EFFECTS OF OUTGASSING FROM SOME MATERIALS ON GAS CHAMBER AGEING

Similar documents
EUROPEAN LABORATORY FOR PARTICLE PHYSICS STUDY OF AGEING AND GAIN LIMITS OF MICROSTRIP GAS CHAMBERS AT HIGH RATES

Mar Capeans CERN. Invited review talk at the International Workshop on Aging Phenomena in Gaseous Detectors

Analysis of RPC Performance with Different Gas Mixture

Design and Construction of a GEM-TPC Prototype for R&D Purposes

The Resistive Plate Chamber detectors at the Large Hadron Collider experiments. Danube School, September 8-13, 2014 Novi Sad

arxiv: v1 [physics.ins-det] 6 May 2016

ARTICLE IN PRESS. Nuclear Instruments and Methods in Physics Research A

arxiv: v1 [physics.ins-det] 16 Aug 2014

Aging and materials: Lessons for detectors and gas systems

Aging of Gaseous Detectors: assembly materials and procedures

Plasma Sources and Feedback Control in Pretreatment Web Coating Applications

Introduction of Vacuum Science & Technology. Diffusion pumps used on the Calutron mass spectrometers during the Manhattan Project.

MIL-STD-883G METHOD

EFFECTS OF LASER WINDOW DEGREDATION ON LASER POWER AND DISTRIBUTION IN LASER SINTERING. Ben Fulcher, David K. Leigh

SUMMARY OF THE EXPERIMENTAL STUDIES OF COLD HELIUM PROPAGATION ALONG A SCALE MODEL OF THE LHC TUNNEL

Performance of a triple-gem detector for high rate charged particle triggering

A Longterm Aging Study of the Honeycomb Drift Tubes of HERA-B Using a Circulated and Purified CF -Gas Mixture

Additives that prevent or reverse cathode aging in drift chambers with Helium-Isobutane gas *

WP2 Fire test for toxicity of fire effluents

Resist round robin ELETTRA

The Experts in Vacuum Solutions

On the possibilities for the readout of gas scintillation detectors for neutron scattering applications

ATLAS RPC QA results at INFN Lecce

QUALIFICATION OF SUB-ATMOSPHERIC PRESSURE SENSORS FOR THE CRYOMAGNET BAYONET HEAT EXCHANGERS OF THE LARGE HADRON COLLIDER

DEVICES FOR FIELD DETERMINATION OF WATER VAPOR IN NATURAL GAS Betsy Murphy MNM Enterprises 801 N. Riverside Drive Fort Worth, Texas 76111

Assembly and measurements of a mechanical prototype of the BIS MDT chamber

Experiment GC : Analysis of BTEX by GC-FID

Max Planck Institute, Munich. January 10, Because of the concern about long-term silicon contamination of MDTs, we

Effects of the electric field on the electron drift velocity in a double-gem detector in different gas mixtures

ETCHING OF COPPER COATED MYLAR TUBES WITH CF4 GAS. Karl M. Ecklund, Keith W. Hartman, Michael J. Hebert, Stanley G. Wojcicki

LCLS Heavy Met Outgassing Tests * K. I. Kishiyama, D. M. Behne Lawrence Livermore National Laboratory

The Broadest Gauging Line in the Industry

Gases&Technology. Measurement of Impurities in Helium Using the Dielectric Barrier Discharge Helium Ionization Detector. FEATURE.

Relative Dosimetry. Photons

Practical approach and problems in in-situ RGA calibration

Effects of materials on aging rates in wire chambers operated with DME

Go/no-go test for the acceptance of components for unbaked vacuum sectors

Badan Jadrowych Nuclear Research Institute. Report INR No. 739/XIX/D CERN LIBRARIES, GENEVA CM-P Differential Recombination Chamber

Victoreen B. Operators Manual. Image Intensifier Ion Chamber

arxiv: v1 [hep-ex] 18 Sep 2012

METHOD 21 - DETERMINATION OF VOLATILE ORGANIC COMPOUND LEAKS. 1.2 Scope. This method is applicable for the

Development of small, easy to build and low gas consumming timing RPCs

BEST KNOWN METHODS. Transpector XPR3 Gas Analysis System. 1 of 6 DESCRIPTION XPR3 APPLICATIONS PHYSICAL INSTALLATION

