Materials : Brass body dezincification-resistant

Similar documents
Materials : Brass body dezincification-resistant up to DN1 1/4

DN 65 to 100 R.F. PN10 flanges + 5 C + 65 C Max Pressure : 10 Bars Specifications : Brass check valve Controlable With valves DN1/2

DN 1/4" to 3" Female BSP - 10 C C Max Pressure : 25 Bars ( up to DN 1 ) Specifications : Anti blow-out stem With PTFE packing Full bore

Materials : Stainless steel ASTM A351 CF8M

DN 1/2" to 2" Female / Female BSP - 5 C + 60 C Max Pressure : 5 Bars Specifications : Anti blow-out stem Double o ring NBR on stem Full bore

DN 3/8" to 4" Female BSP - 10 C C Max Pressure : 16 Bars up to DN 2 Specifications : Removable stainless steel filter Female / Female

DN 1/2" to 2" Female BSP + 0 C C Max Pressure : 16 Bars Specifications : Stainless steel removable filter Female / Female With draining valve

DN 1/2" to 2 Female - Female BSP - 20 C C Max Pressure : 16 Bars Specifications : Rotating non rising stem Inside screw stem Full bore

Materials : Forged carbon steel A105N

Forged stainless steel ASTM A182 F316

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron body

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron body

Materials : Forged carbon steel A350 LF2

Materials : Forged carbon steel A105N

Materials : Stainless steel ASTM A351 CF8M

Materials : Forged carbon steel A105N

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron EN GJL 250 body. Reinforced lug for DN200 :

Ref GAS WAFER BUTTERFLY VALVE. Model/Ref:

Materials : Carbon steel ASTM A216 WCB

ACCREDITED. Technical specifications series

CALEFFI. Reduced pressure zone backflow preventer. 574 series 01022/18 NA D E C F B D E. Function

Serie ECO 3T. Threaded end back flow preventer with controllable reduced pressure zone. made in. Application fields. Protection E U R O P E

Serie ECO 3F. Flanged back flow preventer with controllable reduced pressure zone. made in. Application fields. Protection

Installation, commissioning and servicing instructions

Size : Connection Ends : Min Temperature : Max Temperature : Materials : Cast iron body

Mounting and operating instructions EB 2530 EN. Self-operated Pressure Regulator. Pressure Reducing Valve Type M 44-2

STAINLESS STEEL OVERFLOW VALVE TYPE 417

Filling valves AL, ALM Series Automatic filling units ALOMDIW, ALOMDNW Series

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

Materials : Galvanized steel flanges

553 Series.

Materials : Electro galvanized steel flanges

STAINLESS STEEL LOW PRESSURE REDUCING VALVE LPRV ELITE

differential pressure regulating valve - threaded

Installation and operating instructions KEMPER Backflow Preventer BA Figure 361

Size : Ends : Min Temperature : Max Temperature : Materials : Galvanized steel flanges

Versions. Benefits. Balancing DN15-32 DN40 DN50 DN15, DN20, DN25, DN32, DN40, DN50. Dimensions

Reduce pressure zone device suitable for high and medium hazard rated applications BSP screwed connections

VALVCHEQ BACKFLOW PREVENTERS FIGURE RP03

TECHNICAL DATA ANTI-FLOOD DEVICE MODEL B-1 1. DESCRIPTION

High Performance BSP Dial Up Pattern Pressure Reducing Valve

Anti-flood device Model B-1

Materials : Dichromate zinc plated steel flanges or AISI 316

TECHNICAL CATALOGUE PRESSURE REDUCING VALVES EUROPRESS

TECHNICAL DATA CAUTION

RHPS Series RD(H)F40 User Manual. Read the complete manual before installing and using the regulator.

Self-operated Pressure Regulators for special applications

Installation, commissioning and servicing instructions

PRESSURE REDUCING VALVE EUROBRASS 143 FF

KTM 50 (DN ) Installation, maintenance and operating instructions

Mounting and Operating Instructions EB 3017 EN. Self-operated Regulators

TECHNICAL CATALOGUE PRESSURE REDUCING VALVES EUROPRESS

Differential pressure and flow controller (PN 16) AVPQ - return mounting, adjustable setting

Installation, Operating and Maintenance Instructions. V914 Cast Iron Flanged Swing Check Valve V914

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

Art PRESSURE REDUCER

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

Installation, commissioning and servicing instructions

PRESSURE REDUCING VALVE EUROBRASSBLU CR FF

Pressure Reducing Valve for Steam Type 2333 A

AVP-F. p setting range (bar) Code No. 003H6200

OPERATING INSTRUCTIONS

Mainsboost Installation, Operation & Maintenance Instructions

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

Materials : Dichromate zinc plated steel flanges

RD(H)20/25 Pressure-Reducing Regulator User Manual

Product Manual B-Safety ClassicLine & PremiumLine Emergency Eyewash and Eye/Face Wash Equipment

GUKO FDA. einfach. gut. beraten.

