the allround-talent for your bidirectional Doppler sonography

Similar documents
CONSUMER MODEL INSTALLATION GUIDE

TYMP Technical data. at 85, 95 und 105 db HL. 2. detailed display symbols

Technology. In the My Files [My Files] submenu you can store all the programs that you have made on the NXT or downloaded from your computer.

TOMI PRO MODEL PERSONAL MODEL

Basic - Peripheral Vascular Assessment VASCULAR DOPPLER PHOTO-PLETHYSMOGRAPHY PULSE VOLUME RECORDING ANKLE AND TOE BRACHIAL INDEX

Software Manual for FITstep Pro Version 2

FireHawk M7 Interface Module Software Instructions OPERATION AND INSTRUCTIONS

ALGE DIVE! ALGE. ALGE-TIMING GmbH & Co

About us. Try us to trace your network!

Lucid System In-Service Training

Why limit your studies to the length of the cable? Pulmonary Gas Exchange (VO 2, VCO 2 ) Breath by Breath Technology

Benefits. Rev.III_032018_Oxybaby 6.0_engl subject to technical alterations

Oxidation Stability of Gasoline and Aviation Fuels

Instruction Manual Dräger MSI P7 and MSI P7 plus

Quick Start Guide. A. Hardware installation B. Software installation C. Start the software for the first time D. Do your first measurement

Callaway upro Golf GPS. User Guide (v1.3) 2009 Callaway Golf Company

Instruction Manual. BZ7002 Calibration Software BE

Chapter 6. Gas Analyser Interface. Hanatech Co., Ltd.

GAS ANALYSER OXYBABY 6.0 for O 2. or O 2 /CO 2

OXYBABY - MOBILE HAND HELD GAS ANALYSER

Oil Diagnostic Systems. Online and bottle measurement Mobile and stationary operation Lab quality accuracy e

Simulation for emergency care

Mac Software Manual for FITstep Pro Version 2

BUDDY Gorgeous and easy to use GPS Navigation Kit USER GUIDE. Love from Intempo Digital xx

HyperSecureLink V6.0x User Guide

Optical Time Domain Reflectometer. Operating System 2 Windows XPe Windows XP Pro with desktop option 256 MB

AGW SYSTEMS. Blue Clock W38X

Solutions for transcutaneous monitoring

PHOENIX L300i Best-in-class Helium Leak Detectors

OxyScan Graphic. Operating Instructions. UMS Micro-oxygen sensor 501. Microprocessor instrument

Contents. Page. Page. System Settings 10. Components 3. Basic Operation 4. Brightness. Volume (for use with sat nav software only) Play Golf

Fencing Time Version 4.3

Operating Manual. SUPREMA Calibration. Software for Fire and Gas Warning Units. Order No.: /01. MSAsafety.com

Introduction WELCOME TO LEGO MINDSTORMS EDUCATION

Code Basic module and level control complete with optionals code

Description. Measuring Device 3760XBI USP. Balancing

* Analysis of TCG ( Total Combustible Gas ) and 6 kinds of Gases * High Sensitivity for C 2

Software for electronic scorekeeping of volleyball matches, developed and distributed by:

This multi-functional device allows the determination of up to six quality parameters with only one measurement:

New Generation System M, leading the World in the Non-Invasive Measurement of Critical Real-Time Parameters.

How is SkyTrak different from other launch monitors?

PC-based systems ELOP II-NT

The S10 provides the following functions to help you take your sail training program to the next level:

MEGAS 2.0. Gas analysis with direct C-Level Calculation and Bus-Connection. Data sheet

SDM-2012 Docking Station Standalone Configuration Operator s Manual

STAND alone & p.c. VERSION

GAS ANALYSER OXYBABY 6.0 for O 2. or O 2 /CO 2. premium version

The NXT Generation. A complete learning solution

Complete Range of Force Tensiometers

Apollo Safety Features

Optical Dissolved Oxygen Meter

INSPIRE TM Inspired choice

Hand-held pressure calibrator with integrated pump Model CPH6600

GEM 2000 GAS ANALYZER & EXTRACTION MONITOR OPERATION MANUAL

TransPort PT878GC Panametrics Portable Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features

We measure it. For gas and water installers. testo hpa. bar

TransPort PT878GC Panametrics Ultrasonic Portable Gas Flowmeter. GE Infrastructure Sensing. Features. Applications

Instruction Manual Dräger MSI EM200 + EM200-i

User manual PHYSIO-PORT. Ambulatory Blood Pressure System. PAR Medizintechnik GmbH & Co. KG Sachsendamm Berlin Germany

Armfield Distillation Column Operation Guidelines

An intuitive and innovative answer to your anaesthesia challenges

Science&Motion. SAM BalanceLab. Sports. control the invisible. Most advanced pressure plate for coaching

Pressure Calibrators. Series PC..., PM...

