Application Note 183. Page 1 of Aero Camino, Goleta, CA Tel (805) Fax (805)

Similar documents
Application Note 268 Metabolic Analysis Systems and Propane-based Verification

Recording established using the VO2 and RER graph template file (h19.gtl)

O2100C Oxygen Measurement Module Technical Use Notes do not use other wall adapters with the O2100Cmodule. 10% / V 5% / V 2% / V 1% / V 10% / V

Air Flow & Gas Analysis Accessories

BSL PRO Lesson H19: V O 2, V CO 2, RER, O 2 deficit and EPOC Measurement. Objectives: Equipment:

O 6 = 6 CO H 2 O H 2 = 16 CO 2. consumed during the oxidation of fatty acids, a ratio of 0.7.

Experiment HE-9: Resting, Active, and Exercising Metabolic Rates

iworx Sample Lab Experiment HE-4: Respiratory Exchange Ratio (RER)

GA-300 Gas Analyzer. Technical Note. Overview. Front Panel. iworx Systems, Inc. GA-300

iworx Sample Lab Experiment HE-5: Resting Metabolic Rate (RMR)

PRODUCT SHEET. See also: Student Accessory Pack BSL-ACCPACK and BSLACCPACK-11B AFT7 AFT7L AFT12 AFT6A AFT27 AFT16

iworx Sample Lab Experiment HE-5: Resting Metabolic Rate (RMR)

Understanding the Issues Affecting the Accuracy of Measuring Oxygen Consumption Utilizing Metabolic Carts

Experiment HE-9: Resting, Active, and Exercising Metabolic Rates

Experiment AMe-1: Small Animal Respiratory Exchange Ratio (RER)

Content Display. - Introduction. Laboratory Unit : Lab 2 - Measurement of Oxygen Consumption. KINE xxxx Exercise Physiology

Experiment AMe-1: Small Animal Respiratory Exchange Ratio (RER)

bespoke In general health and rehabilitation Breath-by-breath multi-functional respiratory gas analyser In human performance

Resting, Active, and Exercising Metabolic Rates

Review of gas frac9ons in atmospheric air 2/2/16. Metabolic Calculations of Indirect Calorimetry. Expired gas analysis.

Lesson 12 New Procedure PULMONARY FUNCTION I

Pulmonary Function I (modified by C. S. Tritt, April 10, 2006) Volumes and Capacities

Overview. Front Panel: Keypad and Display

PRODUCT SHEET. Order probe only as RXPROBE02

Appendix D: SOP of INNOVA 1412 Photoacoustic Multi-Gas Monitor. Description and Principle of Operation

VT900A + VAPOR. Technical data. One Solution. Auto-detection to Ensure Patient Safety. Key benefits and features

BREATH-BY-BREATH METHOD

Gas exchange measurement in module M- COVX

iworx Metabolic Accessories

Diffusing Capacity: 2017 ATS/ERS Standards for single-breath carbon uptake in the lung. Susan Blonshine RRT, RPFT, FAARC, AE-C

LUNG CLEARANCE INDEX. COR-MAN IN Issue A, Rev INNOVISION ApS Skovvænget 2 DK-5620 Glamsbjerg Denmark

CARDIOVIT AT-104 ergospirometry

HESTA Issues affecting the accuracy of Metabolic Carts. Danny Rutar

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs.

Lung Volumes and Capacities

SomnoSuite FAQ. Setup. Calibration 4. What are the calibration requirements for the SomnoSuite? Settings

Figure 1. A schematic diagram of the human respiratory system.

