Wind and Fastener Calculation Report for property located at

Similar documents
Design wind pressures and forces are determined per equations given in section : q Gf Cp - qi GCpi : at height z above ground Resisting System

STRUCTURAL DESIGN FIGURE INTERNATIONAL BUILDING CODE 288aR

ASCE D Wind Loading

TESTING APPLICATION STANDARD (TAS)

HH Gregg Building Northgate Mall Cincinnati, Ohio May 14, 2014

UNIVERSITY OF HONG KONG LIBRARY. Hong Kong Collection

External Pressure Coefficients on Saw-tooth and Mono-sloped Roofs

Post-Charley Evaluation of Undamaged Homes in Punta Gorda Isles

provides an increased stiffness and strength compared with standard cee studs, resulting in lighter headers which require less labor to install.

NCSEA Webinar March Michael O Rourke PE, Ph.D. Rensselaer

WIND EFFECTS ON MONOSLOPED AND SAWTOOTH ROOFS

PRELIMINARY STUDY GIFFY BARRELS TENT BALLASTING SYSTEM. Prepared for: Giffy Tent Barrels tm, Inc. Date: December 27th, 2014.

FAIRWAY PALMS II CONDOMINIUM PROPERTY

Loads on Structures. Dead Load / Fixed Load Live Load / Imposed Load Earthquake Load Wind Load Snow Load

RESIDENTIAL BUILDING PLAN REVIEW CHECKLIST

WIND FAILURES. Avoiding a Roof Failure Requires an Understanding of Many Factors Other Than Wind Speed. m-m. CatWOrl

COMPARISON OF WIND LOAD STANDARDS. by SHRINIVAS KOLA, B.S.C.E.. A THESIS CIVIL ENGINEERING

PHASE 1 WIND STUDIES REPORT

6.0 ENGINEERING. Build Anything Better. REPRINTED 2017

FALL PROTECTION

Effects of wind incidence angle on wind pressure distribution on square plan tall buildings

Wall Bracing Examples: Building #1 One-Story

CIVL473 Fundamentals of Steel Design

Evaluating the Design Safety of Highway Structural Supports

This program is registered with the AIA/CES for continuing professional education. As such, it does not include content that may be deemed or

LPCorp.com

Basis of Structural Design

7500 W 29th Ave, Wheat Ridge, CO Report Dated: 7/21/2017. Precise Aerial Measurement Report

A Wind-Tunnel Study of a Cubic Rooftop AC Unit on a Low Building

8. Fall Protection Procedures WAC

STRUCTURAL CALCULATIONS FOR. EXTREME MARQUEES TENTS Summit Range 2.4x2.4, 3x3, 3x4.5, 3x6, 4x4, 4x8, 6x6m

Strong Way Systems Wood Column with SWS Foundation System. Chart 1

Wind Pressure Distribution on Rectangular Plan Buildings with Multiple Domes

EXPERIMENTAL STUDY OF WIND PRESSURES ON IRREGULAR- PLAN SHAPE BUILDINGS

CEILING JOISTS ROOF RAFTERS

HIPPLOCK. User s Safety Manual

Town of Poughkeepsie Received: Permit # Aboveground/Inground Pool Building Permit Application

Pressure coefficient on flat roofs of rectangular buildings

Internal pressures in a building with roof opening

Length and Depth x x 7.23 m Clearance (Inclined roof) 14 7 to m to 3.87 m Maximum Height with Roof Tent

TRUSS ANCHORING. A guide on the use of Howe and Fink truss anchors

2.4 Gutter and Downspout Sizing and Location Calculations

For use with the STEICOjoist System

Wind Loading Code for Building Design in Thailand

Western Lumber SPAN TABLES. Western Wood Products Association. for Floor and Ceiling Joists and Roof Rafters. computed with

2001 AASHTO Training Manual

PFS Test Report TL-109

MEMORANDUM. NFPA Technical Committee on Lightning Protection Systems. NFPA 780 Supplement ROC TC FINAL Ballot Results (F2012Cycle)

Fortified For Safer Living

APPENDIX G SCA BASIN CALCULATIONS

A Basic Approach to the Installation of Small Movement Expansion Joints. Peter Weykamp, P.E.

