Rigel 601 CHECKBOX. Instruction Manual. 348A551 Issue 2.0. April Seaward Electronic Ltd. Issue 2.0

Similar documents
! Warning, refer to accompanying documents.

Leakage Current Testing Is it right for your application?

The definition of a competent person given in the Electricity at Work Regulations 1989 (EWR) is as follows:

C&G Level 3 Award in the Periodic Inspection, Testing and Certification of Electrical Installations

Operating Manual VSA100A. tina29e1 ( )

Digital Melting Point Apparatus

New AQF Filter Polymer Filtration System

Guidelines to the standard IEC60601

Gas density monitor With integrated transmitter Model GDM-100-TI

Solenoid gas valve. The solenoid gas valve is also applicable as a main gas valve Pilot gas valve for forced draft burners

Inspection and Testing

1 METRON MANIPULATION TABLES - WARRANTY STATEMENT

Operating Instructions Temperature Measuring System MF420-5T-100

3G Operating instructions. Digital Purge Gas Valve 3G Type: Document no.: D0001 Version: 01. July 2011/Rev.

Further technical information is available on

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

Operating Instructions for Intrinsically Safe Pressure Transmitters Series DMG/******** for Hazardous Application in Coal Mining Industry

Mounting instructions. Strain transducer SLB-700A. B 26.SLB700A.10 e

OEM Manual. MODEL ½ Digit DRUM SCALE

Norrsken Family Booklet

High-performance submersible pressure transmitter For level measurement Model LH-10

CHAPTER 2: ELECTRICAL SAFETY

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 09.14

C&G 2395 Exam Paper June Section A-All questions carry equal marks. Answer all three questions. Show all calculations.

* * Data Sheet and Operating Manual. Digital manometer ME01 ## # 87 # HL S#### Dust explosion protection Zone 22.

OEM Manual MODEL 2305 ECONOMICAL DIGITAL SINGLE CYLINDER SCALE

Type 0404 / /2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation

12V MINI AIR COMPRESSOR

PLEASE READ CAREFULLY BEFORE INSTALLING OR USING MEGA POOL SAVER MPS 1100

User s Guide Temperature Sensor Converter TSC-599

KMW3000C. User Manual. Water Chiller for Xcalibur and Gemini systems. Version 1.6, September 2010

BA307C & BA308C Intrinsically safe loop-powered 3½ digit panel mounting indicators issue 9

ELECTRICAL (COMPREHENSIVE) SAFETY PROGRAM REGULATORY STANDARD: OSHA - 29 CFR CFR , ,

KERN EG/EW Version /02

Magnetic level switch type MR783 Instruction Manual

Supplementary Operator s Manual 42/24-14 EN Rev. 3

OxyScan Graphic. Operating Instructions. UMS Micro-oxygen sensor 501. Microprocessor instrument

Installation Procedure Esco Miri Multi-Room Incubator

D10S/D20S Wall/Post Mount Inflator Quick Start Manual

GasSense NDIR User Manual

High-performance submersible pressure transmitter For level measurement Model LH-10

Model PDT Dewpoint Transmitter

Technical Information Conducal CLY421

Installation, Operation & Maintenance Instructions

Code of Practice for the Inspection and Testing of Portable Electrical Equipment (PAT)

METROTEC GSM. Type GSM. Oxygen measurement and control unit. *** Version 1.6 ***

Analysis of Pressure Rise During Internal Arc Faults in Switchgear

Electrical Shore Connections

PORTABLE WORK LIGHT MODEL NO: CL6FS OPERATION INSTRUCTIONS PART NO: GC0315

USER MANUAL. JET TST and JET TST S.