Detector Carrier Gas Comments Detector anode purge or reference gas. Electron Capture Nitrogen Maximum sensitivity Nitrogen Argon/Methane

3. Coupled Techniques in Thermal Analysis

Inert Atmosphere Guide

OxiQuant S. Operating Instructions

Three Columns Gas Chromatograph Analysis Using Correlation between Component's Molecular Weight and Its Response Factor

Development of Cleaning and Processing Techniques for UHV/XHV at Daresbury Laboratory Keith Middleman

STEAM STERILIZABLE POLAROGRAPHIC OXYGEN ELECTRODE

Detecting sound wave of bubbles produced in a boiling liquid

Gas Clean. Filters. Delivering Clean Gases for GC and GC/MS Operation

Development of high pressure-high vacuum-high conductance piston valve for gas-filled radiation detectors

Dissolved Oxygen Guide

Choosing a Quadrupole Gas Analyzer Application Note #9

USE OF TIRE PRESSURE TO IMPROVE THE CALIBRATION OF THE BICYCLE W...

Time Pressure Dispensing

ELEVATION CORRECTION FACTORS FOR RADON MONITORS*

Vacuum Science and Technology in Accelerators

Characteristics and Production of Gas Sealed, Radiation Hard, Small Ionization Chambers

This educational seminar discusses creating, measuring, and troubleshooting Rough Vacuum.

METHOD 3C - DETERMINATION OF CARBON DIOXIDE, METHANE, NITROGEN, AND OXYGEN FROM STATIONARY SOURCES

HYDROGEN - METHANE MIXTURES : DISPERSION AND STRATIFICATION STUDIES

Operating Characteristics and Handling Manual for the NAP-55A / NAP-50A Explosive/Flammable Gas Sensor NEMOTO

A Journal of Practical and Useful Vacuum Technology. By Phil Danielson

METHOD 25A - DETERMINATION OF TOTAL GASEOUS ORGANIC CONCENTRATION USING A FLAME IONIZATION ANALYZER

A variable-pressure constant-volume method was employed to determine the gas permeation

ISO/TR TECHNICAL REPORT. Natural gas Calibration of chilled mirror type instruments for hydrocarbon dewpoint (liquid formation)

A Depletion Compensated Wet Bath Simulator For Calibrating Evidential Breath Alcohol Analyzers

Atmospheric Pressure. Conceptual Physics 11 th Edition. Atmospheric Pressure. Atmospheric Pressure. The Atmosphere

Alice TPC Review Short Summary

NC Department of Insurance Office of the State Fire Marshal - Engineering Division 325 N. Salisbury St, Raleigh, NC

LUMAZOTE T ECHNICAL BRO CHU RE

Study of Mixed Gas Flow Pattern Inside RPC

DISSOLVED GAS ANALYSIS OF NATURAL ESTER FLUIDS UNDER ELECTRICAL AND THERMAL STRESS

no peaks missing peaks too small peaks increasing retention decreasing retention

Glass tube flowmeters Series 2000

Runs Solution Temp. Pressure zero reset

What hull material types will the system work on? Do I still need an antifoul paint?

Pressure measurement. Absolute pressure D Gauge pressure C Atmospheric pressure

Preliminary results of Resistive Plate Chambers operated with eco-friendly gas mixtures for application in the CMS experiment

LINEAR TRANSFORMATION APPLIED TO THE CALIBRATION OF ANALYTES IN VARIOUS MATRICES USING A TOTAL HYDROCARBON (THC) ANALYZER

Figure 1 The LHC cryogenic islands and plants layout

Level switches Series LD Vibrating fork level switch for liquids and solids

The Principles of Vacuum Technology

Generating Calibration Gas Standards

Numerical Tools for LCLS-II Vacuum Systems

Retention Time Locking: Concepts and Applications. Application

Laser-Induced Bubbles in Glycerol-Water Mixtures

The Polyethylene Casing as Diffusion Barrier for Polyurethane Insulated District Heating Pipes

LaserSnake Underwater Laser Cutting Phase 1 TWI

Performance of the Liquid Hydrogen Target

Experimental Analysis on Vortex Tube Refrigerator Using Different Conical Valve Angles

