Product Data. CK5A, CK5B, CK5P Furnace N-Coils. Sizes A018 thru A060

Similar documents
CASED HORIZONTAL FURNACE COIL. Model CK3B. Form No. SS-CK3B-01 FEATURES

Model 26.5 WEAU242AA WEAU244BA 29.0 WEAU242BA 29.0 WEAU304AA 33.0 WEAU302AA WEAU304BA 33.0 WEAU302BA 33.

Product Data. CAPVP, CARVP, CAPVU, CARVU Evaporator Coil A Coil --- Cased and Uncased Upflow, Downflow CAPVP / CARVP

Product Data CAPVP, CARVP, CAPVU, CARVU EVAPORATOR COIL A COIL - CASED AND UNCASED UPFLOW, DOWNFLOW DESIGN FEATURES

Product Data CAPMP, CARMP EVAPORATOR COIL A COIL - CASED MULTIPOISE CAPMP / CARMP CAPMP / CARMP (3619, 4823, 6025)

FMU4X, FMC4X FMU4P, FMC4P

Product Data. FB4CS, FB4CQ (50 Hz) Direct Expansion Fan Coil R- 410A Refrigerant Sizes 018 thru 060 AIR HANDLER TECHNOLOGY AT ITS FINEST

Product Data. FA4B FB4B FC4C Direct Expansion Fan Coil. Sizes 018 thru 070. Air Handling Technology At Its Finest

FA4B FB4B FC4C DIRECT EXPANSION FAN COIL. Sizes 018 thru 070. Form No. PDS FA4B Air Handling Technology At Its Finest

Product Data. FA4A FB4A FC4B Direct Expansion Fan Coil. Sizes 018 thru 070. Air Handling Technology At Its Finest

TECHNICAL SPECIFICATIONS

Coils Designed to Fit Your Requirements. Temtrol Manufacturing OEM & Replacement Coils Since 1955

AIR CONDITIONERS WA14**W SERIES

Evaporator (DX) Freon Applications 1 12 Tons MHF

AIR CONDITIONERS WA14 SERIES

D A T A S H E E T. Technical Data. Maximum Working Gauge Pressure (bar) Capillary Tube Length (m) 1.5 (5Ft) Burst Gauge Pressure (bar) 234.

ACCESSORY KIT INSTALLATION INSTRUCTIONS

TWC Services, Inc. Structured On-The-Job Training for JT- 1, 2, 3

4HP15 PRODUCT SPECIFICATIONS 15 SEER SPLIT SYSTEM HEAT PUMP

2-step solenoid valve Type ICLX

2-step solenoid valve Type ICLX

FSH1BG Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Ultra High Efficiency Heat Pump, Up to 19 SEER Residential System 2-5 Ton Capacities

Field Installed Options: * Louvered or non-louvered ceiling access panels. * Time delay relay.

AIR CONDITIONERS. Features. Manufactured for Fujitsu General America, Inc. Fairfield, NJ. FORM NO. AFJ-222 Supersedes Form No.

Solenoid Valves, one - or two step, on/off ICLX

Solenoid valves, two-step on/off Type PMLX REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Pressure Dump Valve Service Kit for Series 2300 Units

MAINLINE MLA14 AIR CONDITIONERS

AIR CONDITIONERS. Features. Manufactured for Fujitsu General America, Inc. Fairfield, NJ. FORM NO. AFJ-220 Supersedes Form No.

Fluid Dispensing Systems H O S E R E E L S H O S E S HOSE REELS

Dual position solenoid valve Type ICSH 25-80

AIR CONDITIONERS. Features. Manufactured for Fujitsu General America, Inc. Fairfield, NJ. FORM NO. AFJ-221 Supersedes Form No.

System Soft-optimization Tests of Refrigerant R-32 in a 6-ton Rooftop Packaged Air-Conditioner

INSTRUCTION MANUAL MST AFTERCOOLER SYSTEM MODEL

Ducted Reverse Cycle Air Conditioning of Distinction

Pressure Dump Valve Service Kit for Series 3000 Units

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

INDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES

Flow Sensors & Hydrometers Specification Sheet

3/8" Dr. Air Butterfly Impact Wrench

Instructions. Control Solution ICF 20-4, ICF 25-4, ICF ICF 40-4, ICF 20-6, ICF 25-6, ICF 32-6, ICF 40-6, Direction and position.

