METROSIL CURRENT TRANSFORMER PROTECTION UNIT (CTPU) ENCLOSURES IEC COMPLIANT

Similar documents
IECEx Certificate of Conformity Annexe

Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC

C&G 2395 Exam Paper June Section A-All questions carry equal marks. Answer all three questions. Show all calculations.

enclosures to ATEX and enclosures for special custom design (EEx p and NEMA cabinets)

2-1- Shipping Receiving Lifting Location on Site Installation Stages 6

Operating Instructions

L230 LED 40 Watt Searchlight

enclosures to ATEX and enclosures for special custom design (EEx p and NEMA cabinets)

C&G 2395 Exam Paper April Section A - All questions carry equal marks. Answer all three questions. Show all calculations.

Operating Instructions

9700 Transmitter Submersible hydrostatic level transmitter

INSTRUCTION MANUAL Pressure Relief Device LPT

Project: Consultant : MEP Contractor: PREPARED BY: DORMAN SMITH SWITCHGEAR - DUBAI REVIEWED BY CONSULTANT : Page 1 of 15

Single-Phase Pad-Mounted Distribution. Single-Phase Pad-Mounted Distribution Transformers KVA

Floor Mount Socket. T: +44 (0) F: +44 (0)

Technical Datasheet. Rigid & Retractable Pendants. Rigid Pendant

Pressure switch KP-E. Data sheet

Manual Power relay SR853

OSAT Series. Intrinsically Safe Infrared Temperature Sensor Operator's Guide

XMPA12B2142 pressure sensor XMP - 12 bar - G 1/4 female - 2 NC - without control type

Further technical information is available on

USER MANUAL. JET TST and JET TST S.

Technical Data. Dimensions

S Surge Arresters

London Underground - Section 12 approved Switch Disconnectors

Arran LED Floodlight Luminaire

ARCA cabinet NEW. High performance polycarbonate cabinet. Protection in demanding environments

PLEASE READ CAREFULLY BEFORE INSTALLING OR USING MEGA POOL SAVER MPS 1100

Technical Data. Dimensions

Types and approvals. Page 1/6. Data Sheet

LTB013EN. Operating Instruction Trimod Besta Level Switch types XA 5, XB 5 for use in potentially explosive atmospheres acc.

Guidelines to the standard IEC60601

Residential Swimming pools

ABTQ-110 rev 00 (Last review: 28 Aug 12) INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS FOR ABTECH S RANGE ENCLOSURES IECEx SIR U SERIAL No

EVRM-NC EVRM-6NC. delta-elektrogas.com. Safety solenoid valves for gas Manual reset - Normally closed DN10 DN300.

Operating Instructions

Pressure controls for hydro carbons, zone II applications, Type KPE

Phuel Modular Control Units

Advantage Lockers & Bike

Check with local zoning official for property line distance requirements.

Meta-MEC Manual Motor Starters

RESIDENTIAL SWIMMING POOLS AND SPAS A GUIDE FOR HOMEOWNERS

SEMME2135 Assisting in modifying and adding electrical circuits in yachts and boats

GAS INSULATED SWITCHGEAR

SG36KTL-M Quick Installation Guide. 1 Unpacking and Inspection

AutoChanger Installation & User Guide Issue 2

SM6. instructions for use. connection with compartment for incoming cable from the top. MV distribution factory built assemblies at your service

Ground Fault Circuit Interrupter(GFCI) Policy

Technical Data. Dimensions

ELECTRIC ACTUATORS for continuous underwater use

I003 Lock Out - Tag Out - Try Out. Document information

ph measuring system for hygienic process applications

Pneumatic spool valve islands

3M InCa Individual Cross-Connection Cabinets

IEC April Authorized Sole Agent : PT. Wisma Niagatama Perkasa. Phone : (031) Fax. : (031)

Vertex VP Operation and Maintenance

We Warm Animals. User Manual For. Darvall Heated Smooth-Wall Circuits. Darvall Heated ZDS Qubes

Installation, operating and maintenance Instructions for Seemag bypass level indicator

Pressure switch, Differential pressure switch and Thermostat RT-E

TECHNICAL DESCRIPTION

SECURITY AND CONFIDENCE AT HEIGHT

OEM Manual. MODEL ½ Digit DRUM SCALE

VMR VMR-OTN VMR 6 bar

SG33KTL-M Quick Installation Guide. 1 Unpacking and Inspection

QPEO2/037N Credit Value: 15 QCF Level: 2 GLH: 68 Maintaining electrical equipment/systems

UL TEST REPORT AND PROCEDURE

WINDSOCK MASTS TECHNICAL INFORMATION

* * Data Sheet and Operating Manual. Digital manometer ME01 ## # 87 # HL S#### Dust explosion protection Zone 22.