LECTURE 9 1. CARE AND PRECAUTION OF X-RAY TUBE 2. X-RAY TUBE AGING KAAB

EXPERIENCE WITH A PRE-SERIES SUPERFLUID HELIUM TEST BENCH FOR LHC MAGNETS

11/22/ (4) Harmonization: <846> SPECIFIC SURFACE AREA

ARTICLE IN PRESS. Nuclear Instruments and Methods in Physics Research A

Instrumentation & Data Acquisition Systems

Liquid level instruments BM 24 /BM 51

Guideline for RMO Key comparison for Air kerma rate in 60 Co gamma radiation

Transcription:

EUROPEAN ORGANIZATION FOR NUCLEAR RESEARCH CERN PPE/94 111 10 June 1994 EFFECTS OF OUTGASSING FROM SOME MATERIALS ON GAS CHAMBER AGEING R. Bouclier, M. Capeáns, C. Garabatos, F. Sauli and K. Silander * CERN, Geneva, Switzerland ABSTRACT Several different materials that might be used for assembling Micro-strip gas chambers (MSGCs) for high luminosity experiments were tested by measuring the gain of an irradiated wire counter when each sample was put into contact with the gas upstream of the detector. The results show a fast effect on the gain of the counter for some of the materials tested, whereas others, like Stesalit, Vectra, and the epoxy Epotek 505, do not seem to emit dangerous vapours, even at high temperatures. *) Present address: Laboratório de Instrumentação e Física Experimental de Partículas, Coimbra, Portugal. 1

2 Submitted to Nuclear Instruments and Methods in Nuclear Research

1. Introduction Radiation hardness is an important condition for gaseous detectors expected to operate in high-luminosity collider experiments such as at the Large Hadron Collider (LHC), since they will be exposed to high particle rates for years. For example, the Micro-strip gas chambers (MSGC) designed for this machine are expected to receive, during each year of operation, maximum doses of 0.02 C/cm of strip. Amongst the most critical items that affect the lifetime of gaseous detectors are the materials used in the construction of the detector itself, and in the gas station and tubing. This is because many non-metallic materials outgas some vapours which, transported with the gas flow, may be deposited directly on the surface of electrodes and insulators in the chamber, and/or favour the polymerization of radicals in the avalanche plasma, leading to the growth of deposit layers on the irradiated regions. In both cases, the lifetime of the detectors can be seriously shortened. Figure 1 [1] illustrates the dramatic effects of the choice of assembly materials in the gain stability of an MSGC. The rate of the drop in the gain as a function of the absorbed dose on the cathode strips increases by orders of magnitude simply by adding some organic materials in contact with the gas, the rest of the conditions in the irradiation tests being identical. For obvious reasons (such as the radiation length across the apparatus and the need for electrical insulators) the use of glues, plastics, or organic materials (rigid or flexible) is unavoidable in a practical detector. It is therefore mandatory to test each selected and otherwise optimal material for spontaneous, polluting outgassing, even before verifying possible additional outgassing effects caused by the exposure of the sample to ionizing radiation. Table 1: List of materials tested with some basic properties Material Type Resistivity ( 10 15 Ω cm) Araldit a) AW 106 HV 953 U Linear dilatation coef. ( 10 6 o C 1 ) Density (g/cm 3 ) 1.2 0.95 Epotek b) E.505 1.1 Duralco c) 4525 1 64 1.9 Duralco c) 4461 10 64 1.2 Stesalit d) 4411 W 3 11.5 1.8 Vectra e) C 150 > 5 7 1.8 Ryton f) R4 10 29 1.67 a) Produced by CIBA GEIGY (Switzerland). The epoxy is a modified resin based on Bisphenol A; the hardener is a polyaminoamide modified with a tertiary amine. b) Produced by ÉPOTECNY Vélizy (France). It is a two-compound epoxy resin. 3