Instruction Manual BA90 Precision Barometer

SIL Safety Manual. ULTRAMAT 6 Gas Analyzer for the Determination of IR-Absorbing Gases. Supplement to instruction manual ULTRAMAT 6 and OXYMAT 6

URC Voltage Sensor SEN-VOLT for use with MRX units containing sensor ports

Automatic Control Unit. Controlmatic E.2. Type Series Booklet

Operating Instructions Part No

Equipment Accuracy / Selection

Ground Fault Circuit Interrupter(GFCI) Policy

OSAT Series. Intrinsically Safe Infrared Temperature Sensor Operator's Guide

Safety Manual VEGAVIB series 60

ES18 Security Theory/Regulations Answer Schedule

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

Installation, Operation, & Maintenance Manual. MODEL: Watlow Controller P53 Direct, P53 Remote

Solaris Nitrogen. Installation Guide. Solaris Nitrogen Installation Guide Rev 1 PN IG /09/16

Inspection and Testing Pocket Notes

DX 3 RCDs. Technical data Nature and consequences of electrical risks Direct and indirect contact. Direct contacts

Operating instructions Installation instructions To be kept in the vehicle!

Budget Range Operators Handbook

MAKING ELECTRICAL A GUIDE ON HOW TO INSPECT AND TEST PORTABLE APPLIANCES SAFELY AND EFFECTIVELY

Operating instructions for variable area flow meter with needle valve. Model: UVR/UTR

12V Mini Air Compressor

Safety. Operating instructions Solenoid valve for gas VG 10/15 VG 65 DANGER. Contents WARNING CAUTION. Changes to edition 11.14

Instruction Manual Contact Pressure Vacuum Gauge

RTD temperature probes

MANUAL DIRECT PURGE OPTION. UNION Instruments GmbH CWD2005 PLUS. General information, safety standards and regulations for direct purge option

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

Types and approvals. Page 1/6. Data Sheet

Operator s Manual 701 Test Kit for Static Control Surfaces (Megohmmeter)

GAS FUEL VALVE FORM AGV5 OM 8-03

Manual Power relay SR853

Tightness controls TC 1 3 and TC 4

Datasheet: K-30 ASCII Sensor

Automatic Valve Proving Control

MIE Medical Research Ltd Digital Analyser Pinch/Grip Instruction Manual

Feltest AirSpeed/2 Instruction manual

AMT-Ex Dewpoint Transmitter

e.do Gripper Safety requirements, technical features and assembly and integration instructions

MODELS (2 foot Version) (4 foot Version)

Operating Instructions

VERTICAL AIR COMPRESSORS

ATEX, IECEx and MET (Class I, Division 1) Safety Instructions icam502

QPL... Pressure Switches. Siemens Building Technologies HVAC Products

LYMPHA PRESS MANUFACTURED BY MEGO AFEK IMPORTED BY LYMPHA PRESS USA, Ltd. USERS MANUAL LYMPHA PRESS MODEL 201-M

SC505 Sof Care Inflator. Operating Instructions and Service Manual

AR740 RPS Redundant Power Supply Quick Install Guide

PECIMEN IMM6. Minor Electrical Installation Works Certificates. Amd 3: In accordance with BS 7671

EC214 EC215 - EC215R Bench Conductivity Meters

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

Pressure Measurement Single-range transmitters for general applications

C&G 2395 Exam Paper April Section A - All questions carry equal marks. Answer all three questions. Show all calculations.

Installation and Operation Manual

Transcription:

Rigel 601 CHECKBOX Instruction Manual 348A551 Issue 2.0 April 2006 2006 Seaward Electronic Ltd. Issue 2.0

Limited Warranty & Limitation of Liability Rigel Medical guarantees this product for a period of 1 year. The period of warranty will be effective at the day of delivery. Issue 2.0 April 2006 2006 Seaward Electronic Ltd. All rights reserved. Nothing from this edition may be multiplied, or made public in any form or manner, either electronically, mechanically, by photocopying, recording, or in any manner, without prior written consent from SEAWARD Electronic Limited. This also applies to accompanying drawings and diagrams. Due to a policy of continuous development SEAWARD Electronic Limited reserves the right to alter the equipment specification and description outlined in this publication without prior notice and no part of this publication shall be deemed to be part of any contract for the equipment unless specifically referred to as an inclusion within such contract. - 2 -