MEDICAL EQUIPMENT CATALOG

D. ACCESSORIES ADAPTER KITS IMPELLER & SEAL INSTALLATION TOOLS CARRYING HANDLES & LIFT CORDS GALVANIC PROTECTION KITS MUSHROOM STRAINER

PRO Lifting Operations

W E NE E D TO TA LK A BOUT COLD FLOW. The Problem With The Cold Flow Standard.

TOPLINE ELECTRONICS LTD CO2 CONTROL UNIT MANUAL

The definition of a competent person given in the Electricity at Work Regulations 1989 (EWR) is as follows:

PurgEx. X Purge Controller N Version. User s Manual

rugby rugby Millennium Posts Aluminium Posts No.1 Posts No.2a Posts No.3 Posts Heavy Duty Posts Post Protectors Rucking Pads

Infrared Linescanners

Junction Boxes Series 8118

steel wire cable tray system accessories

High-performance submersible pressure transmitter For level measurement Model LH-10

The accuracy and safety of the connected measuring devices are directly regulated. of the introduced current transformers.

Deep Submersible Level Transducer Series 300DS

CABLE ENTRIES IN HAZARDOUS AREAS CORRECT SELECTION, INSTALLATION AND MAINTENANCE

Current transformers Measurement devices from 5 to 5000 A

Ex-proof solenoid valves with spool position monitor on/off, with inductive proximity sensor - Multicertification ATEX, IECEx, EAC

Note: the lock-out circuit must be in accordance with Section 8.7 of DIN/VDE Twin thermostats ATH.-SW-2020 ATH.-SW-2070 ATH.

RTD temperature probes

Digital Melting Point Apparatus

Prewired position switches FA series

AUTOMATIC GAS MANIFOLDS

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

MODEL WEIGH MODULE

Transmitter CS 21 Operation Manual

RPS900W Redundant Power Supply. Installation Guide.

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

Automatic Valve Proving Control

Tightness controls TC 1 3 and TC 4

Technical Data. Dimensions

Ventam 85 Installation & Commissioning Instructions

SEMEM3-65 Servicing anaesthetic and ventilation equipment

Transcription:

IEC 649 COMPLIANT METROSIL CURRENT TRANSFORMER PROTECTION UNIT (CTPU) ENCLOSURES

INTRODUCTION Current transformer open circuit protection with reliability, flexibility and expertise built-in. Current Transformer Protection Units (CTPUs) are used to protect current transformers (CTs) from the damaging effects of secondary side open circuits. We ve combined our extensive application expertise and industry leading CT protection components with a new range of robust enclosures. Our new CTPU s offer a complete, pre-assembled protection system for supply chain simplicity and ease of installation close to the CT secondary. We can provide a number of different enclosure configurations based on three standard cabinet options to meet the specific needs of your application. All backed by extensive technical support and design assistance. CTPU s are the only enclosures/cabinets which are certified by. They contain the world s leading CT open circuit protection components from in a number of iterations to give the complete protection to all of your critical CTs. All enclosures are IEC compliant, and have been type tested in the bespoke CTPU test facility.

The CTPU enclosure series are offered in the following configurations. TABLE : ENCLOSURE OPTIONS option Number of CTPUs in the enclosure CTPU type (Type A, B, C, 66, 40, 4) size (WxHxD) (mm) Loaded weight (kg) - take number from the next chart International Protection Marking Impact rating Nema class Manufactured in accordance with IEC 649 CTPU - All W:80 H:80 D:0 9.8 CTPU - 4 4 All W:80 H:80 D:0 4 CTPU - 6 6 All W:600 H:800 D:50.6 IP66 IK08.7Kg / 5 joules 4 Yes CTPU - 8 8 All W:600 H:800 D:50 44.5 CTPU - 9 9 All W:600 H:000 D:50 50.5 CTPU - All W:600 H:000 D:50 67 Three standard enclosures have been selected to house the different numbers of CTPUs. The terminal layouts of the enclosures are detailed in the Wiring section. METROSIL CTPU ENCLOSURE FEATURES: Three standard cabinet sizes IP 66 rated Removable gland plate Sealed fasteners Fitted with integral basic protection barrier CE approved Direct connection and ease of installation close to the CT secondary Multiple SCADA signal wiring configurations METROSIL CTPU ENCLOSURE BENEFITS: Type tested and independently certified to IEC 649 Parts & Flexible fitting options for either a flat wall or pole mounting to suit site requirements Adaptable configurations depending on the arrangement of the CT protection systems Single supplier for CTPU components and enclosures to reduce supply chain complexity