Biology 13A Lab #12: The Respiratory System

GE Healthcare. CARESCAPE R860 Nutritional Assessment Tools Appliguide

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

A CO 2 Waveform Simulator For Evaluation and Testing of Respiratory Gas Analyzers

Specifications...Easy CLIA Classification: Sample Type: Blood gas analyzer operation has never been simpler Sample Size: Measured Parameters PCO2

Pegas 4000 MF Gas Mixer InstructionManual Columbus Instruments

AC : MEASUREMENT OF HYDROGEN IN HELIUM FLOW

Mass Spec will not Autotune

Gas Pressure Sensor (Order Code GPS-BTA)

The HumiPyc ( Model 2) - Gas Pycnometer; Density, Moisture, Permeation Analyzer; Filter Integrity Tester; RH sensor Calibrator

TERMINOLOGY AND SYMBOLS USED LN RESPIRATORY PHYSIOLOGY. Assistant, Medical Unit, Middlesex Hospital, London, W.i

Mouse and Rat Tail Cuff Blood Pressure Systems from 1-24 Animals. Mouse rat tail cuff blood pressure system components

Radnoti Liver Perfusion System

Application Note AN-107

SS32L Dissolved O 2 Probe

Cover Page for Lab Report Group Portion. Pump Performance

Homecare Pneumology NEONATOLOGY ANAESTHESIA INTENSIVE CARE VENTILATION Step beyond the future

Environmental Petrochemical, Pharmaceutical, Foods & Flavors, Chemicals, Personal Care, Forensics,...and more!

The physiological functions of respiration and circulation. Mechanics. exercise 7. Respiratory Volumes. Objectives

12. Laboratory testing

Biology Unit 2, Structure of Life, Lab Activity 2-3

Lab 1c Isentropic Blow-down Process and Discharge Coefficient

STANDARD OPERATING PROCEDURES. Andersen Instruments Federal Reference Method (FRM) Ambient Particulate (PM 10 /PM 2.

Quality assurance of Modular Metabolic Systems. Danny Rutar, Redback Biotek, Ireland/Australia Jeffrey Swen(Intern), University of Ulster, Belfast.

Blood Parameter Monitoring System 550

The HumiPyc - Model 1 - Gas Pycnometer; Density, Moisture, Permeation Analyzer; RH sensor Calibrator

Fish Respiration and Q 10

Pneumatic high-pressure controller Model CPC7000

Cover Page for Lab Report Group Portion. Head Losses in Pipes

IMPC phenotyping SOPs in JMC

VT PLUS HF performance verification of Bunnell Life-Pulse HFJV (High Frequency Jet Ventilator)

Operation Manual. Pro 4 Warn Analyzer TM Rev 08.17

Constant Pressure Inlet (CCN) Operator Manual

Code Basic module and level control complete with optionals code

KEM Scientific, Inc. Instruments for Science from Scientists

VT650. Gas Flow Analyzer. Technical data. Key benefits and features:

Determination of the Frequency Response of an End Tidal CO2 Analyser

- Repeat calibration until desired results are reached otherwise set SW2 and SW1-8 open.

Calcium Reactor. CalcFeeder PRO. User Manual 1.1a. Model. CalcFeeder AC1 PRO CalcFeeder AC2 PRO CalcFeeder AC3 PRO CalcFeeder AC4 PRO

Overview. 2 Module 13: Advanced Data Processing

Columbus Instruments

LAB 7 HUMAN RESPIRATORY LAB. Complete the charts on pgs. 67 and 68 and read directions for using BIOPAC

Test Plans & Test Results

Technical Data Sheet MF010-O-LC

Traceability and Evidential Breath Analyser

6 Common Hydrodynamic Testing Mistakes

HumiSys HF High Flow RH Generator

Armfield Distillation Column Operation Guidelines

Lab #1 Pressure: Bubblers and Water Balloons CEE 331 Fall 2003

Respiratory Response to Physiologic Challenges. Evaluation copy

Kölling et al., Supplemental Figures.

