ 0 C 1.333223874 psi 68.94757293 cmhg @ 0 C 13.33223874 lb/ft 2 0.4788025898 mhg @ 0 C 1333.223874 inh 2 O @ 4 C 2.4908891 inhg @ 0 C 33.86388640341 inh 2 O @ 20 C 2.486413 mmh 2 O @ 4 C 0.0980665 inh 2 0 @ 60 F 2.487641558 cmh 2 O @ 4 C 0.980665 fth 2 O @ 4 C 29.8906692 mh 2 O @ 4 C 98.0665 fth 2 O @ 20 C 29.836983 mmh 2 O @ 20 C 0.097890364 fth 2 0 @ 60 F 29.8516987 Unit Conversion To convert FROM pressure VALUE 1 in pressure UNITS 1 TO pressure VALUE 2 in pressure UNITS 2, calculate as follows: VALUE 2 = VALUE 1 x FACTOR 1 FACTOR 2 Note: The PACE instrument contains selectable pressure units and user defined units. Use the conversion factors to calculate a user defined unit from the table above. Refer to the data sheets for the list of selectable pressure units. K0450 Issue No. 2 iv

CONTENTS Title Page CALIBRATION PROCEDURES for PACE CONTROLLERS 1-1 Introduction... 1-1 Calibration Status... 1-1 Preliminary Operations... 1-1 Connecting the Calibrator... 1-2 Calibration Check (All Ranges)... 1-3 Calibration Adjustment... 1-5 CALIBRATION PROCEDURES for PACE INDICATORS 2-1 Introduction... 2-1 Calibration Status... 2-1 Preliminary Operations... 2-1 Connecting the Calibrator... 2-2 Calibration Check (All Ranges)... 2-3 Calibration Adjustment... 2-5 K0450 Issue No. 2 v

intentionally left blank K0450 Issue No. 2 vi

PACE Series Calibration Manual 1 Calibration Procedures for PACE Controllers Introduction The PACE controller incorporates a calibration facility; for the PACE to stay accurate, a calibration check should be carried out at chosen intervals. If the accuracy of the PACE is not within the permissible deviation, carry out a calibration adjustment. Calibration Status Using the Measured Pressure/Instrument Status menu, the calibration status of the calibrator can be displayed on the front panel screen. The status menu includes Calibration History which gives a list of dates of the stored calibration corrections. Note: The Date and Time must be set correctly using the Measured Pressure/Global Set-up/ Calibration menu. Calibration Equipment The original GE Calibration Certificate shows the measurement uncertainty of the original calibration standard. Preliminary Operations Review and become familiar with the whole procedure before beginning a calibration process. Allow at least one hour for the PACE to thermally stabilize in a thermally stable environment after switching on and before calibration. Before starting a calibration procedure: Carry out a leak test as detailed in PACE user manual K0443. Notes on calibration The pressure standard output port and the reference level must be at the correct level or use heightcorrected applied pressure. To prevent applied calibration pressure back feed, fit blanking plugs to both positive and negative supply ports on the manifold. Make sure that before starting a calibration procedure both pressures on gauge measurements are equalised and stable. Set the PACE units of pressure to one of the required units for calibration. K0450 Issue No. 2 1-1

1 PACE Controllers Connecting the Calibrator Connect the calibrator for each pressure range as follows: Connect the output of the pressure standard to the PACE module output port. PACE Pressure Standard rear view Gauge Reference If the pressure standard has a reference connection, then connect this to the PACE reference port on the module manifold. Otherwise the calibrator reference port should be open to atmosphere. PACE Pressure Standard rear view module 2 reference port open to atmosphere or to reference port of the pressure standard. Absolute Range Note The PACE adds the barometric reading to a gauge range to produce an absolute range. Calibration Check (All Ranges) Procedure K0450 Issue No. 2 1-2

PACE Series Calibration Manual Set the calibrator to measure mode: 1 Connect calibration standard for the pressure range to be checked. 2 Press Task and select Basic. 3 With the pressure standard connected to the correct pressure port, select Measured Pressure and press Range to select the gauge pressure range to be checked. 4 Barometric pressure can be displayed in the status area. Gauge ranges should be zeroed as follows: 1 Press Measured Pressure/Zero to zero the selected range. 2 On completion of the zero operation, the display shows Zero completed successfully. 3 Adjust calibration pressure to the first pressure value. 4 Compare the pressure value on the calibration standard to the value displayed and record the difference. 5 Repeat (3) and (5) for each pressure. 6 If the recorded difference exceeds the permissible deviation for the selected range, the calibrator requires a calibration adjustment for that range. Refer to sales data sheets SDS0001 and SDS0008 for permissable deviation. 7 Select the next pressure range for a calibration check. 8 After completing all calibration checks, adjust calibration standard to atmospheric pressure. 9 Disconnect calibration standard from the output. If no further calibration is required, switch off the PACE. K0450 Issue No. 2 1-3

