LK-SX CO 2 +VOC. Application. Security Advice Caution. Notes on Disposal

Similar documents
LK-SX VOC. Application. Security Advice Caution. Notes on Disposal. Combined sensor mixed gas. Data sheet

Transmitter CS 21 Operation Manual

Transmitter CS 21 Operation Manual

Datasheet: K-30 ASCII Sensor

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

Operating Instructions

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

GasSense NDIR User Manual

Technical Data Sheet MF010-O-LC

CC Operation Manual Oak Valley Drive, Suite 20, Ann Arbor, Michigan USA fax

Please read these instructions carefully before use! Please consider the safety instructions! Please keep for future reference!

Electro-Pneumatic Converter YT-940 SERIES

Mass Flow Controller (MFC) for Gases

Mass Flow Controller (MFC) for Gases

INSTRUCTION MANUAL Pressure Relief Device LPT

Model PDT Dewpoint Transmitter

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

White Paper. Chemical Sensor vs NDIR - Overview: NDIR Technology:

Flow metering in gases Introduction to COMBIMASS family

MEMS VOC Gas Sensor. (Model No.:GM-503A) Manual. Version: 1.0. Valid from: Zhengzhou Winsen Electronics Technology Co.

* * Data Sheet and Operating Manual. Digital manometer ME01 ## # 87 # HL S#### Dust explosion protection Zone 22.

Atlas 6TM. Indoor Air Quality Monitor Instruction Manual. Measures CO 2, Temperature and Humidity DISTRIBUTED BY

Instruction Manual BA90 Precision Barometer

better measurement Simply a question of

O3 3E 1 F Gas Sensor Module

Torque Tube TB300 Digital Transmitters

Pre-filter for Brushless Blower Instruction Manual

QPL... Pressure Switches. Siemens Building Technologies HVAC Products

Mini-Pro CO2 Sensor User s Manual - ANALOG MODEL -

Air Differentail Pressure Switch

C-Flow Coriolis Mass Flow Meters

Oxymax W COS41. Technical Information. Potentiostatic amperometric two-electrode sensor Long-term stable sensor for water and wastewater applications

Mass Flow Meter (MFM) for gases

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)

D10S/D20S Wall/Post Mount Inflator Quick Start Manual

DF-310E PROCESS ANALYSERS APPLICATIONS FEATURES

Dextens Thermo Conductivity Sensors. Type 52101, 54101, 55101

Manual. MEMS Combustible Gas Sensor. Zhengzhou Winsen Electronics Technology Co., Ltd. (Model No.:GM-402B) Version: 1.0. Valid from:

Operation and Maintenance Manual

deltaflowc deltaflowc Venturi or Probe

Instruction Manual AD 1000 / BA 1000 Absolute Pressure Sensor

Mass Flow Meter (MFM) for Gases

AMS 2710 PCB pressure sensor module with V output

Thermal flow sensor TA Di for separate evaluation units for measuring mass flow, standard flow rate and air or gas consumption.

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

Oxymax COS61/COS61D. Technical Information

PLEASE READ CAREFULLY BEFORE INSTALLING OR USING MEGA POOL SAVER MPS 1100

Manual of SF6 Comprehensive Tester

TGD-L (LP) Tank Gauging Device TGD L (Level) TGD LP (Level Pressure) Main features:

Columbus Instruments

Phosgene Sensor. Sensoric COCl2 3E 1

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

Pressure Transmitters 36 F-27839

I/P Transducer Positioner Module

...makes sense! Combined CO 2 /O 2 analyzers. Monitor your process in real-time: OUR CER. BlueSens.com

Operating Instructions Temperature Measuring System MF420-5T-100

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

L3 Pressure and Level transmitter

User Manual. µ-gard MD Electrochemical Carbon Monoxide Transmitter Serial No. MD April, 2011

Autocalibration Systems For In Situ Oxygen Analyzers

DF-550E PROCESS ANALYSERS APPLICATIONS FEATURES

OSAT Series. Intrinsically Safe Infrared Temperature Sensor Operator's Guide

Best Practice Guide, Servomex 2700

MD61 Thermal Conductor Gas Sensor

PROCESS ANALYSERS. SERVOPRO PureGas. Gas Purifier. Operator Manual. Part Number: A Revision: 0 Language: UK English

Oxymax H COS21. Technical Information. Sensor with long-term stability for frequent sterilization and autoclaving

Solenoid gas valve. The solenoid gas valve is also applicable as a main gas valve Pilot gas valve for forced draft burners

Over 20,000 Strain Gage Target flowmeters installed since 1952.

