TANKTRONIC. STANDARD CONFIGURATION Single Tank. ADVANCED CONFIGURATION Multiple Tanks. Twin Tank (common valve) Twin Tank (separate valves) Vent box

Similar documents
COLD WATER STORAGE CONTROL AYLESBURY DELAYED ACTION FLOAT-ACTIVATED VALVES

Specification Catalogue

COLD WATER STORAGE CONTROL AYLESBURY TM FLOAT VALVE RANGE

SCIENCE LAB UTILITY CONTROLS

ECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION

DESIGN AND PRE - INSTALLATION INFORMATION

Hydraulic Valve Installation Guide

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

Aquavar SOLO 2 Frequently Asked Questions

IBU3 Manual Addendum 1

Pneumatic high-pressure controller Model CPC7000

Hydraulic Valve. Installation guide. Please keep this booklet for future reference.

BUBBLER CONTROL SYSTEM

from Thames Cryogenics Ltd Total Cryogenic Solutions Cryogenic Cluster Day 22/09/2010

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units Digital Range

The Next Generation for Level Control. By Ryan Spooner, Singer Valve

Highest Quality. Gas Chlorination Systems

AutoChanger Installation & User Guide Issue 2

Ventam 85 Installation & Commissioning Instructions

1 STARTUP Overview Buttons Basics of Control Resetting Faults and Alarms OPERATION...

Burner Management System DEMO Operating instructions

ACV-10 Automatic Control Valve

WATER MADE EASY MARINE ENERGY MUNICIPAL INDUSTRIAL

SINGLE VALVE WITH LOW-FLOW BYPASS

Installation Instructions / Operating & Maintenance Manual Midi-Fill Digital Pressurisation Unit Models MFD15 & MFD22

955730_1 4/17/18. FlowSense Operator s Guide For Gen2 20/20 SeedSense Displays

BUBBLER CONTROL SYSTEM

WATER CONTROL SYSTEM QUICK START

Stand-Alone Bubble Detection System

HEATEC TEC-NOTE Publication No Revised

Pneumatic high-pressure controller Model CPC7000

Screw Compressors 11-22kW

Municipal Boost w/pre-treatment Monitoring System K-A-MCB-PRE

Required Indoor Draft Hood. Optional Outdoor Vent Cap

Fio 2.2 Smart add-on for gas pressure Regulators

AUTOMATIC GAS MANIFOLDS

Electronic Single and Twin Pump System Pressure Managers

UNLOADING PROCEDURE OF AN AIRFLOW CONTAINER

HYPOXIC AIR FIRE PREVENTION SYSTEM TECHNICAL SPECIFICATION

V10K GAS FEED SYSTEM WALLACE & TIERNAN PRODUCTS

SENSAPHONE APPLICATION NOTE. Functions: C Programming, Pump Control, Data Logging

SAPCON. User Manual. Capacitance Continuous Level Indicator. . Introduction. . General Description. . Principle of Operation. .

ME-GI. MAN Diesel & Turbo. ME-GI Design, June 2012 Presentation for Croatian Register, 30 th August MAN Diesel & Turbo JNA/LDE

AFDXXX(X)AC Series Operators Manual Please read this manual thoroughly before attempting to operate your water maker.

Tank Level Sensors. AVTECH offers normally closed (NC) and normally open (NO) versions of the Water Tank and Fuel Tank Level Sensors.

LENNOX SLP98UHV DIAGNOSTIC CODES

TABLE OF CONTENTS TECHNICAL DOCUMENTATION 03

CONTROL and INSTRUMENTATION

Copeland Discus with CoreSense Diagnostics January 2011

Operation & Maintenance Manual

Tightness controls TC 1 3 and TC 4

OPERATING INSTRUCTIONS Pressure Control System PCS-20 through PCS-100

Concentrate Distribution System (Stand Mounted) A-CDS-70-X & A-CDS-TANK-X-ST Industrial Drive, Orlinda, TN 37141

