ARCHITECTURAL GUIDELINES 1000 S

Similar documents
ARCHITECT GUIDELINES 1000 T

ARCHITECTURAL GUIDELINES FOUR-PIECE COMMERCIAL

ARCHITECTURAL GUIDELINES ONE-PIECE COMMERCIAL

ARCHITECTURAL GUIDELINES FOUR-PIECE RESIDENTIAL

ARCHITECT INSTALLATION GUIDELINES FOR RESIDENTIAL TRITON INSTALLATIONS

Blue Whale Spa :- Site Preparation and Delivery

Life Smart Spas Frequently Asked Questions

Swim Spa Pre-delivery Guide

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

ECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION

SPA WORLD. Pre- delivery Guide

PRE-PURCHASE DECISIONS...1 BEFORE DELIVERY...1

ETL listed for installations within 5 ft. (1.5M) of outer edge of water

Life Smart Spas Frequently Asked Questions LS600DX

Step-by-Step Planning Guide

D E L U X E S E R I E S. Your Hot Tub Pre-Delivery Guide D E L U X E

Swimming Pool Requirements Packet

Your Hot Tub Pre-Delivery Guide

Master Control Systems, Inc. Variable Speed Fire Pump Controllers

Master Control Systems, Inc. Variable Speed Fire Pump Controllers

You are now the proud new owner of an Alpine Swim Spa!

Jackson County Department of Public Health Application to Construct, Install, Remodel or Modify a Public Swimming Pool

BRILLIANT WONDERS LED BUBBLERS INSTALLATION INSTRUCTIONS & PRODUCT MANUAL CMP SERIES

AMITY TWP POOL REQUIREMENTS

Pool Name Length Width Lineal Ft. Gallons Weight $ Price $

Vertex VP Operation and Maintenance

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

Spas Hotels/Resorts Apartments & Condominiums Campgrounds Health Clubs Medical Clinics Waterparks

WARNING: FOR OUTDOOR USE ONLY

Concentrate Distribution System (Stand Mounted) A-CDS-70-X & A-CDS-TANK-X-ST Industrial Drive, Orlinda, TN 37141

APPLICATION FOR A PERMIT TO CONSTRUCT OR ALTER A PUBLIC SWIMMING POOL, SPA POOL, WADING POOL OR FOUNTAIN

MOREHEAD CITY COUNTRY CLUB POOL BUILDING

GWINNETT COUNTY SWIMMING POOL PLAN REVIEW CHECKLIST

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units Digital Range

Bulletin Swimming pool, hot tub and spa installations Rules , , , , , and

ROCKDALE COUNTY NEW SWIMMING POOL PLAN REVIEW

Ventam 85 Installation & Commissioning Instructions

VETROSON. OXY-GEN SYSTEMS (Oxygen Generating Systems) Question & Answer Brochure

KERN COUNTY PUBLIC HEALTH SERVICES DEPARTMENT ENVIRONMENTAL HEALTH DIVISION

PLAN REVIEW NEW CONSTRUCTION AND MAJOR REMODEL WORKSHEET

The purpose of this brochure is to explain to owners and contractors the City of Burnaby s requirements for private swimming pools.

Saline C 6.0 Junction Box

O r i g i n a l. E n d l e s s P o o l. P l a n n i n g G u i d e

1 Exam Prep NSF/ANSI Tabs and Highlights

Dan Johnson, CBP Swim, Incorporated Lead Dog Aquatic Consulting

Pool Inspection. Your Street San Diego, California Prepared for: Your Name Prepared by: Priority Inspection Service

2018 MODEL. SwimFit / SwimExpert INSTALLATION GUIDE

GEN20AD-GEN20AL-GEN18AN

CARTRIDGE FILTERS. Models: CF50, CF75, CF100, CF150,

Propane Conversion Kit Instruction

City of Lockport Above Ground Pool Regulations

Customer Responsibilities

Flow Material Length. Weight GPM LPM. Style 3095

RESIDENTIAL SWIMMING POOL

Customer Responsibilities

IntelliTouch Pool and Spa Control Systems Smart and simple pool and spa automation

Pool / Hot Tub Permit

PumpAgents.com - Click here for Pricing/Ordering Nominal psi (bar) Cut-In Cut-Out

help make your spa installation a success Commissioned by Caldera Spas

SWIMMING POOL, SPAS, HOT TUB REQUIREMENTS AND GUIDELINES (Updated 3/2018)

icon i150 / i350 Installation / Operation Manual

Swimming Pool Plans and Specification Report

Check with local zoning official for property line distance requirements.

