Bermad Model:

Similar documents
Model 420-HY Pressure Regulating Hydrant Valve

INSTALLATION OPERATION MAINTENANCE

Model: 720-UL INSTALLATION OPERATION MAINTENANCE. Bermad Pressure Reducing Valve IOM. Model: FP -720-UL Sizes: 2"-12" BERMAD. Application Engineering

Bermad Pressure Reducing. Model: 42T

Installation Operation Maintenance. Bermad Level Control Valve with Modulating Horizontal Float Pilot valve One Way Flow IOM.

WW-730. Pressure Sustaining/Relief Control Valve

Model: 43T. Bermad Pressure Relief Valve

WW-720. Pressure Reducing Control Valve

WW-720. Pressure Reducing Control Valve

DESIGN DATA A WET PIPE BLADDER TANK FOAM/WATER SYSTEM WITH HYDRAULICALLY ACTUATED DELUGE CONCENTRATE CONTROL VALVE

I T T Pressure Reducing Valve WARNING INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

TECHNICAL DATA. than the water inlet pressure to the concentrate

DESIGN DATA OBSOLETE. C. Inspections - It is imperative that the system be inspected and tested on a regular basis. See Inspection

BERMAD Waterworks. Level Control Valve with Altitude Pilot. 700 Series. Model X. Features and Benefits. Major Additional Features

TECHNICAL DATA. Page 1 of 8. model f /2 (dn40) & 2 (dn50)

TECHNICAL DATA PILOT PRESSURE REGULATED DELUGE SYSTEM CONTROLLED BY PNEUMATIC RELEASE. 1. DESCRIPTION (Refer to Figures 1, 2 or 3.

TECHNICAL DATA Q= C. Table 1 - Specifications

TECHNICAL DATA. Trimpac 251a. Spetember 16, 2013

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B

TECHNICAL DATA. Trimpac 244a. September 16, 2013

TECHNICAL DATA. Page 1 of 12

TECHNICAL DATA. Inlet Type Outlet Type OBSOLETE. 4. TECHNICAL DATA Approvals:

TECHNICAL DATA DELUGE VALVE, MODEL F-1 STRAIGHT THROUGH STYLE

Pressure Regulating Valves. Models 44, 77 & 68 PS\ UL. Pressure Relief Valve. Dorot Fire Protection Division. Certification & compliance by design

TECHNICAL DATA ACCELERATOR MODEL E-1

TECHNICAL DATA CAUTION

TECHNICAL DATA PILOT PRESSURE REGULATED DELUGE SYSTEM CONTROLLED BY ELECTRIC RELEASE 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3.

TECHNICAL DATA. Low-Flow Foam Preaction System with Hydraulically Actuated Concentrate Control Valve.

TECHNICAL DATA SINGLE INTERLOCKED PREACTION SYSTEM WITH PNEUMATIC RELEASE

TECHNICAL DATA. Pressure Regulation 531a. April 24, 2009

TECHNICAL DATA. Table 1 - Specifications

TECHNICAL DATA. Dry 132a. October 1, 2008

TECHNICAL DATA. System water supply pressure enters the priming chamber of the deluge valve (A.1) through the 1/4 (8 mm) priming line, which

Wet pipe low flow foam/water system

FM Approved - Automatic Water Control Valve as standard deluge valve. No formal approval available for coating. Foam Concentrate

Reduce pressure zone device suitable for high and medium hazard rated applications BSP screwed connections

TECHNICAL DATA CAUTION

Combination Air Valve

TECHNICAL DATA. the Viking Pilot Pressure Regulating Valve 1 Model A-1 Speed Control Assembly: OBSOLETE. the Viking Speed Control Assembly 1

Anti-flood device Model B-1

BEFORE SALES AFTER SALES

OBSOLETE DESIGN DATA. Foam 301a. February 9, 1998

TECHNICAL DATA ANTI-FLOOD DEVICE MODEL B-1 1. DESCRIPTION

Combination Air Valve Model

Instructions for Installation, Operation, Care and Maintenance

Installation and operation Manual. Bermad Surge Anticipation Valve. Model No 435

Reduce pressure zone device suitable for high and medium hazard rated applications Flanged end connections