UBEC 1AT. AUTO TANK Fill System Installation, Operation, & Setup Instructions

CONDUCTIVITY POINT/S LEVEL SWITCH JAYCEEAQUA 4000 SERIES

SP-110 Autopilot OPERATION

Flamco Airfix D-E. Installation and operating instructions. 1999, Flamco eps

Installation and Operating Instructions for Blow Down Controller Type LRR 1-12

PHOENIX L300i Best-in-class Helium Leak Detectors

CSO/STORMWATER MANAGEMENT. HYDROVEX HHV-E Vortex Driven Regulator

FAULT CODE TROUBLESHOOTING INDEX

KELCO F60 DIGITAL PUMP CONTROLLER

AUTO PUMP STATUS CENTER

SSI Solaris 150 RTA Revision /27/2016 Page 1 of 9. SSI Solaris 150 RTA

Winter Shut Down Procedure

System Pressure Manager Standard & System Pressure Manager Plus

k valve 2 (50)HF 2½ (65)SF installation guide aylesbury For valve sizes (DN): tel fax

User Manual 1 P a g e Rev. V1.6-EN 11/08/2014

(51) Int Cl.: A61B 1/00 ( )

CORROSION AT THE AIR-WATER INTERFACE REMOVE THE GAS

Manifolds & pressure reducing sets

MODEL 269DF-LCF-LCF/WS FILLING SYSTEM

Net$ync II. Net$ync II. System Controllers

Dräger PSS 7000 SCBA Self-Contained Breathing Apparatus

TANK MANAGER FOR TWO TANKS OPERATING MANUAL. 10/31/11 C-More T6C L color touch panel

MP15 Jockey Pump Controller

Specifications and information are subject to change without notice. Up-to-date address information is available on our website.

EasySas. The most advanced airlock electronics on the market. Recyclable product. Eco-design. Energy savings

KERAFLO. Guide to the UK Water Supply Regulations. The AylesburyTM Float Valve Range. ..%1111.1mr - In%

SCIENTIFIC DATA SYSTEMS, INC. Depth Tension Line Speed Panel. DTLS Manual

2600T Series Pressure Transmitters Plugged Impulse Line Detection Diagnostic. Pressure Measurement Engineered solutions for all applications

Float Valve Function and Design Considerations

FUEL GAS FIRING CONTROL RJ (Dick) Perry Safety Systems Consultant 6 June 2016

Note: You will need a full tank of CO2 for connection and leak testing! Kit Number

Temperature Controller CC24-7 ULTRA USER S MANUAL Legion Dr. Mason, MI USA October 2010 Ph. (517) Fax (517)

VALVE CRITICALITY MODELING

Technical

EasyTouch. Because automation makes it all so simple. Pool and Spa Control Systems. by Pentair Water Pool and Spa

Design Envelope Booster. Sequence of operation

ROYTRONIC EXCEL TM Series AD Electronic Metering Pumps

FCO750 LEAK DETECTOR

Remeha Quinta Cascade guide

Chemistry - Scale-up F.32. Lara TM - Controlled - Lab Reactor. The Concept

PROPORTIONING VALVE. Model 150 INSTRUCTION MANUAL. March 2017 IMS Company Stafford Road

Pressure Automated Calibration Equipment

The Air Liquide Gas System Equipment Brochure

GV Standard X-Vent. Setup, Commissioning & Installation Guide

Connect with Confidence NO POWER NO PROBLEM

Products for Cryogenic Applications

Transcription:

TANKTRONIC STANDARD CONFIGURATION Single Tank control unit Twin Tank (common valve) control unit Twin Tank (separate valves) control unit ADVANCED CONFIGURATION Multiple Tanks control unit S-Module

Tanktronic works with any valve Tanktronic and Keraflo delayed action float valves Tanktronic can be used in conjunction with a standard Aylesbury delayed action float valve, either as a retrofit or part of a new installation. This solution provides monitoring functionality and alarms and the benefits of variable delayed action filling. A control valve can be fitted as an optional back-up system to control the incoming supply in the unprecedented event of float valve failure. Tanktronic and electro-mechanical control valves The system can be used to manage tank filling by using a Tanktronic electro-mechanical control valve. When the water level reaches the pre-set high (Close Level) or low (Open Level) levels designated by the customer, a signal will be sent to the close or open the valve(s) accordingly. The difference between the Close Level and Open Level maintains delayed action filling and gives maximum water turnover rate. Tanktronic and standard equilibrium valves Tanktronic can be used in conjunction with a standard equilibrium valve, either as a retrofit or part of a new installation. This type of installation offers monitoring functionality and alarms and can be used in a range of tank configurations. AYLESBURY TM FLOAT VALVE RANGE K and KAX s Suitable for smaller tanks without raised valve chambers, the Aylesbury K Type is synonymous with float valve excellence. KB s The unique design of the KB valve provides superior performance and offers great advantages for larger tanks. KP s The KP valve is designed specifically to handle large flow rates. The KP valve comprises an in-line control valve together with an Aylesbury KB acting as a pilot. Keraflo Limited, Unit 1, Woodley Park Estate, 56-69 Reading Road, Woodley, Reading, Berkshire, RG5 3AN, UK 0118 921 9920 info@keraflo.co.uk www.keraflo.co.uk A subsidiary of Davidson Holdings Ltd.

