Redesign - ATMOS S 201 Thorax. Digital thoracic drainage systems. ATMOS Thorax MOBILITY SAFETY COMFORT FLEXIBILITY

Similar documents
Digital drainage systems. ATMOS Thorax COMFORT SAFETY FLEXIBILITY MOBILITY

ATMOS Wound Therapy. The choice is yours! ATMOS S 041 Wound ATMOS S 042 NPWT. MedizinTechnik

Chest Drainage Systems for Cardiac & Thoracic Surgery. Including portable suction with Digital Air Leak Monitoring

CONTROLLERS FOR COMPRESSED AIR AND VACUUM MEDAP-FINA SUCTION

MEDAP-MOBILE GAS SUPPLY

Optimum oxygen supply for your patients! ATMOS Oxygen Supply

ekom Compressor for Medical Air Sonata with Ekom

SATURN EVO COLOR A N A E S T H E S I A S Y S T E M. Manufacturer of high quality anaesthesia products

VENTIlogic LS VENTIlogic plus. 100 % Mobility and Reliability in IV and NIV

Negative Pressure Wound Therapy

Innovative cap to reduce the noise raised by bubbling activity drainage working (vent close)

VENTIlogic LS VENTIlogic plus. 100 % Mobility and Reliability in IV and NIV

Digital Display large color coded LED display is easy to read precise measuring shows actual cuff pressure

Tourniquet Systems Pressure Infusion

DONOR TM Pre-Evacuated Post-Operative Autologous Blood Reinfusion System

AQUADEX FLEXFLOW SYSTEM QUICK REFERENCE GUIDE

Keep the balance in sight

Entry to the premium class!

Airox Supportair Ventilator

Quiz for Module 2: Aquarius Training (Rev. 1) Lesson 1: Introduction to Aquarius

SPIROVENT VACUUM DEGASSERS

Dameca MRI 508. State-of-the-art MRI technology

AQUARIUS Continuous Renal Replacement Therapy with Regional Citrate Anticoagulation (RCA) Competency

AQUARIUS Continuous Renal Replacement Therapy Competency

MEDUMAT Standard a MEDUMAT Standard. The Ventilation Standard for Professionals

Intensa GO Alternate Care Ventilator

RM-80 respiration monitor

FOCUS - ON - PATIENTS

Instructions for use Compressed air injector with water trap

State-of-the-art anesthesia technology

Oxylog VE300 Emergency & Transport Ventilation

Dräger RZ 7000 Test Equipment

ila ACTIVVE SYSTEM PLATFORM

Innovation at its best

IEC C LASSIFICATIONS:

Making Life Easier Easypump II

Minimum size for maximum performance

QUADROX-i Neonatal & Pediatric Maximum safety for the smallest patients.

The centerpiece of a comprehensive anaesthesia workstation

Digital Tourniquets. Product Details. For electricity VAC, 50/60 Hz

Fabius Tiro TM. Designed for your environment. Because you care. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Monnal T60. Touch and Breathe.

fabian Therapy evolution Our 2-in-1 device

PHOENIX L300i Best-in-class Helium Leak Detectors

Supporting your patients every breath

Multi Fibres. MiniFant M99 insulation blowing MacHinE

Pneumatic high-pressure controller Model CPC7000

Supporting you in saving lives!

Manual. Online Degasser DDG-75. Manual Degasser DDG-75 April DURATEC Analysentechnik GmbH Rheinauer Strasse 4 DE Hockenheim Germany

M95 insulation blowing machine Reliability and power in a compact design.

EndoWorld UNITS 4-1-E/ CO 2. Insufflation

Introducing Astral. Greater freedom. Confident care. Designed efficiency

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

TOURNIQUET SYSTEMS & PRESSURE INFUSION

Organis TestChest. Flight Simulator for Intensive Care Clinicians

The next generation of Blood and Fluid Warming

CARDIOHELP System designed to save lives

Oxylog 2000 plus. Step up your performance. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Fabius Tiro TM. Designed for your environment. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Oxylog 3000 plus Emergency & Transport Ventilation

Tourniquet System. Ideal for single or bi-lateral orthopaedic surgery and pain management. AT4 Tourniquet System. Introduction.

An intuitive and innovative answer to your anaesthesia challenges

628 Differential Pressure Decay Leak Tester

UNITS /2017-E ENDOFLATOR 50. The New High-Performance Insufflator with Integrated Heating Element from KARL STORZ

New. The high security connection

BODYGUARD 2CH TWIN CHANNEL INFUSION PUMP

Your patients, our primary focus. Siesta i Whispa anesthesia machine

Blease900 Ventilator PATIENT CENTERED VENTILATION

Volumat Agilia _Volumat_Presentation_customer.ppt

Solutions for transcutaneous monitoring

KOOLKARE CAR & COMMERCIAL AIR CONDITIONING SERVICE SOLUTIONS

fabian HFO: Modular, Powerful, Versatile.