Appendix Table of Contents:

Addendum to the 3 rd Edition of the Concrete and Clay Roof Tile Installation Manual

DREW UNIVERSITY FALL PROTECTION PROCEDURE (DRAFT 12/11)

Fall Arrest Anchor Solutions

Chapter 5. General Site and Building Elements

PERFORMANCE TEST REPORT FOR AIR LEAKAGE AND DURABILITY OF BARRIER PRODUCTS ASTM E Rendered to: BAUTEX SYSTEMS

2012 CALIFORNIA PHYSICAL FITNESS TEST. e-template REFERENCE GUIDE

Wind Directional Effect on a Single Storey House Using Educational Wind Tunnel

DESIGN CODE. Enterprise West Harlow London Road North Design Code 21

TURN ARROW. LANE-REDUCTION ARROW (RIGHT) (For Left Lane, Use Mirror Image) LANE-REDUCTION ARROW MARKING DETAIL

Date: Period: Directions: Answer the following questions completely on a separate sheet of paper.

REPORT HOLDER: FRAMECAD LICENSING LTD. POST OFFICE BOX 1292 AUCKLAND 1140 NEW ZEALAND EVALUATION SUBJECT: COLD FORMED STEEL C SHAPES AND TRACKS

Wind Flow Validation Summary

Outlet Structures T-12

MJA Rev 10/17/2011 1:53:00 PM


A Performanced Based Angle of Attack Display

TECHNICAL BULLETIN USE OF SNOW GUARDS

EXPERIMENTAL RESEARCH ON COEFFICIENT OF WAVE TRANSMISSION THROUGH IMMERSED VERTICAL BARRIER OF OPEN-TYPE BREAKWATER

Comparison on Wind Load Prediction of Transmission Line between Chinese New Code and Other Standards

Patio & Building Products

INSTALLATION NOTES HURRICANEFABRIC.COM

Wind Engineering Research Field Laboratory Selected Data Sets for Comparison to Model-Scale, Full-Scale and Computational Fluid Dynamics Simulations

Building Planning PART. Chapter 3. Chapter 3. Building Planning. Climatic and Geographic Design Criteria C

Ship Stability. Ch. 8 Curves of Stability and Stability Criteria. Spring Myung-Il Roh

Less bars, more light Maxilite Aluminium Roof Lanterns

Example Applications of the Proposed Medical Diagnostic Equipment Accessibility Standards

Competent Person - Fall Protection Presented by Turner Safety- your instructor is Steve Turner

DIVISION: 06--WOOD AND PLASTICS SECTION: Wood, Plastic and Composite Fastenings

for Cold-Formed Steel Framing Products

EXAMPLE MICROLIGHT AIRCRAFT LOADING CALCULATIONS

A Post ETHAN ALLEN Capsizing Assessment January 1, 2017

SCHOOL DISTRICT PALM BEACH COUNTY BUILDING DEPARTMENT PLAN REVIEW CHECK LIST -- ARCHITECTURAL

Solving ACC Axial Fan Wind Related Problems

Pool Submittal & Inspection Packet

Trampoline & Enclosure Assembly Instructions

Multihull Preliminary Stability Estimates are Fairly Accurate

Chapter 8 Darts and pleats

NSC Congress 31 October

POST TEST KEY. Math in a Cultural Context*

VICTORIAN AND CLASSIC SHINGLES INSTALLATION DETAILS BERRIDGE MANUFACTURING COMPANY

Task 16: Impact on Lummi Cultural Properties

Effect of Wind Pressure on R.C Tall Buildings using Gust Factor Method

Pneumatic high-pressure controller Model CPC7000

Overview. Identify fall hazardous areas Describing potential fall hazards How appropriate portable and extension ladders are used

Beach Profiles. Topics. Module 9b Beach Profiles and Crossshore Sediment Transport 3/23/2016. CE A676 Coastal Engineering

ADA Operations Contact Info

Tubular Aluminum Frames

PROPERTY EVALUATION AND RESERVE FUND STUDY ~UPDATE~

Transcription:

Martinez Antonio Wind and Fastener Calculation Report for property located at Martinez Antonio Universal Engineering, Inc 12828 Buckland St., Wellington FL 33414 Tel: 561-204-5000, Fax:561-204-1050 e-mail: aali@universalengineering.net UNIVERSAL ENGINEERIG, INC. 12828 Buckland St., West Palm Beach, FL 33414 Tel: (561) 204-5000, Fax: (561) 204-1050, Web: www.uefirm.com, Email: ali@uefirm.com Certificate of Authorization: 26583

