Appendix 10. Conceptual Measurement, Accounting and Reporting Plan

Similar documents
Micro Motion Coriolis Oil & Gas Metering Recommended Practices for Upstream Allocation

The ERCB Directive 017 Overview

Drilling Efficiency Utilizing Coriolis Flow Technology

FAQs about Directive 017

Ron Gibson, Senior Engineer Gary McCargar, Senior Engineer ONEOK Partners

Micro Motion 3098 Gas Specific Gravity Meter

Micro Motion 7812 Fiscal Gas Density Meter

Micro Motion Multiphase Applications

FAQs about Directive PNG017: Measurement Requirements for Oil and Gas Operations

2600T Series Pressure Transmitters Plugged Impulse Line Detection Diagnostic. Pressure Measurement Engineered solutions for all applications

T EK-COR 1100A. Coriolis Mass Flowmeter. FLOW. Technology Solutions

Coriolis Mass Flow Meter

A review of best practices for Selection, Installation, Operation and Maintenance of Gas meters for Flare Applications used for Managing facility

Vehicle-mounted meters, pump supplied

Micro Motion Advanced Phase Measurement

Using Modbus Protocol with the ALTUS Net Oil Computer. Instruction Manual

Vehicle- or rack-mounted liquefied gas meters, pump supplied

CoriolisMaster mass flowmeter Diagnostics, verification and proof test

PHIL JANOSI MSC. International Product Manager, Coriolis Flowmeter KROHNE Ltd, UK.

Installation Manual , Rev BB December Micro Motion H-Series Hygienic Coriolis Flow and Density Sensors

Truck-mounted Mass Flow Metering for LPG Delivery

For Multi-Parameter Meters see mvx

WATER TREATMENT SYSTEM OPERATION MANUAL

NEW VERSAFLOW CORIOLIS

Oil and Gas Custody Transfer

For Multi-Parameter Meters see mvx

New power in production logging

Measurement Requirements for Upstream Oil and Gas Operations

Installation Manual MMI , Rev AA April Micro Motion TA-Series Flow and Density Meters

Micro Motion Pressure Drop Testing

Improving distillation tower operation

SCOPE OF THIS GUIDE STARTING-UP. 1 Check mini CORI-FLOW functional properties

COMPAFLOW. Compressed Air. Volumetric flow. Gas. Mass flow. Steam. Net volumetric flow. Liquid

ONSITE PROVING OF GAS METERS. Daniel J. Rudroff WFMS Inc West Bellfort Sugar Land, Texas. Introduction

PROCESS MONITORING AND CONTROL

Cold-acclimatised pipelines

Level MEASUREMENT 1/2016

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

Fisher DVI Desuperheater Venturi Inline

RESILIENT SEATED BUTTERFLY VALVES FUNCTIONAL SAFETY MANUAL

Quick Installation Guide Doc nr.: C Date:

Design DSA Steam-Atomized Desuperheater

Truck Unloading Air Eliminators

Multiphase MixMeter. MixMeter specification. System Specification. Introduction

Manual of Petroleum Measurement Standards Chapter 6 Metering Assemblies Section 3A Pipeline and Marine

Point level switches for safety systems

Micro Motion H-Series Hygienic Coriolis Flow and Density Meters

Vortex flowmeters. Product family introduction Principle of operation Product review Applications Key product features

the asset can greatly increase the success rate of Coriolis technology in this application. 3 Coriolis measurement in multiphase flow

An Overview of a Market Research Study on the Worldwide Coriolis Flowmeter Market

EL-O-Matic E and P Series Pneumatic Actuator SIL Safety Manual

ENSURING AN ACCURATE RESULT IN AN ANALYTICAL INSTRUMENTATION SYSTEM PART 1: UNDERSTANDING AND MEASURING TIME DELAY

Measurement Requirements for Oil and Gas Operations

Instructions for SMV 3000 Multivariable Configuration (MC) Data Sheets

DPC-30 DPC-100. Reference Manual

ONSITE PROVING OF GAS TURBINE METERS Daniel J. Rudroff Invensys Metering Systems

Special Documentation Proline Promass 500 Coriolis Flowmeter Modbus RS485 Petroleum Application Package

Autocalibration Systems for In Situ Oxygen Analyzers

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

Integral type Differential pressure flowmeter VNT Series

AUTOMATIC HOSE TEST UNIT, TYPE SPU

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

This manual provides necessary requirements for meeting the IEC or IEC functional safety standards.

