MEDUMAT Standard a MEDUMAT Standard. The Ventilation Standard for Professionals

Similar documents
VENTIlogic LS VENTIlogic plus. 100 % Mobility and Reliability in IV and NIV

Oxylog 3000 plus Emergency & Transport Ventilation

MEDUMAT Transport. High-End Ventilation in Any Situation

VENTIlogic LS VENTIlogic plus. 100 % Mobility and Reliability in IV and NIV

O-Two Self-Study Guide. e600 Transport Ventilator Ventilation Modes

Mobile Solutions for the Hospital

AUTOVENT 4000 VENTILATOR

Oxylog 2000 plus. Step up your performance. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Operation of Oxylog 3000 ventilator

MEDUMAT Standard a. Ventilator. Description and instructions for use

Operation and Maintenance of the EPV200 Portable Ventilator

Panther 5 Acute Care Ventilator

Airox Supportair Ventilator

SATURN EVO COLOR A N A E S T H E S I A S Y S T E M. Manufacturer of high quality anaesthesia products

Intensa GO Alternate Care Ventilator

The Crossvent 2i+ 2. Ventilator Concept (brief theory of operation and features)

Oxylog Better to have one. Because you care. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

MEDUMAT Standard. Ventilator. Description and instructions for use

Oxylog VE300 Emergency & Transport Ventilation

SLE4000. Infant Ventilator with touch-screen operation. When the smallest thing matters

A9600 Anesthesia Workstation. Your healthcare, we care.

DATA SHEET. VENTILATION SERVO-s

Supporting your patients every breath

The centerpiece of a comprehensive anaesthesia workstation

Emergency Transport and Ventilation

Technical Data and Specifications

Hospital and Transport for Controlled Breathing

Oxylog 2000 plus Emergency & Transport Ventilation

Safe Accurate Reliable. CWM-301 Anesthesia System

Dräger Savina 300 Classic ICU Ventilation and Respiratory Monitoring

Anesthesia Workstation

Dräger Oxylog 3000 plus Emergency & Transport Ventilation

Automatic Transport Ventilator

ekom Compressor for Medical Air Sonata with Ekom

Servicing and repair instructions. MEDUMAT Standard a. Ventilator WM 22800

MEDUMAT Transport. Emergency ventilator. Description and Instructions for Use for Devices from Firmware Version 2.17

SERVO-s v8.0 Data sheet

Virginia Beach EMS. Oxylator EMX. Debra H. Brennaman, RN, MPA, NREMT-P

patient education program 4156 South 52 nd Street, Omaha, NE ChildrensOmaha.org/HomeHealthcare

IEC C LASSIFICATIONS:

How Ventilators Work. Chapter 3

PERFORMANCE EVALUATION #34 NAME: 7200 Ventilator Set Up DATE: INSTRUCTOR:

SLE5000 Infant Ventilator with HFO

Basics of Mechanical Ventilation. Dr Shrikanth Srinivasan MD,DNB,FNB,EDIC Consultant, Critical Care Medicine Medanta, The Medicity

Provide Comfort to your Patients is our commitment PRODUCT CATALOGUE HOSPTIAL SUPPLIES. Copyright ReadMed Company Ltd

AUGUST ANESTHESIA MACHINES MEDICAL PRODUCTS ANESTHESIA MACHINES. Quality System Standard applied: ISO 9001, ISO 13485

Dräger Savina Sub-Acute Care Ventilation

Fabius Tiro TM. Designed for your environment. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Introducing Astral. Greater freedom. Confident care. Designed efficiency

Dräger Savina 300 Select ICU Ventilation and Respiratory Monitoring

Stephanie. Pediatrics. The ventilation system for neonatology

VT650. Gas Flow Analyzer. Technical data. Key benefits and features:

CPAP Devices - Masks - Accessories for respiratory assistance in CPAP

Pressure maintenance valve SDV-P / SDV-P-E

HAMILTON-T1 Intelligent transport ventilation for armed forces

An intuitive and innovative answer to your anaesthesia challenges

Fabius plus. The plus that makes all the difference. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Siesta i Whispa Integrated technology

EVE. The mobile Ventilation Concept from Emergency to Intensive Care. easy - light - smart. Ventilation

AkzentColor. Anesthesia. Anesthesia and excellent ventilation for neonatal, pediatric and adult patients

D Beyond essentials DRÄGER SAVINA 300 SELECT

GE Healthcare. Centiva/5 Critical Care Ventilator. Meet a new level of expectations

V8800 Ventilator System. Your healthcare, we care.

