PVK OPEN LOOP PUMPS. Bulletin E

Similar documents
PVV Open Loop Pumps. Bulletin E

Sauer Danfoss Series 90 Hydraulic Axial Piston Pump

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10

SERVICE INSTRUCTIONS P-2NN/H DUAL PRESSURE COMPENSATOR WITH HORSEPOWER LIMITER, SERIES F1U CONTROL

PVQ 13 A2 R SE 1 S 20 C-11 D

DENISON HYDRAULICS vane pumps - single, double T6G - T67G - T6ZC

SERVICE INSTRUCTIONS PVWJ A-FRAME PUMPS -011/-014/-022 FOR TYPE P-C AND P-K SOFT START PRESSURE COMPENSATING CONTROLS

SERVICE INSTRUCTIONS P-2 DUAL PRESSURE COMPENSATOR, SERIES F1U CONTROL

SERVICE INSTRUCTIONS P-C SINGLE PRESSURE - SOFT START, SERIES F1U CONTROL

SERVICE INSTRUCTIONS P-1NN/G HORSEPOWER LIMITER WITH LOAD SENSE, SERIES F1U CONTROL

Displacement 12, , Maximum flow rate (at 1450 rpm) bar.

SERVICE INSTRUCTIONS P-A OR P-B ELECTRONIC PRESSURE COMPENSATOR, SERIES F1U CONTROLS

Axial piston pumps type PVC

Axial piston pumps type PVC

PRESSURE COMPENSATORS TECNORD

SDM to 8 sections monoblock valve D1WWDA02A

SERVICE INSTRUCTIONS PVWJ A-FRAME PUMPS -011/-014/-022 FOR TYPE P-1NN AND P-LNN PRESSURE COMPENSATING CONTROLS

directional control valve series cv691

APPLICATION. Conveyors Metal working machines Machines for agriculture Road building machines Mining machinery Food industries

PLD 03 T A CASAPPA S.p.A.

Proper Pump Installation Practices

SERVICE INSTRUCTIONS PVWJ B-FRAME PUMPS -025/-034/-046 FOR TYPE P-1NN/F/J/K AND P-LNN/F/J/K LOAD SENSING CONTROLS

OMS, OMT and OMV Orbital Motors. Technical Information

HYDRAULIC MOTORS MTM APPLICATION OPTIONS CONTENTS EXCELLENCE GENERAL

Directional Controls

Load Controls Screw In Cartridge Valves Pressures to 350 bar (5000 psi) Flows to 190 l/min (50 USgpm)

Industrial Hydraulic Pumps T6EDC. We are doing our parts to keep you moving! Denison Vane Technology, fixed displacement

Full Range Pressure Compensating Variable Flow Control

DENISON HYDRAULICS T6 industrial application

420 Mobile Piston Pump Design Code B

420 Mobile Piston Pump Design Code B

Xpress L90LS Directional Control Valve. Catalog HY /UK December, 2001

Orbital Motors Type OMP X and OMR X

HYDRAULIC MOTORS MV APPLICATION GENERAL

Applications. What moves your world

Fixed Displacement Pump KFA for commercial vehicles in open circuits

DISC VALVE HYDRAULIC MOTORS

Dual displacement motor A10VM Plug-in dual displacement motor A10VE for open and closed circuit applications

Cover headline. Cover subheadline. Check Valves

E Series Piston Pumps Variable Displacement Series for Mobile Applications Technical Catalog PVE012 PVE19 PVE21

Dual Modular Safety Shutoff Valves. DMV-D/602 Series DMV-DLE/602 Series

Prop. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08

SINGLE VALVE WITH LOW-FLOW BYPASS

Vickers. Flow Controls. Flow Controls FN, F(C)G, FRG. Released 6/94

Dual Modular Safety Shutoff Valves. DMV-D/602 Series DMV-DLE/602 Series

Auxiliary Valve PRS6 Pressure Reducing Valve. Catalogue HY /UK June 2003

MESP-202H INSTALLATION INSTRUCTIONS AND OWNER S MANUAL. HF and HF FEATURES VALVE FUNCTIONS ADJUSTMENTS SCHEMATICS

1 LS unloading (control valve, orifice, none) 2 LS max pressure relief. 3 Spool type

Dual Modular Safety Shutoff Valves with Proof of Closure. DMV-D/622 Series DMV-DLE/622 Series