Positive displacement proportioning of two-component epoxy intumescent coatings for passive fire protection

The Discussion of this exercise covers the following points:

485 Annubar Primary Flow Element Installation Effects

Malema Sensors M-2700 Integrated Ultrasonic Flow Meter

T EK-COR 1100A Coriolis Mass Flowmeter

Calibrating and Monitoring MUSMs in Natural Gas Service

Specifications and information are subject to change without notice. Up-to-date address information is available on our website.

Differential Pressure Transmiter

Gas Measurement Fundamentals Certification. Curriculum

Safety manual for Fisher GX Control Valve and Actuator

Title: Standard Operating Procedure for R&R Environmental Devices Model MFC201 Gas Dilution Calibrator

UNDERSTANDING, ACCELERATED

HumiSys HF High Flow RH Generator

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

HEATEC TEC-NOTE. Setting Siemens Pressure Transmitter. Used on Heatec Vertical Asphalt Tanks. Publication No , Revised

Radar, Ultrasonic and RF Level Transmitters

Air Eliminators and Combination Air Eliminators Strainers

Field Testing of an Automated Well Tester in a Heavy Oil Application. Rafael Bastardo, Weatherford José Scoglio, Petrozuata Asher Imam,, Weatherford

Vortex Flow Meter Wafer or Flange Connection. - Steam - Liquid - Gas

NT High-temperature flowmeter model Simultaneous flow and pressure outputs for high-temperature applications

An innovative technology for Coriolis metering under entrained gas conditions

CCT-7320/ROC-2313 Reverse Osmosis Controller

ProSoft Technology, Inc. Summary Regarding Alberta Energy and Utilities Board Directive 017 of May 2007

InstrumentationTools.com

2007 Gas-Lift Workshop

Effect of noise in the performance of the transducers in an ultrasonic flow meter of natural gas

Installation Manual , Rev BC January Micro Motion R-Series Coriolis Flow Sensors

Impact of imperfect sealing on the flow measurement of natural gas by orifice plates

ACCURATE PRESSURE MEASUREMENT FOR STEAM TURBINE PERFORMANCE TESTING

Fisher DSA Steam-Atomized Desuperheater

JOSOP 603 flaring and venting Standard

Technical Data Sheet. OPTIMASS 7000 Custody Transfer Mass Flowmeter

ULTRASONIC METER FLOW CALIBRATIONS CONSIDERATIONS AND BENIFITS. Joel Clancy

44 (0) E:

SPE The paper gives a brief description and the experience gained with WRIPS applied to water injection wells. The main

L 100. Bubble-Tube Level System. Installation, Operation and Maintenance Instructions

Micro Motion 2-Wire Time Period Signal (TPS) Gas Density Meter (GDM)

Transcription:

Appendix 10 Conceptual Measurement, Accounting and Reporting Plan

GERMAIN EIA CONCEPTUAL MEASUREMENT, ACCOUNTING AND REPORTING PLAN NOVEMBER 2011

LARICINA ENERGY LTD. Appendix 10: Measurement, Accounting and Reporting Plan Germain Project Expansion TABLE OF CONTENTS 1 GENERAL INFORMATION...1 1.1 GENERAL SCHEME/PROCESS DESCRIPTION AND LOCATION...1 2 PROCESS AND MEASUREMENT DRAWING...3 3 DESCRIPTION OF PROPOSED OPERATING PROCEDURES...4 3.1 CALIBRATION AND PROVING...4 4 ACCOUNTING CALCULATIONS AND REPORTING...5 4.1 FACILITY PRA CONFIGURATION AND REPORTING...5 4.2 VOLUME REPORTING...5 4.3 VOLUME CALCULATIONS...5 4.4 FACILITY RECEIPTS & DISPOSITIONS...5 4.5 WELL PRODUCTION PRORATION...6 5 APPENDICES...7 LIST OF APPENDICES Appendix A Appendix B Conceptual Measurement Drawings Entrained Gas Handling in Micro Motion Coriolis Flowmeters November 2011 Page -i