CONTENTS DECLARATION OF CONFORMITY 4 BEFORE STARTING 5 SAFETY NOTICE 6 INTRODUCTION 7 CONNECTIONS 8 USING THE CHECKBOX 601 9 VERIFYING EARTH BOND TEST MEASUREMENT 10 VERIFYING INSULATION TEST MEASUREMENT 10 VERIFYING EARTH LEAKAGE TEST MEASUREMENT 10 VERIFYING ENCLOSURE LEAKAGE TEST MEASUREMENT 10 VERIFYING PATIENT LEAKAGE TEST MEASUREMENT 11 VERIFYING F-TYPE LEAKAGE TEST MEASUREMENT 12 TABLE OF LEAKAGE TEST VALUES 13 SPECIFICATION 14 ENVIRONMENTAL SPECIFICATION 14 MAINTENANCE 14 WARRANTY & REPAIR 15 APPENDIX 1 16-3 -

Declaration of Conformity The Rigel 601 Electrical Medical Safety Analyser Checker Manufactured by: Seaward Electronic Ltd, Bracken Hill, South West Industrial Estate Peterlee, County Durham, SR8 2SW, England Millennium Statement This product is Millennium compliant, and conforms fully to the document BSI DISC PD2000-1. Statement of Conformity Based on test results using appropriate standards, the product conforms with Electromagnetic Compatibility Directive 89/336/EEC and Low Voltage Directive 73/23/EEC Standards used: EN 60601-1 (1990) Medical Electrical Equipment. General Requirements for Safety EN 61010-1 (1993) Safety Requirements for Electrical Equipment for Measurement, Control, and Laboratory Use EN 50081-1 (1992) Electromagnetic Compatibility. Generic Emission Standard: EN55022 Class B EN 50082-1 (1992) Electromagnetic Compatibility. Generic Immunity Standard: IEC1000-4-2, -4-3, -4-4, -4-5 The tests have been performed in a typical configuration. This Conformity is indicated by the symbol Européenne, i.e. Conformité - 4 -

Before Starting Upon receipt of your Rigel-601 Checkbox:- 1. Check that all the component parts are present:- Rigel 601 Checkbox Unit Instruction manual Function Earth Lead (green) with Crocodile clip Calibration Certificate 2. Read the operating instructions fully before conducting any tests. 3. Contact Rigel Medical if you require training on this Analyser or any other Rigel Medical product. Courses can be arranged at Rigel Medical, or at customer premises. 4. Rigel Medical can be contacted at: P/A Seaward Electronic Ltd Bracken Hill South West Industrial Estate Peterlee, Co. Durham SR8 2SW, England Tel : +44 (0)191 587 8730 Fax: +44 (0)191 586 0227 sales@rigelmedical.com calibration@seaward.co.uk www.rigelmedical.com - 5 -

SAFETY NOTICE READ INSTRUCTION BEFORE USE Due to the potential hazards associated with any electrical circuit it is important that the user is familiar with the instructions covering the capabilities and operation of this instrument. The user should ensure that all reasonable safety precautions are followed and if any doubt exists should seek advice before proceeding. This product is designed for use by suitably trained competent personnel and should be operated strictly in accordance with the instructions supplied. Failure to comply with these instructions may expose the user to electrical hazard. Check the unit regularly for damage to cable or casing. IMPORTANT! NEVER PLUG THE RIGEL 601 CHECKBOX, OR ANY OF ITS CONNECTIONS, DIRECTLY INTO THE MAINS SUPPLY. DO NOT TOUCH THE RIGEL 601 CHECKBOX WHILE CARRYING OUT TESTS. Important, follow the documentation! This symbol indicates that the operating instructions must be adhered to in order to avoid danger. Warning of electrical danger! Indicates instructions must be followed to avoid danger to persons. - 6 -

Introduction The Rigel 601 Checkbox has been designed to provide an accurate and effective means of checking the accuracy of most IEC 60601-1 Electrical Medical Safety Analysers (from now on referred to as EMSA). With the ability to generate both AC and DC leakage currents as well offering dedicated F-type circuitry, the Rigel 601 is able to provide traceable values for Earth Leakage, Enclosure Leakage, Patient Leakage and Patient Leakage Mains on Applied Parts. In addition, the Rigel 601 is able to provide a series of highly accurate resistance values to check the linearity of the Earth Bond and Insulation measuring circuits. Dedicated switch positions provide individual PASS and FAIL values for B/BF and CF limits as per IEC 60601-1. With the use of high precision resistors, the Rigel 601 has a recommended calibration interval of 36 months, providing a stable and accurate reference for all IEC 60601-1 safety analysers for years to come. The Rigel 601 provides separate PASS / FAIL limits for B/BF and CF equipment as per IEC 60601-1 (See tabel T1). A dedicate switch provides either a PASS or FAIL result by generating leakage at 15% under the IEC 60601 limit (PASS) or 15% over the IEC 60601 limit (FAIL) The Rigel 601 Checkbox is not intended to replace the annual calibration should your quality assurance procedure require it. - 7 -

