Description. Measuring Device 3760XBI USP. Balancing

Similar documents
CONSOLE-320 ENGLISH. 230A: CONSOLE-320 with cable data output Item 230B: CONSOLE-320 with cable + wireless radio data output

xx TA-CMI. User Manual

Instruction Manual Dräger MSI P7 and MSI P7 plus

STA. Double regulating valves DN 15-50

Additel 761 Automated Pressure Calibrators Selection Guide

Additel 761 Automated Pressure Calibrators

Hand-held pressure calibrator with integrated pump Model CPH6600

Additel 761 Automated Pressure Calibrators Selection Guide

STAD-D. Balancing valves Balancing valve for domestic water systems, DN Balancing valves

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

Pressure Calibrators. Series PC..., PM...

DM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

STAG. Balancing valves Balancing valve with grooved ends DN

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05

Additel 761 Automated Pressure Calibrators

Additel 761 Automated Pressure Calibrators

Pneumatic high-pressure controller Model CPC7000

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

Automatic Isokinetic Sampler. ST5 Evo

Precision digital pressure gauge Model CPG1000

The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions

AMS 6915 Board mount pressure sensor with digital output (I²C)

STA. Double regulating valves DN 15-50

ADT 761 Automated Pressure Calibrator

Pneumatic high-pressure controller Model CPC7000

159 mm 154 mm. Subject to changes 10/2012

STAD-C. Balancing valves DN 15-50

STAD. Balancing valves DN (MD60, MD61, MD62)

Automatic Isokinetic Sampler. ST5 Evo

BAROMETER PRESSURE STANDARD PRESSURE CONTROLLER

Precision pressure sensor Basic version Model CPT6020

BS12N Piezoresistive OEM Pressure Sensor

SonoMeter 30 Energy Meters

BS12 Piezoresistive OEM Pressure Sensor

We measure it. For gas and water installers. testo hpa. bar

Expert Hydrostatic Level Transmitters

STAD-C. Balancing valve ENGINEERING ADVANTAGE

Programmable pressure and temperature transmitters PTM/RS485

AMS 2710 PCB pressure sensor module with V output

DPI 610/615 Series. Druck Portable. Pressure Calibrators. GE Sensing. Features. Setting the Standard for Portable. Pressure Calibrators

Programmable pressure and temperature transmitters PTM/RS485

This multi-functional device allows the determination of up to six quality parameters with only one measurement:

Parametrable / Programmable Pressure Transmitter

AMS 6916 Board mount pressure sensor with ratiometric analog output

STAD. Balancing valves DN 15-50

陕西创威科技有限公司. Shaanxi Creat Wit Technology Co., Ltd. Precision pressure calibrator-cwy300 Operating Manual

Benefits. Rev.III_032018_Oxybaby 6.0_engl subject to technical alterations

Pegas 4000 MF Gas Mixer InstructionManual Columbus Instruments

Electronic Commissioning Unit. Instructions

How to specify a product. Process Sensors and Mechanical Instruments

DIGITAL AUTOMATIC TYRE INFLATOR

Programmable Submersible Level Transmitters

G100 Range. Operating Manual

Flow Indicator - Measuring Device for Flow and Pressure

Mass Flow Meter (MFM) for Gases

Automatic Balancing Valve Pressure difference controller with integrated flow limiter AB-PM DN

OxyScan Graphic. Operating Instructions. UMS Micro-oxygen sensor 501. Microprocessor instrument

Manual Weighingblock VB2 series and Uniscale

Instruction Manual Differential Pressure Transmitter

Mass Flow Controller (MFC) for Gases

DG100 Digital Depth Gauge and Timer. Training Module, Rev B

Electronic Volume Correctors

Technical Datasheet. D Series SMART Pressure Transmitter Model: DPC D-Series. Key Features. Series Overview. Product applications

Pneumatic service kit Model CPG-KITP

Pressure independent control valve (PICV) FLOWMATIC

Computerised balancing instrument

DPC-30 DPC-100. Reference Manual

Digital pressure gauge Model CPG500

Operating Manual. SUPREMA Calibration. Software for Fire and Gas Warning Units. Order No.: /01. MSAsafety.com

86BSD Backside Digital Output

GAS ANALYSER OXYBABY 6.0 for O 2. or O 2 /CO 2

Mass Flow Controller (MFC) for Gases

Digital Pressure Gauge Main features: Data Sheet: BIT02B.417.R6.EN COVER on request

ASDX Series Silicon Pressure Sensors

OPERATION MANUAL DIVE CALIPER NOT SCALE / IF IN DOUBT ASK* *ALL UNITS IN MM/DEGREES UNLESS SPECIF. Dive Caliper General DC-051

