Standard Operating Procedure for H 2 S and SO 2 Converter

Similar documents
Title: Standard Operating Procedure for Elemental and Organic Carbon (EC and OC) using Non-Dispersive Infrared Detection (NDIR)

Title: Standard Operating Procedure for Measurement of Ethylene (C 2 H 4 ) in Ambient Air by Reduced Gas Detection (RGD)

Title: Standard Operating Procedure for R&R Environmental Devices Model MFC201 Gas Dilution Calibrator

Title: Standard Operating Procedure for Dasibi Model 5008 Gas Dilution Calibrator

Title: Standard Operating Procedure for Sabio 2010 and 4010 Dilution Calibrator

WBEA Standard Operating Procedure

Thermo Scientific Model 146i Principle of Operation

Appendix D: SOP of INNOVA 1412 Photoacoustic Multi-Gas Monitor. Description and Principle of Operation

METHOD 3C - DETERMINATION OF CARBON DIOXIDE, METHANE, NITROGEN, AND OXYGEN FROM STATIONARY SOURCES

Air Monitoring Directive Chapter 7: Calibration

This test shall be carried out on all vehicles equipped with open type traction batteries.

Application Note AN-107

METHOD 3A - DETERMINATION OF OXYGEN AND CARBON DIOXIDE CONCENTRATIONS IN EMISSIONS FROM STATIONARY SOURCES (INSTRUMENTAL ANALYZER PROCEDURE)

White Paper. Chemical Sensor vs NDIR - Overview: NDIR Technology:

Model 601CV. Mass Flow Controller. Product Features:

Title: Standard Operating Procedure for The Tapered Element Oscillating Microbalance (TEOM)

METHOD 25A - DETERMINATION OF TOTAL GASEOUS ORGANIC CONCENTRATION USING A FLAME IONIZATION ANALYZER

HIGH ACCURACY MULTI-GAS MONITORING USING AUTOMATED SELF- CALIBRATION

Protocol Gas Verification For Compressed Gas Cylinders Containing Either SO 2, NO or CO. Quality Assurance Plan/Standard Operating Procedure

LUMAZOTE T ECHNICAL BRO CHU RE

Instruction and Maintenance Manual

METHOD 21 - DETERMINATION OF VOLATILE ORGANIC COMPOUND LEAKS. 1.2 Scope. This method is applicable for the

Calibration Requirements for Direct Reading Confined Space Gas Detectors

Multiple Gas#5 GC configuration Jan 2016

Commercial Practice Test Method Internal Vapor Analysis of Hermetic Devices

Dissolved Oxygen Guide

Elimination of Percent Level H 2 S Calibration Gas from Flare Gas Monitoring Systems Measuring Total Sulfur, H 2 S and BTU.

INDUSTRIAL HYGIENE GROUP Standard Operating Procedure. TVA-1000 PID/FID Portable Toxic Vapor analyzer. 1 of 9. Contents

Advanced Test Equipment Rentals ATEC (2832)

AUK Environmental Sensor. Determining the refractive index of the air. AUK Environmental Sensor

EasyLine Continuous Gas Analyzers. So smart, they re simple

How to specify a product. Process Sensors and Mechanical Instruments

Oxygen & Binary Gas Measurement and Analysis

Electrochemical Sensor

Electrochemical Carbon Monoxide Gas Sensor (Model:ME3-CO) Manual. Version 1.2 Valid from May 1 st 2014

It s Just Calibration How Hard Can It Be?