LARICINA ENERGY LTD. Appendix 10: Measurement, Accounting and Reporting Plan Germain Project Expansion 1 General Information Laricina Energy Ltd. Germain Project Expansion EIA AEPEA Approval TBD ERCB Approval TBD Correspondence respecting this MARP should be directed to: Ms. Deepa Thomas Laricina Energy Ltd. 4100, 150-6 th Ave SW Calgary, Alberta T2P 3Y7 Phone: (403) 718-8810 Fax: (403) 263-0767 E-Mail: Deepa.Thomas@laricinaenergy.com 1.1 General Scheme/Process Description and Location Laricina Energy Ltd. (Laricina) plans to expand the Oil Sands Conservation Act (OSCA) approved Germain Commercial Demonstration (Phase 1) Project with the proposed Germain Project Expansion (the Project) which will integrate the Phase 1 project with the three additional phases of development Phase 2, Phase 3 and Phase 4. The Phase 1 project is a thermal solvent in-situ oil sands facility with ten Solvent Cyclic-Steam Assisted Gravity Drainage (SC-SAGD) well pairs producing up to a design rate of 4,770 m 3 /day (5,000 bbl/d). The Central Processing Facility (CPF) of Germain Phase 1 Project is located 50 km northeast of the community of Wabasca-Desmarais in Sections 3 and 4, Township 85, Range 22 W4M. The Phase 1 project has received regulatory approval under AEPEA Approval 242701-00-01 and ERCB Approval 11509B. The proposed Project Expansion will be located east of the Phase 1 project. Laricina plans to utilize either SC-SAGD or SAGD technology in Phase 2 of the Project. This application presents two facility designs to facilitate flexibility for steam requirements. The first facility design is based on SC-SAGD with a steam-oil ratio (SOR) of 2.2 (SC-SAGD-2.2) and the second facility design is based on adding steam capacity to allow for operations based on an SOR of 3.3 (SC-SAGD-3.3) should Laricina choose to employ SAGD technology. Phase 2 of the Project will incorporate the addition of 60 well pairs on six pads for SAGD with a steam-oil ratio (SOR) of 3.3 operations or 38 well pairs on four pads for SC-SAGD (SOR 2.2) operations, and additional process facilities for steam generation and injection, solvent injection November 2011 Page -1

LARICINA ENERGY LTD. Appendix 10: Measurement, Accounting and Reporting Plan Germain Project Expansion and recovery, water treatment, production handling, waste disposal and dilbit exporting (via pipeline / Lease Automatic Custody Transfer (LACT) and truck loading). This expansion will increase the total capacity of the Project to approximately 16,900 m 3 /d Cold Water Equivalent (CWE) dry steam, up to 1,000 m 3 /d of diluent and up to 550 m 3 /d of propane for 5,120 m 3 /d bitumen production based on the more conservative installed SOR of 3.3. Phase 3 of the Project will incorporate the addition of 100 SC-SAGD well pairs on nine well pads, and additional process facilities for steam generation and injection, solvent injection and recovery, water treatment, production handling, waste disposal and dilbit exporting (via pipeline / LACT and truck loading). This expansion will increase the total capacity of the Project to approximately 44,450 m 3 /d CWE dry steam, up to 3,800 m 3 /d of diluent/pentane and up to 1,400 m 3 /d of propane for 16,550 m 3 /d bitumen production. Phase 4 of the Project will incorporate the addition of 100 SC-SAGD well pairs on five double well pads, and additional process facilities for steam generation and injection, solvent injection and recovery, water treatment, production handling, waste disposal and dilbit exporting (via pipeline / LACT and truck loading). This expansion will increase the total capacity of the Project to approximately 73,250 m 3 /d CWE dry steam, up to 6,200 m 3 /d of diluent/pentane and up to 1,400 m 3 /d of propane for 26,750 m 3 /d bitumen production. November 2011 Page -2

