Ventam 85 Installation & Commissioning Instructions

Similar documents
SCIENCE LAB UTILITY CONTROLS

Gas Check. Short testing time, with automatic start-up if no leakage was detected from previous operation.

ECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

AUTOMATIC GAS MANIFOLDS

VERTICAL AIR COMPRESSORS

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units Digital Range

1. PARTS INTRODUCTION ELECTRICAL NOTES INSTALLATION 5/6. 5. START UP 6/7. 6. MAINTENANCE 7/8/9. 7. PRESSURE SWITCH ADJUSTMENTS 9/10.

Spirax Compact FREME Flash Recovery Energy Management Equipment

Stand-Alone Bubble Detection System

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

VERTICAL AIR COMPRESSORS

System Pressure Manager Standard & System Pressure Manager Plus

IP65 Air Differential Pressure Switch

PROVENGAS AUTOMATIC PROVING SYSTEMS FOR GAS INSTALLATION

Air Differentail Pressure Switch

Vertex VP Operation and Maintenance

Operator: Save these instructions for future use!

100L AIR COMPRESSOR MODEL NO: TIGER 16/1010 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS01/13

BUBBLER CONTROL SYSTEM

Operator: Save these instructions for future use!

Electro Controls. Pressure WattsIndustries.co.uk

Installation, operating and maintenance Instructions for Seemag bypass level indicator

EDUCATION DEPARTMENT ACCU-TEST

QPL... Pressure Switches. Siemens Building Technologies HVAC Products

ServicePlus S21R & S27R Series 2 Installation Instructions

Concentrate Distribution System (Stand Mounted) A-CDS-70-X & A-CDS-TANK-X-ST Industrial Drive, Orlinda, TN 37141

INSTALLATION GUIDE Gas Rangetops

24L AIR COMPRESSOR MODEL NO: TIGER 11/250 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS01/13

24L OIL FREE AIR COMPRESSOR MODEL NO: TIGER 7/250 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS10/13

NGP-250/500 Nitrogen Generator Quick Start Guide

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

Operator: Save these instructions for future use!

KMW3000C. User Manual. Water Chiller for Xcalibur and Gemini systems. Version 1.6, September 2010

INSTALLATION & OPERATING INSTRUCTIONS FOR THE DS300 BRAZING HEARTH FLAMEFAST (UK) LIMITED

AIR COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: CHAMP 3 PART NO: LS0115

24L AIR COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: RANGER 7/240 PART NO: LS0913

ACV-10 Automatic Control Valve

WIND CLIPPER KTS ILLUM SCALE INC DEC CLIPPER WIND SYSTEM

Universal Valve Company Inc

In Vessel Composter Installation & Commissioning Manual

Model PDT Dewpoint Transmitter

Operator: Save these instructions for future use!

Propane Conversion Kit Instruction

USER MANUAL. JET TST and JET TST S.

Model 130M Pneumatic Controller

Operator: Save these instructions for future use!

INSTRUCTION MANUAL. FLOW CONTROL DRAWERS MANUAL / PLC CONTROL SERIES Model Version Perma Pure LLC Tel:

Automatic Valve Proving Control

Table of Contents. Sensor Calibration and Troubleshooting CDS4000 CO 2. Introduction 1. Handling Information. Calibration 2.

AutoChanger Installation & User Guide Issue 2

Pressure Automated Calibration Equipment

TABLE OF CONTENTS TECHNICAL DOCUMENTATION 03

BUBBLER CONTROL SYSTEM

200L BELT DRIVEN AIR COMPRESSOR

Operator: Save these instructions for future use!

Operator: Save these instructions for future use!

Instructions for Use

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

AIR COMPRESSOR MANUAL INSTALLATION, OPERATION AND MAINTENANCE GUIDE

Columbus Instruments

24L AIR COMPRESSOR MODEL NO: TIGER 8/260 PART NO:

36E03 and 36E38 DSI and HSI Step Opening Combination Gas Valve INSTALLATION INSTRUCTIONS

Universal Valve Company Inc

RPS900W Redundant Power Supply. Installation Guide.

SAPCON. User Manual. Capacitance Continuous Level Indicator. . Introduction. . General Description. . Principle of Operation. .