VALVCHEQ BACKFLOW PREVENTERS FIGURE RP03

APCO ARV CLEAN WATER AIR RELEASE VALVES. Model 50A

End Connection. Thread x Thread N/A N/A N/A N/A Flange x Flange N/A

TECHNICAL DATA. Trimpac 257a. September 16, 2013

FM Approved - Automatic Water Control Valve as standard deluge valve. No formal approval available for coating. Foam Concentrate

1800C and 1800C-HC Series Service Regulators

OBSOLETE. Wet pipe low flow manifold system

OWNER S TECHNICAL MANUAL

D05T Compact Design Pressure Regulating Valves

GENERAL DESCRIPTION MODEL RCW DRY SYSTEM CONFIGURATION. Technical Support Airpark Dr. Standish, MI 48658

1200B2 Series Service Regulators. Instruction Manual

VALVCHEQ BACKFLOW PREVENTERS FIGURE RP03

TECHNICAL DATA. Trimpac 256a. October 31, 2013

Fisher DVI Desuperheater Venturi Inline

Installation, Operation, and Maintenance Manual

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

Installation, Operation, and Maintenance Manual

Model B-1 Pipe Line Strainer 3, 4, 6 & 8 Inch (DN80, DN100, DN150 & DN200) 175 psi (12,1 bar) General Description. Technical Data

TECHNICAL DATA. Deluge Valves 218a. November 30, 2007 DELUGE VALVE MODEL F-1 STRAIGHT THROUGH STYLE 2-1/2 (DN65) - 8 (DN200)

M45 ISO Ball Valve DN25 to 150 Installation and Maintenance Instructions

TECHNICAL DATA OBSOLETE

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Deluge Valves 211a. November 30, 2007 DELUGE VALVE MODEL E-1 ANGLE STYLE 3 (DN80), 4 (DN100) & 6 (DN150)

FUNDAMENTALS OF PRESSURE REGULATORS ROBERT BENNETT MANAGER OF TRAINING ELSTER AMERICAN METER

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

Description. Functions. Technical data. Applications. Tests. On-Off 2 levels float control valve, closing at high level and opening at low level.

Installation, Operation and Maintenance Manual for Back Pressure Regulator

RHPS Series RD(H)F40 User Manual. Read the complete manual before installing and using the regulator.

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

Type S301 & S302 Gas Regulators INTRODUCTION INSTALLATION. Scope of Manual. Description. Specifications. Type S301 and S302. Instruction Manual

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

Installation Instructions

SCA Series Inverted Bucket Steam Traps

Pressure Reducing Valve for Steam Type 2333 A

BERMAD Fire Protection Hydraulic Control Valves

TECHNICAL DATA OBSOLETE

Manual Actuated Boiler Blowdown Valves

Halsey Taylor Owners Manual STOP!

BUTTERFLY VALVES Series 800

Halsey Taylor Owners Manual 4410 Freeze Resistant Tubular Fountain STOP!

TECHNICAL DATA. Q = C v P S

Installation Troubleshooting Maintenance Instructions Installation / Start-up

Bladder Tank Installation & System Design Information

RD(H)20/25 Pressure-Reducing Regulator User Manual

D05 Pressure Regulating Valves

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

DS05C,D,G Dial Set Pressure Regulating Valves

FOAM TANK (1/2) DATA SHEET

TECHNICAL DATA. Q= Cv S

627 Series Pressure Reducing Regulators

SUBMITTAL NOTES PROJECT: Ross Model 50RWR-A Pilot Operated Surge Relief Valve with Hydraulic Anticipation. Size: inch / mm

Pipe Thread Connection 1/2 inch NPT. Friction Loss Refer to Figure 3

Transcription:

Bermad Model: 405-02 Manually Operated Hydraulic Valve INSTALLATION OPERATION MAINTENANCE Application Engineering BERMAD