LARICINA ENERGY LTD. Appendix 10: Measurement, Accounting and Reporting Plan Germain Project Expansion 2 Process and Measurement Drawing Appendix A contains the Process and Measurement Drawings for each phase of the expansion. For Phase 2, the drawings reflect the SC-SAGD-3.3 case, as it is the more conservative of the two facilities. Drawing series GER-X1-44-SCH-0001-01 shows the oil and gas streams and drawing series GER-X1-44-SCH-0001-01 shows the water streams. The emulsion streams are shown on both drawings. The following is an index of all drawings included in Appendix A: Drawing Number GER-21-44-SCH-0001-01 GER-21-44-SCH-0001-02 GER-31-44-SCH-0001-01 GER-31-44-SCH-0001-02 GER-41-44-SCH-0001-01 GER-41-44-SCH-0001-02 GER-51-44-SCH-0001-01 GER-51-44-SCH-0001-02 Detail Germain Commercial Demonstration Phase 1 - Oil and Gas Germain Commercial Demonstration Phase 1 - Water Germain Project Expansion Phase 2 - Oil and Gas Germain Project Expansion Phase 2 - Water Germain Project Expansion Phase 3 - Oil and Gas Germain Project Expansion Phase 3 - Water Germain Project Expansion Phase 4 - Oil and Gas Germain Project Expansion Phase 4 - Water Note that these drawings are based on presently known information and subject to change. November 2011 Page -3

LARICINA ENERGY LTD. Appendix 10: Measurement, Accounting and Reporting Plan Germain Project Expansion 3 Description of Proposed Operating Procedures 3.1 Calibration and Proving Laricina s overall metering objective is to ensure that it has properly installed, commissioned, and configured the flow and level meters required to accurately determine the volumes of all products entering and leaving the facility. Laricina will install additional metering which will balance groups of meters against each other, thereby verifying their accuracy online. Accuracy balances will be calculated on an hourly and daily basis. Errors outside of normal operating limits will be reported to operations and maintenance. Calibrations and calibration history, where possible, will be performed with the assistance of an online Asset Management System (AMS). The majority of the instrumentation is expected to communicate to the AMS (via HART protocol), which when used as part of the calibration procedure, will simplify and improve overall accuracy of calibration results and record keeping. This database will be available for regulatory inspection at any time, and records will be maintained and backed up for a minimum of 6 years. In order to reduce visual inspection requirements, Laricina has made an effort to select smart meters that the ERCB will recognize as having built-in diagnostics to continuously monitor the condition of the primary element in accordance with Directive 017, Section 2.6. The intent of this is to reduce or eliminate the requirement for visual inspections for meters such as coriolis, magnetic, and ultrasonic. It is expected vortex meters will be removed from service and visually inspected tri-annually (every three years). On-board diagnostics on smart meters will be used between inspections to monitor the flow element health. If at any time the meter diagnostics indicate a flow element issue, the meter will be removed from service and inspected. All required calibrations will be performed according to the manufacture s recommendations and will meet the requirements of the ERCB Directive 017 Measurement Requirements for Upstream Oil and Gas Operations. Laricina will also install the required primary and secondary metering as required in ERCB Directive 017, section 12.4.6. November 2011 Page -4