Dräger RZ 7000 Test Equipment

WHITEPAPER. Integrated process monitoring of dosing pressures

Benefits. Rev.III_032018_Oxybaby 6.0_engl subject to technical alterations

MEDAP-FLOWMETERS FOR OXYGEN AND COMPRESSED AIR

OXYBABY - MOBILE HAND HELD GAS ANALYSER

This multi-functional device allows the determination of up to six quality parameters with only one measurement:

The next generation of Blood and Fluid Warming

Quick Response Pneupac VR1 Emergency Ventilator AIRWAYMANAGEMENT

V8600 Ventilator. Integrated Invasive & Noninvasive Ventilation

OxygenatOrs QUaDrOx-i adult QUaDrOx-i small adult

Additel 761 Automated Pressure Calibrators Selection Guide

VENTILATION SERVO-s EASY AND RELIABLE PATIENT CARE

Your patients, our primary focus

Multi Channel Solutions

Monoblock Directional Control Valve RMB 202

THE UNIVENTOR 400 ANAESTHESIA UNIT

VIAFLO 96. Electronic 96 Channel Hand Held Pipettor

EVE. The mobile Ventilation Concept from Emergency to Intensive Care. easy - light - smart. Ventilation

HOW WISE TECHNOLOGY WORKS INFICON Protec P3000 sensor powered by Wise Technology, consists of an evacuated gas cell covered by a quartz membrane.

Siesta i Whispa Integrated technology

Information for patients and nurses. Rocket Ambulatory Chest Drain

The right atmosphere for health. A system for medical gas supply

Medical Instruments in the Developing World

WF STEUERUNGSTECHNIK GMBH. INFORMATION and TECNICAL DESCRIPTION

Pneumatic high-pressure controller Model CPC7000

ThopEasy + INSTRUCTIONS FOR USE. Precious life Progressive care. Thopaz. Thopaz+

Instructions for use Evacuation system compressed air injector SL 20 / SL 20 Max SL 30 / SL 30 Max

KOOLKARE CAR & COMMERCIAL AIR CONDITIONING SERVICE SOLUTIONS

Transcription:

Redesign - ATMOS S 201 Thorax Digital thoracic drainage systems ATMOS Thorax MOBILITY SAFETY COMFORT FLEXIBILITY

ATMOS We don t do anything else. But we do it differently. The combination makes it special Development always stands for progress. This applies for thoracic drainage systems which have evolved from simple bottle systems into complex devices. We have been part of this progress since the development of the first digital thoracic drainage system ATMOS S 031 Thorax in the year 2003. We have made it our aim to reduce the complexity of the device into the simplicity in operation. Thus we are convinced to support you in achieving the best possible therapy results. Our complete product portfolio ranges from simple surgical suction devices to intelligent OT-systems. Let yourself be convinced, by the long standing experience found in each of our products. 2

The option of having the water lock with the ATMOS S 201 Thorax allows the experienced nurse and surgeon to blend the two systems (analog and digital) together, and help them understand the concept of quantifying the size of an air leak digitally and visually with the bubbles. The 12 day graphing system displays the patient s therapy minute by minute due to the device s real-time vacuum. Because of the current measurement values and the high sensitivity of this system, I was able to see the patient s tidaling (max. flow/min. flow) on the graph by watching the increase and decrease of the measured curve in the graph during inspiration and expiration. Dr. Robert J. Cerfolio Chief Thoracic Surgery UAB Digital thoracic drainage systems made by ATMOS As one of the leading companies for premium surgical suction devices and ENT units, our high quality products are in use worldwide. Highly innovative products which have been developed close to our customers demands distinguish ATMOS MedizinTechnik for more than 120 years. 3