ALL-IN-ONE MINI THERMAL MASS FLOWMETER

Optical Dissolved Oxygen Meter

MASSACHUSETTS STATE POLICE CRIME LABORATORY. Certificate of Calibration Procedure for the Alcotest 9510

Operating manual for the pressure transducer unit CCS 1000

TH-1800-T TRX-700-CNG Converter

EPP4 Pressure Regulator Basic G 1/4"

Bante821 Portable Dissolved Oxygen Meter Instruction Manual

AIR FLOW CALIBRATORS Single Sensor Designs

G100 RANGE G100, G110, AND G150 OPERATING MANUAL

ACTUATORS AND INSTRUMENTS

TA-Modulator. Combined control & balancing valves for small terminal units Pressure independent balancing and control valve for modulating control

Short manual testo

Datasheet TM40. HUBER INSTRUMENTE AG, Grellingerstrasse 23, CH-4208 Nunningen. All rights reserved Paige 1 / 5 Datasheet_TM40_

Additel 780 Series Pressure Controller

GEM-500 OPERATION MANUAL

GAS ANALYSER OXYBABY M+ for O 2. or O 2 /CO 2. standard version

Radiator thermostats type RA2000, valve bodies type RA-FN (series D) and RA-G

For a similar sensor with o-ring mounting, refer to the 85BSD digital output pressure sensor.

Versions. Benefits. Balancing DN15-32 DN40 DN50 DN15, DN20, DN25, DN32, DN40, DN50. Dimensions

OXYBABY - MOBILE HAND HELD GAS ANALYSER

2600T Series Pressure Transmitter Models 264DC Differential and 264HC Gage Level Transmitters. Kent-Taylor

SX150A. Features. Typical Applications. Description

CF8-W-Disp-CO. User manual. CO 2 / CO sensor with built-in general purpose controller

Bante820 Portable Dissolved Oxygen Meter Instruction Manual

PTG100 Precision Test Gauge

Transcription:

Measuring Device 3760XBI Description 3760XBI comprises from a differential pressure unit with an integrated true differential pressure sensor for the exact measuring of both differential and static pressures in hydronic systems. The flow in the individual branches within the hydronic system is calculated from preprogrammed characteristics of balancing valves. The characteristics of most balancing valves from major European producers are included in 3760XBI memory. 3760XBI is able owing to the advantages gained by the use of digital technology to compensate for temperature effects and non-linearity of differential pressure sensor and achieves excellent measuring accuracy. USP Available in 15 different languages Temperature and medium correction Upload or Download projects data Balancing report available for printing Back light display Simple valve identification by image Memory up to 1200 valves Memory up to 20 000 records 1

General information Basic measurement for the device is the measurment of the differential pressure on the measurment point in the distribution system of the heat transfer medium (balancing valve or measurement orefice). For the pressure measurment is used full differential piezoresistive pressure sensor with the digital data treatment. On the digital way is compensated influence of the temperature on the pressure measurement, nonlinearity error and the influence of the static pressure in the systém on the differential pressure measurement and by the help of this corrections we can reach excellent measurement accuracy. For the flow calculation you can choose measurement point (balancing valve or measurement orifice) from the valve database saved in the internal device memory. For the decreasing the possibility of the bad choice of the valve you can compare the picture of the valve in the database with the valve you see before you. In the systems with the antifreeze liquids you will measure the right flow after the choosing liquid type in the menu and inserting the concentration and temparature of the liquid in the menu. Pressure and flow you can display in european and american units. A matter of course is the possibility of the overpressure and underpressure measurement, so it s possible measure also static pressure of the medium in the heat distribution system.by the measuring of a large heat system you can use the function Projects. In your office you can prepare in the PC model of the system and download it in the device. By the measurement in the in the field you choose only the branch and the measured data are automaticaly saved in the model. Measured project you can read out in the PC after that and print for eg. Balancing protocol. Composition New case, IP65, with hard separator Li-ion battery charger with mini-usb connection Robust foam for long lasting and lean organization Spare filters Needle (for TA, Danfoss, Oventrop... valves) and fast connection (Comap) pressure ports adapters 2

General outlook Negative input (downstream) Positive input (upstream) Up Zero Delete Cancel: Back Valve Previous Down On / Off Menu Preset Next Space USB input (PC connection) Content of the case: 1 instrument XBI 1 Allen key 2 connection hoses (blue and red) 1 set of fast connectors (Comap type)* 1 adaptor for drain connector * 1 set of adaptors needle type 1 mini USB for PC connection + Battery charger 1 CD for the software 1 user manual *valve Comap 750 Only 3