Automatic Transport Ventilators. ICU Quality Ventilation on the Street.

VENTILATION SERVO-s EASY AND RELIABLE PATIENT CARE

Completed downloadable Test Bank for Pilbeams Mechanical Ventilation Physiological and Clinical Applications 5th Edition by Cairo

Your patients, our primary focus. Siesta i Whispa anesthesia machine

2015 Hamilton Medical AG. All rights reserved. Printed in Switzerland.

Better to have one OXYLOG 3000

Expanding versatility. The upgraded Trilogy family of ventilators continues to meet the changing needs of your patients

CENTRAL GAS SUPPLY SYSTEMS : CYLINDER BATTERIES AND HIGH PRESSURE HOSES

Fabius plus. The plus that makes all the difference. Because you care. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

VENTI-O 2 plus. O 2 switching valve for: VENTImotion from serial number 4000 VENTIlogic from serial number 4000 VENTImotion 2

Operation and Maintenance of the MCV100 and MCV100-B Portable Ventilator

e700 Automatic Transport Ventilator User Manual e700 User Manual (15PL Rev.14 28_8_2017)

GE Healthcare. Aestiva/5. More than superior ventilation


Unit 15 Manual Resuscitators

Inspire rpap REVOLUTION FROM THE FIRST BREATH

INTENSIVE CARE VENTILATORS

MACS Mask CPAP System

Quick Response Pneupac VR1 Emergency Ventilator AIRWAYMANAGEMENT

Operating Instructions for Microprocessor Controlled Ventilators

Instructions for Use Oxylog 2000 plus

Your patients, our primary focus

Dräger Savina 300 Select ICU Ventilation and Respiratory Monitoring

Dameca MRI 508. State-of-the-art MRI technology

D Beyond essentials DRÄGER SAVINA 300 SELECT

e600 Automatic Transport Ventilator User Manual e600 User Manual (15PL Rev.7 28_8_2017)

NEONATAL/INFANT VENTILATOR

PRESSURE REGULATORS AND FLOWMETERS, ALL MEDICAL GASES

PERSEO EVOLUTION. workstation for gaseous anaesthesia. for adults, children and newborns. Code: OM 403 / 3 gas module 3 rotameter

LifeChoice Activox Portable oxygen concentrator. Portable oxygen therapy for patients with active lifestyles. ResMed.com

State-of-the-art anesthesia technology

Defibtech s Latest Advancement The Lifeline ARM Automated Chest Compression (ACC) Device for Professionals

Focused on essentials DRÄGER SAVINA 300

Technical Documentation Oxylog 2000 Emergency Ventilator

O-Two Self-Study Guide. Equinox Relieve

MEDAP-MOBILE GAS SUPPLY

Equinox II USER MANUAL NITROUS OXIDE/ OXYGEN 50%/50% ADMINISTRATION SYSTEM (01EQ7000E) DEMAND VALVE (01EQ7001E) O-TWO MEDICAL TECHNOLOGIES INC.

Transcription:

a The Ventilation Standard for Professionals

a The Ventilation Standard for Professionals a offers you everything you need for reliable emergency ventilation. Users around the world are impressed by its especially simple operation and ruggedness. With controlled ventilation supplied by MEDU- MAT Standard and assisted ventilation by MEDUMAT Standard a, we provide you with the ventilation options you require in an emergency. Our diverse modules let you add many supplemental functions, such as CPAP therapy, to MEDUMAT ventilators. When there s not a second to lose, the well-designed operating panel with special symbols and colors help you to quickly set the right ventilation parameters. When placed on our portable LIFE-BASE system, the a has practically unlimited mobility. Valuable benefits for your use Function expansion to meet your needs Alarm system ensures high level of safety Easy to transport Simple operation Complies with EN 1789 a WM 22800 WM 22500

