EVERPURE HIGH FLOW CSR FILTER SYSTEMS SELECT A MOUNTING LOCATION INSTALLATION. Figure 1 Twin Figure 2 Triple Figure 3 Quad Figure 4 Quad Plus

Similar documents
Twin System Triple System Quad System

SElECTING A MOUNTING location OPERATING SPECIFICATIONS* * For individual cartridge specifications, refer to cartridge literature.

FlashGARD HP Reverse Osmosis Filtration System Model Number FSTMO75 Part Number

Installation, Operation, and Maintenance Manual

Vessel Installation and Operating Manual

Installation, Operation and Maintenance Manual

Installation and Operating Manual

Installation & Instruction Manual For Portable Series R.O. units:

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP

WATER HEATER THERMAL EXPANSION TANKS Owner s Manual. Safety Instructions Installation Maintenance Warranty. Models: 2-5 Gallon Capacity

Acid- Rite ph Adjustment System 2500 by Axiall, a Westlake Company

SSFU SUPER SPRAYFAST UNIVERSAL ADHESIVE APPLICATOR

OWNER S MANUAL. Table of Contents

Owners Manual Models: 075-AQF-CX. Aquatrol Backwashing Catalytic Carbon Filter. Visit us online at.

PERSONAL AIR BREATHING UNIT

REVERSE OSMOSIS WATER FILTRATION SYSTEM MODEL EWR 3035 INSTRUCTION MANUAL

BS Series Basket Strainer

REVERSE OSMOSIS WATER FILTRATION SYSTEM MODEL EWR 4075 INSTRUCTION MANUAL

3M Water Filtration Products

Accu-Tab Systems 2000 P Series by Axiall Corporation

Compact Triple Cabinet Outlet Station Model Installation and Operating Instructions

FLUSHMATE III FLUSHMATE FLUSHOMETER - TANK SYSTEM. Owner s Service Manual. 503 Series. 503 Series

Compact Triple Cabinet Outlet Station Model B Installation and Operating Instructions

ROPV R40 E Series User Manual

EVERPURE 7CLM CARTRIDGE CHLORAMINES SOLVED FOODSERVICE COMMERCIAL GRADE WATER FILTRATION

SERVICE MANUAL MODEL BA600AMST-S1 BREATHING AIR PANEL

Crystal Quest Voyager Series Inline Water Filter Systems INSTALLATION AND OPERATION GUIDE

Owner s Manual AMERICAN. LiquaGen 5 Stage (RO/DI) Aquarium Reef System. YEAR Y 1

SERVICE MANUAL MODEL BA200AMST-S1 BREATHING AIR PANEL

Iron Filter Installation / Operation Manual

PC1131 Electric Air Compressor

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50-P-Mini Portable Systems Outfitted with ABM-725 Monitor

G7S Hand Pump Owner s Manual

Jacuzzi. J-CQ420 Cartridge Filter Installation and Operating Instructions

Installation and Operation Guide MRS-100, MRS-225, MRS-100CC, MRS225CC Reverse Osmosis Mineral Reduction System For Foodservice Applications

Nitrogen Supply System

APCO ASU-SCAV & ASU-CAV SINGLE BODY COMBINATION AIR VALVES

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

Accu-Tab PowerBase 3070AT by Axiall Corporation

Accu-Tab Systems 1000 Series by Axiall Corporation

Instruction Sheet. SUPERSEDES: New EFFECTIVE: August 1, 2013

Saline C 6.0 Junction Box

Model B-1 Pipe Line Strainer 3, 4, 6 & 8 Inch (DN80, DN100, DN150 & DN200) 175 psi (12,1 bar) General Description. Technical Data

FLUSHMATE FLUSHOMETER - TANK SYSTEM. 501-A Series. Owner s Service Manual. 501-A Series

Yoke Block Instruction Manual

PC7-C Flowmeter O2/N2O Sedation Unit Instruction Manual

CHEMICAL INDUCTION KIT (Pt.No Issue 6, October 2015)

INSTALLATION INSTRUCTION

SERVICE MANUAL MODEL BA050BMST BREATHING AIR PANEL

SERVICE MANUAL MODEL BA200AA-S1 BREATHING AIR PANEL

Pure Water Power Purification System 4-Stage RODI Operations Manual

OPERATION / 3Z9305G 1:1 RATIO TRITON / Spray Packages / / / List of Models, page 2 / / / 100 psi (7 bar, 0.7 MPa) Maximum Working Pressure