Martinez Antonio Project Name: 3/30/2011 Martinez Antonio, Project Description Building average width: 60 ft. Building average Length: 58 ft. Eve Height: 8 ft. Deck Substrate: Wood Pitch: Flat Objective: Given Polyglass TAMKO Modified Bitumen Roof system over wood deck (check the associated NOA) 1) Provide wind calculations for the Field, Perimeter, and Corner areas for the flat roofs 2) Provide fastener schedule for the anchor/base sheet in the Field, Perimeter, and corner areas on a sound wood roof deck. Codes: The design herein is in compliance with Florida Building code with particular emphasis on Chapters 15 and 16; and Roofing Application Standards o. 117. Wind Design Criteria: Basic Wind Speed: 140 MPH 3 sec Gust, 130 mph sustained. Importance Factor: 1.0 Building Category: Enclosed Exposure Category: C Internal Pressure Coefficient = 0.18 Wind Pressures: The design wind pressure calculations are presented in Exhibit A of this report. The results for three wind roof zones are depicted Table 1. Table 1. Design wind pressure for the three roof zones Zone Zone 1, Field Zone 2, Perimeter Zone 3, Corner Wind pressure in psf -42.7214-71.685-107.89 UNIVERSAL ENGINEERIG, INC. 12828 Buckland St., West Palm Beach, FL 33414 Tel: (561) 204-5000, Fax: (561) 204-1050, Web: www.uefirm.com, Email: ali@uefirm.com Certificate of Authorization: 26583

Martinez Antonio The exterior zone width (Perimeter and Corner) is 3.2 ft. Fastener Schedule The anchor/base sheet fastener calculations were conducted according to Roofing Application Standards 117 and they are presented in Exhibit B. All fasteners and their tin caps are according to the product approval All lap sides are 4 inches. Fasteners shall be applied to the lap side row and the two center rows. The fastener spacing is according to the following schedule: Table 2. Fastener spacing in inches schedule for the three zones Zone Zone 1, Field Zone 2, Perimeter Zone 3, Corner 4 Lap side 9 6 4 center rows 9 6 5 Notes: 1. center rows are staggered. 2. number of center rows in the field is 2 rows 3. number of center rows in the perimeter and corner is 3 rows. 4. Builder may reduce spacing by 1 inch for construction convenience SEAL AL ALI, PhD, PE FL PE 53318 UNIVERSAL ENGINEERIG, INC. 12828 Buckland St., West Palm Beach, FL 33414 Tel: (561) 204-5000, Fax: (561) 204-1050, Web: www.uefirm.com, Email: ali@uefirm.com Certificate of Authorization: 26583

Martinez Antonio EXHIBIT A DESIGN WIND CALCULATIONS UNIVERSAL ENGINEERIG, INC. 12828 Buckland St., West Palm Beach, FL 33414 Tel: (561) 204-5000, Fax: (561) 204-1050, Web: www.uefirm.com, Email: ali@uefirm.com Certificate of Authorization: 26583

3/30/2011 WIND02 v2-03 Detailed Wind Load Design (Method 2) per ASCE 7-05 Description: 2464 PALM RD., Analysis by: Dr. Alaa Ali, PE. 3/30/2011 User Input Data Calculated Parameters Structure Type Building Importance Factor 1 Basic Wind Speed (V) 140 mph Hurricane Prone Region (V>100 mph) Struc Category (I, II, III, or IV) II Table 6-2 Values Exposure (B, C, or D) C Alpha = 9.500 Struc Nat Frequency (n1) 1 Hz zg = 900.000 Slope of Roof 0.3 :12 Slope of Roof (Theta) 1.2 Deg Type of Roof Monoslope Kd (Directonality Factor) 0.85 Eave Height (Eht) 8.00 ft Ridge Height (RHt) 8.00 ft Mean Roof Height (Ht) 8.00 ft Width Perp. To Wind Dir (B) 60.00 ft At = 0.105 Width Paral. To Wind Dir (L) 58.00 ft Bt = 1.000 Bm = 0.650 Calculated Parameters Cc = 0.200 Type of Structure l = 500.00 ft Height/Least Horizontal Dim 0.14 Epsilon = 0.200 Flexible Structure No Zmin = 15.00 ft Gust Factor Category I: Rigid Structures - Simplified Method Gust1 For rigid structures (Nat Freq > 1 Hz) use 0.85 0.85 Gust Factor Category II: Rigid Structures - Complete Analysis Zm Zmin 15.00 ft Izm Cc * (33/z)^0.167 0.2281 Lzm l*(zm/33)^epsilon 427.06 ft Q (1/(1+0.63*((Min(B,L)+Ht)/Lzm)^0.63))^0.5 0.9151 Gust2 0.925*((1+1.7*Izm*3.4*Q)/(1+1.7*3.4*Izm)) 0.8803 Gust Factor Summary G Since this is not a flexible structure the lessor of Gust1 or Gust2 are used 0.85 Fig 6-5 Internal Pressure Coefficients for Buildings, Gcpi Condition Gcpi Max + Max - Open Buildings 0.00 0.00 Partially Enclosed Buildings 0.55-0.55 Enclosed Buildings 0.18-0.18 Enclosed Buildings 0.18-0.18 Page No. 1 of 4