Are these problems familiar? Problems The risky siphon effect When the drainage hose is sagging, secretion accumulates at the lowest point, and cannot be suctioned by a conventional thoracic drainage system. The hereby arising secretion column decreases the vacuum at the patient. With every cm secretion column the vacuum is lowered by 1 mbar! Result: Even at -20 mbar in the secretion canister, it could be possible that there is no vacuum at the patient. Therefore the therapy won t show the desired result. Secretion hose blocked because of coagulation Especially after cardiac surgery there is a high risk of coagulum development in the drainage hose. These block the hose and prevent further therapy. Conventional drainage systems do not have the ability to rinse out the blood clots. Result: The hose needs to be milked by hand. This means more work for the nurses and unnecessary pain for the patient. Secretion hose has a kink The drainage hose can kink unknowingly for different reasons during the therapy. Result: The vacuum from the secretion canister cannot be forwarded to the patient. The vacuum in the pleural cavity is undefined and there is no drainage of air and secretion. Emergency cases and complications are not recognized or it is too late During a thoracic drainage various complications can occur. When working with conventional drainage systems you must rely on the staffs attentiveness for the early identification of possible problems.the systems have no integrated alarm system. 4

We know the solution! The ATMOS solution The elaborate ATMOS measuring & hose rinsing system ATMOS thoracic drainage systems work with a double lumen hose system. The larger lumen transports air and secretion from the drainage to the secretion canister, as conventional systems do. The smaller lumen is the rinsing and measuring hose. Measuring function The hose is connected to the sensor of the drainage unit. Siphons, coagulum or other blockages in the drainage hose have no influence on the measurement result. The pump aggregate can regulate the suction accurately in order to reach the target value in the pleural cavity. Rinsing function After a defined period a valve opens for a millisecond and vents the measuring and rinsing hose. Secretion and coagulum which have been deposited in the secretion hose will be flushed into the secretion canister. Reliable warning message systems provide early information regarding complications Digital thoracic drainage systems by ATMOS offer an elaborate warning management. The systems shows visual and acoustic warning messages, if the target vacuum in the drainage can not be achieved. the battery is too low. the therapy is inactive after start-up. the device is in a tilted position. the temperature of the device is too high. The indication doesn t only show that a problem exists, it also gives possible solutions. 5

Are these problems familiar? Problems Insufficient information of the actual therapy progress With the use of conventional systems the only way to get information regarding the therapy progress is to interpret the bubbles, observe the secretion hose and order expensive x-rays. Result: Due to this process high costs arise and the right point of time to remove the drain can only be determined imprecisely. Complex manuel documentation of the healing process Conventional systems do not offer automatic documentation of the healing process. Result: The documentation must be done manually by the nurses. This results in considerable staffing efforts. Restricted mobility due to connection to the central vacuum Conventional Bülau drainages must be connected to the central vacuum or an electrical suction device in order to create a suction. Result: The patient is spatially bound so the therapy must be interrupted during a transfer. A mobilisation under active suction is only possible to a limited extent. Disturbance due to intense bubble generation in the control canister Conventionaly two- or three-canister systems are connected to intense bubbling in the control canisters. Result: This leads to a permanent noise exposure for patients and nurses. 6

We know the solution! The ATMOS solution Digital storage of measured values ATMOS thoracic drainage systems have a complex sensor technology and an elaborate data analysis. In the display the target vacuum, the actual vacuum and the actual flow value are displayed digitally. The ATMOS C 051 Thorax offers from software version 1.1. the possibility to transfer the therapy data as PDF or excel-sheet via USB stick. From now on there is the possibility to export the therapy data via USB stick for documentation and further processing even with the ATMOS S 201 Thorax. In the long-term display the ATMOS thoracic drainage systems offer the option to show graphs of real-time vacuum and real-time flow for the past 12 days. A detailed view of therapy data is guaranteed by zooming in the graphs. Based on this graph curve a decision-making basis for determining the right time to remove the catheter is given. In addition there is the possibility to visualize coughing tests in the short-term display. Therefore, conclusions can be drawn regarding any possible air leaks. Battery operated, adjustable suction system creates mobility and safety ATMOS thoracic drainage systems are fully integratable systems. The systems contain fine adjustable, powerful suction aggregates. Due to the automatic control the aggregate always provides the exact flow which is required to maintain the target vacuum. Herewith results minimal noise exposure and a gentle drainage Due to perfected lithium-ionic batteries the units can operate up to 12 h without connection to the main power supply. Therefore, transportation of the patient from OR to the ward and the mobilization of the patient are possible without interrupting the therapy. Patient remains on suction during ambulation and transport. The recharging time for a fully discharged battery is max. 4 h. 7

ATMOS The full-range supplier In daily clinic life you are confronted with a variety of medical indications which need a thoracic drainage for therapy. Are you looking for thoracic drainage systems which you can use after thoracic surgeries as well as in emergency medicine, intensive care and cardiac surgery? Thoracic surgery and pneumology General, intensive care and emergency medicine Cardiac surgery ATMOS C 051 Thorax ATMOS S 201 Thorax ATMOS offers you the right solution for every application! With the ATMOS C 051 Thorax we offer a very compact and mobile solution for pulmonary intensive care, emergency medical care and for pneumology. With the application of the more powerful ATMOS S 201 Thorax large coagulation as well as high flow of secretion and liquids, which are typical for cardiac surgery are no problem. According to the medical indication in general, intensive care and emergency medicine both versions of the ATMOS thoracic drainage system can be used. 8