ENCLOSURES The enclosures are fabricated from welded sheet steel and finished in RAL 705 epoxy powder coating. They feature a weatherproof door seal, removable baseplate for component fixing, an M8 copper earth stud, a bottom mounted gland plate with integral seal and a lockable door. They are certified to meet the requirements of IEC 649 Parts &. CTPU mounting options The enclosures can be attached to a flat wall surface or pole mounted using sealed fasteners that will maintain the enclosure s IP 66 rating. In addition, the fixings have been tested by the manufacturer and are load rated as shown in Table below. Both of these mounting devices can be ordered directly from M&I Materials as auxiliary extras. TABLE : INSTALLATION FIXINGS Item mounting type mountings Load rating M&I part No. Wall mount 500N / 50Kg / distributed over 4 brackets, symmetrical loading Pole mount 000N / 00Kg / distributed over brackets, symmetrical loading FME / WALL MOUNT / ENCLOSURE FME / POLE MOUNT / ENCLOSURE

CTPU GROUPINGS Terminal segregation arrangements The number of CTPUs housed in an enclosure is dependent upon the site requirements and also upon the number of protection systems the CTs are being used in conjunction with. CTs are commonly used in either a -phase (ph) or -phase and neutral (N) protection system. There may then be between 4 groups of CTs being protected within the CTPU cabinet, as shown in Table below, with each CT requiring its own dedicated CTPU. TABLE : TERMINAL SEGREGATION ARRANGEMENTS Size Product name CTPU per enclosure CTPU groupings Comments CTPU- CTPU-4 x ph Open Circuit protection of one x -phase set of CTs 4 x (ph + N) Open Circuit protection of one x -phase & neutral set of CTs CTPU-6 CTPU-8 6 x ph Open Circuit protection of two x -phase set of CTs 8 x (ph + N) Open Circuit protection of two x -phase & neutral set of CTs CTPU-9 9 x ph Open Circuit protection of three x -phase set of CTs CTPU- 4 x ph Open Circuit protection of three x -phase & neutral set of CTs CTPU- x (ph + N) Open Circuit protection of four x -phase set of CTs

MONITORING OPERATIONS The signalling thermostats of the CTPUs are commonly connected into a SCADA system to indicate the operation of the CTPU and the status of the CTs. Where multiple CTs are used in groups, the signalling thermostats can be interconnected in order to show either the status of individual CTs, or alternatively, groups of CTs. This will help reduce the number of conductors within the SCADA system. The CT common group terminals are identified as XnCT. where n =... for the largest enclosure. INDEPENDENT SIGNALLING CTPUs GROUP SIGNALLING CTPUs Group Group Ph Ph Common signalling from the individual group Ph Ph Separate signalling from individual group Ph Ph + N 4 + N 4 -XCT Group common terminal -XCT Group common terminal CTPU TERMINALS Example is for 4 CTPUs arranged in x (ph + N) configuration For each CTPU there are: current terminals to each of the CTs, and 4 terminals to the signalling systems. The diagram below shows the arrangement for 4 CTPUs. Similar circuit diagrams are available for larger enclosures. CTPU -4: Example below of terminal layout drawing and enclosure wiring schedule. Note: CTPU s are available in multiple sizes. High voltage/high temperature rated single core wiring cable.5mm CPTU R A R B Low voltage/high temperature rated single core wiring cable.5mm CPTU R A R B CPTU R A R B Arrangement for CTPUs per enclosure CPTU 4 R4 A R4 B Arrangement for 4 CTPUs per enclosure CTPU-A CTPU-B CTPU-C CTPU-D XCT CTPU-A CTPU-B CTPU-C CTPU-D XCT CTPU-A CTPU-B CTPU-C CTPU-D XCT CTPU-4A CTPU-4B CTPU-4C CTPU-4D X4CT GROUP S S LK LK GROUP S S LK LK GROUP S S LK LK For CTPUs GROUP 4 4 S 4 S 4 4 4 LK 4 LK For 4 CTPUs TERMINAL CONNECTIONS FROM SITE VIA GLAND PLATE Commoning link Link fitted for common connections of the XCT (XCT or X4CT) Terminals Link removed for sepatate connections of the XCT (XCT or X4CT) Terminals 5