1 PACE Controllers K0450 Issue No. 2 1-4

PACE Series Calibration Manual Calibration Adjustment To adjust a calibration range of the calibrator, proceed as follows. 1 Connect the calibrator for the range to be adjusted, as detailed in Calibration Check. Note The calibration adjustments must be carried out in any order. 2 Select Measured Pressure/Global Set-up/Calibration, enter the Calibration PIN (4321). 3 Select Sensor Correction. 4 Select the pressure range to be corrected. 5 Select New Calibration. 6 The display shows the first value to be set on the pressure standard and to press OK when the applied pressure is stable. Use the numeric keys to enter the precise applied pressure. Note The display also shows throughout this procedure the message Calibrating and the selected pressure range. 7 Select Accept to store the first value and the display goes to the next pressure value to be set. 8 Select Repeat to re-apply the same pressure and Quit Calibration to exit the calibration of this pressure range. 9 Repeat steps (5) to (7) for the next value. 10 Carry out a calibration check to verify this procedure. 11 After completing the calibration procedures, adjust the calibration standard to atmospheric pressure. Disconnect calibration standard from the PACE. K0450 Issue No. 2 1-5

1 PACE Controllers K0450 Issue No. 2 1-6

PACE Series Calibration Manual 2 Calibration Procedures for PACE Indicators Introduction The PACE indicator incorporates a calibration facility; for the PACE to stay accurate, a calibration check should be carried out at chosen intervals. If the accuracy of the PACE is not within the permissible deviation, carry out a calibration adjustment. Calibration Status Using the Measured Pressure/Instrument Status menu, the sensor calibration status of the indicator can be displayed on the front panel screen. The status menu includes Calibration History which gives a list of dates of the stored calibration corrections. Note: The Date and Time must be set correctly using the Measured Pressure/Global Set-up/ Calibration menu. Calibration Equipment The original GE Calibration Certificate shows the measurement uncertainty of the original calibration standard. Preliminary Operations Review and become familiar with the whole procedure before beginning a calibration process. Allow at least one hour for the PACE to thermally stabilize in a thermally stable environment after switching on and before calibration. Before starting a calibration procedure: Carry out a leak test as detailed in PACE Indicator user manual K0470. Notes on calibration The pressure standard output port and the indicator reference level must be at the correct level or use height-corrected applied pressure. Make sure that before starting a calibration procedure both pressures on gauge measurements are equalised and stable. Set the PACE units of pressure to one of the required units for calibration. K0450 Issue No. 2 2-1

2 PACE Indicators Connecting the Indicator Connect the indicator for each pressure range as follows: Connect the output of the pressure standard to the indicator port. PACE Indicator Pressure Standard rear view Gauge Reference If the pressure standard has a reference connection, then connect this to the indicator reference port. Otherwise the indicator reference port should be open to atmosphere. PACE Indicator Pressure Standard rear view indicator reference port open to atmosphere or to reference port of the pressure standard. Absolute Range Note The indicator adds the barometric reading to a gauge range to produce an absolute range. K0450 Issue No. 2 2-2

PACE Series Calibration Manual Calibration Check (All Ranges) Procedure Set the indicator to measure mode: 1 Connect calibration standard for the pressure range to be checked. 2 Press Task and select Basic. 3 With the pressure standard connected to the correct pressure port, select Measured Pressure and press Range to select the gauge pressure range to be checked. 4 Barometric pressure can be displayed in the status area. Gauge ranges should be zeroed as follows: 1 Press Measure Pressure/Zero to zero the selected range or press the zero button on the screen. 2 On completion of the zero operation, the display shows Zero completed successfully. 3 Adjust calibration pressure to the first pressure value. 4 Compare the pressure value on the calibration standard to the value displayed and record the difference. 5 Repeat (3) and (5) for each pressure. 6 If the recorded difference exceeds the permissible deviation for the selected range, the indicator requires a calibration adjustment for that range. Refer to the sales data sheet for permissable deviation. 7 Select the next pressure range for a calibration check. 8 After completing all calibration checks, adjust calibration standard to atmospheric pressure. 9 Disconnect calibration standard from the output. If no further calibration is required, switch off the PACE indicator. K0450 Issue No. 2 2-3

2 PACE Indicators K0450 Issue No. 2 2-4

PACE Series Calibration Manual Calibration Adjustment To adjust a calibration range of the indicator, proceed as follows. 1 Connect the indicator for the range to be adjusted, as detailed in Calibration Check. Note The calibration adjustments must be carried out in any order. 2 Select Measured Pressure/Global Set-up/Calibration, enter the Calibration PIN (4321). 3 Select Sensor Correction. 4 Select the pressure range to be corrected. 5 Select New Calibration. 6 The display shows the first value to be set on the pressure standard and to press OK when the applied pressure is stable. Use the numeric keys to enter the precise applied pressure. Note The display also shows throughout this procedure the message Calibrating and the selected pressure range. 7 Select Accept to store the first value and the display goes to the next pressure value to be set. 8 Select Repeat to re-apply the same pressure and Quit Calibration to exit the calibration of this pressure range. 9 Repeat steps (5) to (7) for the next value. 10 Carry out a calibration check to verify this procedure. 11 After completing the calibration procedures, adjust the calibration standard to atmospheric pressure. Disconnect calibration standard from the PACE indicator. K0450 Issue No. 2 2-5

2 PACE Indicators K0450 Issue No. 2 2-6

The General Electric Company. All rights reserved