D i s s o l v e d O x y g e n M e a s u r e m e n t

PRESENTATION OF LEAKSHOOTER LKS1000-V2 01/2017

ATMOS Diagnostic Cube

Knowledge. Improvement. Success. SAM PuttLab. 3D putt replay module

Spindles AISI 316 stainless steel spindles, easily identified by number and letter when changed according to range of viscosity.

Microsoft Windows Software Manual for FITstep Stream Version 4

Spacecraft Simulation Tool. Debbie Clancy JHU/APL

EasySas. The most advanced airlock electronics on the market. Recyclable product. Eco-design. Energy savings

Samsung SMART Hospitality Display Specification Book HE460 HE470 HE590 HE670 HE690 HE694 HE890U HE890W EU/ CIS

1001ICT Introduction To Programming Lecture Notes

Defibtech Automated External Defibrillator

Digital Pressure Gauge Main features: Data Sheet: DFP.418.R4.EN

Using the Lego NXT with Labview.

New A7 Anesthesia Workstation

Samsung Hospitality Display with Manageability - HE460

Boyle s Law: Pressure-Volume Relationship in Gases

Diver-Office. Getting Started Guide. 2007, Schlumberger Water Services

Specifications for the CMI 2409 Magnetocardiograph

EXPERIMENT 12 GAS LAWS ( BOYLE S AND GAY-LUSSAC S LAW)

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

Oxygen Meter User Manual

SVEA II GSM Connector User Manual

Table of Content IMPORTANT NOTE: Before using this guide, please make sure you have already set up your settings in

HPFM GEN3 - High Pressure Flow Meter

RaceAmerica Corporation 105 Bonaventura Drive San Jose, CA (408)

GOLF GPS Owner s Manual

Sonocaddie AUTO PLAY

For running only the scoresheet application without any video features only some very basic hardware / software requirements have to be fulfilled:

MEDIANA HEARTON AED A15. Mediana Automated External Defibrillator A15

Optical Dissolved Oxygen Meter

User s Guide Sonostar Inc.

RM-80 respiration monitor

ABS. Acoustic Bubble Spectrometer. Measurement of Bubble Size, Bubble Number & Void Fraction DYNAFLOW, INC. Research & Development in Applied Sciences

Section 2: Using the Invasive Blood Pressure Module - An Introduction

User s Guide 2010 Sonostar Inc. V _E

AUTO RANGE Display of maximum measurable limits. Displayed Info Viscosity (cp or mpa s) % Torque Spindle Speed

Operating Instructions Leak Locator HL5000

Transcription:

the allround-talent for your bidirectional Doppler sonography Storage feature for examinations Examination-Programs Voice-Message-System INT

Doppler principle Bidirectional Doppler devices are capable of identifying the bloodflow-direction in relation to the ultrasonic-probe. There is an acoustic separation between those two flowdirections (towards and away from the probe) by using two different speakers. The Doppler signal is displayed either bidirectional or as sum curve on the display or on printout. In general the orthograde flow is shown above the neutral axis and the retrograde flow is shown beneath the neutral axis. For finding out the Doppler frequency shift a so-called Zero-Crosser is used. handydop -pro the allround-talent All fields of bidirectional Doppler sonography are covered with the handydop-pro. Optional connectable ultrasonic-probes with frequencies of 4- and 8MHz make it a pro for arterial and venous function diagnosis. Its forward-looking features such as storage function, recordable and administrable voice messages and the clear menu-structure make him a professional tool for examination rooms and clinics.

Technical overview recording acoustical messages... Findings, notes, instructions can easily be recorded. headphoneconnection Using headphones the two different blood-flow directions can be heard. graphic-display (with backlight) Doppler signal and menu-functions are displayed sharp and clear. USBinterface The USB-interface is used for connecting the handydop-pro to PC-systems or a printer. keyboard The userfriendly and clear - structured keys ensure fast and efficient work with the handydop-pro. connection for battery charger For charging the handydop-pro you can either use the convenient desktop charger or alternatively the regular battery-charger by using the connection. Doppler plug-in module Ultrasonic-Module for 4- and 8 MHz ultrasonic-probes desktop charger (option) With this desktop charger the handydop-pro is automatically charged. This way your handydop-pro is always ready for use. handydop -pro Innovation by ELCAT State of the art hardwarecomponents were used while developing the handydop-pro: high-performance processor flash-disk Worldwide the handydop-pro is the first pocket Doppler based on Linux. That`s how we define innovation! handydop -pro is powered by µclinux