Ozone. Sensoric O3 3E 1

Magnetic level switch type MR783 Instruction Manual

Vortex Flow Sensor VA Di Ex-d for flow measurement in gases; with integrated, configurable transducer UVA in Ex-d housing

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

FPD20 Series. Gear wheel flow sensor

Dual Solenoid Gas Valve Installation

GAS FUEL VALVE FORM AGV5 OM 8-03

Autocalibration Systems for In Situ Oxygen Analyzers

Operating Instructions Part No

ATS430 turbidity sensor Retractable insertion assembly

Type 3709 Pneumatic Lock-up Valve. Translation of original instructions. Mounting and Operating Instructions EB 8391 EN

DTG - LCD Digital Temperature Gauge USER MANUAL

Operating Instructions Part No

Gas density monitor With integrated transmitter Model GDM-100-TI

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

OXY 3690 MP. Measuring transducer for air oxygen

Operating Characteristics and Handling Manual for the NAP-55A / NAP-50A Explosive/Flammable Gas Sensor NEMOTO

HUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation

Art PRESSURE REDUCER

TEK-THERMAL 1700B. Thermal Mass Flowmeter. FLOW. Technology Solutions

JUMO dtrans p30 Pressure Transmitter

KTE6000 / KTU6000 Series OEM pressure transmitters for industrial media

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

Electropneumatic Transducer (I/P) Installation, Operation and

RAM 4021 Operation Manual

PRELIMINARY DATASHEET

Climatic Independent Level Sensor LAR

RAM 4021-DPX Operation Manual

Specifications of Oxygen Sensor Module V-8344A

PyroCouple Series Operators Guide

Gas Pressure Regulator HON 200

Transcription:

LK-SX CO 2 +VOC Sensor for detection of carbon dioxide (CO 2) and mixed gas content in air ducts Data sheet Subject to technical alteration Issue date: 24.08.2015 Application For detection of CO2 and VOC. Designed for duct mounted applications with up to 2 0..10 V outputs. Security Advice Caution The installation and assembly of electrical equipment should only be performed by authorized personnel. The product should only be used for the intended application. Unauthorised modifications are prohibited! The product must not be used in relation with any equipment that in case of a failure may threaten, directly or indirectly, human health or life or result in danger to human beings, animals or assets. Ensure all power is disconnected before installing. Do not connect to live/operating equipment. Please comply with Local laws, health & safety regulations, technical standards and regulations Condition of the device at the time of installation, to ensure safe installation This data sheet and installation manual Notes on Disposal As a component of a large-scale fixed installation, Thermokon products are intended to be used permanently as part of a building or a structure at a pre-defined and dedicated location, hence the Waste Electrical and Electronic Act (WEEE) is not applicable. However, most of the products may contain valuable materials that should be recycled and not disposed of as domestic waste. Please note the relevant regulations for local disposal.