DENISON HYDRAULICS high performance hydraulic vane pumps single, double, triple T7 and T67 industrial application

Electrically Operated Pressure-Relief Cartridge, Size 10

L125 SERIES POST-COMPENSATED SECTIONAL LOAD SENSE VALVE

Monoblock Directional Control Valve RMB 202

Dual Modular Safety Shutoff Valves DMV-D 525/11 DMV-DLE 525/11

Dual Modular Safety Shutoff Valves with Two-stage operation. DMV-ZRD/602 Series DMV-ZRDLE/602 Series

STAND ALONE SPREADER INSTALLATION INSTRUCTIONS AND OPERATOR S MANUAL

Dual Modular Safety Shutoff Valves with NEMA 4x Enclosure DMV-D 704/604 DMV-DLE 704/604

220 Mobile Piston Pump Catalog Design Code A AEC028

Logic Elements Screw-in Cartridge Valves Pressures to 290 bar (4200 psi) Flows to 303 l/min (80 USgpm)

Model DE-1, VDE-1 and DE-2 Air Release Heads

Auxiliary valve QDS6 Sequence valve, 3-way. Catalogue (GB) (US) October 1998

Priority (Swing) Motors Data and Specifications

Variable Displacement Double Pump A20VO. Series 1, for open circuits Axial piston - swashplate design, Back to back - design

Proportional Directional Valve System

Dual Modular Safety Shutoff Valves DMV-D 525/11 DMV-DLE 525/11

Axial Piston Variable Pump A10V(S)O (US-Version)

GP1 & GP2. Electropneumatic Regulators FOR PRESSURE CONTROL TO 1,000 PSI

Dual Modular Safety Shutoff Valves with Proof of Closure and NEMA Type 4x Enclosure DMV-D 704/624 DMV-D 704/634 DMV-DLE 704/624 DMV-DLE 704/634

MOUNTING SURFACE MOUNTING POSITION MAXIUMUM OPERATING PRESSURE FLUID OPERATING VISCOSITY FLUID CLEANLINESS HYSTERESIS REPEATABILITY THRESHOLD VOLTAGE

Dual Modular Safety Shutoff Valves with Two-stage operation. DMV-ZRD/602 Series DMV-ZRDLE/602 Series

OMS Technical Information Technical data

Axial piston pumps type PVPY-C (-R, -L) variable displacement, with mechanical controls obsolete components - availability on request

Dual Modular Safety shutoff Valves with Proof of Closure and NEMA Type 4x Enclosure DMV-D 704/624 DMV-D 704/634 DMV-DLE 704/624 DMV-DLE 704/634

GFM. Typical Aluminum GFM Mass Flow Meter NIST MASS FLOW METERS. Principles of Operation. Design Features

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US

BW0500AO. ByWire Elements BW0500AO Element 4/3 with side ports IBW0500 Interface

Variable Displacement Pump A10VO

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Dual Modular Safety Shutoff Valves with Two-stage operation and Proof of Closure. DMV-ZRD/612 Series DMV-ZRDLE/612 Series

KMT Waterjet Systems Inc.

4/3 Directional valve elements L85L1...(EDC-LV) with manual lever operated control with flow sharing control (LUDV concept) L85L1...

Inverse Prop. Pressure-Relief Cart., Size 2 4

VSD03M DIRECTIONAL CONTROL VALVES

Orbital Motors OMSW with brake nose

Leak free Pipe Rupture Valve for Excavators

OMS Technical Information. Versions OMS. Versions

Dual Modular Safety Shutoff Valves with Two-stage operation and Proof of Closure DMV-ZRD/612 Series DMV-ZRDLE/612 Series

Pressure Sensing Valve - Model 4023

SKP Series SKP25 U.. Pressure Regulating Gas Valve Actuator with Safety Shut-off Function

ENGINEERING DATA. PVB Piston Pumps. w w w. F l u i D y n e F P. c o m Same Day Shipments of Units or Part Orders

Dual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure. DMV-D/624L Series DMV-DLE/624L Series

PTS1120TSJB PTS2120TSTSJB

MAKING MODERN LIVING POSSIBLE. Technical Information. Orbital Motor VMP. powersolutions.danfoss.com

Flow Dividers Type FD

Orbital Motors Type OMP, OMR and OMH. Technical Information

* Different spooltypes up to 120 l/min. in combination with simultaneously control.