Connections Figure 1 Connections Key (1) Applied parts connections (2) B-BF / CF switch (3) PASS / FAIL switch (4) Supply monitor outlet (5) Earth Bond connections (see calibration certificate for values) (6) Insulation Test connections (7) Enclosure Leakage connection (8) Power input indicator (9) F-type Leakage Test indicator - 8 -

Using the Rigel 601 Checkbox The Rigel 601 Checkbox is NOT designed to be directly connected a mains outlet. Doing so might cause a danger to the operator or damage the Checkbox. Diagram 1 shows the correct connection of the Rigel 601 Checkbox. To connect the Rigel 601 Checkbox to your Electrical Medical Safety Analyser, plus the power cable into the EUT / DUT socket of the EMSA. In addition, connect the Function Earth Lead (green cable) to an external earth conductor. By not connecting the Green Earth lead, the simulated leakage values might be incorrect. Connect the Earthbond test lead to one of the test points R1-R3 (5). Connect your test lead for Enclosure Leakage to terminal (7). In case Patient Connections are required, use up to 11 connections provided under Applied Parts (1). Note that the Rigel 601 Checkbox uses an internal Isolation Transformer. For this reason, the Checkbox will not produce any correct leakage values when used under Open Neutral single fault condition. Diagram 1-9 -

Verifying the Earth Bond Test Measurement a) Connect the Earth Bond Probe to the required Earth Continuity test point (See Fig. 1 (5)). b) Carry out the Earth Bond Test. The reading on the EMSA should correspond with the value written beneath the Test Point within the specified limits for the particular EMSA. c) Repeat the procedure for each of the Earth Continuity connections, as appropriate, to check for accuracy at each of the critical values. Verifying the Insulation Test Measurement a) Connect the Test Probe (Earth Bond Probe on Rigel EMSA) to the required test point on the Checkbox (See Fig. 1 (6)). b) Perform the Insulation Test and confirm that the Insulation reading corresponds with the value of the test point and is within the specified limits for the particular EMSA. c) Repeat the procedure for each of the Insulation Test connections, as appropriate, to check for accuracy at each of the critical values. Verifying the Earth Leakage Test Measurement a) Plug the appropriate Test Probe into the Enclosure Leakage test point (Fig. 1 (7)). b) Plug a meter into the supply monitor sockets for accurate Line Voltage Indication (Fig. 1 (4)). c) Set the PASS / FAIL switch to PASS. d) Perform an Earth Leakage Test. e) The measured value should correspond to the -15% EARTH value scaled to reflect the actual mains test voltage as described in Table 1 and the equation shown beneath it, or refer to Appendix 1 and cross reference the test data from the column headed with nearest voltage level. f) Once complete, set the PASS / FAIL switch to FAIL. g) Carry out another Earth Leakage Test. h) The measured value should correspond to the +15% EARTH value scaled to reflect the actual mains test voltage as described in Table 1 and the equation shown beneath it, or refer to Appendix 1 and cross reference the test data from the column headed with nearest voltage level. - 10 -