LARICINA ENERGY LTD. Appendix 10: Measurement, Accounting and Reporting Plan Germain Project Expansion 4 Accounting Calculations and Reporting 4.1 Facility PRA Configuration and Reporting The facility will be reported to the Petroleum Registry as a Type 344 In Situ Oil Sands Battery and a Type 506 In Situ Oil Sand Injection / Disposal Facility, as well as the associated production, injection, source water and water disposal wells. Facility delineation is indicated on the conceptual measurement schematics in Appendix A. Each phase of the Project will be an expansion of the existing reporting facilities, and will not be reported as separate facilities. 4.2 Volume Reporting All volumes will be reported in metric units at standard temperature and pressure (STP) of 101.325 kpa absolute and 15.0 C. The following units will be used for volumetric reporting: Gas..Se 3 m 3 Liquid..Sm 3 Steam...Sm 3 c.w.e. (cold water equivalent) 4.3 Volume Calculations All volumes reported to the petroleum registry will be calculated and corrected for deviation from standard temperature and pressure using industry standard volume calculation and compensation algorithms. Due to the high operating temperatures found in an in situ bitumen recovery scheme, all metered volumes will be compensated for operating temperature to facilitate volume balancing and troubleshooting. 4.4 Facility Receipts & Dispositions The battery will regularly receive shipments of diluent for use in the bitumen treating process. Primarily diluent will be trucked into the facility, with future plans to install a diluent pipeline to the facility. November 2011 Page -5

LARICINA ENERGY LTD. Appendix 10: Measurement, Accounting and Reporting Plan Germain Project Expansion A truck unloading station, complete with volume and density will be installed to unload diluent from the trucks. When the future pipeline is completed, diluent receipts will be metered at the LACT meter station. The battery will also receive propane shipment for use as injection solvent during the solvent injection production phases. Propane receipts will be reported via truck tickets and reconciled against solvent inlet metering and change in inventory. Battery bitumen production will be primarily transported via pipeline. All dispositions to the pipeline will be measured via a LACT meter station installed at the battery outlet. A small fraction of bitumen production will be transported via truck. A truck loading station, complete with volume and density will be installed to load bitumen on to the trucks. All truck loading data will be reconciled monthly against receipt point truck tickets. 4.5 Well Production Proration Total battery bitumen production and water production will be prorated to the production wells based on regular well test results. Laricina will be using coriolis meters at each wellhead. Laricina will operate the producer wellhead at a pressure slightly higher than the bottom hole pressure to mitigate the potential measure problems with entrained gas. A white paper Entrained Gas Handling in Micro Motion Coriolis Flowmeters, explaining how accurate emulsion flow rates will be achieved is attached as Appendix B. It should be noted that if entrained gas does create problems, Laricina will be manually entering a density of the emulsion into the coriolis meter based on lab test data. This will allow the meter to give an emulsion flow reading unaffected by entrained gas. The online density reading from the coriolis meter will be representative of the entrained gas. A test separator is not provided but provisions for a future test header with a water-cut meter are included in the design. Total battery gas production will be measured using the produced gas meters and a chromatograph compositional analysis. The total battery produced gas will be allocated to the production wells based on their individual prorated oil production, resulting in a gas proration factor of 1.000. November 2011 Page -6

LARICINA ENERGY LTD. Appendix 10: Measurement, Accounting and Reporting Plan Germain Project Expansion 5 Appendices November 2011 Page -7

LARICINA ENERGY LTD. Appendix 10: Measurement, Accounting and Reporting Plan Germain Project Expansion Appendix A Conceptual Measurement Drawings November 2011

LARICINA ENERGY LTD. Appendix 10: Measurement, Accounting and Reporting Plan Germain Project Expansion Appendix B Entrained Gas Handling in Micro Motion Coriolis Flowmeters November 2011