D-Opto Dissolved Oxygen Sensor Operation Manual for the D-Opto 4-20mA

Powers Controls RC 195 Multiple Input Receiver- Controller

Advances in Capillary Column Backflushing

Pneumatic high-pressure controller Model CPC7000

OXYGEN CONSUMPTION AND TEMPERATURE IN THE AQUATIC ENVIRONMENT

ISE-730 Oxygen Electrode and DO2-100 Currentto-Voltage

MEGAS 2.0. Gas analysis with direct C-Level Calculation and Bus-Connection. Data sheet

VT900. Gas Flow Analyzer. Technical data. Key benefits and features:

TEL/jlRE" Introduction. Display Features and Modes. Startup Procedure. Power-Up Procedure. Adjustment Modes

Experiment C-6 Gas Solubility

COMPARISON OF DIFFERENTIAL PRESSURE SENSING TECHNOLOGIES IN HOSPITAL ISOLATION ROOMS AND OTHER CRITICAL ENVIRONMENT APPLICATIONS

IEP SENSOR BRACKET CHECKOUT AND VERIFICATION. This is a non-hazardous test.

Transcription:

APPLICATION NOTE 42 Aero Camino, Goleta, CA 93117 Tel (805) 685-0066 Fax (805) 685-0067 info@biopac.com www.biopac.com 7.10.18 Application Note 183 VO 2 and RER Measurement For simplified VO 2 measurement (without CO 2 values), use Application Note AS221. Humidity effects of tubing, filters, and module setup are discussed in the O2100C-CO2100C spec sheet for Gas Concentration Measurement Modules. The MP160/MP150 System with the O2100C and DA100C modules and some airflow accessories can be used to perform precise real-time Oxygen Consumption (VO 2 ) and Respiratory Exchange Ratio (RER) measurements. When performing tests of this kind, many factors exist to confound the measurement. For this simplified measurement, it is assumed that the volume of expired air is always the same as inspired air. This is only true when the volume of carbon dioxide expired is equal to the volume of oxygen consumed. The inspired and expired volumes are equal only when the respiratory exchange ratio (RER) equals one. The Respiratory Exchange Ratio (RER) is defined as VCO 2 produced divided by VO 2 consumed (where V is Volume). Accordingly, when performing these measurements, precise determination of inspired and expired volumes plus accurate gas concentration level recording is required. This application note focuses on the details of the setup and calculations to obtain precise VO 2 and RER measurements from resting or exercising subjects. The subjects breathe through a non-rebreathing "T" valve to inspire fresh air through a pneumotach (TSD107B) and expire to a mixing chamber for gas concentration (O 2 and CO 2 ) monitoring. When using a mixing chamber to average CO 2 and O 2 concentrations over several breaths, there is no performance degradation (due to the module gas concentration response time) when measuring these changes for arbitrarily high breathing rates. Accordingly, a mixing chamber is typically recommended for quick, accurate and easy metabolic analysis. Additional accessories required, but not shown, include a calibration syringe (AFT6A) and calibrated gas mixture. The calibration syringe is used to calibrate the TSD107B and to flush out the mixing chamber for ambient gas concentration level calibration. The calibrated gas mixture (BIOPAC s GASCAL with GASREG) is used to introduce known concentrations of CO 2 and O 2 to calibrate the upper and lower ranges of the gas measurement module respectively. Page 1 of 8

Setup Procedure Mouthpiece AFT9 TSD107B Airflow Transducer Flow In 5 liter Mixing Chamber AFT15A AFT21 nonrebreathing T valve AFT7 Smooth Bore Tubing Flow Out Plugs into DA100C Module 5 micron filter AFT20 CO2100C Module 2 meter Sampling line AFT20 NAFION Tubing AFT20 O2100C Module Equipment Connections for VO 2 and RER Measurement The above diagram illustrates the typical connections when performing metabolic analysis. The subject breathes through the mouthpiece (AFT9) which attaches directly to the non-rebreathing "T" valve (AFT21). It s very important that any extraneous volumes are minimized between the subject and the "T" valve. Additional volumes affect the effective expired gas concentration levels. When the subject inspires, air is drawn into the AFT21 as shown by the "Flow In" arrow, through the TSD107B airflow transducer. The TSD107B is placed on the inspiration side to eliminate any effects associated with expired air humidity. When the subject expires, air is directed out to the 5 liter mixing chamber (AFT15A). The O2100C module connects to the mixing chamber via an AFT20 gas sampling interface kit. The gas sampling interface kit acts to filter and dehumidify the expired gases residing within the mixing chamber. The non-rebreathing "T" valve directs only expired air to the 5 liter mixing chamber. Because only expired air is directed to the chamber, the mixing chamber acts to average respiratory outflows. This averaging effect causes the O 2 concentration to vary in accordance with the mean values resident in several expired breaths. The size of the mixing chamber determines the extent of the averaging effect. For example, assuming the subject s expired breath volume is typically 0.5 liters, the AFT15A mixing chamber will average about 10 expired breaths. The TSD107B airflow transducer signal is amplified by a DA100C amplifier, which is attached to the MP System along with the CO2100C and O2100C modules. Accordingly, two channels of analog data need to be acquired to properly measure oxygen consumption and the Respiratory Exchange Ratio. Page 2 of 8