PoolNaturally. Pure. Simple. Genius. Installation and Product Use Instructions In ground and above ground pools

4 and 8 Station PDS Control Installation & Operators Manual

MUELLER GAS. No-Blo Operations Using D-5. Drilling Machine. Reliable Connections. General Information 2

Model PSI Compressor with 3-Gallon Air Tank 12VDC

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

SASK-A-POLE OWNERS AND USERS MANUAL

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

Back Pressure Regulator

Manual. Bypass Feeder. Installation Maintenance Repair Manual. Chemical Addition and Filtering

Installation & Maintenance Manual. C2 & C3 Manifolds

MANUAL BE SERIES Test Benches

CART FOR CENTURION 1500+

Sterile Visual Flow Indicator

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

INDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES

OPERATOR'S MANUAL GRASS CATCHER GC-4D

GETZ EQUIPMENT INNOVATORS PART No. 4G59678 CARBON DIOXIDE MINI PUMP FOR EXTINGUISHER SERVICE (Revised )

OPERATOR'S MANUAL. MODEL GC-F4 Fabric Grass Catcher P/N 9055 GRASS CATCHER GC-F4. PART Rev.2 SC301G

INSTALLATION INSTRUCTION & OWNER S MANUAL

MN-800-TF REVERSE OSMOSIS TREATMENT SYSTEM OWNERS MANUAL

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

ULTRA-LIGHT DUTY ONBOARD AIR SYSTEM

Pressure Dump Valve Service Kit for Series 2300 Units

Installation Guide & Owner s Manual. Model V4700. Water Filtration for Dental & Medical Instrument Washing Equipment

Yoke Block Instruction Manual

Product Manual B-Safety ClassicLine & PremiumLine Emergency Eyewash and Eye/Face Wash Equipment

INSTALLATION MANUAL Matheson Tri-Gas Cabinet Enclosures

Type 1367 High-Pressure Instrument Supply System with Overpressure Protection

Oxygen Concentrator. Installation and Operation Manual. ClearWater Tech, LLC. Integrated Ozone Systems

FOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM

Portable oxygen concentrator

SERVICE MANUAL MODEL BA100BMST 100 SCFM PORTABLE AIR PANEL

INSTALLATION GUIDELINES

SERVICE MANUAL MODEL BA020AMST BREATHING AIR PANEL

Operating Instructions for BAIR22-6 AIR-POWERED CRIMPING TOOL

User Instruction Manual

SpectraPure PUMPED RO SYSTEMS (PSP) User s Manual for PSP-1500 Systems

INSTALLATION GUIDELINES

NGP-250/500 Nitrogen Generator Quick Start Guide

Purifier for Vinyl Lined Pools

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER FILTER DRYER

LUBRICATOR ASSEMBLY AND OPERATING INSTRUCTIONS

Model No Product Name Handpiece Only Complete System

Installation and Operation Guide MRS-600HE-II High Efficiency Reverse Osmosis System Mineral Reduction System For Foodservice Applications

MODEL 840 AIR HYDRAULIC PUMP INSTRUCTION

SANITIZERS SANITIZERS SANITIZERS FOR POOLS & SPAS

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

4-in-1 Professional Inflator Kit

Transcription:

EVERPURE HIGH FLOW CSR FILTER SYSTEMS Figure 1 Twin Figure 2 Triple Figure 3 Quad Figure 4 Quad Plus SELECT A MOUNTING LOCATION 1. Give consideration to the weight of the unit when operating (filled with water). Operating weights of Everpure High Flow CSR Systems are: Twin System - 45 lbs (20.4 kg) Triple System - 47 lbs (21.3 kg) Quad System - 49 lbs (22.2 kg) Quad Plus System - 49 lbs (25.2 kg) + separate surge/storage tank @ 60 lbs (27.2 kg) 2. The location should allow for (See Figures 1-8): Minimum clearance of 2-1 2" (6.4 cm) under the cartridge(s) so it can be lowered for removal and replacement. Adequate space for in and out water line connections. Be near a drain for flushing and near a 110V outlet if the optional Everguard Low Pressure Alarm is used. Additional mounting and floor space for the separate Everpure SR-X Feeder and surge/storage tank (Quad Plus). INSTALLATION 1. Use the predrilled mounting holes in the manifold bracket as guides. Mark and drill anchor holes. Mount securely. See Figures 5-8. 2. Shut off power to equipment. If system is an Everpure High Flow CSR Quad Plus (separate Everpure SR-X Feeder and surge/storage tank), proceed to step 4. 3. Connect outlet ports of High Flow system to equipment served per the instructions below. Always use NSF approved pipe dope or plumber tape at all connections. Use a backup wrench on all fittings while connecting to avoid stress on the system components. The cross fitting before the SR-X Feeder has a threaded outlet on top. Connect a minimum 1/2" I.D. line from this outlet to fountain beverage equipment. The cross fitting has a flushing valve installed on the bottom. Connect tubing to the flushing valve and run to drain. NOTE: Some municipal plumbing codes and good sanitary practices require an air gap at the drain termination point. Connect the outlet of the SR-X Feeder to the ice machine make-up water (not condenser water) line and coffee brewing equipment. Proceed to step 5. 4. For Everpure High Flow CSR Quad Plus System, connect outlet to equipment served per the instructions below. Always use a NSF approved pipe dope or plumber tape at all connections. Use a backup wrench on all fittings while connecting to avoid stress on the system components. Locate and mount the separate SR-X Feeder between the High Flow CSR system and the ice machine. Make-up water (not condenser water) line and coffee brewing equipment. A tee fitting is located in the system header before the surge tank isolation and flushing valve. Using minimum 1/2" I.D. line, connect the outlet of this tee to the fountain beverage and remote SR-X Feeder line. IMPORTANT: Install a tee in this service water line to separate the fountain water feed from the ice machine/coffee brewer water feed. In Massachusetts, a backflow preventer is required for this installation. FILTRATION & PROCESSING SOLUTIONS 1

Connect one branch of the service water tee to the fountain beverage equipment. Connect the other branch of the tee to the inlet of the SR-X Feeder. Connect the outlet of the SR-X Feeder to the ice machine make-up water (not condenser water) line and coffee brewing equipment. The surge tank isolation and flushing valve is located at the end of the system header. Using fittings and hose provided, connect one branch of the valve to the surge/storage tank. Connect a hose from the other (flushing) branch and run to drain. NOTE: Some municipal plumbing codes and good sanitary practices require an air gap at the drain termination point. 5. The surge/storage tank is pre-pressurized to 20 psi (1.4 bar). Check pressure and adjust as necessary. 6. Install a manual shut-off valve leading to the system for servicing and connect minimum 1/2" I.D. (3/4" for quad) water line to the system inlet. 7. The optional Everguard TM Low Pressure Alarm (LPA) consists of a pressure switch, audible/visual alarm box and a power adapter. It is designed to detect a fixed low pressure, approx. 20 psi (1.4 bar), condition as an indication of loss of system outlet pressure either due to an intentional shut-down or excess fouling of the water filters, thus indicating the need for filter cartridge change-out. If the system is equipped with the LPA, follow these steps: Determine location of a convenient 110 VAC outlet to plug in the LPA power adapter. Remove the protective rubber cap from the pressure switch installed in the system header assembly. Insert the wires from the LPA unit through the cap and connect them to the terminals on the pressure switch. Either wire can be connected to either terminal. Replace the cap. Plug the LPA power adapter into an outlet. The audible alarm should activate. Push the reset switch to silence. Unplug the LPA unit. 8. Shut off the system inlet valve located on the inlet of the prefilter head. 9. Check to be sure the o-ring on the prefilter housing is sufficiently lubricated. Use a good grade of silicone lubricant, if needed. Position the Everpure EC210 prefilter cartridge on guide seat in the bottom of the bowl. Then thread the bowl into the head by hand. Use a sump wrench to snug the bowl onto the head. 10. Install only genuine Everpure carbon filter cartridge(s) into the filter head(s) following directions on the cartridge label or as shown in the Cartridge Change illustrations. Install the Everpure SS-10 Scale Inhibitor cartridge into the Everpure SR-X housing. 11. Turn on inlet water to the filter system and check for leaks. 12. Open the flushing valve and flush the cartridge(s) by running water through at full force for five (5) minutes. This will set the filtering media and purge any air and fines, insuring maximum filter life. See illustrations. 13. After flushing, close the flushing valve, turn on power to equipment and plug the LPA (if so equipped) into the electrical outlet. The system is ready for operation. Check for compliance with state and local laws and regulations. Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts. For installations in Massachusetts, the Commonwealth of Massachusetts Plumbing Code 248 CMR shall be adhered to. Consult your licensed plumber for installation of the system. This system and its installation must comply with state and local regulations. DIMENSIONS 30" 25.80" FOUNTAIN FOUNTAIN ICE MACHINE/ COFFEE ICE MACHINE/ COFFEE 25.59" 25.59" Figure 5 Twin Figure 6 Triple 2