Verifying the Enclosure Leakage Test Measurement a) Plug the appropriate Test Probe into the Enclosure Leakage test point. b) Plug a meter into the supply monitor sockets. c) Set the PASS / FAIL switch to PASS. d) Perform an Enclosure Leakage Test. e) The measured value should correspond to the -15% ENCLOSURE value scaled to reflect the actual mains test voltage as described in Table 1 and the equation shown beneath it, or refer to Appendix 1 and cross reference the test data from the column headed with nearest voltage level. f) Once complete, set the PASS / FAIL switch to FAIL. g) Carry out another Enclosure Leakage Test. h) The measured value should correspond to the +15% ENCLOSURE value scaled to reflect the actual mains test voltage as described in Table 1 and the equation shown beneath it, or refer to Appendix 1 and cross reference the test data from the column headed with nearest voltage level. Verifying the Patient Leakage Test Measurement a) Plug a meter into the supply monitor sockets. b) Set the PASS / FAIL switch to PASS. c) Set the CF / B-BF switch to B-BF. d) Perform a Patient Leakage Test with the EMSA set to B or BF - if applicable. e) The measured value should correspond to the -15% PATIENT LEAKAGE AC (B-BF) and -50% PATIENT LEAKAGE DC values scaled to reflect the actual mains test voltage as described in Table 1 and the equation shown beneath it, or refer to Appendix 1 and cross reference the test data from the column headed with nearest voltage level. f) Once complete, set the PASS / FAIL switch to FAIL. g) Carry out another Patient Leakage Test with the EMSA set to B or BF - if applicable. h) The measured value should correspond to the +15% PATIENT LEAKAGE AC (B-BF) and +50% PATIENT LEAKAGE DC values scaled to reflect the actual mains test voltage as described in Table 1 and the equation shown beneath it, or refer to Appendix 1 and cross reference the test data from the column headed with nearest voltage level. - 11 -

i) If necessary, repeat the Patient Leakage Tests for separate measurement of AC and DC readings. j) Set the PASS / FAIL switch to PASS. k) Set the CF / B-BF switch to CF. l) Perform a Patient Leakage Test with the EMSA set to CF - if applicable. m) The measured value should correspond to the -15% PATIENT LEAKAGE AC (CF) and -50% PATIENT LEAKAGE DC values scaled to reflect the actual mains test voltage as described in Table 1 and the equation shown beneath it, or refer to Appendix 1 and cross reference the test data from the column headed with nearest voltage level. n) Once complete, set the PASS / FAIL switch to FAIL. o) Carry out another Patient Leakage Test with the EMSA set to CF - if applicable. p) The measured value should correspond to the +15% PATIENT LEAKAGE AC (CF) and +50% PATIENT LEAKAGE DC values scaled to reflect the actual mains test voltage as described in Table 1 and the equation shown beneath it, or refer to Appendix 1 and cross reference the test data from the column headed with nearest voltage level. q) If necessary, repeat the Patient Leakage Tests for separate measurement of AC and DC readings. Verifying the F-Type Patient Leakage Test Measurement a) Set the PASS / FAIL switch to PASS. b) Set the CF / B-BF switch to B-BF. c) Perform an F-type Patient Leakage Test. d) The measured value will depend on the specific characteristics of the EMSA under test and as such should be taken as a guide only. e) Set the CF / B-BF switch to CF. f) Perform an F-type Patient Leakage Test. g) The measured value will depend on the specific characteristics of the EMSA under test and as such should be taken as a guide only. - 12 -

Table of Leakage Test Values Mains Voltage (V) 210V 220V 230V 240V 250V Earth Leakage 0.500 ma -15% 0.388 0.407 0.425 0.443 0.462 +15% 0.525 0.550 0.575 0.600 0.625 Enclosure Leakage 0.100 ma -15% 0.078 0.081 0.085 0.089 0.092 +15% 0.105 0.110 0.115 0.120 0.125 Patient Leakage AC (B/BF) 0.100 ma -15% 0.078 0.081 0.085 0.089 0.092 +15% 0.105 0.110 0.115 0.120 0.125 Patient Leakage AC (CF) 0.010 ma -15% 0.008 0.009 0.009 0.009 0.010 +15% 0.011 0.011 0.012 0.013 0.013 Patient Leakage DC 0.010 ma -50% 0.005 0.005 0.005 0.005 0.005 +50% 0.014 0.014 0.015 0.016 0.016 F-Type Leakage BF -50% 2.500 (Nominal) CF -50% 0.025 NOTE: The table above only gives ma values corresponding to 10Vsteps of Mains voltage and as such are included for guidance only. In order to gain a more accurate value it is necessary to either refer to Appendix 1 or connect a meter to the supply monitor (Fig. 1 (4)) and calculate the actual current using the equation below:- I = nominal current x supply monitor voltage 230 Where nominal current is that specified in the table under the 230V column. - 13 -