Crest Heating Boilers FBN(L) Series &

UK RBF Bath buddy instruction 16pp 21/9/07 09:07 Page 1. Bath-Buddy / Bathmate Instruction Book

MANUAL GAS MANIFOLDS

USE AND ASSEMBLY INSTRUCTIONS

Budget Range Operators Handbook

50L BELT DRIVEN AIR COMPRESSOR

Mainsboost Charger Installation, Operation & Maintenance Instructions

36H SERIES Combination Gas Valve

Method Statement: Testing Dry Riser System

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

Duplex Commercial Softeners

36C/36D HSI, DSI Proven Pilot Gas Valves INSTALLATION INSTRUCTIONS

Deluge Optimo Shower valve and kit 10032CP

Installation Instructions / Operating & Maintenance Manual Midi-Fill Digital Pressurisation Unit Models MFD15 & MFD22

GM Series Dual-Block Multi-Function Gas Control Valves

Commercial Softeners. Installation, Operation & Maintenance Guide. Manual 002.1

COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: WARRIOR 55 PART NO: (110V) , (230V) , LS0512

TANK MANAGER FOR TWO TANKS OPERATING MANUAL. 10/31/11 C-More T6C L color touch panel

k valve 2 (50)HF 2½ (65)SF installation guide aylesbury For valve sizes (DN): tel fax

GATE 2 Part No

Miniature controls. Contactors. Overload relays. Starters. Control relays

Installation, use and maintenance instructions. Gas burner (5)

Code AWC20HP Air Compressor

Your safety and the safety of others are very important.

Installation, Operation & Maintenance Instructions

JET Mini Mechanical Pressurisation Equipment

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

TANDEM MODULATOR FOR OUTLET GAS FLOW: STEPPED (836 TANDEM) - CONTINUOUS (837 TANDEM) SERVO-CONTROLLED PRESSURE REGULATOR

PROPORTIONING VALVE. Model 150 INSTRUCTION MANUAL. March 2017 IMS Company Stafford Road

Propane Conversion Kit Instruction

Air Bubbler Depth Gauge DG2200 Installation and Reference Manual

INSTRUCTION MANUAL FOR MODEL 7360V VERTICAL CURING CHAMBER Revision E May

Electronic Single and Twin Pump System Pressure Managers

Transcription:

Ventam Systems Ltd Unit D4 Seedbed Business Centre Vanguard Way Shoeburyness Essex SS3 9QY Phone 01702 382 307 Fax 01702 382 340 Ventam 85 Installation & Commissioning Instructions 1 General The Ventam 85 is a combined Gas Proving and Ventilation Interlock Panel, to enable compliance with BS 6173. Current Electrical and Gas Regulations must be adhered to at all times and all Gas Proving & Interlock Systems must only be installed and/or maintained by competent and approved persons. Attention is drawn in particular to Regulations relating to isolation and de-isolation of Gas and Electrical Systems. All these instructions should be read before installation. Refer to wiring diagrams provided as required. 2 Principle of operation The Ventam 85 Interlock & Gas Proving System is comprised of three units: A Ventam 85 Control Panel. B Fan Air Flow pressure switch(es). C Gas Isolation and weep by-pass valve assembly. The Ventam 85 Panel is mounted in the kitchen where it is accessible and visible to the user. The Ventam 85 System prevents the gas proving system being operated UNTIL the fans are operating. Only then can Gas Proving commence. IF there are gas leaks or if valves have been left open at the appliances the main gas valve WILL NOT OPEN. Once the main gas isolation valve has opened, if the gas pressure subsequently falls below a pre-set level (60% of line pressure) or a fan is turned off, the main gas valve will close. Each time a fan is turned off OR an emergency stop is depressed OR the line gas pressure falls too low the system MUST BE GAS PROVED AGAIN. 3 Ventam 85 Interlock Panel Location Install the Ventam 85 Interlock Panel adjacent to the emergency exit and at an elevation suitable for the users to reach the panel controls. The panel must not be located where access to it may be obstructed e.g. by placing it behind an opening door or where it may be obstructed by mobile trolleys, hanging clothing or similar. It should not be located where the shut-off button could be operated accidentally. Mount the panel on a flat level surface. The Interlock panel must not be located adjacent to or above sources of heat, vapour or steam, e.g. beside or above a cooking range or cooking or washing appliances. The panel location must allow 600mm clearance to the front and 150mm clearance on all sides for access and maintenance. 4 Panel power Supply The panel must be supplied by a 240Vac five Amp single-phase earthed supply, via a fused spur or suitable isolator. Page 1 of 8

