CRAFTSMAN EXAMINATION, NOVEMBER 2007 GASFITTING ANSWER SCHEDULE

CERTIFYING GASFITTER

REGISTRATION EXAMINATION, NOVEMBER 2017 TRADESMAN GASFITTER QUESTION AND ANSWER BOOKLET. Time allowed THREE hours

Changes to the Gas. (Safety and Measurement) Regulations. effective 1 July 2013

Installation and maintenance of twin 45kg LPG cylinder systems

REGISTRATION EXAMINATION, JUNE 2017 CERTIFYING PLUMBER ANSWER SCHEDULE

Confined Space. Program Responsibilities

About SPK-Rifeng Gas

INSPECTION, TESTING AND CERTIFICATION OF GASFITTING WORK DONE UNDER SUPERVISION

TRADESMAN DRAINLAYER

ARCHIVED. Compliance Document for New Zealand Building Code Clause G11 Gas as an Energy Source. Prepared by the Department of Building and Housing

CERTIFYING DRAINLAYER

Confined Spaces OSHA 1926 AA

REGISTRATION EXAMINATION, NOVEMBER 2015 LICENSED PLUMBER ANSWER SCHEDULE

CAUTION Hard copies of this document may not be the current version. Refer to the "I Am The Key" verify the current version,

Forced or Mechanical Ventilation - which uses mechanical supply and/or extraction to provide fresh air and is controllable.

REGISTRATION EXAMINATION, JUNE 2015 CERTIFYING PLUMBER ANSWER SCHEDULE

Gas Conversion Kits CERAMIC HEATER SERIES (1, 2, 3, 4 Burner Units)

ACCESSORY KIT INSTALLATION INSTRUCTIONS

Shri Krishna Test House, B-70/1, Gali No. 8, New Modern Shahdara, Mansarover Park, Delhi. Discipline Mechanical Testing Issue Date

ASSIGNMENT 2 CHE 3473

ASSIGNMENT 2 CHE 3473

Integral type Differential pressure flowmeter VNT Series

TABLE OF CONTENTS PART 2 - CONFINED SPACES

ACCESSORY KIT INSTALLATION MANUAL

POTENTIAL HEALTH & SAFETY HAZARDS

ISO INTERNATIONAL STANDARD. Small craft Liquefied petroleum gas (LPG) systems

Gas Injection Systems

The Johns Hopkins University/The Johns Hopkins Hospital Health, Safety and Environment Manual Safety Policies:

Your safety and the safety of others are very important.

University of Dayton Respiratory Protection Program 29 CFR

Vehicle- or rack-mounted liquefied gas meters, pump supplied

STANDARD OPERATING PROCEDURE

EH&S Program Occupational Safety Next Review: 5/9/19. Scope: University Wide Original date created: 2006

About. providing superior performance and reliability. Bromic regulators are AGA or UL144 approved.

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

Overview of Today s Program

Safety Manual Section 6 Confined Space

Scope: This plan applies to all personnel, including contractors, who enter or work in confined spaces, or supervise such activities.

SECTION 9 CONFINED SPACES

Safety Regulations and Procedures GENERAL SAFETY Confined Spaces - S New 11/96. To provide guidance for the safe entry of confined spaces.

INSTRUCTIONS FOR CONVERTING CONDENSING GAS MOBILE HOME FURNACES MODEL SERIES: CMA3*, CMC1*, VMA3*, VMC1*

Saskatchewan Health S A WHIRLPOOL DESIGN/OPERATIONAL T C H E W STANDARDS. Updated 02/00

Process for Identifying Confined Spaces

INSTALLATION GUIDE Gas Rangetops

SAFETY POLICY AND PROCEDURE MANUAL All Euramax Subsidiaries. Number B-6.0 Confined Spaces

The Duopex Gas. to make every job quick and easy. it provides a revolutionary alternative for the professional plumber and 02_DUOPEX GAS GAS MANUAL

Bulletin TCR-104 & 109 Filling and adding to the Glycol pressure system

THE CITADEL The Military College of South Carolina 171 Moultrie Street Charleston, SC MEMORANDUM 30 June 2017 NUMBER (X)-(Y) CONFINED SPACE

Clear up confusion between the requirements for confined spaces and grain storage structures.

American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

ACS.CoNGLP1 SAFETY ASSESSMENT CRITERIA INITIAL & RE-ASSESSMENT DOMESTIC NATURAL GAS TO LPG GENERIC

Quiz #1 Thermodynamics Spring, 2018 Closed Book, Open Appendices, Closed Notes, CLOSED CALCULATORS

Confined Space Program

American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM

APPENDIX 4 STANDARD FORMAT FOR THE PROCEDURES AND ARRANGEMENTS MANUAL

APPLICIPABLE STANDARD: OSHA 29 CFR Confined Space Entry

ACCESSORY KIT INSTALLATION INSTRUCTIONS

CONFINED SPACE PROGRAM

Eclipse Extern-A-Therm Recuperators

Key Technology, Inc. Confined Space Entry Program. July, 2017

Overview EUSSAM12. Carry out tightness testing and direct purging of gas installations