Specifications (15 to 30 C) Earth bond Test current Maximum test duration Earth Bond Reading up to 25A AC or DC 10 seconds Nominal values Insulation Reading +/- 1% Earth Leakage +/- 0.5% Enclosure Leakage +/- 0.5% Patient Leakage +/- 0.5% Patient F-Type Leakage Nominal values Environmental Operating 15ºC to 30ºC (non condensing) Storage 0ºC to 50ºC (non condensing) Maximum RH 90% Supply Rating 230V +/- 10% 50/60Hz Fuse Rating 2 x 1A 500V HRC Protection Rating IP40 General Weight Size < 3.2 kg 250 * 140 * 200 mm Maintenance Ensure the unit is clean and dry before use. Check the condition of casing and cable regularly. Avoid storage in damp conditions and excessive temperature variations. Return for Re-calibration every 3 years. - 14 -

Warranty & Repair For calibration or repair please return the instrument to:- Rigel Medical Service Dept., Seaward Electronic Limited. Bracken Hill South West Industrial Estate Peterlee, Co. Durham SR8 2SW, England Tel : +44 (0)191 586 3511 Fax: +44 (0)191 586 0227 sales@rigelmedical.com calibration@seaward.co.uk www.rigelmedical.com www.seaward.co.uk Prior to returning your unit for service, please contact our service department to obtain a Returns Number. By obtaining a Returns Number, your service request can be booked in advance thus reducing the down time of your equipment. When asking for a Returns Number, please quote: Instruments name and model Serial number Service request (ie calibration, repair ) - 15 -

Mains Voltage (V) Limit 207V 208V 209V 210V 211V 212V 213V 214V 215V 216V Earth Leakage 0.500 ma -15% 0.383 0.384 0.386 0.388 0.39 0.392 0.394 0.395 0.397 0.399 15% 0.518 0.52 0.523 0.525 0.528 0.53 0.533 0.535 0.538 0.54 Enclosure Leakage 0.100 ma -15% 0.077 0.077 0.077 0.078 0.078 0.078 0.079 0.079 0.079 0.08 15% 0.104 0.104 0.105 0.105 0.106 0.106 0.107 0.107 0.108 0.108 Patient Leakage AC (B/BF) 0.100 ma -15% 0.077 0.077 0.077 0.078 0.078 0.078 0.079 0.079 0.079 0.08 15% 0.104 0.104 0.105 0.105 0.106 0.106 0.107 0.107 0.108 0.108 Patient Leakage AC (CF) 0.010 ma -15% 0.008 0.008 0.008 0.008 0.008 0.008 0.008 0.008 0.008 0.008 15% 0.01 0.01 0.01 0.011 0.011 0.011 0.011 0.011 0.011 0.011 Patient Leakage DC 0.010 ma -50% 0.005 0.005 0.005 0.005 0.005 0.005 0.005 0.005 0.005 0.005 50% 0.014 0.014 0.014 0.014 0.014 0.014 0.014 0.014 0.014 0.014 Mains Voltage (V) Limit 217 218 219 220 221 222 223 224 225 226 Earth Leakage 0.500 ma -15% 0.401 0.403 0.405 0.407 0.408 0.410 0.412 0.414 0.416 0.418 15% 0.543 0.545 0.548 0.550 0.553 0.555 0.558 0.560 0.563 0.565 Enclosure Leakage 0.100 ma -15% 0.080 0.081 0.081 0.081 0.082 0.082 0.082 0.083 0.083 0.084 15% 0.109 0.109 0.110 0.110 0.111 0.111 0.112 0.112 0.113 0.113 Patient Leakage AC (B/BF) 0.100 ma -15% 0.080 0.081 0.081 0.081 0.082 0.082 0.082 0.083 0.083 0.084 15% 0.109 0.109 0.110 0.110 0.111 0.111 0.112 0.112 0.113 0.113 Patient Leakage AC (CF) 0.010 ma -15% 0.008 0.008 0.008 0.008 0.008 0.008 0.008 0.008 0.008 0.008 15% 0.011 0.011 0.011 0.011 0.011 0.011 0.011 0.011 0.011 0.011 Patient Leakage DC 0.010 ma -50% 0.005 0.005 0.005 0.005 0.005 0.005 0.005 0.005 0.005 0.005 50% 0.014 0.014 0.014 0.014 0.014 0.014 0.015 0.015 0.015 0.015