SPECIFICATION. date of manufacture. Intermittent: -20 o C to +50 o C. Pressure Range:

APTI 464. Analytical Methods for Air Quality Standards. Laboratory Exercise Manual. March 2010

Electrochemical Sensor

8.1 Calibration of gas sensors

ME3-HCL Electrochemical sensor

SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT METHOD INSTRUMENTAL ANALYZER PROCEDURES FOR CONTINUOUS GASEOUS EMISSION SAMPLING

6200E Installation Requirements

ONH836 Series: Oxygen/Nitrogen/Hydrogen by Inert Gas Fusion

SPECIFICATION. date of manufacture. Intermittent: -20 o C to +50 o C. Pressure Range:

Ultima. X Series Gas Monitor

CORESTA RECOMMENDED METHOD N 6

Generating Calibration Gas Standards

LFE OEM TCD - Thermal Conductivity Detector

Oxygen Flue Gas Analyzer BA 2000

Chapter 5. Sulfur Dioxide Measurement Principles and Calibration Procedures. Introduction

What I have learned about SF 6 gas testing.a Practical explanation

Applications Note: Use of "pentane equivalent" calibration gas mixtures

DEVICES FOR FIELD DETERMINATION OF WATER VAPOR IN NATURAL GAS Betsy Murphy MNM Enterprises 801 N. Riverside Drive Fort Worth, Texas 76111

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

PQ Performance Qualification - Page 1/13

MMS Mercury Monitoring System for Natural Gas

Continuous gas analysis ULTRAMAT 23 Supplement 2 for Operating Instructions C79000-G52xx- C216-03

Flare Gas Composition Analysis and QA/QC Lessons Learned and Lessons Lost SPECTRUM ENVIRONMENTAL SOLUTIONS, LLC 1

HYDROSTATIC LEAK TEST PROCEDURE

PERFORMANCE SPECIFICATION PROPELLANT, HYDROGEN

Instruction and Maintenance Manual

Diffusing Capacity: 2017 ATS/ERS Standards for single-breath carbon uptake in the lung. Susan Blonshine RRT, RPFT, FAARC, AE-C

Selecting the right pressure sensor for your application

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

Gases&Technology. Measurement of Impurities in Helium Using the Dielectric Barrier Discharge Helium Ionization Detector. FEATURE.

CHAPTER 16 %UHDWKLQJ*DV0L[LQJ3URFHGXUHV

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs.

ACCURACY, PERFORMANCE, AND HANDLING OF OIL-FILLED DIGIQUARTZ PRESSURE INSTRUMENTATION

Technical Data Sheet MF010-O-LC

PRODUCT CONFORMITY CERTIFICATE

Standard Operating Procedure

ISO INTERNATIONAL STANDARD

STANDARD OPERATING PROCEDURES

Drilling Efficiency Utilizing Coriolis Flow Technology

BAROMETER PRESSURE STANDARD PRESSURE CONTROLLER

OxiQuant S. Operating Instructions

APPENDIX C. 40 CFR PART 60 App. B SPEC. 1-4, 6

Royce Interface Level Analyzer and Sensors

LINEAR TRANSFORMATION APPLIED TO THE CALIBRATION OF ANALYTES IN VARIOUS MATRICES USING A TOTAL HYDROCARBON (THC) ANALYZER

Hazard Analysis Worksheet STEP #10: UNDERSTAND THE POTENTIAL HAZARD.

MIL-STD-883G METHOD

Test Plans & Test Results

Met One E-BAM Particulate Monitor

FTC130 Transmitter. Operating Manual

Mass Flow Controllers

Misuse of Combustible Gas Meters

STD-3-V1M4_1.7.1_AND_ /15/2015 page 1 of 6. TNI Standard. EL-V1M4 Sections and September 2015

A. Evaluation of the written program

RGC-IR Remote Gas Calibrator for IR400

Iowa Exceedances of the National Ambient Air Quality Standards, 2013 (Reported Through October 8 th ) Iowa DNR Ambient Air Monitoring Group

ISO INTERNATIONAL STANDARD

HCL MONITORING. ICAC MARAMA WORKSHOP May 18-19th, Presented by: Ty Smith. CEMTEK

ON736 Series: Oxygen/Nitrogen by Inert Gas Fusion

Automated Determination of Dissolved Gases in Water Anne Jurek. Abstract: Discussion:

VIC offers a variety of Calibrated Gas Leaks

Operation manual Oxygen sensor

OPTIMA 7 - BIOGAS Calibrating the gas sensors SENSOR ADJUSTMENT. Diamond Scientific 625 Peachtree St., Cocoa, Florida /Tel:

Supporting Information for Micro-Collection of. Gases in a Capillary Tube: Preservation of Spatial

NZQA unit standard 7145 version 9 Page 1 of 5. Design and maintain effective ventilation systems for an underground coal mine

Transcription:

Procedure No: SOP-001 Revision No: 1.0 January 24, 2011 Page No.: 1 of 6 1. INTRODUCTION AND SCOPE This procedure describes the operation and configuration of heated converters used in continuous ambient measurements of H 2 S and TRS coupled with a continuous SO 2 fluorescence analyzer. This method adheres to the requirements of the current Air Monitoring Directive (AMD). In some cases the limits and specifications exceed the requirements of the current AMD. It should be considered that the current and any future amendments of the AMD will be used as the benchmark for requirements and criteria for ambient air monitoring practices conducted in the Province of Alberta. Information used to write this procedure was also taken from sources identified in the reference section. 2. PRINCIPLE OF THE METHOD Currently H 2 S/TRS is measured using thermal oxidation to convert H 2 S or TRS molecules to SO 2. The converted SO 2 molecules are then analyzed using continuous fluorescent SO 2 analyzers. H2S H 2 S molecules will be oxidized to SO 2 in the presence of Oxygen and heat. This is accomplished by diverting the sample flow, after a scrubber to remove hydrocarbons, through the H 2 S converter. The converter is a Stainless Steel body heated to at least 320 degrees centigrade. Prior to the converter, the sample flow passes through a scrubber to remove all SO 2, and allow only the H 2 S molecules to pass through to enter the H 2 S converter. The H 2 S molecules are then converted to SO 2 as illustrated in the following equation. Specifically; H 2 S + O 2 +heat SO2 + H 2 O The converted SO 2 molecules then return to the standard SO 2 analyzer for detection and are reported as H 2 S.

Procedure No: SOP-001 Revision No: 1.0 January 24, 2011 Page No.: 2 of 6 TRS Total Reduced Sulphur compounds include a variety of airborne compounds that contain Sulphur. Some of the common ones found in Alberta are; Carbonyl Sulphide (COS), Carbon Disulphide (CS 2 ) and Methyl Mercaptan (CH 3 SH). Similar to H 2 S, TRS molecules will be oxidized to SO 2 in the presence of Oxygen and heat. The difference between H 2 S and TRS is that the TRS conversion requires a higher temperature. This is accomplished by, diverting the sample flow, after the hydrocarbon scrubber, through a TRS converter. The TRS converter is a Quartz tube heated to a minimum of 800 degrees centigrade. Prior to the converter, the sample flow must pass through a scrubber to remove all SO 2, and allow only the TRS molecules to pass through to enter the TRS converter. The TRS molecules are then converted to SO 2 as illustrated in the following equation. Specifically; TRS + O 2 +heat SO2 + H 2 O The converted SO 2 molecules then return to the standard SO 2 analyzer for detection and are reported as TRS. 3. MEASUREMENT RANGE AND SENSITIVITY H 2 S and TRS converters are capable of converting concentrations in the range of most current systems, typically 0 to 100 ppm. If the converter is running with all parameters in the range they should be, the sensitivity of the converter is generally better than the analyzer measuring the concentrations. 4. EQUIPMENT AND APPARATUS The following are available commercial converters configured specifically for the measurement of H 2 S and TRS, are suitable for used in this method and are currently in use in the AENV network: Thermo Environmental Instruments model 340 H 2 S converter CD Nova model CDN 101 TRS converter