Reference Designation Reference Measuring device 376010 Needle adapter TA valve 275631 Pair of filter Cable for measuring device Red and blu VMP07A06 376015 Technical parameters Pressure Sensor Pressure Range Maximum Overpressure Nonlinearity and Hysteresis Error Temperature Error influence ambient and medium temperature Medium Temperature Range Piezoresistive true differential sensor 1000 kpa *2000 kpa 1200 kpa **2200 kpa Ambient Temperature Range -5 up to 50 C Storage Temperature -5 up to 50 C Connection of the pressure on the device Connection of the pressure on the hoses valve site Display Battery Power Consumption Power Comsumption in the Off line Charging Number of the records Number of the valve producers Number of the valves Dimensions 0,15 % of the pressure range 0,25 % of the pressure range -5 up to 90 C (at the end of the measuring hoses) quick coupler R20 quick coupler R21 color graphical display 320x240 pixels, diagonal 2,2 inch (56 mm) built in Li-Ion rechargeable battery 900 mah 80 ma max 50 ua USB charger 5V/200 ma, mini USB, 5 hours 20000 max. 32 max. 1200 max. 80 x 180 x 52 mm 4

Weight Cover Calibration Validity 420 g IP65 12 months * optional ** for optional pressure range 2000 kpa Quick Start 1. Introduction Plug- (upstream) Plug+ (downstream) Mini USB (Connection PC) Keyboard I MENU Switches ON / OFF the instrument Display Menu or- Back to previous menu level ZERO Reset or- Delete Cancel Cancel or- Back to previous level VALVE PRESET Display (pressure, flow, Kv, date / hour) or- validates the selection Valve selection or- Previous page from the list Valve setting position or- Next page from the list Reduces the value or Next field or 5 Next element from the list Increases the value or- Previous field or- Previous element from the list

2. Configuration Pre-recorded valve selection Before starting to measure, please specify the valve Select a pre-recorded valve VALVE Comap 750 AB DN 20 To use identical valves several times, just modify the setting. PRESET Max : 40 32.0 Min: 5 Enter the position indicated on the display of the valve Measure by kv value If the valve cannot be found, and the value of the kv is known, the kv value is needed. Proceed as previously to select in the valves list «Direct Kv» then «0 50000» Enter the Kv value PRESET Direct Kv 23.5 Min: 5 Enter the appropriate kv value 6

Entering value Each value is entered digit by digit ZERO Deletes the last digit Decreases the value of the digit (0-9 and.) O K Validates and creates a new digit Increases the value of the digit (0-9 and.) PRESET Next field () 3. Changing the fluid The fluid type is displayed on the left bottom of the screen MENU Fluid Select the type, concentration and temperature 4. Connect Resetting This procedure should be done when restarting the device. Recommended before all measure. ZERO Connect the hoses to the valve: Red: Valve upstream Blue: Valve downstream Connect the red hose (R) to the instrument. The value is stabilizing after a few seconds. Press. Connect Plug + Pressure 0.00 7

Connect the blue hose (B) to the instrument. The value is stabilizing after a few seconds. Read the flow Connect Plug - Pressure 0.00 B R B R B R 5. Measure Once the configuration is done, the instrument displays at any time the differential pressure, the flow, the valve, the setting of the valve, and the fluid. 6. Time period record MENU Records New Open Remove New record 8

Before starting recording, select the valve. Give a name to the record (see «entering values») Indicate the recording duration and the number of samples. Start the recording. The instrument automatically puts into sleep mode to save battery, but keeps on recording. Press I to turn on the instrument. Attention: DO NOT FORCE THE EXTINCTION, THIS MAY RESUME THE RECORDING 9

7. Valve in memory Most of the valves from the following manufacturers are already pre-recorded in the instrument: COMAP, Broen, Cimberio, Danfoss, Esbe, Heimeier, Herz, Honeywell, Oras, Oventrop, Quitus, TA, Tiemme, VIR 8. Valve in memory The 3760XBI is able to work with projects by defining the global architecture of a network. Please refer to the user manual for more explanation on this mode. 9. Work with project The 3760XBI is able to work with projects by defining the global architecture of a network. Please refer to the user manual for more explanation on this mode 10. Maintenance Replace the hoses filters The filters for the flexible hoses (ref 3760F) should be replaced every 6 month to prevent dirt obstruction Instrument periodic maintenance and calibration The device should be periodically re-calibrated, every year. Please return the device to your local Comap representative. The information about the last calibration date can be found in the menu «Options / device information» 10