1. Safety First BERMAD believes that the safety of personnel working with and around our equipment is the most important consideration. Please read all safety information below and from any other relevant source before attempting to perform any maintenance function. Comply with all approved and established precautions for working with your type of equipment and/or environment. Authorized personnel should perform all maintenance tasks. Prior to performing a procedure, read it through to the end and understand it. If anything is not clear, ask the appropriate authority. When performing a procedure, follow the steps in succession without omission. 2. Description BERMAD's 405-02 Fire Protection Control Valves are Elastomeric- type globe valves that are rollingdiaphragm actuated, with an integral solid, resilient seal. These automatic control valves are designed for vertical or horizontal installation and are available in diameter sizes from 2 to 12 (DN50 t0 DN300). The BERMAD 405-02 valves are used for water flow control for a Monitor, on-off systems or Water/Foam systems where speed control opening is required. These valves are manufactured from materials suitable for seawater and freshwater/ foam solution applications. The 400 Water Control Valve is held closed by system water pressure trapped in the control chamber. When the releasing system operates, pressure is released from the control chamber, and the seal disc opens to allow water to flow into the system. The design of the 400 valve body includes a single, full bore seat with unobstructed flow path, free of any inline ribs, supporting cage, or shafts. The unique hydro-dynamic globe design provides high flow capabilities with minimum head loss. The cover is removable via four fastening bolts (up to 10 ) for quick in-line inspection and servicing. The internal design of the 400 valve is based on innovative technology using advanced rubber-based materials to achieve a solid, one-piece, elastomeric assembly including flexible fiber reinforced diaphragm, vulcanized with a rugged radial seal disk, and together providing resilient, drip-tight sealing. The elastomeric assembly is carefully balanced and peripherally supported to avoid tension and protect the elastomer, resulting in long-life, controlled actuation, even under harsh conditions. The elastomeric assembly can be easily removed from the valve body with no need for disassembling the valve from the line. 3. Approvals BERMAD's 405-02 Valve is Lloyd s Register and ABS approved when installed with specific components & accessories. Refer to the current directory. Consult the manufacturer for any component 4. Installation Proper operation of the Bermad Valves depends upon their trim being installed in accordance with the appropriate Trim configuration. Warning: The Water Control valve and trim must be installed only in areas where they will not be subject to freezing

Installation Instructions 4.1 Allow enough room around the valve assembly for any adjustments and future maintenance. 4.2 Before the valve is installed, flush the pipeline to remove any dirt, scale, debris, etc. Not flushing the line may Result in the valve s becoming inoperable. 4.3 Install the valve in the pipeline so that the valve flow arrow appearing on the body casting is pointing in the desired direction. Ensure that the valve is positioned so that the cover can be easily removed for future maintenance. 4.4 Ensure that the Control Trim is mounted properly and all other components are positioned correctly as per illustration. 4.5 After installation in the main line, carefully inspect/correct any damaged accessories, piping, tubing, or fittings. Ensure that there are no leaks. 4.6 Install the components comprising the Water Control Trim Package in their proper positions in compliance with All instructions, drawings, and technical specifications describing the BERMAD Fire protection Valve, according to the relevant illustration. 4.7 All additional accessories, although not packed together with the BERMAD Water Control Valve, must be installed as shown in the relevant P&ID and other illustrations. 5. Equivalent Length Deluge Valve Equivalent Length Value (Steel Pipe), for use in hydraulically calculated systems Valve Size Equivalent Length Value Meter (Ft) 2 9.1 (30) of 2 pipe 2½ 12.1 (40) of 2½ pipe 3 13.7 (45) of 3 pipe 4 14 (46) of 4 pipe 6 27.4 (90) of 6 pipe 8 45.7 (150) of 8 pipe 6. Placing in Service/Resetting the System The Water Control valve and the control trim shall be placed in service in accordance to the most recent IOM procedures for the specific model. After all relevant instructions are performed, slowly open the supply-isolating valve and check that no water flows into the system. The system is now operational and in stand-by mode.