Two solutions one operating concept ATMOS thoracic drainage systems of the new generation stand out by their uniform operating concept. This prevents doctors and nurses have to adapt to two different devices. The intuitive and virtually foolproof operation supports this decisively. Flow Display of the actual fistula in ml/min or l/min Actual vacuum Display of the actual vacuum at the patient Therapy progress Changeover to graphic representation User settings Target vacuum Display of the preadjusted target vacuum Setting button Increasing the target vacuum Setting button Decreasing the target vacuum Start/ stop of therapy Key lock One hose All digital thoracic drainage systems developed by ATMOS use the same hose system. If your clinic uses various ATMOS thoracic drainage systems this offers a wide range of advantages: Easy compound management: Only one hose for all devices and all thoracic drainage applications One operating concept: The connection of the ATMOS thoracic drainage systems is also standardized Different ATMOS thoracic drainage systems can be used in combination 9

The all-rounder Automatic night mode The updated ATMOS S 201 Thorax has an automatic night mode. A light sensor automatically detects the ambient light and the device automatically switches to night mode. The result is a more pleasant sleeping atmosphere for the patient. Therapy process control On the main display of the device the target vacuum, the actual flow rate and the vacuum are displayed as a numerical value. The course of therapy is graphically displayed for 12 days. In addition it is possible to download the therapy data as PDF and excel file via USB stick for further processing. Powerful The speed-controlled 18 ± 2 l /min suction aggregate meets all application requirements. Whether strong coagulation, high secretion flow or connection of several catheters no problem for the ATMOS S 201 Thorax! Fully transparent disposable canister system 4-chamber system with inscribable scaling sticker for ideal readability and balancing in fine steps up from 10 ml. Optional fillable water lock for visualisation of flow/air leaks. Overpressure reduction is guaranteed by the integrated pop-off valve. The hydrophobic bacterial filter with integrated overflow stop is used to protect the device and the environment against penetration of fluids and contamination. Canister connection to the device by Direct-Docking-System. Gravity drainage mode The target vacuum can be reduced to -5 mbar. Thus the drainage can be performed at physiological vacuum. The advantages of digital drainage are retained. 10

11

The small marvel ATMOS C 051 Thorax Mobile & flexible Up to 16 hours of battery operation. With only 1.3 kg dead weight, an ergonomic design and a comfortable carrying strap this system is perfect for the fast mobilization of the patient. The optional 360 adjustable universal bracket allows the connection to wheelchairs, beds and infusion stands. Touchscreen The ATMOS C 051 Thorax uses a touchscreen as an input interface. As a result it was possible to create even simpler icons and to arrange the buttons in an easier and more user-friendly way. Gravity drainage mode The active suction can be set to -5 mbar. Thus the unit only preserves the biological normal vacuum and emits air and secretion. Advantages: Physiological effect like a gravity drainage The postition of the unit in the room has no effect on the drainage Warning message Hose rinsing Digital information regarding fistulization remains active Clear view of the secretion The 800 ml secretion canister of the ATMOS C 051 Thorax is divided into a 180 ml and a 620 ml compartment. This leads to ideal balancing requirements. 12

Therapy progress control On the main screen the target vacuum, the current vacuum and the current flow rates are displayed as a numerical value. The therapy progress is displayed graphically over 12 days. In addition it is possible to download the therapy data as PDF or excel file via USB stick. Automatic night mode From software version 1.1 the ATMOS C 051 Thorax has an automatic night mode. A light sensor automatically detects the ambient light and the device automatically switches to night mode. This results in a more pleasant sleeping atmosphere for the patient. 13

Secretion canisters with a difference Easy canister change Protected by a hydrophobic bacterial filter and integrated overflow stop. Sealing caps For an easy handling the caps can be found directly on the device. The use of sealing caps prevents the leakage of liquids during disposal of the canisters. Easily recognizable scaling The scales are marked on the left and right hand side of the canister. Large numbers and a high contrast ensures optimal readability. The white background and the hard surface allow for easy marking. 2 chambers for better readability Application with the hose system The hose system is connected to the canister via Luer-Lock. Only one hose for all the ATMOS thoracic drainage units. The canister is divided into two chambers, the first has a capacity of 180 ml and the second one 620 ml. 14

