MB60 Industrial Pressure Transmitter Features Extreme Impact and vibration resistance, anti-overload, anti-corrosion; Digital compensation, wider operating ambient temperature range; High accuracy, low power dissipation, small volume, good long-term stability; Protecting from pulsating pressure design, water hammereffect and cavitation resistance. Introduction MB60 Pressure Transmitter adopts MEMS and durable thin film sputtered technology which avoids the impact caused by factors, such as temperature, humidity, mechanical fatigue, medium, etc. MB60 provides excellent long-term stability in applications producing frequent pressure cycles. Autorun temperature compensate digital circuit inside, supports super performance on anti-jamming and wider operating ambient temperature range for critical application. Specification Pressure range (MPa) 2 5 6 0 20 40 60 Pressure range (Bar) 20 50 60 00 200 400 600 Pressure range (Psi) 300 700 900 2k 4k 8k Output signal Propotional output; (4~20)mA Excitation Over pressure DC;(2~30)VDC,(Antisurge,30V ), 24VDC(typ.) 200%F.S. Burst pressure 300%F.S. Shock 0~500Hz 25g Impact 50 g ms
Accuracy Temperature coefficient Protection Grade Insulation resistance Medium temperature Ambient temperature Storage temperature Measuring medium Durability Industrial Pressure Transmitter ± 0.5%FS ± 3%FS IP67 250 MΩ/250V (-40~25) (-40~85) (-40~25) Liquid or gas which are compatible with 304SS 0 milions times,(0~00)%fs Electrical connection Packard connector M2X connector Direct cable (4~20)mA (4~20)mA Red (2~30)V (2~30)V (4~20)mA (2~30)V 3 Current output 3 Current output Yellow Current output Red 2 GND 2 GND Green GND 3 Voltage output 3 Voltage output Yellow Voltage output
Outline structure (Unit:mm)
Order Guide MB60 Industrial Pressure Transmitter 0~60MPa Pressure range (Unit Psi,Bar,Kpa,Mpa ) Code A G S Pressure reference Absolute pressure Gauge pressure Sealed gauge pressure Code Excitation V 24V V2 2V V3 others (please specify) Code Output signal C DC/ C2 24VDC/(4~20)mA C3 Customized Code Pressure connection G G3/8 G2 G/4 G3 M6X.5 G4 Customized Code Electrical connection J PACKARD J2 M2X EN60947-5-2 J3 Direct cable J4 Customized Code Accuracy P 0.%FS P2 0.25%FS P3 0.5%FS S Others, Please note MB60 MPa G V B G J P S Order Note. The material of measuring medium should be compatible with the stainless steel. If it is corrosive, pls specify its material in detail. 2. Please note in the order if you need zero pressure as negative pressure.
3. Please note it in detail if your application environment is critical or the elements which may influence the pressure transmitter normal operation existed. 4. The structure and demension of the pressure transmitter can be used for most of the application occasions, if your application space is too small or having other requirements to the transmitters, please specify it in detail. 5. All specifications are subject to change. Contact Gaohua for specifications and engineering drawings that are critical to your application. Drawings contained in this document are for reference only.