Pressure reducing valve, pilot operated, Model 3DR

Displacement. from 2 up to 6 sections balanced, unbalanced from 0.8 to 31 ccm FLOW DIVIDERS

Target Cleanliness Worksheet. Systemic Contamination Control

Cartridge Valves Technical Information Proportional Valves Quick Reference

Transcription:

PVK OPEN LOOP PUMPS Bulletin 47025-E

Table of Contents Performance Assurance page 3 Features and Benefits page 4-5 Specifications page 6 Pump Controls page 7 Table of Contents Curves Performance page 8 Sound page 9 Inlet Suction/Supercharge page 10 How To Order page 11 2 Copyright 2004 The Oilgear Company All Rights Reserved

PERFORMANCE ASSURANCE STANDARD WITH EVERY OILGEAR PUMP Every Oilgear product is shipped to you with our Performance Assurance a corporate commitment to stay with your installation until our equipment performs as specified. Hydraulic equipment and systems have been Oilgear s primary business since 1921. For decades, we have developed hydraulic techniques to meet the unique needs and unusual fluid power problems of machinery builders and users worldwide, matching fluid power systems to a tremendous range of applications and industries. Our exclusive Performance Assurance program is built upon that strong foundation. As a customer, you also benefit from access to Oilgear s impressive technical support network. You ll find factory trained and field-experienced application engineers on staff at every Oilgear facility. They are backed by headquarters staff who can access the records and knowledge learned from decades of solving the most difficult hydraulic challenges. When your design or purchase is complete, our service is just beginning. If you ever need us, our Oilgear engineers will be there, ready to help you with the education, field service, parts and repairs to assure that your installation runs smoothly and keeps right on running. Performance Assurance 3

PVK Open Loop Pumps Control interchangeability. Facilitates changes, from stock, on the machine in the field. 1 Cylinder mounted polymerous journal bearings. Enables operation with low viscosity or other special fluids. Provides infinite bearing life. Permits compact design. 2 4 Optional minimum volume stop. Features and Benefits Quiet valve plate design. Minimizes noise at typical electric motor speeds. 5 Thru-shaft availability. 6 100% thru-shaft capability. (PVK 140 only; PVK 270/370 is 50%) Enables multiple pump installation from a single shaft. Permits pump to drive auxiliary devices. 7 Hardened cylinder surface running on hardened valve plate ( hard-on-hard ). Provides greater resistance to contamination. Facilitates long life. Allows operation with low viscosity or other special fluids. Steel shoes running on hardened 8 swashblock surface. Facilitates a higher degree of contaminate resistance. Permits higher pressure operation with long life. Allows operation with low viscosity or other special fluids. 4

3 Swashblock and saddle with special polymerous bearings. Allows running on low viscosity or other special fluids. Permits consistent control reaction. Eliminates troublesome yoke bearings. Provides long life. 9 Maximum volume stop (standard). 11 12 Sealed front shaft bearings. Allows operation with low viscosity or other special fluids. Permits side loading. SAE keyed or SAE splined shaft. Features and Benefits 10 Patented pressure lubricated swashblock design. Provides high performance for high pressure cycling operation. 5

SPECIFICATIONS NOMINAL DIMENSIONS UNIT SIZE LENGTH WIDTH HEIGHT WEIGHT FACE MOUNTING in. mm. in. mm. in. mm. lbs. kg. FLANGE 140 14.81 376,2 8.25 209,6 10.78 273,8 200 91 SAE D 4 Bolt 270 & 370 21.25 539,8 11.75 298,5 15.69 398,5 550 250 SAE F 4 Bolt NOMINAL PERFORMANCE SPECIFICATIONS THEORETICAL RATED MAXIMUM MAXIMUM CONTINUOUS PRESSURE MAXIMUM DISPLACEMENT PRESSURE 10% of duty cycle RATED SPEED* FLOW RATE at max. rated rpm, rated cont. pressure & 14.7 psia (1 bar abs ) inlet conditions POWER INPUT at rated cont. pressure & max. rated rpm UNIT SIZE in 3 /rev ml/rev psi bar psi bar rpm gpm l/min hp kw 140 8.61 141 5000 345 5800 400 1800 63.0 238,7 207.2 154,6 270 16.3 267 5000 345 5800 400 1500 100.0 379,0 326.9 244,0 370 22.4 367 3500 241 4100 283 1500 135.1 512,0 324.5 242,2 Specifications *Higher operating speeds may be approved. Consult the Oilgear application engineering department. PORT CONFIGURATION Shaft Left Hand Right Hand Rotation (CCW) (CW) Port A left side Pressure Suction facing shaft Port B right side Suction Pressure facing shaft H Port B W L 6