3/30/2011 WIND02 v2-03 Detailed Wind Load Design (Method 2) per ASCE 7-05 6.5.12.2.1 Design Wind Pressure - Buildings of All Heights Elev Kz Kzt qz Pressure (lb/ft^2) Windward Wall* 0 lb/ft^2 +GCpi -GCpi 15 0.85 1.00 36.20 18.10 31.14 Figure 6-6 - External Pressure Coefficients, Cp Loads on Main Wind-Force Resisting Systems (Method 2) Theta B z h L Variable Formula Value Units Kh 2.01*(15/zg)^(2/Alpha) 0.85 Kht Topographic factor (Fig 6-4) 1.00 Qh.00256*(V)^2*I*Kh*Kht*Kd 36.20 psf Khcc Comp & Clad: Table 6-3 Case 1 0.85 Qhcc.00256*V^2*I*Khcc*Kht*Kd 36.20 psf Wall Pressure Coefficients, Cp Surface Cp Windward Wall (See Figure 6.5.12.2.1 for Pressures) 0.8 Roof Pressure Coefficients, Cp Roof Area (sq. ft.) - Reduction Factor 1.00 Calculations for Wind Normal to 60 ft Face Cp Pressure (psf) Additional Runs may be req'd for other wind directions +GCpi -GCpi Leeward Walls (Wind Dir Normal to 60 ft wall) -0.50-21.90-8.87 Leeward Walls (Wind Dir Normal to 58 ft wall) -0.49-21.69-8.66 Side Walls -0.70-28.06-15.02 Overhang Bottom (Applicable on Windward only) 0.80 24.62 24.62 Roof - Wind Normal to Ridge (Theta<10) - for Wind Normal to 60 ft face Dist from Windward Edge: 0 ft to 16 ft - Max Cp -0.18-12.06 0.98 Dist from Windward Edge: 0 ft to 4 ft - Min Cp -0.90-34.21-21.18 Dist from Windward Edge: 4 ft to 8 ft - Min Cp -0.90-34.21-21.18 Dist from Windward Edge: 8 ft to 16 ft - Min Cp -0.50-21.90-8.87 Roof - Wind Parallel to Ridge (All Theta) - for Wind Normal to 58 ft face Dist from Windward Edge: 0 ft to 16 ft - Max Cp -0.18-12.06 0.98 Dist from Windward Edge: 0 ft to 4 ft - Min Cp -0.90-34.21-21.18 L Page No. 2 of 4