TECHNICAL DATA. Page 1 of 12

CAST IRON SAFETY VALVE TYPE 6301

C 10 Pressure Reducing Valve

Function. Code Automatic filling units with pressure gauge connection Size 1/2 Code Automatic filling units with pressure gauge Size 1/2

Mounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator

THE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv)

GUMMIKOMPENSATOR GKF8000 / GKF8130

2-port seat valves PN25 with externally threaded connections

Rapidmain Installation Guide

WE SAY: CLEANLY SEPARATED SYSTEMS = ELKO-MAT EDER!

MZX. Three-Port Seat Valves SPECIFICIATIONS AND GUIDE TO SELECTION

Pilot Check Valve: Metal Body Type

CALEFFI. Pre-adjustable pressure reducing valves with self-contained cartridge series 01085/17 GB. replaces 01085/14 GB

MULTIFUNCTIONAL CONTROL FOR GAS BURNING APPLIANCE

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

VALFONTA INSTRUCTIONS: OPERATION AND INSTALLATION PRESSURE REDUCING VALVE MODEL PRV44

RS(H)20, 25 USER MANUAL

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401

4/2 way Pneumatic Solenoid Valve

Water Weir Flow Controller. Introduction. Safety Precautions. Mounting the Hardware

PRO SINK -R 1 and 2. Dilution system CONTENTS

Pressure regulator for water

Speed control assembly model A-1

Pressure relief valve DHV 712 DN 65-80: 0,5-10 bar, DN : 0,3-4 bar, DN 100: 0,5-6 bar

TECHNICAL DATA. Pressure Regulation 531a. April 24, 2009

Installation and Operating Instructions Bypass Flow Meter DST

Installation Operation Maintenance. Bermad Level Control Valve with Modulating Horizontal Float Pilot valve One Way Flow IOM.

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Type Type Differential Pressure Regulators (opening)

DS06D,G Dial Set Pressure Regulating Valve

Installation, operation & maintenance manual - original version

Pressure relief valve DHV 716 set range: 0,5-10,0 bar

Transcription:

Size : Ends : Min Temperature : Max Temperature : DN 1/2" to 3/4" Female female BSP + 5 C + 65 C Max Pressure : 10 Bars Specifications : Brass body dezincification-resistant Non Controlable With female union Materials : Brass body dezincification-resistant *the installation defects and wear defects are not covered by the guarantee Page 1 sur 10

SPECIFICATIONS : Respect the flow direction indicated by an arrow on the body Horizontal position Female / female BSP Non Controlable Low head loss With female union Strainer included 10 years manufacture warranty (the installation defects and wear defects are not covered by the guarantee) USE : Water distribution Min Temperature Ts : + 5 C Max Temperature Ts :+ 65 C Max Pressure Ps : 10 bars HEAD LOSS GRAPH : Flow Page 2 sur 10

OPERATING PRINCIPLE : The non-controllable reduced pressure zone backflow preventer, CA type comprises: a check valve upstream (1); a check valve downstream (2);a discharge device (3).The two check valves mark the limits of three different zones, in each of which there is a different pressure: upstream or inlet area (A);intermediate zone, also known as the zone of different pressure (B); downstream or outlet zone (C). The discharge device (3) is located in the intermediate zone. The discharge device (3) is connected directly to the diaphragm (4). This mobile assembly is opened and closed by the difference in pressure between upstream and downstream of the check valve and by the counter spring (5). Normal flow conditions : Under correct conditions of flow, both check valves are open, while the pressure in the intermediate chamber (B) is always lower than the pressure upstream (A) due to a calculated loss of head at the first check valve (1).As a result, this pressure difference acts on the internal diaphragm(4) and generates a force that keeps the drain valve closed (3), communicating with the atmosphere, pressing on the counter spring (5). No flow conditions : The check valves (1) and (2) are now closed. Due to the difference in pressure that still exists between the upstream zone (A) and the intermediate zone (B), the discharge valve (3) remains closed. Upstream pressure loss : As the pressure upstream decreases, both the check valves close. The discharge valve (3) opens at the moment in which the difference in pressure p, existing between the upstream (A) and intermediate areas (B) reaches a value just below the one calculated for the counter spring (5). Drainage continues until the intermediate chamber of the backflow preventer is empty. This creates a (safety) air zone and prevents the contaminated water of the circuit, coming from zone (C), from returning into the water distribution mains if the downstream check valve (2) fails. When the situation returns to normal (upstream pressure higher than the downstream pressure), the discharge valve closes again and the backflow preventer is once again ready to work. Page 3 sur 10