PUMP CONTROLS MECHANICAL Electronic Servo Control V A precision servo control designed to minimize hysteresis is available with several electro-hydraulic servo valve sizes to provide slow or very fast response rates. Pressure Proportional Displacement Control E The control is designed with a spring feedback so that the pump will go to a stroke setting in response to a separate pressure signal. A pressure unloading option is available. P S Solenoid Operated Dual Position RU Two adjustable deliveries as selected by an integral solenoid operated valve. Basic Pressure Compensating Control P The use of a four-way valve spool in the signal circuit allows this Oilgear Control to be adjusted to lower minimum operating pressures than other manufacturers. The Control is developed in a modular configuration facilitating the addition of multiple operators. An auxiliary port for remote pressure signal is included. A pressure compensating function is included with any of the following operators. SOL. A INTERNAL DRAIN CONN. TO PILOT PRESSURE Multiple Pressure Operators CAM One, two or there pressure adjusting operators can be added to the basic P Control. The operator can be selected by integral solenoid valves and will provide independent pressure adjustment. Flow Compensating Operator RU A module can be added to allow the pressure compensator to operate in response to the differential pressure across an orifice changing the operator to a flow compensator control. Controls Electronically Modulated Pressure Operator A proportional valve can be added to the basic P Control to regulate the compensating pressure. This operator can be used singularly or in conjunction with a pressure operator. Horsepower Limiting Operator A module can be added to all of the previously mentioned pressure sensing options to provide a control that limits horsepower as related to pump delivery. Note: Numerous P control/operator combinations are listed under How-to-Order. Please consult the factory if you have a specific requirement. 7

PERFORMANCE CURVES PVK-140 Performance Curves PVK-270 PVK-370 8

SOUND CURVES PVK-140 NOISE @ 3 ft. PVK-270 NOISE @ 3 ft. Sound Curves PVK-370 NOISE @ 3 ft. 9