Luer-Lock - connection for secretion hose Pop-off valve Hydrophobic bacterial filter with integrated overflow protection Sealing caps For secretion channel For pop-off-valve 4-chambers for easy secretion balancing (in milliliters) Optional water lock Flow visualisation through bubbles 15

Specifications overview of digital thoracic drainage systems ATMOS S 201 Thorax ATMOS C 051 Thorax Max. suction performance 18 ± 2 l/min 5 ± 0,5 l/min Vacuum regulation freely selectable -5 to -100 bar in -1 mbar steps -5 to -100 bar in -1 mbar steps Battery operation up to 12 h 16 h Disposable secretion canister system 2 l 4-chambers system 800 ml 2-chambers system Hose system one hose for both systems Graphic color display Touchscreen Vacuum measurement at the patient Real time flow measurement Monitoring function in long- and short-term (flow, vakuum, time) Reading out therapy data Gravity drainage mode PDF/ excel report via USB stick Digital gravity drainage mode at -5 mbar PDF/ excel report via USB stick Digital gravity drainage mode at -5 mbar Night mode Rinsing function Mobility Universal bracket and/or carrying bag for canister Universal bracket and/or carrying strap 16

Secretion canister ATMOS S 201 Thorax ATMOS C 051 Thorax Canister volume 2000 ml 800 ml Volume of the first chamber 375 ml 180 ml Full transparency for easy readout and balancing in fine steps up from 10 ml Sealing cap for easy disposal Hydrophobic bacteraial filter with integrated overflow stop Pop-off valve for safety when coughing and by artificial respiration Water lock Luer lock connection for safe and easy connection and disconnection of the hose system Ergonomical design 17

ATMOS S 201 Thorax Accessories & consumables ATMOS S 201 Thorax Mobile thoracic drainage system of the S-class. Suitable for transport within the hospital and to accompany the patient from the surgical intervention up to the end of therapy. Fully electronic monitoring, automatic rinsing function, real-time flow measurement, flow history, data export via USB stick, warnings, night mode, ergonomic touchscreen colour display. Technical data: Pump performance: 18 ± 2 l/min Noise level: max. 31 db (A) @ 1 m (acc. to ISO 7779) Dimensions (H x W x D): 336 x 250 x 168 mm Included in delivery: Basic unit, power supply cable, operating instructions quick guide Accessories ATMOS S 201 Thorax 1 REF 312.1100.0 Universal bracket 312.1160.0 Carrying strap for ATMOS S 201 Thorax 312.0850.0 Hose clamp 061.0079.0 Hose support 312.1029.0 Consumables ATMOS S 201 Thorax 2 3 4 OR-Set for ATMOS S 201 Thorax, pu 10 312.1031.0 Hose system, pu 10 312.1170.0 Disposable secretion canister, 2 l, pu 5 312.1150.5 10x each 10x each 1 REF 312.1160.0 2 REF 312.1031.0 3 REF 312.1170.0 5x each 4 REF 312.1150.5 18

ATMOS C 051 Thorax Accessories & consumables ATMOS C 051 Thorax Mobile thoracic drainage system of the C-class. Suitable for transport within the hospital and to accompany the patient from the surgical intervention up to the end of therapy. Fully electronic monitoring, automatic rinsing function, real-time flow measurement, flow history, data export via USB stick, warnings, night mode, ergonomic touchscreen colour display. Technical data: Pump performance: 5 ± 0.5 l/min Noise level: max. 34 db (A) @ 1 m (acc. to ISO 7779) Dimensions (H x W x D): 164 x 206 x 95 mm Included in delivery: Basic unit, carrying strap, charging device, 2-pole power supply cable, operating instructions, quick guide REF 317.0000.0 Accessories ATMOS C 051 Thorax REF 1 Device bracket 316.0200.0 2 Carrying strap 316.1100.0 Consumables ATMOS C 051 Thorax REF 3 OR-Set for ATMOS C 051 Thorax, pu 10 317.1100.0 4 Hose system, pu 10 312.1170.0 5 Disposable secretion canister, 800 ml, pu 10 317.1000.0 10x each 1 REF 316.0200.0 2 REF 316.1100.0 3 REF 317.1100.0 10x each 10x each 4 REF 312.1170.0 5 REF 317.1000.0 19

Contact: ATMOS MedizinTechnik GmbH & Co. KG Ludwig-Kegel-Str. 16 79853 Lenzkirch / Germany ApplicationSolutions@atmosmed.de For further information: www.atmosmed.com P094.1833.2 2016-05 Index: 12, Errors and omissions excepted