34" 31.38" INSERT TEE FITTING. ONE TO FOUNTAIN, ONE TO SRX. ICE MACHINE/ COFFEE ICE MACHINE/ COFFEE 25.69" Figure 7 Quad Figure 8 Quad Plus CARTRIDGE CHANGE DETERMINATION Replace the prefilter cartridge whenever it becomes excessively dirty (observed visually or by flow restriction). Follow the change instructions provided with the cartridge. Replace carbon filter cartridges when capacity is reached or when flow becomes inadequate, but at least annually. All carbon filter cartridges on multiple cartridge systems should be changed at the same time. Change the Everpure SS-10 cartridge when product level in the cartridge drops below 1/2" from the bottom of the bowl. The system pressure gauge or optional Everguard Low Pressure Alarm (LPA) provides a quick, simple means of determining when the filter cartridge(s) should be checked. Installed on the system outlet manifold, the gauge or LPA can be used to monitor both dynamic (flowing) and static (line) pressure. The cartridge(s) should be changed when the pressure gauge is in the red area while equipment is in operation, and yet the needle shows adequate line pressure between cycles. Observe the needle during the next equipment on cycle. If the needle registers adequate pressure, it can be assumed that the temporary low-pressure condition was caused by a brief power failure or other incoming pressure disruption. If the low pressure condition is not due to an external condition, check/change the prefilter first. If the low pressure condition is still not corrected, change the carbon filter cartridges. FLUSHING For maximum life, all carbon filter cartridges must be flushed for five (5) minutes at full flow before use. ALL NEW CARTRIDGES MUST BE FLUSHED AFTER EACH CARTRIDGE CHANGE BEFORE BEING PUT INTO SERVICE! If the cartridges are new, have been properly flushed and both needle and follower register inadequate pressure, or the LPA is sounding, you may be experiencing inadequate water pressure or some restriction may exist in the inlet water line. In either case, the incoming water pressure must be improved to receive optimum filter life. COMPLETE CARTRIDGE CHANGE INSTRUCTIONS CAN BE FOUND ON THE FILTER CARTRIDGE LABEL. Not for residential use. For food service applications only. REPLACEMENT PARTS Contact your local Pentair Everpure dealer for filter cartridges or system replacement parts. DESCRIPTION Inlet/Outlet Pressure Gauge Inlet/Flushing Valve O-ring for Prefilter or SR-X Prefilter Bowl SR-X Bowl LPA Pressure Switch Wrench PART NUMBER EV3114-09 EV3114-07 EV3112-40 EV3112-38 EV3112-39 EV3016-41 EV3112-41 3

PRESSURE GAUGES Low Inlet Pressure Adequate Inlet Pressure Low Outlet Pressure Adequate Outlet Pressure CARTRIDGE CHANGE PROCEDURE E-Series Prefilter Cartridge Change 3. Clean bowl with filtered water only; NO SPECIAL CLEANERS. 1. Shut off power to equipment. Shut off inlet water ahead of system. 2. Push red relief valve. Unscrew bowl. Remove prefilter cartridge. 4. Feel head o-ring. If dry, lubricate with high quality silicone lubricant. 5. Install new prefilter cartridge in bowl. Hand tighten bowl onto head. 6. Turn on water. Turn on power to equipment. Flushing Everpure Carbon Filter Cartridge Change 1. Shut off power to equipment. Shut off inlet water ahead of system. 2. Open flushing valve to relieve pressure. 3. Hold head firmly and push upward. Turn cartridge to left until it stops. 4. Pull cartridge downward and out of head. 5. Hold head firmly. Align cartridge lug with label. Insert new cartridge firmly into head. 6. Turn cartridge right 90 until rotation stops. 7. Repeat steps 3-6 for remaining cartridges. 8. With flushing valve fully open, open inlet water at full force for five minutes. Close flushing valve. 9. Turn on power to equipment 8. Turn on water. SR-X Feeder Cartridge Change 1. Shut off power to equipment. Shut off inlet water ahead of system. 2. Press red pressure relief button on head. 3. Unscrew bowl. 4. Remove old cartridge. 5. Feel bowl o-ring; if dry, lubricate with silicone lubricant. 6. Install new SS-10 cartridge into head. 7. Hand tighten bowl into head. 9. Press red pressure relief button until water comes out of valve port. 10. Turn on power to equipment. 4