c) Produced by Cotronics Corp. (USA). They are two-compound room temperature curing epoxy. d) Produced by STESALIT AG (Switzerland). It is a synthetic material reinforced with glassfibre. e) Produced by CELANESE (USA). It is a liquid cristal polymer. f) Trademark name of PHILIPS Petroleum Co. (USA) for polysulphur phenylene. It is a crystaline aromatic polymer consisting of para-substituted benzene rings connected by a single sulphur ion. In this paper we present the results of tests for a few epoxies and rigid materials which are suitable for the assembly of gaseous detectors, and in particular for MSGCs. Table 1 summarizes some of their physical properties. In order to test them, each material was introduced into a so-called outgassing box that was arranged in series in the gas inlet line of a single-wire proportional counter [2]. The test consisted of irradiating the proportional counter and periodically monitoring the detector performance (gain, energy resolution) as a function of the charge collected on the anode wire. Eventually, in order to speed up the rate of possible outgassing from a given sample, the outgassing box was heated. This was motivated by the fact that one should try to produce volumes of pollutants outgassed during several years of LHC operation in a few days or weeks. Unfortunately, the scaling factor of this relationship is not known. 2. Experimental set-up Figure 2 shows schematically the stainless steel gas system used to carry out the ageing tests, which has been described elsewhere [3]. The gas mixture flows into the outgassing box (closed with an aluminium flange) where the sample material is introduced, and then enters two identical single-wire proportional counters; the first one is the chamber being tested and is heavily irradiated with an X-ray generator, and the second counter, which receives a moderate dose, is used for correcting the variations of the gain measured in the test chamber caused by ambient changes. A gas chromatograph (GC) is used for analysing the gas as it flows out of the test chamber. Although the electron capture detector (ECD) used to detect possible impurities in the gas does not identify them unless a specific calibration is performed, it is useful for detecting and monitoring impurities released by the samples. The ageing tests were usually started by irradiating the test counter for a few days with a collimated X-ray beam (charge rate of a few hundred nc cm 1 s 1 ), and by keeping the sample in the outgassing box at room temperature. If the gain of the counter stayed stable during this period of time, the outgassing box was heated up to a temperature of about 50 o C with the use of a resistive heating ribbon wrapped around it. The test was stopped when either a reasonable amount of charge was collected at the anode with no change in gain, or as soon as any ageing sign was clearly detected. The gas mixture during all tests was Ar DME H 2 O [90 10 0.8]. Previous ageing tests under optimal conditions [3] in the same set-up showed that the addition of some water vapour to the mixture prevents the ageing of the counters. The operating gas gain was 10 4. 3. Results We give below the results of the ageing tests performed with the abovementioned materials. A summary of each test is provided in Table 2. An attempt has 4

been made to characterize the rate of ageing with a parameter which does not depend on the particular amount of collected charge in each case. The following expression: G G 0 =a-r" Q, where a is a constant of value 1, was phenomenologically found to yield a parameter R" [(C/cm) 1/2 ] which expresses the variation in the relative gain, G/G o, per 1 C/cm of collected charge with little dependence on the value of Q. It should be noted that the rates of ageing measured in these accelerated tests are underestimated, owing to its known dependence on the rate of charge collected at the anode per unit length [3 5]. Material Surface (cm 2 ) Table 2: Summary of results of the tests performed Weigh t (g) Temperature of test ( o C) Accumulate d charge a) (C/cm) R" [(C/cm) 1/2 ] Effect b) Araldit 176 44 55 0.015 0.67 G.L. Epoxy E.505 131 3.5 50 0.164 0.038 N.C. Duralco 4525 156 4 25 0.037 1.26 G.L. Duralco 4461 156 4 25 0.005 0.44 G.L. Stesalit 380 90 75 0.240 0.047 N.C. Vectra 142 19 50 0.249 < 0 N.C. Ryton 336 67 50 0.107 0.21 G.L. a) Only when the sample was embedded in the gas. b) G.L. = Gain loss; N.C. = No change. 3.1. Araldit This is a very popular epoxy used extensively in the assembly of frames, wires, etc. of gaseous detectors. The samples used were a few blocks of the mixture Araldit AW 106 with 80% of HV 953 U hardener, polymerized in an oven at 70 o C for two days. The ageing test was started keeping the outgassing vessel at room temperature. As shown in Fig. 3, the relative gain in the test chamber (measured from the current drawn by the high voltage power supply) decreases when the vessel is temporarily heated. When 0.09 C/cm were collected in the wire the sample was removed from the outgassing box and the gain recovered gently. The ECD showed an extra peak when the sample was in the vessel, with a larger area at higher temperature, indicating the presence of a certain impurity released by this particular epoxy. 3.2. Epoxy E.505.SI This is also a two-component epoxy, which was polymerized at 80 o C in about 30 minutes. A few glass slides were coated with the sample and introduced into the outgassing box. Figure 4 shows the result of the corresponding ageing test. Even at high temperatures, the gain of the counter does not show significant changes. Indeed, a small peak showed up in the ECD chromatogram when the sample was heated, 5