1020 Industrial Drive, Orlinda, TN fax

Original. Planning Guide

Production Booklet. for TELFORD SWIM SPA

PRECAUTIONS. Never enter the swim area unless the floating cover is completely removed and stored.

RESIDENTIAL SWIMMING POOLS AND SPAS A GUIDE FOR HOMEOWNERS

C.A.I. Customer Service Department 1462 East Ninth Street Pomona, CA Toll Free: CAL-SPAS Fax:

Jennifer Hatfield FSPA Government Relations Consultant J. Hatfield & Associates, PL

Operating Instructions

City of DuBois PERMIT APPLICATION P. O. Box 408, 16 West Scribner Ave - DuBois, PA Phone: Fax:

Fiber Optic Lighted Bubbler Spillway Pot (DLP-45) Installation Manual

Office Use Only Fee Paid

BRILLIANT WONDERS LED BUBBLERS INSTALLATION INSTRUCTIONS CMP SERIES. Brilliant Wonders LED BUBBLERS

COATINGS SPRAY GUIDE Acrylics (210, 211, 211HT, and 212)

NGP-250/500 Nitrogen Generator Quick Start Guide

Customer Responsibilities

SANITIZERS SANITIZERS SANITIZERS FOR POOLS & SPAS

2005 Spa Pre-Delivery Guide

USER S MANUAL BASIC HORIZONTAL OIL-LUBRICATED MICROCOMPRESSOR Reference: RCMPBH

Accu-Tab Systems 2000 P Series by Axiall Corporation

COATINGS SPRAY GUIDE Urethane 520

In Vessel Composter Installation & Commissioning Manual

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm

Acid- Rite ph Adjustment System 2500 by Axiall, a Westlake Company

2004 Consumer Planning Guide

HIGH PERFORMANCE POOL & SPA PUMPS

Customer Responsibilities

HAS2400 Hepa Air Scrubber

My Favorite Pool Builder, Inc.

Blue River Technologies Port-A-Poly Mixer w/2.5 GPH LMI Pump And Secondary Water Dilution Line INSTALLATION AND OPERATION

Pumping Systems for Landscaping Pumps, Controls and Accessories. Mark Snyder, PE

Smart JVA Module WARNING. For use with AquaLink RS systems with rev R firmware or newer.

SWIMMING POOL & SPA DOCUMENT SUBMITTAL LIST

PART I. GENERAL REQUIREMENTS FOR PERMANENTLY INSTALLED POOLS, STORABLE POOLS, OUTDOOR SPAS, OUTDOOR HOT TUBS, OR FOUNTAINS

RED DOT UNITS 72R SERIES. Controls. Water & Air PAGE 271

FX134, FX1234, FX3030 Problem and Solutions

Swimming Pool Requirements

City of Crystal Lake Community Development Department

Transcription:

ARCHITECTURAL GUIDELINES 1000 S

Architect Guidelines for SwimEx Installation Model 1000S GENERAL LAYOUT Call SwimEx at 800-877-7946 to receive AutoCad Drawings of the SwimEx Model that you will be installing. These drawings can be placed directly into your pool room layout and site drawings. SwimEx pools are available in two versions: For existing construction, the pool comes standard in four pieces. For new construction we recommend that the option for the pool assembly at the factory be purchased (SX512). In this case, the pool arrives as one piece and is placed into the facility early in construction. ** See Blueprint Section for sizes of pieces and whole pool. Provide a flat level surface for pool to sit on with a load bearing capacity of 525 lbs./sq.ft. **Footprint of pool must be level, remainder of pit or area can be sloped to drain water. Below ground installation requires a minimum pit of 18 wide by 25 long and 84 deep. The pit side walls provide no structure for the pool they are only retaining walls for keeping back fill from falling in against the side of the pool. Above ground installation requires a minimum ceiling height of 12 with no obstructions above the pool (Lights, vents, ducts, beams) ** Check local building codes for minimum ceiling height and required decking area. Every SwimEx comes standard with an entrance ladder. NO WINDOWS with this model. Based on the orientation of the pool within the room, these elements need to be placed in the optimum locations. Please familiarize yourself with the SwimEx orientation, and make sure that the order specifies the side for the stairs. The ladder can be placed on either side for no charge so long as the order indicates the location. Allow access to equipment and pool via access hatch for inground, or access panels for above ground installations.