5 Additional Emergency Stop Buttons Where there is more than one emergency exit, a normally closed emergency stop button should be located at each exit. Additional emergency stop buttons are wired in series to terminals 11 and 12. This is a 12VDC circuit. 6 Gas Isolation Valve The Gas Isolation Valve must only be powered from the Ventam 85 Interlock Panel, as per supplied wiring diagrams and in accordance with Electrical and Gas Regulations. The main gas valve is rated at 240 VAC. The main gas valve must be fitted in an accessible location for future maintenance. The main Gas Isolation Valve must be fitted in the kitchen equipment gas supply pipe work. The valve is connected to the Ventam 85 Control Panel via three off THREE core cables. (These are all Live, Neutral and Earth). The gas isolation valve is heavy. Ensure that the gas pipe-work it is adequately supported. 7 Fan Pressure switch(es). The Fan Pressure switch is mounted adjacent to and above the Fan. The Fan Pressure switch is connected to the Panel by a two-core cable (12VDC). The Fan Pressure switch is connected to the Fan ductwork by a flexible tube which is supplied with the switch. The Fan Pressure switch senses the airflow and sends a Fans On signal to the Control Panel. The Fan pressure switch unit must be mounted vertically with tube connections at the bottom or the side and usually within one metre of the fan and in a dry, accessible location. The pressure switch should be located immediately above the fan. Where this is not possible, the pressure switch must be mounted as high as practicable to allow the pressure switch tubing to slope down from the pressure switch unit to the ductwork connector. Pressure switch tubing must slope down continuously from the pressure switch to the ductwork to allow condensate to naturally drain from the pipe work to prevent blockages occurring. Twists, loops and kinks are not permitted in the pressure switch tubing. The pressure switch unit location must allow 600mm clearance to the front and 150mm below for access and maintenance. DO NOT mount the pressure switch on the ductwork or transmitted vibrations may cause unreliability and reduce the operating life of the unit. 8 Fan Pressure switch location Consider the best location for mounting the unit AND for connecting the pipes from the pressure switch to the ductwork Mount the pressure switch(es). unit following above guide-lines. The suction side of the fan is at a negative pressure. Connect this side to the ve pressure connection on the pressure switch. The switch will detect a differential pressure between the ductwork negative pressure and the atmospheric pressure. This differential pressure will close the switch. At the pressure switch, the tube is connected to the push-fit connector on the bottom of the pressure switch. This connector is identified with a At the ductwork, the tube is connected onto the push-fit ductwork connector supplied with the pressure switch. Cut the tubing to the required length. The pressure switch connection should be as close as possible to the fan. Use a digital pressure meter in the range of 0-2mbar to check the system pressure while the fan is running at full speed and rotate the duct connector whilst measuring the recorded negative pressure. The arrow direction on the duct connector should oppose the airflow direction when fitted to the duct. This normally provides the best pressure reading possible. Pressure switch tubing must be protected and secured to prevent damage. Page 2 of 8

The pressure switch and pipe work must be replaced at 24-month intervals. Blocked or dirty filters will adversely affect airflow and pressure switch operation. When the ductwork is cleaned, the pressure switch tubing must be disconnected first to prevent contamination of the pressure switch and tube blockages affecting operation. 9 Panel interface terminals Terminals 5,6 and 7 are volt-free change-over contacts that mimic the fan(s) on/ off status. Terminals 8,9 and 10 are volt-free change-over contacts that mimic the emergency stop status. 10.0 Pre Commissioning The Ventam 85 Interlock Panel is supplied fitted with links in various terminals. Do not remove these links until pre-commissioning is completed. Do not connect the valve or pressure switch(es)s until pre-commissioning is completed. Refer to the supplied schematic wiring diagrams in conjunction with these instructions. Isolate and make safe all Gas and Electrical services including the fan power supply and make known to others that works are commencing. Install the Interlock Panel, the Gas Isolation Valve and the Fan Pressure switch(es). Unit(s). Install the electrical supply to the Control Panel via an un-switched fused spur. Install 1.5 mm² two-core flex between the fan Pressure switch(es). Unit(s) and the Control Panel. Install cables (to suit the valve size) between the Ventam 85 Control Panel and the Gas Valve. Re-set the Emergency Stop on the Control Panel by turning the button in the direction of the arrows on the button. Ensure it is safe to start fan(s). Check all panel terminations are secure. Use the correct tool and do not over-tighten. Ensure that the following factory installed terminal links are fitted (if not fit them now) - Link between terminals 1 and 2, link between terminals 3 and 4, link between terminals 11 and 12. 10.1 Connect the panel power supply to terminals L1, N1 and E1 and power up the panel. Panel should indicate Power On and Fan(s) On - Terminal 20 (Valve supply terminal) should be at 240Vac. Deleted 10.3 Remove link from terminal one. Panel should indicate Fan(s) Off - Terminal 20 (Valve supply terminal) should be at zero Volts. Replace link in terminal one. Note that the short time delay between switching off the fan and the panel actually sensing that the Fan is off is due to the time taken for the fan to stop rotating. 10.4 Check Terminal 20 is at 240Vac (If not, re-set Emergency Stop Button on front of panel). Press Emergency Stop Button on the front of panel - Terminal 20 should read Zero Volts. Re-set Emergency Stop Button on front of panel - Terminal 20 should read 240Vac. 10.5 Isolate power to the panel and connect the site cabling for the valve and pressure switch(es).(s)as per supplied wiring diagrams. If pressure switch(es).s are fitted in terminals 1 & 2 AND 3 & 4, remove the Panel links from these terminals. Page 3 of 8