Workflow - examination Carrying out an examination Choosing the examination-program Doppler examinations are carried out by using an examination-program. Examinationprograms set the order of vessels that have to be examined. You can change those programs to your individual needs by using our vasoviewsoftware. You can define as many examinationprograms as you wish. Carrying out the measurement By using the Start / Stop-keys you carry out the measurement on a vessel. The speed of bloodflow is displayed on the LCD. During the measurement you can change Doppler-scale, time-basis, flowdirection-display or frequency of the wall-filter. When the complete measurement is finished, the examination-program stops. The examination is saved automatically. Dopplersignals are displayed on an LCD. The handydop-pro can store up to 100 examinations incl. voice messages. Documenting an examination Finished examinations can be printed out at a later point of time or they can be transfered - together with the voice messages - to the vasoview-software. Voice-message-system Using the integrated voice-message-system you can easily record findings or comments and instructions for assistants or colleagues during the examination. Those voice-messages can be heard anytime you like. You can also transfer them to a PC by using vasoview-software. Findings, comments, notes for letters, instructions for colleagues/assistants - just record it on the handydop-pro.

Workflow - handydop-pro - vasoview Connecting handydop-pro and vasoview handydop-pro can be connected to your PCsystem by using a USB-cable. vasoview-software automatically detects the connected handydop-pro. Right then vasoview is ready to be used. Connecting the handydop-pro with a PC via USB-interface Transferring data Examinations are transfered to a PC or notebook Data-transfer between handydop-pro and vasoview is bidirectional. This means, that on the one hand saved examinations on the handydop-pro can be transfered to the vasoview-software and on the other hand examination-programs can be transfered from vasoview-software to the handydop-pro as well. Analysing and working on data Sitting in front of your desktop you can analyse and work on examination-results. You can analyse, save and print all results you need. The voice-messages can be heard, this way you may remember important notes. Using the voice-message-system in a professional way, the efficiency of your patient-management will improve considerably. Analysing and working on examination results and voice messages Storing data Examinations can be printed out or stored in the vasoview data base of your clinic`s IT-system. vasoview-software supports connections to a clinic`s IT-system by BDT- / GDTand DICOM interfaces. The vasoview data base can be installed on a local PC or directly on the server. When installing the software on a server, you can use every workstation (equiped with vasoview) to get access to the vasoview data base.

and vasoview vasoview General information With the vasoview-software you can connect the handydop-pro to a PCsystem to transfer, analyse and print out examinations. vasoview provides a high-capacity examination-data base where all relevant data can be stored. With vasoview, examination-programs can be generated and transfered to the handydop-pro. This way examination-programs can always be adjusted to your individual needs. BDT- / GDT- and DICOM interfaces realize the software connection to your clinic`s IT. Transfering patient data and saving examination-results enhance the range of vasoview features. vasoview ONLINE Examination programs (Vessel list) help to carry out examinations. Measurements can be guided either by PC or with the handydop-pro itself. The Doppler signals are shown on the PC display during the examiation. vasoview OFFLINE Examinations which are saved in the handydop-pro can be transfered to a PC by using vasoview-software. During post processing examination-results can be analysed, printed and saved in the vasoview-data base.

suitcase gel bottle battery charger LG20 dektop charger (option) 4 MHz-Module with ultrasonic-probe handydop -pro basic device with 4 MHz-probe

technical data (technical data is subject to change without notice) Basic device Basic equipment Storrage function Energy supply - integrated speaker - LCD-display (with backlight) - headphone connection - USB-interface - connection for battery charger 100 examinations incl. voice messages can be stored. vasoview (option) technical data (technical data is subject to change without notice) Included in delivery System requirements Software Processor Hardware interface CD Pentium III, 1,6 GHz or higher USB interface 4 pieces of AAA NiMH rechargeable batteries, 1,2 V, 1000 mah, 3 h charging time, 2 h continuous operation, power management 4 MHz ultrasonic-probe 8 MHz ultrasonic-probe Accessoires Dimensions Dimensions Printer 11 x 95 mm (Diam. x Length) 9 x 95 mm (Diam. x Length) Desktop charger Sensitivity range Sensitivity range Headphone 15-55 mm 8-25 mm Cable Memory Operating system Connection cable handydop -pro / PC-system 500 MB of free disk space (Application) Microsoft Windows Additional Software interface at least 500 MB (Database) Installation instructions and BDT, GDT 2.10 and DICOM operating manual at least 512 RAM Are you interested in the handydop -pro? Then call us! We would be pleased to tell you more about your possibilities with the handydop -pro! GmbH medical systems Bgm.-Finsterwalder-Ring 27 Phone +49 08171 4214-00 82515 Wolfratshausen Fax +49 08171 4214-49 Germany E-Mail sales@elcat.de ISO 13485:2012 Homepage www.elcat.de presented by 2013-11