OxyMon MkIII Optical Imaging made easy and affordable

Similar documents
as provided by other available near infrared oximeters. Moreover, OxiplexTS complements the pulse oximeter in

OptonPro. High-power laser up to 7000 mw. Laser therapy natural healing with the power of light

Local measurement of venous saturation in tissue with non-invasive, near-infrared respiratory-oximetry

Blood flow and oxygen consumption with near-infrared spectroscopy and venous occlusion: spatial maps and the effect of time and pressure of inflation

FLUORESCENCE DETERMINATION OF OXYGEN

Blood Parameter Monitoring System 550

New Generation System M, leading the World in the Non-Invasive Measurement of Critical Real-Time Parameters.

RESPIRATORY PHYSIOLOGY, PHYSICS AND

Oxygen Saturation Monitors & Pulse Oximetry

Specifications for the CMI 2409 Magnetocardiograph

Thermo Scientific Model 146i Principle of Operation

Instructions to User

Verdi G-Series. High-Power Pumps for Ti:Sapphire Lasers and Amplifiers FEATURES

Sensor. Directions For Use

FTIR Users Group Meeting FTIR development

Experiment B-18 Heart Rate and Coughing

Advanced Test Equipment Rentals ATEC (2832) OMS 600

Solutions for transcutaneous monitoring

FOURIER TRANSFORM INFRARED SPECTROSCOPY

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

D-Opto Dissolved Oxygen Sensor Operation Manual for the D-Opto 4-20mA

SOLUTIONS Homework #1

SCHEINWORKS Measuring and Analysis Systems by

Time-dependent blood flow and oxygenation in human skeletal muscles measured with noninvasive near-infrared diffuse optical spectroscopies

TABLE OF CONTENTS 1 Overview Appearance Name and Model Intended Use Feature List Important Acroynms...

BIOPAC Blood Flow Monitor

D-OptoLogger Dissolved Oxygen Logger Operation Manual

Forearm muscle oxidative capacity index predicts sport rockclimbing

RM-80 respiration monitor

Dr. Tetsuzo KITAGAWA, Tokihiko YONEDA, Shigefumi NAKAJIMA. 1. Preface

Lab #2: Blood pressure and peripheral circulation

Fingertip Pulse Oximeter

HumiSys HF High Flow RH Generator

Technology. In the My Files [My Files] submenu you can store all the programs that you have made on the NXT or downloaded from your computer.

Verdi G-Series Family

Rad-57 Pulse CO-Oximeter

Modeling the Dependency of Oxygen Saturation Levels in Tissue on the Blood Flow of Capillary Units

KNOW YOUR EQUIPMENT: Pulse oximeter Verghese Cherian Associate Professor of Anesthesiology Hershey Medical Center

SPECIFICATIONS PARTICLE SENSOR KS-18F Higashimotomachi, Kokubunji, Tokyo , Japan

Series Environmental Chambers

- How do the carotid bodies sense arterial blood gases? o The carotid bodies weigh 25mg, yet they have their own artery. This means that they have

MEASURING BLOOD PERFUSION IN BONE USING NIRS BONE OPTICAL SPECTROSCOPY. A Thesis Presented. Ali Ibrahim Alneami. The Department of

Customer Responsibilities. Important Customer Information. Cary 4000/5000/6000i UV-Vis spectrophotometer Site Preparation Checklist

P215 Respiratory System, Part 2

Technical Information Conducal CLY421

Cardiac Output Simulation for Specific Makes of Monitor. Each injection yields in a time-temperature curve whose area represents the cardiac output:

Optical Time Domain Reflectometer. Operating System 2 Windows XPe Windows XP Pro with desktop option 256 MB

AIR-X COMPACT AIR-X ON-LINE LUBRICANT AERATION MEASUREMENT. Technical Brochure ON RUNNING ENGINES

Overview. Front Panel: Keypad and Display

RESEARCH ON THE CHANGES OF THE RESCUERS HEART RATE DURING TRAINING

Rheological properties. Rheological instruments backed with rheological experience. Malvern. detailed specification sheets from

.$2;,)*3/6$ USER MANUAL

Aurora. Moisture Measurement for Industrial Gases. GE Measurement & Control

Finger Pulse Oximeter. User Manual. Innovo Medical Stafford Centre Drive Suite B Stafford, TX

PULSOX -2 INSTRUCTION MANUAL

Complete Range of Force Tensiometers

Using the Lifebox oximeter in the neonatal unit. Tutorial 1 the basics

6. Transport gases in blood

WARNING: EXPLOSION HAZARD

Genesis MX SLM-Series

2600T Series Pressure Transmitters Plugged Impulse Line Detection Diagnostic. Pressure Measurement Engineered solutions for all applications