Crab and Lobster Live Holding System Part II (Water Pumps, Air Pumps and Pipework)

PSSI 36 General Confined Spaces, Tunnels, Culverts and Similar Spaces

CONFINED SPACE ENTRY

1.0 Scope and Application. 2.0 Definitions. Cal Poly Risk Management Confined Space Program Page 1

SIZING AND CAPACITIES OF GAS PIPING Reserved

WARNING: Gas Conversion Kit Instructions Applies to: Model UDAP, UDAS, UDBP, and UDBS Unit Heaters. General and Warnings FOR YOUR SAFETY

ACCESSORY KIT INSTALLATION INSTRUCTIONS

Confined Space Entry

North American Orifice Metering System

Installation Instructions

ESCONDIDO FIRE DEPT TRAINING MANUAL Section Truck Module Page 1 of 5 Utilities Gas Emergencies Revised

Confined Space Entry Program 8 CCR 5157

INSTALLATION & OPERATION MANUAL FOR Stockpot Range

Confined Space Entry Program

SIZING AND CAPACITIES OF GAS PIPING

CONFINED SPACE WRITTEN PROGRAM

Confined Space Program

GAS KITS & ACCESSORIES 504,986M 11/2004 HIGH ALTITUDE KIT

SIZING AND CAPACITIES OF GAS PIPING

PSD 250 Minimum Lubrication System. For lubricants in the 1000 mm²/sec viscosity range

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

Confined Space in Construction

Gas Furnaces 95AF2V. Warranty Heat Exchanger - 20 Year Limited Parts - 5 Year Limited

Confined Space Entry

Product Catalogue DAV - P DAV - P. Air release & Vacuum Break Valves. (Plastic Air Valves) DAV - P

INSTALLATION & OPERATION MANUAL FOR Teppan-Yaki Griddles

BGA158, BGA171 and BGA110 Series Shutoff Gas Valve

Reducing Exposures From Confined Space Entry

Safe work method statements

WEEKLY SAFETY MEETING

CAPITAL CONTROLS SERIES NXT3000

pressure regulator Zero pressure regulator Proportional pressure regulator Compressed air-controlled

CastCreations PRODUCT DESCRIPTION. Redwood Stump Fire Pit Item #: C1002. CastCreations Ph: Aurora, Utah

RISK ENGINEERING TECHNICAL GUIDE

Modulating Valves for Atmospheric, Infrared, and Direct Fired Burners

Transcription:

o. 9196 REGISTRATIO EXAMIATIO, JUE 2017 CERTIFYIG GASFITTER ASWER SCHEDULE Plumbers, Gasfitters and Drainlayers Board, 2017. All rights reserved. o part of this publication may be reproduced by any means without the prior permission of the Plumbers, Gasfitters and Drainlayers Board.

ASWER 1 (a) To provide ventilation. To prevent external moisture being accumulated or transferred. (2 marks) (b) (i) Fire resistance. Bracing. Sound proofing. Wet lining. (2 marks) (ii) Colour of the board. Labels/stamping/thickness. (2 marks) Total 6 Marks ASWER 2 (a) Any THREE (1 mark each) Position of power lines. Suitability of surrounding ground. Operator of the cherry picker is trained. Availability of a suitable harness. (3 marks) (b) Advise the owner or occupier. Advise the Secretary of Energy/Energy Safety Service. (2 marks) Total 5 Marks ASWER 3 Supply Pressure Length of Longest Run Quantity of 15 mm Appliance Regulators Quantity of 20 mm Appliance Regulators Quantity of 15 mm Flexible Hoses Quantity of 20 mm Flexible Hoses 2.42 kpa 6.5 m 7.5 m 3 (½ mark) 6 (½ mark) 1 (½ mark) 4 (½ mark) Pipe section MJ/h Diameter (mm) Pipe section MJ/h Diameter (mm) A - B 1135.5 (½ mark) 40 (½ mark) I - K 196 (½ mark) 20 (½ mark) B - C 210 (½ mark) 25 (½ mark) H - L 451.5 (½ mark) 32 (½ mark) C - D 60 (½ mark) 15 (½ mark) L - M 128 (½ mark) 20 (½ mark) C - E 150 (½ mark) 20 (½ mark) L - 323.5 (½ mark) 25 (½ mark) B - F 925.5 (½ mark) 40 (½ mark) - O 31.5 (½ mark) 10 (½ mark) F - G 150 (½ mark) 20 (½ mark) - P 292 (½ mark) 25 (½ mark) F - H 775.5 (½ mark) 32 (½ mark) P - R 96 (½ mark) 20 (½ mark) H - I 324 (½ mark) 25 (½ mark) P - Q 196 (½ mark) 20 (½ mark) I - J 128 (½ mark) 20 (½ mark) Total 21 Marks Certifying Gasfitter 9196 Answers, June 2017 1