Definitions O e 2 Fi N 2 e Vi Vis Ves VO 2 Oxygen fractional concentration in expired air Inspired air flow (ATP) Nitrogen fractional concentration in expired air Inspired air volume (ATP) Inspired air volume (STPD) Expired air volume (STPD) Volume of oxygen consumed (STPD) AcqKnowledge Software Setup 1. Set up AcqKnowledge to record three analog channels (A1, A2 and A3). For this application note, the input signals are assigned as follows: A1 (CO 2 e): Carbon dioxide concentration from CO2100C module A2 (O 2 e): Oxygen concentration from O2100C module A3 (Fi): Inspired flow from TSD107B via DA100C module Analog Input Setup for VO 2 and RER Measurement 2. Set up seven calculation channels as shown below, using parameters and expressions shown on pages 4-6. Calculation Channel Setup for VO 2 and RER Measurement Page 3 of 8

The calculated signals are assigned to the AcqKnowledge calculation channels as shown below: C0 N 2 e: Nitrogen fractional concentration in expired air C1 Vi: Inspired air volume (ATP) C2 Vis: Inspired air volume (STPD) C3 Ves: Expired air volume (STPD) C4 VO 2 : Volume of oxygen consumed (STPD) C5 VCO 2 : Volume of carbon dioxide produced (STPD) C6 RER: Respiratory Exchange Ratio C0 - Expression: N 2 e Nitrogen fractional concentration in expired air Because both the carbon dioxide and oxygen concentrations are known, it s possible to determine the concentration of expired nitrogen using the following formula. N 2 e = 100 (CO 2 e + O 2 e) N 2 e calculation for VO 2 and RER Measurement C1 - Integrate: Vi Inspired air volume (ATP) Since the TSD107B is placed in the "Flow In" line, the flow of inspired air can be determined over a running 30 second interval, by integrating the flow signal using the expression (30 seconds equals 6000 samples at a 200 Hz sampling rate): Vi = Integrate(Fi) over 30 sec period Vi calculation for VO 2 and RER Measurement Page 4 of 8

C2 - Expression: Vis Inspired air volume (STPD) Convert gas at Ambient Pressure and Temperature (APT) to Standard Temperature and Pressure, Dry (STPD): Vis = Vi*(273/(273+Ta))*((Pb-PH20)/760) where Ta is ambient temperature (e.g. 24 deg C) Pb is ambient barometric pressure (e.g. 745 mmhg) PH20 is ambient pressure of water vapor (e.g. 22.4 mmhg) Vis calculation for VO 2 and RER Measurement C3 - Expression: Ves Expired air volume (STPD) Calculate the expired volume from the inspired volume by using the Haldane transformation (Nitrogen factor); because of the assumption for CO 2 in this setup, Ves = Vis. Ves = (Vis*79.03) / N 2 e where the value 79.03 is the percent N 2 in ambient air. Ves calculation for VO 2 and RER Measurement C4 - Expression: VO 2 Volume of oxygen consumed (STPD) Use the following expression to determine real-time oxygen consumption volume. VO 2 = (1/100)*[(Vis*20.93) (Ves*O 2 e)] where the value 20.93 is the percent O 2 in ambient air. VO 2 calculation for VO 2 and RER Measurement Page 5 of 8