MICRO MOTION WHITE PAPER BY TIM PATTEN, MICRO MOTION, INC. Entrained Gas Handling in Micro Motion Coriolis Flowmeters KNOWLEDGE WWW.micromotion.com Introduction This white paper discusses the measurement problems caused by process fluids that contain bubbles of air or other gas, and describes how Micro Motion sensor and transmitter technology can be used to overcome those problems. This white paper also presents suggestions for minimizing measurement problems by improving application design. Although the most common term applied to this problem is entrained air, in fact the bubbles may contain any gas. This white paper uses the term entrained gas rather than entrained air in order to address the broader topic. Other frequently used terms include two-phase flow and slug flow. Historical perspective Micro Motion products were originally developed for the chemical industry, where most applications contain very little entrained gas, and Micro Motion's product vision focused on high measurement accuracy in clean fluids. As Coriolis technology has moved into other applications and other industries, the issue of entrained gas has become more significant. While, in fact, more than 95% of applications do not have a problem with entrained gas, entrained gas handling is critical for those few applications that do. The entrained gas problem Micro Motion's Coriolis sensor technology produces direct measurements of mass, density, and temperature. When gas is present in a liquid stream, it occupies volume. It is important to understand that entrained gas does not cause primary measurement errors in mass flow measurement: Coriolis technology measures any fluid mixture in the tubes. However, because the density measurement is a ratio of mass to volume, if some of the volume is occupied by gas, which is less dense than liquid, then the overall density of the mixture must decrease. Because most applications need to know the density of the liquid only (the liquid fraction) rather than the density of the mixture, the density value reported by the meter will not be incorrect, but will be low for application purposes. Until Coriolis meters can reach beyond measuring just what is in the tubes and distinguish fluid phases, this deviation will not be correctable. 1 Micro Motion technology Existing Micro Motion technology can be used with good results in applications that contain entrained gas, if the correct products are used and configured appropriately. In addition, certain application characteristics can improve measurement. These application characteristics are discussed in the section entitled Application recommendations. Sensor technology For two-phase flow, the best measurement is provided by dual-tube sensors with a low tube frequency. If a sensor with high tube frequency is used, the two-phase fluid does not vibrate with the tube, resulting in large measurement errors for flow. Micro Motion's ELITE sensors are recommended for applications with entrained gas. F-Series and R-Series sensors meet application requirements in certain situations. Because the single-tube T-Series sensors have a high operating frequency, they are not recommended for applications with entrained gas. Transmitter technology In general, analog signal processing, as used by Micro Motion's RFT9739 and earlier transmitters, is not flexible enough to measure two-phase flow. There is no way to change or optimize the signal processing chain for a specific application. 1. Because Coriolis meters use density data to calculate volumetric flow, the density deviation will cause a proportional error in the volumetric flow indication. WP-00920 / 2006 Micro Motion, Inc. All rights reserved.

MICRO MOTION WHITE PAPER Page 2 of 4 Micro Motion's MVD technology employs digital signal processing (DSP). This allows the transmitter software to apply algorithms to the raw sensor data to compensate for specific conditions. In the case of entrained gas, the transmitter must remove or look through the noise imposed by the two-phase flow, and report only the real flow measurement of the liquid. The DSP algorithms in the MVD electronics very effectively filter the noise and provide an excellent measurement. Transmitter configuration For two-phase flow, two transmitter configuration parameters are central: Special mode is used to increase the rate at which sensor data is reported to the transmitter. This allows the transmitter to filter, process, and report compensated density data almost instantaneously. Fault action is used to control the behavior of transmitter outputs under certain process conditions such as two-phase flow. The factory default setting for fault action is to drive outputs to fault levels, which means that they no longer report process data. When fault action is set to none, outputs continue to report process data during two-phase flow conditions. In current Micro Motion products, these parameters are set by activating the Entrained Gas option. In the next generation of Micro Motion products, special mode will be activated automatically and alarm handling has been changed to allow user configuration of fault severity levels. When two-phase flow alarms are set to a lower severity level, outputs will report process data during conditions of two-phase flow, but will still report all alarms configured for higher severity levels. The transmitter can optionally log the two-phase flow alarms. Transmitter zero Unstable fluid conditions (e.g., air separation from the liquid at low or zero flow) can cause significant measurement errors. For this reason, performing an autozero under unstable fluid conditions is highly discouraged. If the field zero is suspect, return the meter to the factory zero or the prior zero. Depending on your product, either or both of these is saved in transmitter memory. Application recommendations The most important application factor in improving twophase flow measurement is bubble distribution. For best measurement results, the gas bubbles in the process fluid should be distributed as evenly as possible between the two sensor tubes, and should move through the tubes at the same rate that they entered the tubes. The following factors contribute to even bubble distribution: Straight pipe runs. The swirl imposed by elbows in the piping can cause gas to enter the sensor tubes unevenly, causing measurement errors. Higher flow rates. If flow rate is sufficiently high, bubbles move through the sensor tubes at approximately the same rate at which they entered the tubes, counteracting the effects of bubble buoyancy (produced by gravity) and low-viscosity fluids as discussed below. When it is known that entrained air is present, Micro Motion recommends a flow rate no lower than 1/5 (one fifth) of full scale. Vertical pipe runs with upward flow. Especially at lower flow rates, bubble buoyancy tends to result in bubble collection at high spots in the sensor tubes (see Figure 1a). In Figure 1b, bubble buoyancy works with the flow to move bubbles through the tubes. Viscosity. High-viscosity fluids tend to hold the bubbles in suspension better than low-viscosity fluids, maintaining their original position and distribution and therefore moving them through the sensor with the liquid. Also, in high-viscosity fluids bubbles are more likely to stay dispersed, while in low-viscosity fluids small bubbles may coalesce into large bubbles that are more likely to collect. Figure 1a Figure 1b Figure 1. Effects of sensor orientation on bubble distribution A mixer can be used to help distribute bubbles. If a mixer is used, it should not swirl the flow. To address the boundary problems of Empty-Full-Empty batching, batch duration and meter fill time can be checked. In laboratory testing, batches with a duration of one minute or longer tended to be immune to the transient errors caused by gas remaining in the sensor tubes. As shown in Figure 2, repeatability improves as batch duration increases. Field experience has demonstrated that if the meter fill time is less than 0.1 seconds and the batch time is greater than 2-3 seconds, good Empty-Full-Empty batching