OPERATING SPECIFICATIONS* COMBINED MODEL NAME REPLACEMENT CARTRIDGE FLOW RATE CAPACITY GPM LPM GALLONS LITRES High Flow CSR Twin - MC MC 3.3 12.5 18,000 68,000 High Flow CSR Twin - MC 2 MC 2 3.3 12.5 18,000 68,000 High Flow CSR Twin - XC XC 3.3 12.5 18,000 68,000 High Flow CSR Twin - XC 2 XC 2 3.3 12.5 18,000 68,000 High Flow CSR Twin - 4CB5 4CB5 3.3 12.5 12,000 45,400 High Flow CSR Twin - 7CB5 7CB5 5.0 18.9 20,000 75,700 High Flow CSR Triple - MC MC 5.0 18.9 27,000 102,000 High Flow CSR Triple - MC 2 MC 2 5.0 18.9 27,000 102,000 High Flow CSR Triple - XC XC 5.0 18.9 36,000 136,000 High Flow CSR Triple - XC 2 XC 2 5.0 18.9 36,000 136,000 High Flow CSR Triple - 4CB5 4CB5 5.0 18.9 18,000 68,000 High Flow CSR Triple - 7CB5 7CB5 7.5 28.5 30,000 113,550 High Flow CSR Quad - MC MC 6.6 25.2 36,000 136,000 High Flow CSR Quad - MC 2 MC 2 6.6 25.2 36,000 136,000 High Flow CSR Quad Plus - XC XC 6.6 25.2 48,000 181,600 High Flow CSR Quad Plus - XC 2 XC 2 6.6 25.2 48,000 181,600 * For individual cartridge specifications, refer to cartridge literature. Temperature: 35-100 F (2-38 C) Pressure: 10-125 psi (0.7-8.6 bar), non-shock For cold water use only. System Tested and Certified by NSF International against NSF/ANSI Standard 42 and 53 for the reduction of: Standard No. 42 Aesthetic Effects Bacteriostatic Effects (MC 2 and XC 2 only) Chemical Reduction Taste and Odor Chlorine Mechanical Filtration Nominal Particulate Class I Standard No. 53 Health Effects Mechanical Filtration Cyst (MC, MC 2, XC, XC 2 only) Asbestos (MC, MC 2 only) The term bacteriostatic indicates that the system limits the passage or growth of bacteria that may already exist in the incoming water. It does not mean that the water leaving the system is safer to drink than the water entering the system. 5