Color coding Arrow system a Ventilate Reliably and Properly An advantage a and have over manual ventilation is the option of setting constant values for tidal volume, ventilation frequency and minute volume. These settings help to prevent ventilator-induced injuries*. Furthermore, with a ventilator you can reliably prevent hyperventilation and damaging pressure peaks*. That reduces the intrathoracic pressure, which in turn improves venous reflow and cardiac output*. You can keep your hands free to provide additional care to the patient. If a problem arises, the ventilator emits acoustic and visual alarms. Double stroke process Pressure Top reliability Automatic self-test when ventilator is switched on Color coding and arrow system simplifies fast and safe parameter settings for each patient group Settings for respiratory minute volume, respiratory rate and maximum ventilation pressure are infinitely adjustable Visual and acoustic alarms warn of acute problems such as stenosis, disconnection, loss of supply pressure, inadequate battery capacity, system outage, no triggering by patient (only in assisted mode in MEDUMAT Standard a ) Economical and flexible Air-Mix function reduces FiO 2 to about 60% No oxygen required for operation No external power supply necessary Can be combines with all Weinmann modules, such as MODUL CPAP P max Flow time time Pressure Flow Additional ventilation volume by means of double stroke-process Assisted ventilation with a mbar 30 20 10 Expiration window Expiration window Expiration ventilation stroke window Behavior upon achieving maximum ventilation pressure (e.g., as result of CPR) If the selected maximum ventilation pressure is exceeded, for example, during Cardiopulmonary Resuscitation (CPR), a or will briefly switch to expiration and attempt to administer a ventilator breath in the same inspiratory phase. With this double-stroke procedure, the patient receives the maximum ventilation volume. Inspiration Inspiration Inspiration impulse controlled ventilation assisted ventilation with inspiratory triggering Spontaneous respiration Time in seconds Under assisted ventilation a gives the patient a ventilator breath in response to an inspiratory trigger. When the patient s respiratory efforts reach the trigger threshold, a delivers a mechanical breath to the patient. If the patient does not trigger a breath within the window for inspiration, the patient will receive controlled ventilation. * ERC Guidelines 2010

Easy to transport Enhanced functionality with function modules Integrated oxygen supply Practical and safe storage of accessories LIFE-BASE We offer you 25 pre-configured solutions to get a and quickly and safely to the emergency site. Mobility for a and You can put together ventilation and oxygen therapy systems to fit your needs on the LIFE-BASE portable system. The extremely tough LIFE-BASE system can be carried in just one hand. For transport in a vehicle, the different LIFE-BASE models are ideally protected in the crash-proof BASE-STATION mounting. You can also conveniently carry a und in our emergency backpack RESCUE-PACK. With RESCUE-PACK on your back, you have an unobstructed view ahead and plenty of room to maneuver. On the way to the scene of an emergency, your hands are free to carry other equipment or to open doors. LIFE-BASE III with and MODUL CPAP, WM 8251 Rescue Pack I with, WM 9065

1 2 3 4 5 6 7 Accessories for and Standard a Replacement parts 1 Refitting set for device outlet filter for and Standard a WM 15780 Bacteria filter for a and WM 22162 2 Patiente hose system with patient valve for a and WM 22520 3 Patient hose system with patient valve, disposable, for a and WM 28110 Set of disposable ventilation tubes 10 pcs of WM 28110 WM 15454 Set of disposable ventilation tubes 25 pcs of WM 28110 WM 15455 Set of disposable ventilation tubes 50 pcs of WM 28110 WM 15456 4 PEEP valve with connection nozzle, infinitely adjustable settings from 2.5 to 10 mbar (22 mm exterior diameter) WM 3215 5 Reusable protective sleeve for ventilation tube for a and WM 8297 6 EasyLung for MEDUMAT WM 28625 Test set for a WM 15382 Test set for WM 15335 7 Station MEDUMAT WM 22550 Station MEDUMAT with standard rail holder WM 22670 Respiration tube, double lumen for a and WM 22647 Patient valve for a and, consisting of: Patient hose connection (WM 3213), Upper control element (WM 3181), Bottom control element with spontaneous breathing option (WM 3285), Lip membrane (WM 3211) WM 3280 Patient hose connection WM 3213 Upper control element WM 3181 Bottom control element with spontaneous breathing option for a and WM 3285 Valve membrane for expiration arm on patient valve WM 3212 Insert for spontaneous breathing arm WM 3282 Membrane for spontaneous breathing arm, red WM 3284 Lip membrane WM 3211 Set I lip membrane (25 pcs. WM 3211) WM 15320 Set II lip membrane (50 pcs. WM 3211) WM 15330 Set of batteries for a and WM 15186