Customer Responsibilities

Servo UNIVERSAL ADVANCED VENTILATION PLATFORM ALL PATIENT CATEGORIES

Optical Dissolved Oxygen Meter

Simultaneous two-photon imaging of oxygen and blood flow in deep cerebral vessels. Supplementary figure 1

Purpose and Scope: Responsibilities: Warnings and precautions: Background Beers law

Bold Line Top Stage Incubator

Oxidation Stability of Gasoline and Aviation Fuels

Catabolism in Skeletal Muscle The Phosphagen System

SPECIFICATIONS PARTICLE SENSOR KS-19F Higashimotomachi, Kokubunji, Tokyo , Japan

Used with Dissolution Tester for Fraction and Flow Measurements

of the Skin of Extremities

Basic - Peripheral Vascular Assessment VASCULAR DOPPLER PHOTO-PLETHYSMOGRAPHY PULSE VOLUME RECORDING ANKLE AND TOE BRACHIAL INDEX

Instruction Manual CMS-50DL

BIOGAS COMBUSTION PLANT MAINTENANCE MANUAL

WHITEPAPER. Integrated process monitoring of dosing pressures

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

Overview. 2 Module 13: Advanced Data Processing

Biomedical Sensor Systems. Laboratory

Convergent Technologys product overview

Oxygen Saturation Monitor PULSOX -2. Instruction Manual

Customer Responsibilities. Important Customer Information. Agilent Infinity II Preparative HPLC System Site Preparation Checklist

CJMJ.DPNQBDU. Instruction for use. Neonatal phototherapy device. BILI-COMPACT WY 1816/ Year of manufacture D2017_00

The three steps for biomechanical assessment are the following: > Periodically verify the results and the efficacy of treatment

A new method for noninvasive venous blood oxygen detection

What is ultrasonic plethysmography and how can we use it in airway disease?

The NXT Generation. A complete learning solution

RESPILAB USER MANUAL

Lab 3. The Respiratory System (designed by Heather E. M. Liwanag with T.M. Williams)

Minipuls evolution fitted with three 4-channel Medium Flow pump heads. one 4-channel Medium Flow pump head and one 2-channel High Flow pump head

IDeA Competition Report. Electronic Swimming Coach (ESC) for. Athletes who are Visually Impaired

D (2016) 116 (8) ISSN

CMA4000 Specifications

GasSense NDIR User Manual

MIE Medical Research Ltd Digital Analyser Pinch/Grip Instruction Manual

LUMAZOTE T ECHNICAL BRO CHU RE

Instruction Manual. BZ7002 Calibration Software BE

LEADER SEARCH RADAR LIFE LOCATOR

CO2 INCUBATOR CO2 INCUBATORS

Section 2: Using the Invasive Blood Pressure Module - An Introduction

Transcription:

Principle Near infrared spectroscopy (NIRS), the technique on which the OxyMon is based, relies mainly on two characteristics of human tissue. Firstly, the relative transparency of tissue for light in the NIRS range, and secondly on the oxygenation dependent light absorbance of hemoglobin. Using the OxyMon, being based on this principle, it becomes possible to monitor your subject: + Non-invasively + Easily transportable, bedside measurements + With continuous recording and feedback + Without the need of a special infrastructure + Without specially trained personnel + Affordable and without disposables + Without specially trained personnel + Affordable and without disposables neuroscience neonatal research brain monitoring psychological research Introduction: OxyMon MkIII All cells in all organs of the body have a constant but variable need for oxygen. However the body stores for oxygen are minimal. A constant and adequate supply of oxygen to the tissues through the circulation is essential. In critical situations therefore monitoring a subject s local tissue oxygenation can be of life-saving value. This information can be obtained with the OxyMon which utilizes the technique of near infrared spectroscopy. Being a small flexible company with more than 16 years of experience in near infrared spectroscopy we are aware of the special needs of scientists. Support with setting up your research can all be arranged.

Applications Main applications are found while monitoring brain and/or muscle tissue: + Functional brain monitoring, e.g. measuring the response of brain oxygenation to a sensory stimulus + Monitoring of regional muscle oxygenation in sports medicine or during rehabilitation training + Researching patients in the operating theatre or in intensive care units, where the oxygen supply to the brain might become critical + Neonatal research + Researching a hampered blood supply to the limbs, e.g. as seen in peripheral vascular disease + Measuring regional flow, volume and saturation + Fast optical signal

Oxysoft To save your valuable time, we have also developed simple-to-use software for data analysis, named Oxysoft, which can calculate all the parameters you are interested in. It s main features include: + Data collection + Allows for the calculation of oxy-, deoxy-, total hemoglobine and tissue saturation index (TSI) + Generating events from external inputs and optional analog input channels + Preparing of two-dimensional plots and video s of 2-D plots, very useful for brain mapping + Offline data export to Matlab and Matlab based software packages (SPM, Homer) + Realtime data export to Matlab + Methods for data analysis and statistics + Generating events from external inputs + Export to a text file, Microsoft Excel or XML Oxysoft example of data analysis