7. Removing the system Removing the System from Service Warning: When taking the fire protection system out of service, a fire patrol should be established in the system area. If automatic fire alarm signaling equipment is utilized, the proper authority should be notified that the system is being removed from service. The insuring body and owner s representative should also be notified when the system is being taken out of service 7.1 Shut off the main supply-isolating valve. 7.2 Close the priming line valve to the Bermad valve control chamber. 7.3 Open all drain valves. 7.4 Release the water pressure from the control chamber of the Water Control valve by pulling the manual emergency release. 7.5 Place "Fire Protection System out of Service" signs in the area protected by the system. 8. Operation The Bermad model FP-405-02 is a simple designed, manually operated on/off valve equipped with opening speed control. This valve is particularly suited for industrial hydrants. This valve is equipped with a restriction orifice to restrict the opening time of the valve. The BERMAD 400 Water Control Valve (assembled with specific trim) prevents water from entering system piping until required. The Water Control valve is kept closed by pressure applied to the control chamber through a restricted priming line. In the SET position, the water pressure supplied through the priming line is trapped in the control chamber of the Water Control valve by a check valve, and by the normally closed release device. The pressure trapped in the control chamber of the Water Control valve presses the valve seal disc down, thereby sealing the valve and keeping the system piping dry. Under conditions of FIRE, when the pressure is released from the control chamber by the opening of the automatic releasing device or by manual release, the Water Control valve opens and allows the inlet supply water to flow through the valve and into the system piping and alarm devices. Valve Closed (Set Position) Line pressure applied to the control chamber of the valve creates a superior force that moves the valve to the closed position and provides drip tight sealing. Valve Open (Operating Conditions) Releasing the pressure from the control chamber to atmosphere or some other lower pressure zone causes the line pressure acting on the seal disc to move the valve to the open position..

9. Figure 2: Operation Drawing 10. Maintenance and Inspection Test Warning: Do not turn off the water supply to make repairs without placing a roving fire patrol in the area covered by the system. The patrol should continue until the system is back in service. 10.1 Prior to turning off any valves or activating any alarms, notify local security guards and the central alarm station,if used, to avoid signaling a false alarm. 10.2 The Water Control valve and the control trim shall be maintained with accordance to the most recent IOM procedures for the specific model. A periodic test schedule should be established also with accordance to the site conditions and owner regulations. 10.3 Take all additional measures as required by NFPA-25 standard for the inspection, testing, and maintenance of water-based fire protection systems. 10.4 The system should be checked weekly for Normal Conditions. 10.5 Clean the priming strainer prior to any resetting of the Water Control valve. 10.6 The Water Control valve must be activated at full flow at least annually. Take all necessary precautions to drain water and prevent damage in the area protected by the system. 10.7 After about five years of operation, replacement of the diaphragm assembly is recommended. Remove the Cover, clean the valve body from sediments, clean the control tubing entry holes, and install a new diaphragm assembly. 11. Spare Parts 11.1 The Diaphragm Assembly is the only spare part needed for the main Water Control valve, It is not recommended to store spare rubber parts for long periods (rubber in improper storage conditions can harden and crack). 11.2 Contact your Bermad representative and order new rubber parts when required.

12. Troubleshooting SYMPTOM PROBABLE CAUSE REMEDY Valve fails to open Valve fails to hold set static outlet pressure Insufficient inlet pressure. Clogged restriction orifice Indicating valves closed. Filter screen (4) blocked. Debris trapped in main valve. Check/create inlet pressure. Open and clean orifice assembly. Open. Remove filters cap and screen to clean. Remove and inspect actuator assembly. Check seat and disc seal. Diaphragm in main valve is leaking. Caution: This test will cause the valve to go fully open. Close downstream indicating valve or omit this test if this may cause damage. Test for leakage. Close indicating valves and remove the plug in the main valve cover. If a continuous flow exists, the diaphragm is damaged or loose. 13. Difficulty in Performance Where difficulty in performance is experienced, the manufacturer or his authorized representative should be contacted if any field adjustment is to be made.