Mains Voltage (V) Limit 227V 228V 229V 230V 231V 232V 233V 234V 235V 236V Earth Leakage 0.500 ma -15% 0.419 0.421 0.423 0.425 0.427 0.429 0.431 0.432 0.434 0.436 15% 0.568 0.570 0.573 0.575 0.578 0.580 0.583 0.585 0.588 0.590 Enclosure Leakage 0.100 ma -15% 0.084 0.084 0.085 0.085 0.085 0.086 0.086 0.086 0.087 0.087 15% 0.114 0.114 0.115 0.115 0.116 0.116 0.117 0.117 0.118 0.118 Patient Leakage AC (B/BF) 0.100 ma -15% 0.084 0.084 0.085 0.085 0.085 0.086 0.086 0.086 0.087 0.087 15% 0.114 0.114 0.115 0.115 0.116 0.116 0.117 0.117 0.118 0.118 Patient Leakage AC (CF) 0.010 ma -15% 0.008 0.008 0.008 0.009 0.009 0.009 0.009 0.009 0.009 0.009 15% 0.011 0.011 0.011 0.012 0.012 0.012 0.012 0.012 0.012 0.012 Patient Leakage DC 0.010 ma -50% 0.005 0.005 0.005 0.005 0.005 0.005 0.005 0.005 0.005 0.005 50% 0.015 0.015 0.015 0.015 0.015 0.015 0.015 0.015 0.015 0.015 Mains Voltage (V) Limit 237V 238V 239V 240V 241V 242V 243V 244V 245V 246V Earth Leakage 0.500 ma -15% 0.438 0.440 0.442 0.443 0.445 0.447 0.449 0.451 0.453 0.455 15% 0.593 0.595 0.598 0.600 0.603 0.605 0.608 0.610 0.613 0.615 Enclosure Leakage 0.100 ma -15% 0.088 0.088 0.088 0.089 0.089 0.089 0.090 0.090 0.091 0.091 15% 0.119 0.119 0.120 0.120 0.121 0.121 0.122 0.122 0.123 0.123 Patient Leakage AC (B/BF) 0.100 ma -15% 0.088 0.088 0.088 0.089 0.089 0.089 0.090 0.090 0.091 0.091 15% 0.119 0.119 0.120 0.120 0.121 0.121 0.122 0.122 0.123 0.123 Patient Leakage AC (CF) 0.010 ma -15% 0.009 0.009 0.009 0.009 0.009 0.009 0.009 0.009 0.009 0.009 15% 0.012 0.012 0.012 0.012 0.012 0.012 0.012 0.012 0.012 0.012 Patient Leakage DC 0.010 ma -50% 0.005 0.005 0.005 0.005 0.005 0.005 0.005 0.005 0.005 0.005 50% 0.015 0.016 0.016 0.016 0.016 0.016 0.016 0.016 0.016 0.016-17 -

Mains Voltage (V) Limit 247V 248V 249V 250V 251V 252V 253V Earth Leakage 0.500 ma -15% 0.456 0.458 0.460 0.462 0.464 0.466 0.468 15% 0.618 0.620 0.623 0.625 0.628 0.630 0.633 Enclosure Leakage 0.100 ma -15% 0.091 0.092 0.092 0.092 0.093 0.093 0.094 15% 0.124 0.124 0.125 0.125 0.126 0.126 0.127 Patient Leakage AC (B/BF) 0.100 ma -15% 0.091 0.092 0.092 0.092 0.093 0.093 0.094 15% 0.124 0.124 0.125 0.125 0.126 0.126 0.127 Patient Leakage AC (CF) 0.010 ma -15% 0.009 0.009 0.009 0.009 0.009 0.009 0.009 15% 0.012 0.012 0.012 0.013 0.013 0.013 0.013 Patient Leakage DC 0.010 ma -50% 0.005 0.005 0.005 0.005 0.005 0.005 0.006 50% 0.016 0.016 0.016 0.016 0.016 0.016 0.017-18 -