Experiments To save your valuable time, we have also developed simple-to-use software for data analysis, named Oxysoft, which can calculate all the parameters you are interested in. A 24 Channel Near Infrared Spectroscopy (NIRS) mapping measurement made with the OxyMon MkIII of a left-to-right moving object. 24 Channel NIRS Measurement of a moving object made with the OxyMon MkIII This is an unfiltered tracing of the oxygenation changes in the left visual cortex of one subject, while watching 13 blocks of a flickering checkerboard on a computer screen (see inlet in right upper corner). Each block lasts 20 seconds. Example of measurement on muscle, where an exercise period (A) is followed by an occlusion (B-C) from which the local oxygen consumption (mvo2) is determined from the gradient of the oxyhemoglobin (O2Hb) signal. Example of a functional NIRS tracing using a 12 channel setup. The optodes are placed over the left motor cortex, while the subject performs a finger tapping task with his right hand during 20 seconds, starting at t = 0 s. An increase in blood flow is observed over the motor cortex.

Technical Specifications Technology Continuous wave near infrared spectroscopy using modified Lambert Beer law. Measures Changes in oxy and deoxyhemoglobin and optionally regional tissue saturation index (TSI) using spatially resolved spectroscopy. Operating System Windows XP, Windows Vista, Windows 7 and Windows 8. Events Insert off-line events for the PortaMon, PortaLite and online events for our other devices. Channel(s) Between 1 and 96, depending on configuration and splitting of fibers. Maximum configuration is 2 x 4 cabinets with 8 transmitter/8 receiver. Minimum is one cabinet with one transmitter/one receiver. Light source(s) Temperature stabilized pulsed laser sources (Class I according to IEC- 60825-1, safety of lasers). Wavelengths Standard nominal 765 and 855 nm, others possible. Detector(s) Temperature stabilized and cooled avalanche photo diodes with ambient light protection. Sampling time From 0.1 Hz to 50 Hz (up to 250 Hz optional). Noise ~0.001 standard deviation in optical density at a total of ~6 optical densities at 10Hz measurement frequency. Storage Real-time, unlimited data storage. External inputs Optional are 8 additional analog data inputs at 50 Hz (up to 250 Hz optional), +/- 4 Volt. Optode fibers Standard 3 meter, lengths up to 10 meter available. Optode holders Multiple distances for muscle or head possible, multi-channel generally customer specific. Optode distance Depending on application. Frontal head with up to 6 cm possible with arterial pulsation still visible. For fnirs 3-4 cm is recommended. Upgrades The instrument can easily be upgraded. Power Auto sensing 110-240V, approx. 40 Watt. Dimensions Weight 7 to 8 kg, WxDxH: 37x30x9 cm. Environment Operating temp. ~10-27 ºC, both source and detector temperature stabilized, altitude 0-5750 m. Interference With NMR compatible fibers the instrument can be used inside the MRI. EEG/ECG does not interfere the optical signal. References to wireless NIRS technology Mehagnoul-Schipper DJ, van der Kallen B, Colier WNJM et. al. Simultaneous measurements of cerebral oxygenation changes during brain activation by NIRS and fmri in healthy young and elderly subjects. Human Brain Mapping 2002. 16: 14-23. Colier WNJM, Quaresima V, Wenzel R, van der Sluijs MC, Oeseburg B, Ferrari M, Villringer A. Hemodynamic changes detected simultaneously in both occipital areas by functional near infrared spectroscopy. Vision Res. 2001; 41:97-102. Colier WNJM, Binkhorst RA, Hopman MT and Oeseburg B. Cerebral and circulatory haemodynamics before vasovagal syncope induced by orthostatic stress. Clin Physiol. 1997; 17(1): 83-94. van Beekvelt MC, Colier WNJM, Wevers RA, van Engelen B. Performance of near-infrared spectroscopy in measuring local oxygen consumption and blood flow in skeletal muscle. J Appl Physiol 2001. 90: 511-519. van Beekvelt MC, van Engelen BG, Wevers RA, Colier WNJM. Quantitative near-infrared spectroscopy discriminates between mitochondrial myopathies and normal muscle. Ann Neurol. 1999;46:667-70. Quaresima V, Colier WNJM, van der Sluijs M, Ferrari M. Nonuniform quadriceps O2 consumption revealed by multipoint measurements. Biochem Biophys Res Comm 2001; 285(4): 1034-39.

2015 Artinis Medical Systems all rights reserved. All specifications and appearances can change without further notice. All other trademarks or registered trademarks are the property of their respective owners.