OPERATING PRINCIPLE ( SUITE ) : Downstream pressure increase : If the pressure in the downstream zone (C) increases until it exceeds the upstream pressure value (A), the check valve (2)closes, thus preventing the water that has already been sent to the user from flowing back towards the water main. Should check valve (2) have a slight problem with seal, or in general should any other malfunction occur in the backflow preventer, the latter will always shut off (disconnect) the connection between the user and the water main. The backflow preventer has been made with all the constructional features typical of positive acting devices; this means it ensures that optimum safety conditions are maintained in all situations. RANGE : Female - female BSP cylindrical with female union from DN 1/2 to DN 3/4 Ref.940 MATERIALS : Item Designation Materials 1 Body Brass dezincification-resistant CW602N according to EN 12165 2 Seat Brass dezincification-resistant CW602N according to EN 12164 3 Check valves POM 4 Spring Stainless steel 5 Diaphragm NBR 6 Gasket NBR 7 Strainer Stainless steel 8 Evacuation support Plastic Page 4 sur 10

SIZE ( in mm ) : SIZE WITHOUT FITTINGS : Ref. DN 1/2" 3/4" DN1 1"1/4 1"1/4 L 119.5 119.5 L1 76 76 940 H 113.5 113.5 W 54 54 Ø D 40 40 Ø F 44 44 Weight (in Kg) 1.04 1.02 Page 5 sur 10

STANDARDS : Fabrication according to ISO 9001 : 2008 DIRECTIVE 97/23/CE : Products excluded from directive ( Article 1. 3.2 ) French water agreement A.C.S. N 14 ACC LY 084 Approval Belgian certificate BELGAQUA N 08/153/CA Approval Holland certificate KIWA N K 6381/05 Approval Swiss certificate SVGW N 9212 2876 Approval Swedish certificate SITAC N SC0934-09 Designing according to NF P 43.009 et EN 14367 Threaded female BSP cylindrical ends according to ISO 228-1 ADVICE : Our opinion and our advice are not guaranteed and SFERACO shall not be liable for the consequences of damages. The customer must check the right choice of the products with the real service conditions. Page 6 sur 10

BACKFLOW : Potable water fed from the mains supply may suffer from hazardous pollution caused mainly by contaminated fluids from plumbing systems flowing back directly into the mains supply. This phenomenon, termed backflow occurs when: a) the pressure in the mains system is less that in the plumbing circuit receiving the supply (back syphonage). This situation may occur when there is a pipe breaking in the mains system or when demand on the mains supply from consumers is very heavy. b) the pressure in the plumbing circuit receiving the supply rises (back pressure) due, for example, to water being pumped from a well. Risk assessment. Given the potential dangers of the phenomenon and the requirements of current regulations, the risk of pollution from backflow must be assessed on the basis of the type of system and the characteristic of the fluid that flows in it. An appropriate backflow prevention device must be selected on the basis of that assessment performed by the system designer and the mains supplier. The device must be located along the supply line at those points at risk of backflow which would be hazardous to human health. The protection can be provided by inserting a backflow preventer at critical points in the circuit at the inlet from the mains supply or in the internal plumbing system. This will prevent polluted water from flowing back in all systems for which direct connection to the mains or an internal supply is considered hazardous. Page 7 sur 10