Seite 2 / 5 Stand: 24.08.2015 Information about Indoor Air Quality CO 2 EN 13779 defines several classes for indoor air quality: Category CO2 content above the content in outdoor air in ppm Description Typical range Standard value IDA1 <400 ppm 350 ppm Good indoor air quality IDA2 400.. 600 ppm 500 ppm Standard indoor air quality IDA3 600..1.000 ppm 800 ppm Moderate indoor air quality IDA4 >1.000 ppm 1.200 ppm Poor indoor air quality Information about Self-Calibration Feature CO 2 All gas sensors are subject to drift caused by components. This fact results generally in the need to recalibrate the sensors regularly. With dual channel technology Thermokon integrates automatic self-calibration for different fields of operation. In contrast to common used ABC-Logic sensors with self-calibration dual channel are suitable for applications operating 24 hours, 7 days a week as for example hospitals. Manual calibration is not necessary! Application Notice for Air Quality Sensors VOC Unlike CO2 sensors, which specifically measure CO2, mixed gas sensors detect a wide range of gases. The sensor signal does not indicate the type of gas or it s concentration in ppm. Mixed gas sensors detect gases and vapours consisting of carbohydrates, or more generally gases that can be oxidised (burnt): Odours, perfume, cleaning fluid scent, tobacco smoke, new materials fumigations (furniture, carpets, paint, glue...). Unlike CO2, which humans cannot sense, the amount of odours (VOC) indicates the level of air quality. VOC sensors have proven their value in a multitude of applications for many years. Measuring principle: Similar to a catalyst converter the organic molecules are burnt (oxidized) when in contact with the sensor s heated -dioxide surface, adding a small amount of heat combustion. The increased temperature is measured providing a signal proportional to the number of molecules being burnt. CO2 cannot be detected as it cannot be further oxidized. Refrain from touching the sensor s element sensitive surface. Touching the sensitive surface element will void warranty. Information about Calibration VOC Similar to a catalyst converter the VOC sensor will deteriorate over time, which will affect the sensitivity. This VOC sensor automatically compensates the decrease in sensitivity by dynamic auto-calibration. The reference level of air quality is derived from the ambient conditions over a 72h period. The lowest reading within this 72h time period will be used as reference level, representing the clean and fresh air level.

Stand: 24.08.2015 Seite 3 / 5 Technical Data Measuring values CO2, VOC Output voltage 2x 0..10 V, load min. 10 kω Power supply 15..24 V = (±10%) or 24 V ~ (±10%) Power consumption max. 1,5 W (24 V =) 2,9 VA (24 V ~) Measuring range velocity 0..100% Measuring range CO2 0..2000 ppm Accuracy CO2 ±75 ppm or ±10% of measured value Calibration Self calibration dual channel (CO2) Air speed min 3 m/sec, max 10 m/sec Sensor VOC-Sensor, NDIR (non-dispersive infrared) Enclosure PA6, pure white Protection IP54 according to EN 60529, IP65 with bolted cover Cable entry M20 for wire max 8 mm Connection electrical Terminal block max 1,5 mm² Pipe PA6, black, Ø=19,5 mm, L =180 mm Filter stainless steel, wire mesh Ambient condition 0..+50 C, max 85% rh non-condensing Weight 400 g Delivery content MF20 flange Notes mixed gas sensors detect gases and vapours which can be oxidised (burnt): Body odours, tobacco smoke, exhalations emitted by materials (furniture, carpets, paint, glue...) Mounting advices The sensor can be mounted on a flange (recommended) or directly into the ventilation duct. Please note that during installation the openings of the pipe are mounted in the direction of air flow! Mounting without and with mounting flange:

Seite 4 / 5 Stand: 24.08.2015 Mounting with mounting flange Dismounting Advices Remove the lower section of the sensor carefully and pulling straight out. Pay close attention to the correct dismantling of the component! Connection Plan Clamp Function 1 24 V 2 GND 3 Not used 4 Not used 5 Not used 6 output CO2 0..10 V 7 output VOC 0..10 V

Stand: 24.08.2015 Seite 5 / 5 Application notice Dirt in the air can collect on the filter and then adversely affect the operation of the sensor after a certain time. Under normal ambient condition an annual maintenance is recommended. Rinse the filter after cleaning with distilled water and dry it using clean oil-free air or nitrogen. Extremely contaminated filters should be replaced. At extreme ambient conditions, e.g. corrosive gases, the humidity sensor may have to be changed. Dimensions (mm) Accessories Rawl plugs and screws (2 pcs each) Item No. 102209 Filter stainless steel, wire mesh Item No. 231169 Mounting flange MF20 TPO Item No. 612562