ASWER 4 (3.142) 12.5 x 12.5 = 490.93 490.93 + 490.93 = 981.86 981.86 (3.142) = 312.49 Square root of 312.49 = 17.67 Radius = 17.67 mm. Diameter = 35.34 mm. Minimum diameter 40 mm. ASWER 5 Total 5 Marks Appliance Daily operating time Consumption (m 3 /day) atural gas, package burner 95 kw 8 hours 68.4 LPG, cooker 140 MJ/h 3 hours 4.6 atural gas, furnace 113,750 BTU 5 hours 15 atural gas, space heater 35 MJ/h 4 hours 3.5 Total 4 marks ASWER 6 (a) Figure (i) the same size as the vent outlet connection on the regulator. Figure (ii) one pipe size larger than the vent outlet connection on the regulator. (b) 1 Orifice To allow a greater flow for less differential pressure 2 Spring To provide greater resistance to valve movement (4 marks) Total 6 Marks ASWER 7 (a) (i) 26 000 BTU = 27.43 MJ Code references: 650, 610 From the code Area = (610 27.43) + (650 no. of occupants) = (610 27.43) + (650 4) = 19332.3 mm 2 (ii) Height = area/width = 19332.3/300 = 64.4 mm Certifying Gasfitter 9196 Answers, June 2017 2

(b) (i) Any TWO (1 mark each) Behind the appliance Vented to outside One above the absorption fins One at low level (2 marks) (ii) 32 500 mm 2 Total 8 Marks ASWER 8 180 litres of water has mass 180 kg Temp. diff. = 70-18 = 52ºC 45 MJ/h = 45 000 kj/h Heating time = mass of water 4.2 temp. diff. heat energy input per hour efficiency 100 = 180 x 4.2 x 52 x 100 45 000 x 78 = 1.12 hours = 67 minutes Total 6 Marks ASWER 9 (a) Flue Section Minimum Size A B C D E 125 mm 125 mm 100 mm 75 mm 75 mm (5 marks) (b) Any FOUR (½ mark each) Insulate flue. Protect flue from exposed area. Select shortest route to atmosphere. Avoid offsets/avoid lateral runs. Increase flow with greater dilution. Use appropriate material for the flue. (2 marks) Total 7 Marks Certifying Gasfitter 9196 Answers, June 2017 3

ASWER 10 (a) Any THREE (1 mark each) Is large enough for a worker to enter and perform assigned work. Has limited entries and exits. May contain a hazardous atmosphere, arising from chemicals, sludge or sewage. Is constructed so that anyone who enters could be asphyxiated or trapped by walls or floor that converge to a small cross-section, such as a hopper. Contains a material, such as sawdust or grain that could engulf anyone who enters. (3 marks) (b) Description of work otifiable Work Y/ Working in an area where the temperature exceeds 45ºC Working in a confined space Working on a scaffold which is over 5 metres high A trench which is 2 metres deep and 4 metres wide at the top Work on the roof of a 2 storey residential building which is 6 metres high. Work in which a person wears a face mask with filter canisters Using a 3.5 meter high mobile scaffold on a commercial site Working on a residential property which is known to contain asbestos containing materials Y (½ mark each, 4 marks) Total 9 Marks Certifying Gasfitter 9196 Answers, June 2017 4

ASWER 11 (a) Any SIX (1 mark each) That the work has been done lawfully and safely, and the information on the certificate is correct. That the work has been done in accordance with means of compliance in AS/ZS 5601 Part 1 or 2. Whether the work has been done in accordance with the certified design for the gas installation. Which other Standards were complied with (if this was required). Whether the work done relied on any manufacturer s instructions. The type of gas the installation is safe to connect to. The gas pressure that the installation is safe to connect to. Which parts of the installation, if any, are safe to connect to a gas supply. The location of the gas installation. Describe the work done and who did what, if different work was done by different people The name and registration number of the person issuing the certificate. The name and registration number of any other person who did any of the gasfitting work under supervision. The date(s) on which the work was done. Be signed and dated by the person issuing the certificate. Display the Authentication Mark. include a copy or reference to the manufacturer s instructions and certified design used for the work. This may be a reference to where the documents can be found by electronic means (e.g. a website). (6 marks) (b) Complete a Gas Safety Certificate (GSC). Instruct the owner. Lodge an entry into the high rise database. (2 marks) Total 9 Marks ASWER 12 (a) Operating pressure exceeds 7 kpa. The location of the pipe is not readily identifiable as consumer piping. (2 marks) (b) Spacings not more than 8 mm. (c) Where the operating pressure exceeds 7 kpa. (d) The piping must have a quarter turn, manual shut off vavle for each occupancy The valves must be accessable, and where practicable, external to the occupancy. A durable permanent sign must be located adjacent to each valve, with the wording GAS VALVE. (3 marks) Total 7 Marks Certifying Gasfitter 9196 Answers, June 2017 5

SECTIO B 1. E 2.0 m. 2. D 7.0 kpa. 3. C 20 mm per m. 4. D 450 mm. 5. B 6 mm. 6. C 440 C. 7. D 50 MJ/h. 8. A 20 litres/second. 9. E 6. 10. B 50 mm. Total 10 Marks