NOTES 6

NOTES 7

LIMITED WARRANTY COMMERCIAL WATER TREATMENT EQUIPMENT You have just purchased one of the finest water treatment units made. As an expression of confidence in this product, Pentair Filtration Solutions, LLC ( PFS ) offers the following product warranty. This product is warranted against material defects in materials and workmanship to the original end-user when installed in accordance with the PFS specifications. The warranty period commences on the date of purchase and is administered as follows: For a period of ONE YEAR For a period of FIVE YEARS Replaceable elements (i.e., filter & water treatment cartridges)* The entire system (excluding replaceable elements) The unit must be used in operating conditions that conform to PFS s recommended guidelines. This warranty will not apply if the unit has been modified, repaired or altered by someone not authorized by PFS. If a part described above is found to have a material defect in materials or workmanship within the specified warranty period, you should notify Pentair Everpure technical service at the phone number listed below. Any part found materially defective within the terms of this warranty will be repaired or replaced (at PFS s discretion) by your local dealer or Pentair Everpure technical service. You pay only freight from our factory and local dealer charges. Any item repaired or replaced pursuant to this warranty will be covered under the original warranty terms of the system. PFS is not responsible for damage caused by accident, fire, flood, freezing, Act of God, misuse, misapplication, neglect, oxidizing agents (such as chlorine, ozone, chloramines and other related components), alteration, installation or operation contrary to our printed instructions, or by the use of accessories or components which do not meet PFS s specifications. Refer to the specifications section in the Installation and Operating manual for approved application parameters. Our product performance specifications are furnished with each water treatment unit. TO THE EXTENT PERMITTED BY LAW, EVERPURE DISCLAIMS ALL IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PARTICULAR PURPOSE; TO THE EXTENT REQUIRED BY LAW, ANY SUCH IMPLIED WARRANTIES ARE LIMITED IN DURATION TO THE PERIOD SPECIFIED ABOVE FOR THE ENTIRE WATER TREATMENT UNIT. As a manufacturer, we do not know the characteristics of your water supply or the purpose for which you are purchasing this product. The quality of water supplies may vary seasonally or over a period of time, and your water usage rate may vary as well. Water characteristics can also differ considerably if this product is moved to a new location. For these reasons, we assume no liability for the determination of the proper equipment necessary to meet your requirements, and we do not authorize others to assume such obligations for us. Further, we assume no liability and extend no warranties, express or implied, for the use of this product with a nonpotable water source or a water source which does not meet the conditions for use described in the owner s guide or performance data sheet for this product. OUR OBLIGATIONS UNDER THIS WARRANTY ARE LIMITED TO THE REPAIR OR REPLACEMENT (AT PFS S DISCRETION) OF THE FAILED PARTS OF THE WATER TREATMENT UNIT, AND WE ASSUME NO LIABILITY WHATSOEVER FOR DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, SPECIAL, GENERAL OR OTHER DAMAGES. Some states do not allow the exclusion of implied warranties or limitations on how long an implied warranty lasts, so the above limitation may not apply to you. Similarly, some states do not allow the exclusion of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. *Warranty applies to material defects in materials & workmanship only. EPA Est. No. 002623-IL-002 FILTRATION & PROCESSING SOLUTIONS EVERPURE-SHURFLO WORLD HEADQUARTERS, 1040 MUIRFIELD DRIVE, HANOVER PARK, IL 60133 USA WWW.EVERPURE.COM 800.942.1153 MAIN (US ONLY) 800.942.1153 (US ONLY) 630.307.3000 MAIN 630.307.3030 FAX CSEVERPURE@PENTAIR.COM EMAIL PENTAIR AUSTALIA/NEW ZEALAND, 1-21 MONASH DRIVE, DANDENONG SOUTH, VIC 3175, AUSTRALIA 1300.576.190 TEL AU.EVERPURE@PENTAIR.COM EMAIL EVERPURE-SHURFLO CHINA, 21F CLOUD 9 PLAZA, NO 1118, SHANGHAI, 200052, CHINA 86.21.3211.4588 TEL 86.21.3211.4580 FAX CHINA.WATER@PENTAIR.COM EMAIL EVERPURE-SHURFLO INDIA, GREEN BOULEVARD, B-9/A, 7TH FLOOR - TOWER B SECTOR 62, NOIDA - 201301 91.120.419.9444 TEL 91.120.419.9400 FAX INDIACUSTOMER@PENTAIR.COM EMAIL EVERPURE-SHURFLO EUROPE, PENTAIR WATER BELGIUM BVBA, INDUSTRIEPARK WOLFSTEE, TOEKOMSTLAAN, 30 B-2200 HERENTALS, BELGIUM +32.(0).14.283.500 TEL +32.(0).14.283.505 FAX SALES@EVERPURE-EUROPE.COM EMAIL EVERPURE-SHURFLO JAPAN INC., HASHIMOTO MN BLDG. 7F, 3-25-1 HASHIMOTO, MIDORI-KU, SAGAMIHARA-SHI KANAGAWA 252-0143, JAPAN 81.(0)42.775.3011 TEL 81.(0)42.775.3015 FAX INFO@EVERPURE.CO.JP EMAIL EVERPURE-SHURFLO SOUTHEAST ASIA, 390 HAVELOCK ROAD, #04-01, KING S CENTRE, SINGAPORE 169662 65.6795.2213 TEL FAX: 65.6795.2219 FAX CSEVERPURE@PENTAIR.COM EMAIL All Pentair trademarks and logos are owned by Pentair, Inc. or its affiliates. All other registered and unregistered trademarks and logos are the property of their respective owners. Because we are continuously improving our products and services, Pentair reserves the right to change specifications without prior notice. Pentair is an equal opportunity employer. 2014 Pentair Filtration Solutions, LLC. All Rights Reserved. EV3112-78 Rev F MY14