Technical data a Device dimensions (W x H x D in mm): 190 x 110 x 90 190 x 110 x 90 Weight (in kg) about 1,1 about 1,1 Product class as per directive 93 / 42 / ECC: IIb IIb Operating conditions Temperature range: Humidity: Air pressure: Control: 18 to +60 C 15% to 95% 70 kpa to 110 kpa Time-controlled, volume-constant 18 to +60 C 15% to 95% 70 kpa to 110 kpa Time-controlled, volume-constant Storage temperature: 40 to +70 C 40 to +70 C Operating gas: Medical-grade oxygen Medical-grade oxygen Operating pressure: 2,7 to 6 bar * 2,7 to 6 bar * Required amount of gas: 70 l/min 70 l/min Respiratory rate: 5 to 40 (infinitely adjustable) 8 to 40 (infinitely adjustable) Ventilation modes: Controlled ventilation (IPPV), Assisted ventilation (SIMV) Inspiration : Expiration 1:1,67 1:1,67 Inspiration: Expiration (assisted) 1:1 to 1:2.3 variable Controlled ventilation (IPPV) Respiratory Minute Volume (RMV) 3 20 l/min (infinitely adjustable) 3 20 l/min (infinitely adjustable) Tidal volume: 75 to 4000 ml (infinitely adjustable) 75 to 2500 ml (infinitely adjustable) Tolerances MV Room temperature (20 C): -18 C to +60 C: for 3 l/min =± 20 % for >3 l/min =± 15 % for 3 l/min =± 35 % for >3 l/min =± 20 % für 3 l/min =± 20 % für >3 l/min =± 15 % für 3 l/min =± 35 % für >3 l/min =± 20 % Max. ventilation pressure (Pmax) 20 60 mbar * (infinitely adjustable) 20 60 mbar * (infinitely adjustable) Pressurized gas connection External thread G 3/8 External thread G 3/8 Power supply Expected service life Maximum storage No maintenance lithium battery 3.6 V; 5.2 Ah > 2 years 10 years after delivery No maintenance lithium battery 3.6 V; 5.2 Ah > 2 years 10 years after delivery Ventilation hose Spiral silicone hose NW 10 Spiral silicone hose NW 10 Degree of protection from splashing water IPX4 IPX4 Standards used EN 794-3, EN 60601-1, EN 1789, RTCA-DO160 E Alarm sound pressure 54 db (A) 54 db (A) Manometer accuracy Class 1,6 Class 1,6 Patient valve dead space volume 12,8 ml 12,8 ml EN 794-3, EN 60601-1, EN1789 RTCA-DO 160 E 83640-EN-09/2013 Copyright WEINMANN Emergency, Hamburg. Duplication of any kind only with the express permission of WEINMANN Emergency. All rights to design and specification modifications reserved. * 1 mbar = 1 hpa Simply professional You can rely on Weinmann Emergency. We set the standards for mobile solutions in patient ventilation. Our 130 years of experience and close association with professional users in emergency medical services, armies/public authorities and hospitals have led to the development of intelligent and perfectly coordinated technologies. In conjunction with the professionals in emergency, transport and disaster medicine, we pursue our shared goal of saving human lives. Would you like to know more? Call us on +49 40 88 18 96-120 weinmann-emergency.de weinmann-emergency.fr weinmann-emergency.ru weinmann-emergency.cn