DELIVERY REQUIREMENTS: Clear passage for 18-wheel tractor trailer truck to deliver and forklift on site to off load pool from truck. ** Please review Shipping Section of Manual. Clear passage from entry to the final location of pool. For the Model 1000S; door openings must be 94 wide by 94 tall with a clear area on both sides of the door ** Please review Site Preparation Section of Manual. SwimEx units are available assembled at the factory. The pool will then arrive in one piece and will be craned into position. Planning must be done so that this can occur early in the construction process to have complete access to the area. Typically this is the most cost-effective way for new construction installations. A clear, unobstructed working area in and around the pit must be provided for movement of the parts into the pit and assembly of the pool. No decking shall be constructed until the pool has been filled and water tested. Once the pool has been filled and water tested, the decking will need to be constructed around the SwimEx. This is not part of the SwimEx assembly, please refer to Deck Construction Section of the Manual for instructions. Electrical Requirements: Standard pool requires 220/240 Volt, single phase. Other voltage heaters are available, please contact SwimEx GFCI Breakers to be provided by electrician Paddlewheel Controller: 70 Amp 208/240V Single Phase (FLA 54 Amps)

Heater : 100 Amp 240V Single Phase (FLA 75 Amps) Pump: 15 Amp 208/240V Single Phase (FLA 7.8/7.4 Amps) Must provide sub panel with appropriate GFCI breakers for equipment ***Please refer to Electrical Schematic in Electrical section of Manual Variable speed controller takes 220/240Volt single phase in and converts to 3 phase to drive the gearmotor. Electrician, in accordance with local and national electric codes, must make all connections between equipment and circuit breakers. Connections to be made dealing with the SwimEx are from the breaker panel to the variable speed controller, controller to gearmotor, breaker panel to heater, and breaker panel to pump. These must be done on site by an electrician provided by owner. Conduit needed from Variable speed Controller to poolroom near front of pool for EDGE Touch Screen Monitor. Conduit must be able to let a 7/8 diameter connector pass through. The location of the EDGE must be 5 away from the pool and should be determined by the end user of the pool. Ozonator, 110V plug in unit. Should be connected through same line as Pump to ensure that it shuts off when pump is turned off. Other Equipment Considerations: Optional SwimEx equipment: *Please refer to Other Equipment Assemblies Section of the Manual Underwater Lights, 110Volt plug in unit on right or left side of pool. Provide switch to turn off and on in convenient location. Jet Option : Separate pump controlled by air switch 220V 15 amp required Non SwimEx Equipment provided by owner Sump Pump: Plumber will locate a sump pump within pit area, connection means must be provided for Lights under deck or in pit area: Pit area must have lights for future maintenance. Ventilation and exhaust requirements. MECHANICAL REQUIREMENTS: **Please read and familiarize yourself with the Plumbing section of the Manual Plumbing: Pool is pre-plumbed with all eyeball and suction fittings. On site plumber (by owner) must make connections between pool and provided pool equipment. All connections are PVC and will vary dependent on location. Typical connections are schedule 80 PVC and range from 1 to 3 in diameter.

Water fill: ¾ Cold Water fill line for pool (tempered water can be provided but is not required). The fill line must be protected by backflow preventers as required by local codes. Valve for water fill should be located within poolroom so that operator can see water level as pool is being filled. Drain: The SwimEx comes with a 2 drain from the front of the pool with a shutoff valve. A floor drain or sump pump and pit must be provided for semi annual draining of the pool. Drain from pool is elevated approximately 3 ½ from floor. Drain will have approximate flow of 80 GPM when pool is full. Hose Bibs: A hose bib is recommended (and required within some jurisdictions) within the SwimEx pool area for semi annual cleaning of the pool interior. Dehumidification: The SwimEX Model 1000S will have a 140 Sq.ft. of open water area. We recommend that the pool room temperature be kept within +/- 5 degrees of the water temperature. Typical water temperature will be 85-90 degrees. If the air and water temperature are kept this close we estimate the loss to be approximately 6 to 8 lbs/ hour. STANDARD EQUIPMENT The following is a list of the standard pool equipment supplied with the SwimEx Model 1000S PUMP: Pentair Pool Products Model: Whisperflow WFE-4 1HP filtration Pump 78GPM @ 60TDH Electrical Requirments: 208-240V single phase 15 Amp GFCI breaker (FLA 7.8/7.4 Amps NSF LISTED

FILTER: Pentair Pool Products Model: Clean & Clear Plus CCP 320 320 Square Feet of filtration Area Design Flow Rate of.375 G/sq.ft. for a flow of up to 120 GPM Connections 2 PVC Glue Unions Dimensions: 43 T x 21.5 dia Removal of cover req. 62 Height NSF LISTED HEATER: Coates Heater Company Model: 12418CE 18 KW Electric Heater Dimensions 118 ¼ L x 10 1/8 W x 11 ½ H Electrical Requirements: 240V Single Phase 100 Amp GFIC Breaker feed FLA 75 Amps (natural gas and propane options available)