11.0 System Commissioning 11.1 Confirm that the cables to the gas proving valve are terminated correctly. Incorrect terminations will cause system and valve damage. 11.2 Deleted 11.3 Ensure all emergency stop buttons are reset. 11.4 Turn on all interlocked fan(s) Increase fan speeds until panel indicates Fan(s) On. Panel should indicate Fan(s) on. 11.5 Switch power off and then back on again to each interlocked fan in turn Panel should indicate Fan(s) off and then Fan(s) on for each fan in turn. Note that it will take up to thirty seconds for the Fan(s) off light to come on due to the time it takes for the fan to stop turning! 11.6 Ensure fan(s) are on and increase fan speed to the level required to indicate Fan(s) On. Depress emergency stop button on the front of panel panel will indicate Emergency Stop. Re-set emergency stop button on the front of panel. 11.7 Testing additional emergency Stop buttons. Ensure fan(s) are on and increase fan speed to the level required to indicate Fan(s) On. Depress additional emergency stop button panel will indicate Emergency Stop. Re-set additional emergency stop button on the front of panel. Repeat step 11.7 for each additional emergency stop button fitted. 12.0 Gas Proving check that gas cannot come on if fans are off Turn off one of the fans - Fan(s) off lamp and Gas Off lamp will be lit. Operate the Gas Power Switch by switching it to the right.. Depress the Start Gas Proving button and keep button depressed for thirty seconds. THE GAS ON PANEL LIGHT SHOULD NOT COME ON WHILE ANY FAN IS OFF. 13.0 Gas Proving Ensure Fan(s) On light is on. Ensure gas supply to valve is turned on. Ensure all gas appliances are isolated. Operate the Gas Power Switch by switching it to the right. Depress the Start Gas Proving button and keep button depressed until the Gas On panel light comes on. NOTE IF IT TAKES LONGER THAN ONE MINUTE FOR THE GAS ON LIGHT TO COME ON,CHECK THAT ALL VALVES ARE CLOSED AND THAT PIPE-WORK IS FREE FROM LEAKS. When Gas On light is lit purge air from the system and commission appliances. Turn off all gas appliances and close all appliance isolation valves. 14.1 Gas Proving Gas On light should still be lit. Turn off all gas appliances. Turn off one of the fans Fans Off AND Gas Off light should be lit on panel. Page 4 of 8

Turn fan back on Fans On light should be lit on panel. Repeat section 13.0 - Gas Proving part one Gas On panel light will come on. Repeat step 14.1 for each interlocked fan 14.2 Gas Proving Gas On light should still be lit. Turn off all gas appliances. Depress emergency stop button on the front of panel panel will indicate Emergency Stop AND Gas Off. Re-set the emergency stop button on the front of the panel, repeat step 13.0 Gas On panel light will come on. Repeat step 14.2 for each additional emergency stop button fitted. 14.3 Fan pressure switch Adjustments Fan pressure switches can be adjusted to trip the gas valve at the required air flow rate. As a guide, the fans should trip the valve if the fans are reduced to below 50% of full speed, but the ventilation system specifications for minimum flow rates must be followed. Typically, if the speed controller minimum is to be set at 50% of max fan speed, then the Fan pressure switch should be set to turn off the gas at 45%. Allow a tolerance for the ventilation system to settle down and for the filters to become partially blocked etc. If the speed controller is fitted with a minimum speed adjustment pot (on the rear of the speed controller board), ALWAYS set this to set the minimum speed that the fan will run and this will prevent user problems and premature fan failure. A typical installation requires that the fresh air supply flow is at 85% of the extraction air flow, and this can be allowed for in fan pressure switch adjustments to control minimum. 14.4 Using a current monitor to monitor the fan(s) A current monitor may be used instead of a fan pressure switch to check that the fan is operating. The current monitor must be set up to ensure that the gas turns off if the fan is turned down too low or turned off. Adjust the current monitor so that this happens and test it. As a guide, the fans should trip the valve if the fans are reduced to below 50% of full speed, but the ventilation system specifications for minimum flow rates must be followed. A typical installation requires that the fresh air supply flow is at 85% of the extraction air flow, and this can be allowed for in current monitor adjustments to control minimum. The current monitor should be installed so that the volt free current monitor contact is CLOSED when the fan is running. This contact must be connected into panel terminals 1+2 OR 3+4. 14.3 Instruct site staff in correct system operation and instruct staff to clean filters regularly. Advise site staff NOT to decrease fan(s) speed or gas valve will NOTOPERATE!!!! Ask the user to start the fans, increase the fan speed etc to ensure the user is familiar with and understands system operation and that the system is installed for their safety. Page 5 of 8