Entrained Gas Handling in Micro Motion Coriolis Flowmeters Page 3 of 4 performance can be expected with mass repeatability well below 0.1%. Meter fill time is a function of meter size and flow rate. 0.3 Mass Repeatability, (1sigma), % 0.25 0.2 0.15 0.1 Data collected under laboratory conditions. Please consult the factory for specific application situations. 0.05 0 0 5 10 15 20 25 30 35 40 45 Batch Time, seconds Summary Figure 2. Effects of batch duration on repeatability With appropriate product selection, installation, and configuration, Micro Motion's dual-tube Coriolis sensors paired with MVD technology minimize or overcome the measurement problems caused by entrained gas. As a result, the benefits of Micro Motion's Coriolis technology are available to an expanded set of applications in a broader range of industries, providing highly accurate measurement of mass flow, density, and volume flow with a single low-maintenance low-installed-cost device. About the author Tim Patten has been with Micro Motion, Inc. since 1989, in various engineering and marketing roles. He holds an M.S. in Mechanical Engineering from Worcester Polytechnic Institute in Massachusetts. He is currently the Measurement Director.

MICRO MOTION WHITE PAPER Page 4 of 4 Entrained Gas Handling in Micro Motion Coriolis Flowmeters WWW.micromotion.com Micro Motion supports PlantWeb field-based architecture, a scalable way to use open and interoperable devices and systems to build process solutions of the future. ELITE, ProLink, and the Micro Motion logo are registered trademarks, and MVD and MVD Direct Connect are trademarks of Micro Motion, Inc., Boulder, Colorado. The Emerson logo is a trademark of Emerson Electric Co. All other trademarks are property of their respective owners. Micro Motion supplies this publication for informational purposes only. While every effort has been made to ensure accuracy, this publication is not intended to make performance claims or process recommendations. Micro Motion does not warrant, guarantee, or assume any legal liability for the accuracy, completeness, timeliness, reliability, or usefulness of any information, product, or process described herein. For actual product information and recommendations, please contact your local Micro Motion representative. Micro Motion, Inc. USA Worldwide Headquarters 7070 Winchester Circle Boulder, CO 80301 T (303) 527-5200 (800) 522-6277 F (303) 530-8459 Micro Motion Europe Emerson Process Management Wiltonstraat 30 3905 KW Veenendaal T +31 0 318 495 670 F +31 0 318 495 689 Micro Motion Japan Emerson Process Management Shinagawa NF Bldg. 5F 1-2-5, Higashi Shinagawa Shinagawa-ku Tokyo 140-0002 Japan T +81 3 5769-6803 F +81 3 5769-6843 Micro Motion Asia Emerson Process Management 1 Pandan Crescent Singapore 128461 T +65 6 777-8211 F +81 6 770-8003