3/30/2011 WIND02 v2-03 Detailed Wind Load Design (Method 2) per ASCE 7-05 Dist from Windward Edge: 4 ft to 8 ft - Min Cp -0.90-34.21-21.18 Dist from Windward Edge: 8 ft to 16 ft - Min Cp -0.50-21.90-8.87 Dist from Windward Edge: > 16 ft -0.30-15.75-2.72 * Horizontal distance from windward edge Figure 6-10 - External Pressure Coefficients, GCpf Loads on Main Wind-Force Resisting Systems w/ Ht <= 60 ft Kh = 2.01*(15/zg)^(2/Alpha) = 0.85 Kht = Topographic factor (Fig 6-2) = 1.00 Qh = 0.00256*(V)^2*ImpFac*Kh*Kht*Kd = 36.20 Theta = Angle of Roof = 1.2 Deg Wind Pressures on Main Wind Force Resisting System Surface GCpf +GCpi -GCpi qh Min P Max P (psf) (psf) (psf) 1 0.40 0.18-0.18 36.20 7.97 21.00 2-0.69 0.18-0.18 36.20-31.50-18.46 3-0.37 0.18-0.18 36.20-19.91-6.88 4-0.29 0.18-0.18 36.20-17.02-3.98 5-0.45 0.18-0.18 36.20-22.81-9.78 6-0.45 0.18-0.18 36.20-22.81-9.78 1E 0.61 0.18-0.18 36.20 15.57 28.60 2E -1.07 0.18-0.18 36.20-45.26-32.22 3E -0.53 0.18-0.18 36.20-25.71-12.67 4E -0.43 0.18-0.18 36.20-22.08-9.05 * p = qh * (GCpf - GCpi) Figure 6-11 - External Pressure Coefficients, GCp Loads on Components and Cladding for Buildings w/ Ht <= 60 ft Page No. 3 of 4

3/30/2011 2a WIND02 v2-03 Detailed Wind Load Design (Method 2) per ASCE 7-05 2a 4a 3 2 3 2a 2 2 1 Theta 3 2 3 a W Note: The image shows a Gabled roof, but Fig 6-11 also applies to some monoslope cases a = 3.2 ==> 3.20 ft Double Click on any data entry line to receive a help Screen Component Width Span Area Zone GCp Wind Press (lb/ft^2) (ft) (ft) (ft^2) Max Min Max Min 0 -> 5 8.00 1 0.30-1.00 17.38-42.72 5 -> 10 8.00 2 0.30-1.80 17.38-71.69 10 -> 15 8.00 3 0.30-2.80 17.38-107.89 15 -> 20 8.00 4 0.90-0.99 39.10-42.36 20 -> 25 8.00 5 0.90-1.26 39.10-52.13 25 -> 35 8.00 1H 0.30-1.70 10.86-61.55 35 -> 50 8.00 2H 0.30-1.70 10.86-61.55 50 -> 70 8.00 3H 0.30-2.80 10.86-101.37 Note: * Enter Zone 1 through 5, or 1H through 3H for overhangs. Ht Page No. 4 of 4

Martinez Antonio EXHIBIT B ANCHOR/BASE SHEET FASTENER CALCULATIONS UNIVERSAL ENGINEERIG, INC. 12828 Buckland St., West Palm Beach, FL 33414 Tel: (561) 204-5000, Fax: (561) 204-1050, Web: www.uefirm.com, Email: ali@uefirm.com Certificate of Authorization: 26583

Universal Engineering, Inc. 12828 Buckland St., Wellington FL ANCHOR/BASE SHEET FASTENER SCHEDULE CALCULATION Sheathing transverse support spacing 4 Truss rafter spacing 2 effective area maximum(4*4/3, 4*2) effective area 8 ft^2 Zone 1, Field -42.72-42.72 Zone 2, Perimeter -71.69-71.69 Zone 3, Corner -107.89-107.89 total square 100 ft^2 Nail spacing of Side Lap 8 inch Nail spacing of center rows 8 inches Base sheet width 39.37 inches lap width 4 number of center rows in the field (given by NOA) 2 Number of center rows in the peremiter, adjusted 3 Number of center rows in the corner, adjusted 3 net width 35 2" from each side spacing between rows 12 inch Net length for 100 ft^2 33.9 ft Side lap 51 fasteners total fasteners of Center rows in the field 102 fasteners total 153 fasteners area/fastener 0.65 ft^2 Maximum design pressure 60 psf Fy, Fastener value =Maximum design pressure*served area 39.22 lb. Anchor/Base sheet fastener spacing (FS) to meet the design pressures in the elevated pressure zones of the roof Exterior Zone width = Perimeter, P RS, row spacing FS Corner, P RS, row spacing FS 3.20 feet 71.69 psf 9 inch 8 inch 107.89 psf 9 inch 5 inch 2464 PALM RD., 3/30/2011

Universal Engineering, Inc. 12828 Buckland St., Wellington FL ` 2464 PALM RD., 3/30/2011