C5 - Expression: VCO 2 Volume of carbon dioxide consumed (STPD) Use the following expression to determine real-time carbon dioxide consumption volume. VCO 2 = (1/100)*[(Ves*CO 2 e) (Vis*.04)] where the value.04 is the percent CO 2 in ambient air. VCO 2 calculation for VO 2 and RER Measurement C6 - RER: Respiratory Exchange Ratio Finally, RER can be calculated by: RER = VCO 2 / VO 2 RER calculation for VO 2 and RER Measurement 3. Set up acquisition as follows: Record and Save Once using Memory or Disk Sample rate: 200 samples/second Acquisition length: 5 minutes or longer Acquisition Setup for VO 2 and RER Measurement Page 6 of 8

Calibration After the software setup, it s very important to calibrate the system for the following three variables: 1) Carbon Dioxide concentration (calibrate in range of.04% to 4% CO 2 ) 2) Oxygen concentration (calibrate in range of 21% to 16% O 2 ) 3) Inspired Flow (calibrate within the range of 0 to 13 liters/sec) The calibrations for these measurements are critical. Once the equipment and software setup is complete, with all the plumbing fixed and secure, gas concentration calibration can proceed. If any changes in plumbing or gas measurement pump speed are effected, it is generally necessary to repeat the gas measurement module calibrations. Flood the mixing chamber with the appropriate gas and concentration levels to proceed with the calibration. First, flood the chamber with fresh (ambient) air. This can be accomplished by attaching the calibration syringe to the mouthpiece and cycling fresh air into the mixing chamber. Monitor the gas concentration changes using AcqKnowledge. When the levels appear stabilized at ambient, obtain the first calibration point. Now flood the chamber with your desired gas mixture (recommended, BIOPAC GASCAL: 4% CO 2, 16% O 2 and 80% N 2 ). When the levels appear stabilized, obtain the second calibration point. The pneumotach (TSD107B) is calibrated by using a calibration syringe to inject a precise volume of air through the flow transducer. Determine the appropriate transducer scaling factor so the area under the recorded flow curve equals the volume injected. Perform the first calibration point by recording the transducer output (from the DA100C) at zero flow. The second point calibration is determined by adding the previously recorded scale factor to the offset recorded by the first calibration point. For more information on gas analysis module and flow transducer calibration, please refer to the MP Hardware Guide or AcqKnowledge Software Guide. Other factors to be recorded for the procedure are the following: Ta: Ambient temperature in degrees C Pb: Ambient barometric pressure in mmhg PH20: Pressure of water vapor at ambient temperature in mmhg These values are important when performing the conversion of gas at Ambient Pressure and Temperature (APT) to Standard Temperature and Pressure, Dry (STPD). The examples below illustrate typical values obtained when performing gas and flow measurement calibrations. In the following cases, the CO2100 module was set to a gain of 1% CO 2 per volt, the O2100C was set to a gain of 10% O 2 per volt, and the DA100C amplifier (connected to TSD107B) was set to a gain of 1000. Note that these are example values only. Do not set your Cal 1 and Cal 2 values to the parameters shown in the examples prior to calibrating. CO2100C Calibration O2100C Calibration TSD107B Calibration Page 7 of 8

Analysis The following graph illustrates the complete real-time Oxygen Consumption and Respiratory Exchange Ratio measurement. All the raw and calculated waveforms are displayed. Note that the VO 2, VCO 2 and RER measurements (bottom three channels) vary smoothly with time. The graphical and continuous nature of this recording and calculation method provides significant information regarding the changes of these variables over time. This particular setup will provide a reading that, at any point in time, indicates the oxygen consumed, the carbon dioxide produced and the respective respiratory exchange ratio in the last 30 seconds. Accordingly, the VO 2 reading of 391.67 ml of oxygen consumed is indicative of the amount consumed by the subject in the last 30 seconds. The RER at the same point in time is determined to be 0.7768. Page 8 of 8