CHEMICAL Micro Motion Enhanced ELITE Meters Eliminate System Faults Caused by Entrained Air BENEFITS Reduced operation and maintenance costs by $100,000 in 10 months Improved safety and efficiency of the control system operation Allowed operators more time to focus on other demanding tasks PROCESS In 2004, a large-scale chemical manufacturer in China installed and commissioned 107 Micro Motion ELITE and R-Series Coriolis mass flow meters in their production process for two of their main products, 160KT Acrylic Acid (AA) and 70KT Acrylic Ester (AE). A majority of the flow meters were used in the process control applications, while the remaining meters were installed in the custody transfer applications. CHALLENGE In August 2006, the chemical manufacturer discovered that a number of the meters used in process control were producing abnormal results. The process variable outputs were showing sudden disruptions either up or down causing an alarm in the DCS system. The process control valve responded to this alarm with an automatic shut down of the system. After some troubleshooting to recover the system, the operators realized they had to switch from automatic operation to manual operation of the production process to determine what was causing the alarm. After monitoring the operation for a period of days, the operators found that the disruptions were caused by the presence of entrained air or bubbles in the process fluid. In most cases, the problem installations were associated with R-Series Coriolis flow meters being mounted close to a control valve. SOLUTION The chemical manufacturer contacted Micro Motion Field Service support to address the issue. After working with the customer s operation team at the site, the Field Service technicians verified the Table 1: Faults Readings for Meter Sample with EG Mode Before EG Mode After EG Mode Meter Faults in 20 days Faults in 26 days 1 0 Avg Faults/ day 2 6 2 3 8 0 4 3 11 5 23 4 18 6 5 0 7 19 1 8 9 2 9 0 0 10 7 0 Total 80 34 0 Avg Faults/ day 1.308 For more information: www.emersonprocess.com/solutions/chemical www.micromotion.com AN-001077 / 2008 Micro Motion, Inc. All rights reserved.

CHEMICAL meter error reading in the R-Series meters was caused by air entrainment. They found that during normal operation the actuation of the control valve caused air bubbles and slugs to be introduced into the process fluid. These upset conditions caused the disruptions in the meter readings from the Micro Motion meters. To address this issue, Micro Motion upgraded the problem meters with the latest configuration of electronics for the meters. This configuration change required that the new software feature, Entrained Gas mode (EG mode), be enabled. Once the customer implemented the configuration change, the amount of fault conditions decreased by 67% (see Table 1 on page 1). The remaining faults were caused by extended periods of slug flow or air bubbles that overwhelmed the compensation capabilities of the EG mode. For the meters still experiencing faults, Micro Motion suggested an upgrade to a new Enhanced ELITE sensor and electronics that incorporates a second-generation digital signal processor with built-in entrained gas capabilities. In August 2007, the chemical manufacturer upgraded two of its problem flow meters with the new Enhanced ELITE sensor and electronics technology. After several weeks of operation, the customer realized a complete elimination of errors at these two meters. With these results (see graph below), the customer chose to upgrade the remaining problem installations to the second-generation Micro Motion Coriolis meters. Since the replacement, the manufacturer s system is operating more safely and efficiently. Also, the system operators have had more time to work on other demanding tasks as the lines are essentially never down. With the cost of Acrylic Acid being more than $1500 per ton and the average system down time of 12 hours per month, the chemical manufacturer estimates a savings of at least $100,000 in 10 months of reduced operation and maintenance costs. Date at which the new Enhanced ELITE meters were installed in the process line Results of meter handling of entrained gas in the process line. After the installation of the ELITE meters, the meter readings showed a complete elimination of the sudden disruptions in the flow.