PERFORMANCE CURVES PVK-140 SUCTION TEST PVK-270 SUCTION TEST Inlet Suction Curves PVK-370 SUCTION TEST 10

HOW TO ORDER BLOCK NUMBER EXPLANATION 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 / 16 VARIABLE PUMP EXAMPLE P V K 270 B1 U V L D F Y E RNN SN GS / 51 FIXED PUMPS P V K 140 A1 U V L D F S F 100 SB CP EXAMPLE P F K 140 A1 U V L D F S N NN CP 1 = UNIT P = Pump 2 = TYPE V = Variable F = Fixed 3 = DESIGN TYPE K = Type 4 = UNIT SIZE 140 = 140 ml/revolution 270 = 270 ml/revolution 370 = 370 ml/revolution 5 = DESIGN SERIES A1 = (PVK - 140) B1 = (PVK - 270 & 370) (Subject to change) 6 = DESIGN SERIES MODIFIER U B = SAE Mounting and Ports = Metric Threads w/bspp Ports (PVK-140) 7 = SEALS V= Viton (Std.) B= Buna - N E= Butyl P= EPR 8 = ROTATION L = Left hand (CCW) R= Right hand (CW) 9 = VALVE PLATE TYPE D= One-Way Service T = Two-Way Service 10 = CONNECTION TYPE F = Flange (Flanges are customer supplied) 11 = SHAFT END Y= Keyed S= Splined 12 = CONTROL TYPE & 13 = MODIFIER 12 = E = Proportional Pilot Signal Displacement Control 12 13 E R N N 13 1 = Type: A = Normally Open Proportional Device B = Normally Closed Proportional Device R = Remote (Customer Supplied Proportional Device) 1 = Solenoid Operated, One Volume 2 = Solenoid Operated, Two Volume 3 = Solenoid Operated, Three Volume 4 = Solenoid Operated, Four Volume 13 2 = Solenoid Voltage: N = None Required 0 = 115/60-110/50 VAC 1 = 230/60-220/50 VAC 2 = 12 VDC 3 = 24 VDC 13 3 = Connector: N = None Required R =.500 NPT w/o Light W=.500 NPT w/light S = PG-11 w/o Light L = PG-11 w/light 12 = F = Fixed Control 12 13 F 100 13 1= Stroke Type: 075 = 75% Stroke 100 = Full Stroke 12 = N = No Control 12 13 N NNN 13 1 = Type: NNN = No Control 12 = P = Pressure Compensating Control 12 13 P 1 N N / H 100 13 1=Pressure Compensator Options: 1 = Single 2 = Dual 3 = Triple A= Normally Open Proportional Device B= Normally Closed Proportional Device C= Single Pressure w/no Load Starting D= Dual Pressure w/no Load Starting E= Triple Pressure w/no Load Starting R= Remote 13 2 = Solenoid Voltage: N= Non Required 0 = 115/60-110/50 VAC 1 = 230/60-220/50 VAC 2 = 12 VDC 3 = 24 VDC 13 3 = Connector: N= Non Required R=.500 NPT w/o Light W=.500 NPT w/light S= PG-11 w/o Light L = PG-11 w/light (Omit if not required) 13 4= Control Modifier: F = Load Sense Option G=Load Sense w/horsepower Limiting Option H = Horsepower Limiting Option 13 5 = Input Horsepower: 100 = 100 HP Input @ 1800 rpm 12 = R = Solenoid Operated Volume Control 12 13 R U 2 R 13 1 = Type: U= Two Volume Control 13 2 = Solenoid Voltage: 0 = 115/60 100/50 VAC 1 = 230/60 220/50 VAC 2 = 12 VDC 3 = 24 VDC 13 3 = Connector: R=.500 NPT w/o Light W=.500 NPT w/light S= PG-11 w/o Light L = PG-11 w/light B=.500 NPT Conduit Box 12 = V = Electrohydraulic (w/feedback) Control 12 13 V S25 13 1 = Type: M20 = Servo Valve Size 20 M40 = Servo Valve Size 40 (PVK-270/370 only) S25 = Servo Valve Size 25 S50 = Servo Valve Size 50 (PVK-270/370 only) RNN = Remote Valve Control 14 = VOLUME STOPS SN = Maximum Volume Stop (Standard) SB = Minimum & Maximum Volume Stop 15 = COVER PLATE OR ADAPTERS CP = Cover Plate, (Standard without Auxiliary Pump) *AS = Short Adapter for Mounting PVWH-04, 06, 10 (SAE A 2-Bolt) *BS = Short Adapter for Mounting PVWH-11, 15, 20 (SAE B 2-Bolt) *CS = Short Adapter for Mounting PVWH-25, 34, 45, 60 (SAE C 2-Bolt) AL = Long Adapter for Mounting PVWH-04, 06, 10 (SAE A 2-Bolt) BL = Long Adapter for Mounting PVWH-11, 15, 20 (SAE B 2-Bolt) CL = Long Adapter for Mounting PVWH-25, 34, 45, 60 (SAE C 2-Bolt) *GS = Short Adapter for Mounting 51 Gear Pump (SAE B 2-Bolt) GL = Long Adapter for Mounting 51 Gear Pump (SAE B 2-Bolt) * See DS-47927 for Adapter Mounting Limitations 16 = OPTIONAL AUXILIARY PUMPS 51 = Gear Pump 5.10 cipr (85 ml/revolution) (2000 psi) 31 = Gear Pump 3.10 cipr (51 ml/revolution) (2000 psi) How to Order 11

World Headquarters The Oilgear Company 2300 South 51st Street Milwaukee, WI USA 53219 phone: 414/327-1700 fax: 414/327-0532 www.oilgear.com For more information about your application or the products in this brochure, please contact your nearest Oilgear facility. AUSTRALIA Oilgear Towler Australia Pty. Ltd. BRAZIL Oilgeardo Brazil Hydraulica Ltd. CANADA The Oilgear Company FRANCE Oilgear Towler S.A. GERMANY Oilgear Towler GmbH INDIA Oilgear Towler Polyhydron Pvt. Ltd. Towler Automation Pvt. Ltd. ITALY Oilgear Towler S.r.l. JAPAN The Oilgear Japan Company KOREA Oilgear Towler Korea Co. Ltd. MEXICO Oilgear Mexicana S.A. de C.V. SPAIN Oilgear Towler S.A. TAIWAN Oilgear Towler Taiwan Co. Ltd. UNITED KINGDOM Oilgear Towler Ltd. UNITED STATES OF AMERICA The Oilgear Company Bulletin 47025-E Revised March, 2004 Printed in USA