COMPLIANCE IEC 649 All CTPU s are designed and manufactured according to IEC 649 Parts &: 009. Full details of the testing undertaken to achieve this can be supplied upon request. CE all enclosures are CE certified (under directive 04/5/EU low voltage directive). Proof of certification is available on request. Approved CTPU enclosures are the only enclosures/cabinets which are manufactured and approved by. Every single cabinet will have to pass through our world renowned QC procedure before being signed off by a qualified member of our quality inspection team. Only then will each cabinet be given the badge of assurance. ISO 900:008 M&I Materials, the parent company of, is certified to ISO 900 standards. ISO 400 M&I Materials Ltd, manufacturer of specialist materials for industry and science, has achieved certification by Lloyd s Register Quality Assurance under the Environment Management Standard ISO 400. MANUFACTURER: M&I Materials Ltd, Hibernia Way, Trafford park, Manchester, M 0ZD, UK. EQUIPMENT DESIGNATION: CTPUs in s. ENVIRONMENTAL: Ambient temperature (5 o C to 45 o C). SCOPE OF SUPPLY TABLE 4: ENCLOSURES Item CTPUs per enclosure Fully loaded enclosure weight (kg) M&I part No. 9.8 FME / * / ENCLOSURE / CTPU / 4 4 FME / * / ENCLOSURE / CTPU / 4 6.6 FME / * / ENCLOSURE / CTPU / 6 4 8 44.5 FME / * / ENCLOSURE / CTPU / 8 5 9 50.5 FME / * / ENCLOSURE / CTPU / 9 6 67 FME / * / ENCLOSURE / CTPU / *Substituted for CTPU types A, B, C, 66, 40 or 4 e.g. FME / 4 / / CTPU / 6 No mixed CTPU types are permitted in an enclosure

HANDLING, INSTALLATION & MAINTENANCE INSTRUCTIONS The following instructions are to be followed for the safe handling, installation and operation of the designated series of equipment. INSTALLATION INSTRUCTIONS Observe safe lifting and handling practices since the enclosures exceed the safe manual handling capacity of 5kg per person. Ensure the equipment is undamaged and that all door fittings, gland plates, fasteners and seals are intact before installing. Ensure that the installation location can safely handle the weight of the equipment before attempting installation. 4 Only the recommended installation fixings of four per enclosure attached at the designated locations on the rear of the enclosure shall be used. 5 The equipment shall be installed in a location that does not exceed the IP 66 rating of the cabinet. 6 Keep away from sources of direct heat (locally radiated and solar). 7 Ensure adequate clearance is provided for the circulation of air around the equipment. 8 Only use glands that are IP 66 rated and sized according to the cable selection for the end user application. 9 Remove the gland plate when making entries into the enclosure to avoid contaminating the equipment. 0 Ensure that all wire terminations into the enclosure are installed following recognised good standards of workmanship. Follow local site working instructions as necessary for the safe installation and use of the equipment. Ensure that all power is removed before attempting any electrical installation work and that the supply is locked off. Follow local site working instructions as necessary. MAINTENANCE INSTRUCTIONS There are no user serviceable components within the equipment. Periodic visual inspection of the equipment is recommended to ensure the equipment is undamaged and that all door locks and seals are intact. If damage is observed cease using the equipment and report the problem to your local authorised representative or directly to M&I Materials Ltd. Contact the team for further technical details about our range of CTPU s: ENQUIRIES Tel: +44 (0)6 864 5456 e-mail: metrosilsales@mimaterials.com metrosil.com Any recommendation or suggestion relating to the use, storage, handling or properties of the products supplied by M&I Materials Ltd either in sales and technical literature or in response to a specific enquiry or otherwise is given in good faith, but it is for the customer to satisfy itself of the suitability of the product for its own particular purposes. Registered Trade Mark.