Control Schematic Gas proving Valve Gas Flow 240vac signal to Isolation valve VENTAM 85 CONTROL SYSTEM Flow Sensor Status signal Com N/O -ve Plastic tubing Air Flow Fan Extract fan isolator or speed controller Air Flow pressure switch mounted adjacent to each fan. Extract Duct Page 6 of 8

One line diagram for electrical first fix Note 2 Un-switched fused spur. Panel power supply 240Vac 5A single phase. Note 4 Note 7 Ventam 85 Control Panel Mounted on wall in kitchen, adjacent to exit door. approx. 1600mm AFFL Note 3 Supply Air Fan Flow Sensor next to fan Ventam Systems Ltd Unit D4 Seedbed Business Centre Vanguard Way Shoeburyness Essex SS3 9QY Phone 01702 382 307 Fax 01702 382 340 Note 3 Panel dimensions H 310mm W 230mm D 160mm Note 3 Canopy Extract Air Fan Flow Sensor, next to fan Additional Emergency Stop Button(s) Note 5 Gas Isolation Valve 240Vac Note 6 Notes 1 NOTE THAT FAN(S) POWER SUPPLY CABLES / ISOLATORS / SPEED CONTROLLERS ARE NOT SHOWN ON THIS DIAGRAM AND MUST ALSO BE INSTALLED TO SUIT THE APPLICATION. 2 Fused spur to be wall mounted adjacent to panel. 3 1.5mm² two core cable. Leave 500mm-length slack at panel. Leave 2-metre length slack at fan end 4 2.5mm² two core and earth cable. Leave 500mm-length slack at panel. 5 THREE OFF 1.5mm² Three core (two core AND earth) cables. Leave 2-metre length slack at valve end, 500mm-length slack at panel end. Terminate cable in flex outlet plate adj. to valve. 6 Panel provides a switched 240Vac supply to operate the gas isolation valve. 7 Panel should be mounted in an accessible position, approx. 1.6m AFFL. Page 7 of 8

Ventam 85 Gas Proving & Interlock wiring schematic 1 Ventam Systems Ltd Unit D4 Seedbed Business Centre Vanguard Way Shoeburyness Essex SS3 9QY Phone 01702 382 307 Fax 01702 382 340 Panel Terminals 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 21 22 23 24 25 2 3 N/O C EXTRACT FAN PRESSURE SWITCH N/C N/O C VOLT FREE FAN REPEAT CONTACTS 2 3 N/O C INLET FAN PRESSURE SWITCH N/C N/O C VOLT FREE EMERGENCY STOP REPEAT CONTACTS ADDITIONAL EMERGENCY STOP BUTTON 3 2 C N/O E GAS VALVE PRESSURE SWITCH E N L MAIN GAS VALVE 1 2 L N E GAS BYPASS VALVE L N E Incoming panel supply (240volt ac) Notes 1 When fan pressure switch wiring is connected to terminals 1 + 2 OR 3 + 4, the factory fitted link must be removed. 2 Link between terminals 11 and 12 must be installed unless (Normally Closed Volt- Free Contact) emergency stop buttons are fitted in series to these terminals. 3 Terminal 20 MUST NOT BE USED. 4 Dungs gas pressure switch connections:- Terminal 2 normally open, terminal 3 Common. 5 Please phone 01702 382 307 if assistance is required. Page 8 of 8