Procedure No: SOP-001 Revision No: 1.0 January 24, 2011 Page No.: 3 of 6 This list does not exclude the use of other equipment that has received the USEPA Reference and Equivalent Method designation. 5. INTERFERENCES See manufacturer s specification. 6. PRECISION AND ACCURACY The analyzer measuring the SO 2 concentrations governs precision and accuracy for these systems. The measurement precision is generally considered to be the repeatability of the measurement. Precision of the data output by the analyzer is established by the manufacturer, but confirmed during daily span checks and monthly calibrations. See section 10.0 in this document for information on daily calibration checks. The accuracy of the sensor is generally considered the deviation from true. This means how close it is to what it should be. The benchmark of what it should be is provided by the Alberta Environment Audit Program staff and the use of transfer standards such as those available from the National Institute of Standards and Technology (NIST). As with precision, accuracy is confirmed by the daily span checks and monthly calibrations. Refer to the sections identified above for further information on accuracy relating to calibration and audit procedures 7. SITE REQUIREMENTS Site location for SO 2 monitoring should be determined according to the intended application of the monitoring data. Detailed requirements for selection of sites for monitoring ambient SO 2 can be found in Optimum Site Exposure Criteria for SO 2 Monitoring EPA-450/3-77-013. Requirements for the immediate surroundings of ambient monitoring sites can be found in Air Monitoring Directive.

Procedure No: SOP-001 Revision No: 1.0 January 24, 2011 Page No.: 4 of 6 8. INSTALLATION REQUIREMENTS All the installation requirements are specified by the manufacturer in the installation procedures of the manual. General requirements listed below must also be followed. Considerations for siting requirements can be found in the reference listed in section 7.0 above. Site location for H 2 S and TRS converters is considered as to where they should be installed in the instrument rack. As both the H 2 S and TRS converters are heated, they should not be located close to any other instrumentation in the rack. This is so the heat from the converter does not affect the performance of other analyzers in the rack. When installing the converter, follow the instructions found in the operation manual. One consideration is to keep the tubing from the analyzer and back to the analyzer as short as possible. 8.1. Converter Optimization after the analyzer has been installed, the converter temperature must be optimized. This process should be completed annually. This task involves the following steps: 8.1.1. Have the analyzer running and all connections made 8.1.2. Connect the calibration gas source using a calibrator capable of generating selected concentrations 8.1.3. Generate a concentration of H 2 S at 80% of full scale and wait for the analyzer response to stabilize 8.1.4. Increase the converter temperature at increments of 5 degrees, and wait for stable response between each change. The response will start to drop once the optimum temperature has been passed. 8.1.5. Decrease the converter temperature at increments of 5 degrees, and wait for stable response between each change. The response will start to drop once the optimum temperature has been passed. 8.1.6. The median temperature between these two points is where the converter should be operated

Procedure No: SOP-001 Revision No: 1.0 January 24, 2011 Page No.: 5 of 6 9. OPERATIONAL REQUIREMENTS The operational requirements for H 2 S and TRS converters follow the requirements outlined in the H 2 S/TRS operating procedure. See this procedure for details. 10. CALIBRATION The calibration procedure for H 2 S/TRS converters is to check the temperature of the heated block or tube with an external temperature measuring device. This temperature is compared to the displayed temperature on the setpoint display. If the temperatures agree within the specified range given in the operations manual, then no action needs to be taken. If they differ, follow the troubleshooting steps in the operations manual. 11. APPLICABLE DOCUMENTS EM-001a Thermo Environmental Instruments (TEI) Model 340 H2S Converter Operating Manual EM-001b CD Nova model CDN101 TRS Converter Operating Manual 12. LITERATURE REFERENCES None 13. REVISION HISTORY Revision 0 (new document) Revision 1 Grammatical changes.

Procedure No: SOP-001 Revision No: 1.0 January 24, 2011 Page No.: 6 of 6 14. APPROVAL Approved by: Harry Benders Date: January 24, 2011 Air Monitoring Manager