COLD WATER STORAGE CONTROL TANKTRONIC DIGITAL TANK MANAGEMENT SYSTEM

THE MODERN SOLUTION TO MONITORING AND controlling WATER STORAGE TANKS Tanktronic is an electronic tank management system which monitors water levels and temperature. It can also manage and control tank filling and feeds this information back to your Building Management System. The user-friendly system, which is quick to install, offers a complete cost-effective solution to water monitoring. n Monitors and controls water level and temperature n Supports single and multiple tanks n Input and output device connectivity n Quick-start feature with intuitive interface n Alarms, failsafe and holiday schedule functionality Control Unit The primary monitoring and control hardware for the Tanktronic system. The unit can manage up to 4 x individual tank sensors and 2 x control valves plus additional 3rd party devices. The unit can manage up to four individual tanks. Features and Benefits n Holiday Schedule feature enables users to vary tank capacity to match demand. n Each tank can be set with its own operating levels to follow up to 10 x schedules; close level, fill delay, alarm level high and low, temperature high and low. n A two-stage alert feature for high / low water levels and temperature : A second stage override takes evasive action if first stage alert is not responded to. n Switchable mode setting between Normal, Holiday schedules and Auto operation. n Set-up wizard allows standard set-ups to be configured quickly and easily. n Simple menu navigation with key status information (fault and alarm log data) displayed.

Power The unit operates on a 230V/50Hz single phase supply from a switched fused 3A supply. Tanktronic only requires a single power connection to the Control Unit, while the additional modules do not require a separate supply. The optional Battery Module can provide back-up power if required. Control Tanktronic can control up to 4 x separate tanks. This can be up to 4 x single tanks, 2 x twins or 1 x twin + 1 x single. Adding the S-Module will allow additional pilot valves and 3rd party devices to be added. Outputs The Control Unit features 4 x volt-free contact output ports. Two are dedicated to operation, while two outputs can be used for a variety of 3rd party devices, including: n Additional filling valves n Low level alarm n Dump valve n Secondary shut-off valve n Immersion heater n Pump override Inputs Modular options A range of options allows Tanktronic to support any design of tank layout. The plug-in modules also give the system enhanced functionality and convenience as required by the user. In addition to the standard Input, The Control Unit features 2 x additional input connection ports. These volt-free contacts permit the fitment of 3rd party devices such as leak detection or an emergency override button.

TANKTRONIC OPTIONS The core components of the standard system are the Control Unit (MCU) and pressure & temperature. For added convenience, the Repeater Panel enables remote monitoring and control. The system can be expanded to meet specific requirements; Control s can be connected for tank filling, additional s and S-Module for multiple chambers and a Battery Module for back-up power. Repeater Panel Works as an interface extension to the MCU, allowing the user to programme, monitor and control the Tanktronic system up to 100m from the water tank(s). The unit does not require a separate power supply. S-Module An expansion module that can boost the Tanktronic control capacity. Adding the S-Module will allow an additional 2 x pilot valves to be controlled and extra 3rd party devices to be connected to the Tanktronic system. Battery Module Provides back-up power to the mains supply, providing up to two days of normal operation before power is expended. A recommended option if the building application is particularly dependent on the Holiday Schedule function. Control (Flanged) The Keraflo works with Tanktronic to provide tank filling. The features a flanged fitting suitable for pipe sizes ranging from 2 to a 6 bore. Control (Compression) The Keraflo works with Tanktronic to provide tank filling. The features a PVC fitting suitable for pipe sizes ranging from 3 4 to a 1 ½ bore. The monitors both water pressure and temperature. The unit is provided pre-fitted to a vent box for rapid mounting and wiring connection. Available as either a single or twin sensor unit with either 3m or 5m cable.