BACKFLOW PREVENTER USE, TYPE CA ( According to EN 1717 and EN 14367 ) : Proper use of the CA type backflow preventer is regulated by the new European standards on prevention of pollution from backflow. The reference standard is EN 1717: 2000 Protection against polution of drinking water in water systems and general requirements for the devices used to prevent pollution by backflow. In this standard, the water in the systems is classified according to the level of risk it represents for human health. Category 1 : Water used for human consumption provided by a water company. Category 2 : Fluid that does not present health hazard, as per 1, the quality of which has been compromised due to changes in temperature, taste, odour or appearance. Category 3 : Fluid that represents a slight health hazard due to the presence of one or more harmful substances. Category 4 : Fluid that represents a health hazard due to the presence of one or more toxic or very toxic substances or one or more radioactive, mutagenic or carcinogenic substances. Category 5 : Fluid that represents a severe health hazard due to the presence of microbiological or viral elements. According to this classification, suitable backflow prevention devices must be inserted in water distribution systems.ca Type backflow preventers are used to protect against risk of contamination by waters of up to category 3. For water of category 4, it is necessary to use a backflow preventer of BA type. For water of category 2 on the contrary it is sufficient to use a controllable check valve of EA type or a controllable double check valve of EC type. The table given below, named Protection matrix, associates the various types of system with the relative categories of fluid, and has been drawn up based on the indications provided in the European standards. Standard NF P 34.009 and the new European standard EN 14367 Devices to prevent pollution by backflow of potable water. Non-controllable backflow preventer with different pressure zones. Family C Type A establishes the functional, dimensional and mechanical requirements that must be satisfied by noncontrollable backflow preventers with different pressure zones of CA type. Page 8 sur 10

INSTALLATION : The backflow preventer unit must be installed horizontally after a shut-off valve upstream and an inspectable filter; another shut-offvalve must be installed downstream. The unit must be installed in an accessible area that is large enough to prevent it getting submerged by any accidental flooding. In addition there must be adequate waste pipe for medium drained from the unit to flow away. Before installing the backflow preventer it will be necessary to clean the piping with a high-capacity jet of water. Poor cleaning of the system can easily impair the operation of the unit. For the protection of the public mains the disconnection unit must be installed after the water meter, whereas in order to protect the tap water outlets of the internal network it should be installed at the limit of the areas where there may be contamination, for example: central heating, watering gardens, etc. Operating control procedure 1.Drain control operation. When there are drops in pressure in the water supply mains, therefore upstream from the valve, the drainvalve must open and let the water contained in the valve body runout: Close the shut-off valves upstream and downstream (4). Open the upstream control cock (2). The water contained in the valve body should now flow out,indicating that the device has tripped and has opened the drainvalve. 2.Check the seal of the second check valve. When back pressure is applied on the downstream side of the valve, the second checkvalve must close to prevent the water from flowing back: Close the shut-off valves downstream and upstream from the disconnection unit. Open the upstream control cock (2). Install a by-pass hose joining the control cock (1) to the other control cock (3) downstream and open them both to carry the mains pressure downstream of the second check valve. No water must come out of the drain valve, thereby indicating that the second check valve does not leak. Page 9 sur 10

INSTALLATION INSTRUCTIONS GENERAL GUIDELINES : Ensure that the check valves to be used are appropriate for the conditions of the installation (type of fluid,pressure and temperature). Be sure to have enough valves to be able to isolate the sections of piping as well as the appropriate equipment for maintenance and repair. Ensure that the valves to be installed are of correct strenght to be able to support the capacity of their usage. INSTALLATION INSTRUCTIONS : Before installing the check valves, clean and remove any objects from the pipes (in particular bits of sealing and metal) which could obstruct and block the valves. Ensure that both connecting pipes either side of the check valve (upstream and downstream) are aligned (if they re not,the valves may not work correctly). Make sure that the two sections of the pipe (upstream and downstream) match, the check valve unit will not absorb any gaps.any distortions in the pipes may affect the thightness of the connection,the working of the check valve and can even cause a rupture.to be sure,place the kit in position to ensure the assembling will work. Before starting the fitting, ensure that the threads and tapping are clean. If sections of piping do not have their final support in place,they should be temporarily fixed.this is to avoid unnecessary strain on the check valve. The theoretical lenghts given by ISO/R7 for the tapping are typically longer than required,the lenght of the thread should be limited, and check that the end of the tube does not press right up to the head of the thread. For the sealing assembly check valve piping, it is essential to use products that are compatible with the requirements of the French water agreement ACS : plumbers hemp proscribed. If mounting on an air conditioning with PER tubing and hoses,it is necessary to support the tubes and hoses with the fixing to avoid strain on the check valve. When screwing the check valve, ensure that you only rotate on screwed side by the 6 ended side.use an open ended spanner or an adjustable spanner and not a monkey wrench. Never use a vice to tighten the fixings of the check valve. Do not over tighten the check valve.do not block with any extensions as it may cause a rupture or weakening of the casing. In general,for all check valves used in buildings and heating,do not tighten above a torque of 30 Nm. If there is a direction changing or if there s another material, it s better to take away the check valve so that it is outside the turbulence area ( between 3 and 5 times the ND before and after ). After a pump please refer to norm NF CR 13932 to install the check valve. Page 10 sur 10