indicating that something was being outgassed (at least at 50 o C), but did not affect the performance of the detector. 3.3. Duralco Two types of this epoxy, 4525 and 4461, were tested. Their main characteristic is that they polymerize in air at room temperature, in a few hours. This property would make it possible to assemble detectors with materials having different expansion coefficients (see Table 1), as one could avoid having to heat the assembly. Unfortunately, the results of the gain stability tests, shown in Figs. 5 and 6 for Duralco 4525 and in Fig. 7 for Duralco 4461, are quite negative. As soon as the sample is put in the vessel (shaded areas in the figures), always at room temperature, the gain drops quickly and the energy resolution degrades significantly. Every time the gas was made to flow through the outgassing box after it had been opened to introduce or remove a sample material, the air contained in the box momentarily affected the gain of the proportional counter. The fast response of the detector gain to the outgassed pollutants suggests that these impurities might stick directly onto the electrode surfaces, thus screening the electric field. At some point, depending on the amount of material coating the electrodes, the detector may or may not recover its original behaviour by, for example, polymerizing these deposits, etching them away with further avalanches, or neutralizing the screening effects by increasing their conductivity, possibly due to the presence of the water in the gas mixture. 3.4. Stesalit Stesalit is a high quality fibreglass used in the construction of frames and support structures for gaseous detectors. A few pieces of this material, previously cleaned with alcohol and baked in the oven at 80 o C, were used as a sample for an ageing test. The result is shown in Fig. 8; no gain drop was noticed even when the vessel is heated at 75 o C over 0.1 C/cm accumulated in the anode wire. 3.5. Vectra This is a rigid material that has attractive mechanical and radiation hardness properties [6], and is a good candidate for use as insulating assembly material. In the corresponding ageing test (see Fig. 9), no gain drop was detected in the counter after a long exposure of the sample to the gas at 45 50 o C. 3.6. Ryton This rigid material can be moulded into assembly pieces for gaseous detectors, and is mechanically radiation hard [7]. It has a relatively high thermal expansion coefficient (see Table 1) and is therefore not compatible with epoxies that need to be heated if other materials such as glass are used in the detector assembly. In Fig. 10 the relative gain of the chamber is shown as a function of the collected charge. The gain drops when the sample is in the heated vessel, and recovers when the Ryton is removed from it. Evidence of an impurity associated with the sample was found from the gas analysis made during the ageing test, as indicated in the figure. 4. Conclusions 6

We demonstrated that there are some materials (such as Stesalit, Vectra and the epoxy Epotek E.505) that produce no significant pollutant outgassing even when heated at moderate temperatures, and thus do not affect the lifetime of gaseous detectors. These materials are suited for assembling MSGCs in high-luminosity experiments. No success has been obtained in attempting a combination of materials that may be assembled at room temperature. 5. Acknowledgements The authors would like to acknowledge G. Million and M. Jeanrenaud for their technical support, and A. Breskin, R. D'Alessandro, T. Meyer and V. Pojidaev for kindly providing some of the samples referred to in this work.

6. References [1] R. Bouclier et al., Ageing studies with micro-strip gas chambers, CERN PPE/94 63 (1994). To be published in Nucl. Instrum. Methods. [2] A. Acewski et al., RD 10 Proposal, CERN/DRDC/90 40 DRDC/P9 Rev. Nov. 1990. [3] R. Bouclier et al., Results of wire chamber ageing tests with CH 4 - and DME-based gas mixtures, CERN PPE/94 40 (1994). Nucl. Instrum. Methods A 346 (1994) 114 119. [4] A. Algeri et al., Some results on HPC ageing with brass and graphite cathodes, CERN DELPHI/92 103 CAL100 (July 1992). [5] A.F.J. den Boggende et al., J. Sci. Instrum. Ser. 2, Vol. 2 (1969). [6] L. Dobrzynski et al., The prism plastic calorimeter: PPC, CERN/DRDC/90 72, DRDC/P18 (1990). [7] H. Schönbacher and A. Stolarz-Izycka, Compilation of radiation damage test data, CERN 79 08 (1979). 8