Gas powered stop valves, type GPLX REFRIGERATION AND AIR CONDITIONING. Technical leaflet

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

Quick Start SunPump Install

Gas Furnaces 95AF. Warranty Heat Exchanger - 20 Year Limited Parts - 5 Year Limited. 95% AFUE 44,000 to 110,000 Btuh Input 2 to 5 Tons Add-On Cooling

ATD LB PRESSURE BLASTER INSTRUCTION MANUAL

The Shand & Jurs Model Vapor Guard Tank Blanketing Valve

Valve Station ICF 15, 20 and 25

Food Service Industry Hose

V48 Series 3-Way Pressure-Actuated Water-Regulating Valves With Union Fittings

Series V48. 3-Way Pressure Actuated Modulating Valves. Product Bulletin. Features. Pressure balanced design. Free movement of all parts

Variable Area Flow Meters

Gas Furnaces 95AF2V. Warranty Heat Exchanger - 20 Year Limited Parts - 5 Year Limited

TECHNICAL DATA. Q= Cv S

MAINTENANCE AND OPERATING MANUAL

36C/36D HSI, DSI Proven Pilot Gas Valves INSTALLATION INSTRUCTIONS

Water Cooling and Evaporator Coils. Types HI-F5 and E-F5. Catalog 411-9

R600 and HSRL Series Instruction Manual

TECHNICAL DATA. Q = C v P S

Inert Air (N2) Systems Manual

ACCESSORY KIT INSTALLATION INSTRUCTIONS

Series V47 Temperature Actuated Modulating Valves

R-410A 50% R-32 50% R-125.

MODEL: SA13. Air Conditioners. Sure Comfort SA13. Air Conditioners

GETZ EQUIPMENT INNOVATORS RECOVERY SYSTEM CLEAN AGENT FE-36 / HALOTRON 1 PART NO. 4G59751 OPERATIONS MANUAL

Manual. Bypass Feeder. Installation Maintenance Repair Manual. Chemical Addition and Filtering

ACCESSORY KIT INSTALLATION INSTRUCTIONS

VB-7263 Series. Application. Features. Applicable Literature

TECHNICAL DATA. Q = C v P S

VB-7213 Series. Application. Features. Applicable Literature. 1/2" to 2" Screwed NPT Stem Up Open, Two-Way Valves General Instructions

DISCLAIMER OF WARRANTIES AND LIMITATION OF LIABILITIES

PORTABLE 5 GALLON AIR TANK ASSEMBLY & OPERATING INSTRUCTIONS

e G) GOVERNOR t,5 ii:i! Line Pressure Regulators

PRO-50 Instrument Supply Regulator

V248 Series 3-Way Pressure-Actuated Water-Regulating Valves for High-Pressure Refrigerants

Capacity regulator (hot gas bypass)

TECHNICAL DATA OBSOLETE

V46 Series 2-Way Pressure-Actuated Water-Regulating Valves With Union Fittings

PAPR Flow Tester. instructions. part no WARNING

e G) GOVERNOR t,5 ii:i! Line Pressure Regulators

R122H, R222, R232A, and R232E Series Instruction Manual

Owner's Manual Sealweld SuperSeal II Pump

Tank Blanketing Pressure Regulators RHPS Series

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified

3" UC Ultra-Chuck Durable Lightweight Air Inflated Bladder Chuck Operation/Repair Manual. (76.2 mm) DOUBLE E COMPANY, INC.

installation instructions

V248 Series 3-Way Pressure-Actuated. Water-Regulating Valves for High-Pressure

ELITE Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,800 to 60,000 Btuh AIR CONDITIONERS EL16XC1 PRODUCT SPECIFICATIONS

SDS -Series 4C-D201/-D202 Supplemental Drying System User s Manual

Ball Float Steam Trap UNA 45 MAX, UNA 46 MAX, UNA 46A MAX PN 40/Class 300 DN 40, 50, 65

Technical data. Back pressure limit: 27.5% of set pressure. Capacity certification: ASME Boiler & Pressure Vessel Code Section I and VIII

Model 8800A. Pressure Relief and Vacuum Breaker Valve with Flame Arrester

Installation Instructions

TECHNICAL DATA. Q = C v P S

Glycol Systems. Engineering Manual. 1/2 to 10 Hp Pumps 3 to 190 Tons Drycoolers (60 Hz Data) Pump Packages & Remote Outdoor Drycoolers

C Lite CAD SERIES. ACS Approved. Patented CAD-2 diaphragm technology. Rugged copolymer polypropylene base. Quality brass air stem with o-ring seal

Standard Operating and Maintenance Instructions for Pumping System Model PS-90

Models: C62/63/64-A/D

Setup Guide for your HVO Naked Drone

VBS-9263 Series. Application. Features. Applicable Literature

Transcription:

Product Data CK5A, CK5B, CK5P Furnace N-Coils Sizes A018 thru A060 This vertical design N-coil is a furnace coil designed to provide the highest standards of reliability and durability. The coils are offered in 3 configurations. The CK5A has a painted case and comes with a piston. The CK5B has an embossed case and comes with a piston. Both the CK5A and CK5B can be used with R-22 or Puron systems. The third coil, the CK5P, is in a painted case and comes with a Puron TXV and is specific to Puron systems. The coils are offered in standard, overhang, and wide configurations for use in multiple installation applications. Additionally, the cased coils are offered in a Transition configuration, which is designed to fit two different furnace widths without field modification. Easy maintenance is provided as the coil slides out of the cabinet after removing the access door and service panel. The coils are available in sizes 018 through 060 (1-1/2 to 5 tons). Two full lines of Tin-Plated copper coil models are available (CK5A and CK5P). T models are built with special hairpins Tin- Plated to resist both general pitting corrosion and excessive indoor corrosion Formicary Corrosion. (Formicary Corrosion is an industry phenomenon). COMMON FEATURES Water Management The CK coil design does an excellent job of water management. The coils are designed to avoid water blow-off Copyright 2003 Carrier Corporation Form No. CK5A-5PD

into the ducts by directing condensate away from the fins and into the drain pan. The coil s drain pan design provides improved condensate removal into the drain. This improves indoor air quality. Durable Condensate Pan Each coil is equipped with a corrosion resistant condensate drain pan. The condensate drain pan is designed with a slope to help ensure proper drainage, improved moisture removal, and home comfort. Compact Design Unique design offers as much as 2 in. less in height to aid in tight installations. Brass Inserts Every condensate pan features two 3/4 in. female threaded brass insert connections. The unique brass inserts provide for a leak-free condensate line connection to prevent water damage. Refrigerant Connections The coils are provided with proven sweatconnections for leak-free operation maintaining system reliability. Burst Pressures These coils meet or exceed burst pressure of 2100 psi which is at least three to five times the pressure they will see in actual application. External Piston Location Provides easy access to the piston metering device, for quick installations and standard service procedures. Liquid Line Bracket Holds the piston body in place for quick, safe piston access without needing a back-up wrench. Teflon Ring The ring, installed inside the liquid line connection, is the best option for preventing refrigerant leaks and future service calls. Teflon works with both Puron and R-22 Refrigerant. Protective Tube Sheets Protect the durable copper tubing from being damaged during the manufacturing and installation process. Warranty All CK5A/CK5B/CK5P coils feature a 5-year limited warranty on parts, with additional extended warranties available for the system. 2

Model number nomenclature C K 5 A X A 018 (0,T)14 C Coil 018 1-1/2 Ton 024 2 Ton 030 2-1/2 Ton Etc. (0,T)14 14-3/16 in. (0,T)17 17-1/2 in. (0,T)21 21 in. (0,T)24 24-1/2 in. K Cased, N-Coil 5 Upflow/Downflow A Standard E High Efficiency T Transition W Wide X Max Cap Position A Painted B Embossed P Puron, TXV Painted 0 Standard Copper Coil T Tin-Plated Copper Coil UNITARY AIR CONDITIONING UNITARY HEAT PUMP REGISTERED QUALITY SYSTEM MANUFACTURER CERTIFIED TO ARI AS COMPLYING WITH ARI EQUIPMENT STANDARD 210 MANUFACTURER CERTIFIED TO ARI AS COMPLYING WITH CERTIFICATION APPLIES ONLY WHEN USED WITH PROPER COMPONENTS AS LISTED WITH ARI ARI EQUIPMENT STANDARD 240 3

DIMENSIONS (In.) UNIT SERIES A B C D E F G CK5(A,P)XA018(0,T)14* CK5BXA018014* CK5(A,P)XA024(0,T)14* CK5BXA024014* CK5(A,P)XW024(0,T)17 CK5BXW024017 CK5(A,P)XA030(0,T)14* CK5BXA030014* CK5(A,P)XW030(0,T)17 CK5BXW030017 CK5(A,P)XA036(0,T)17* CK5BXA036017* CK5(A,P)XT036(0,T)17* CK5BXT036017* CK5(A,P)XW036(0,T)21 CK5BXW036021 CK5(A,P)XA042(0,T)21* CK5BXA042021* CK5(A,P)XT042(0,T)21* CK5BXT042021* CK5(A,P)XA048(0,T)21* CK5BXA048021* CK5(A,P)XE042(0,T)17 CK5BXE042017 CK5(A,P)XT048(0,T)21* CK5BXT048021* CK5(A,P)XW048(0,T)24 CK5BXW048024 CK5(A,P)XA060(0,T)24* CK5BXA060024* CK5(A,P)XT060(0,T)24* CK5BXT060024* CK5(A,P)XX060(0,T)24 CK5BXX060024 SHIPPING WEIGHT (LB) A 14-3/16 12-5/8 12-7/16 5 5/8 2-1/8 1-3/8 29-1/2 A 14-3/16 12-5/8 12-7/16 7-1/16 5/8 2-1/8 1-3/8 33 A 17-1/2 12-5/8 15-3/4 6-11/16 5/8 2-1/8 1-3/8 34 A 14-3/16 14-5/8 12-7/16 9-1/16 3/4 2-1/8 1-3/8 36-1/2 A 17-1/2 14-5/8 15-3/4 8-13/16 3/4 2-1/8 1-3/8 38-1/2 B 17-1/2 17.0 15-3/4 10-13/16 3/4 2-1/8 1-3/8 44 A 17-1/2 19-1/4 15-3/4 13-1/16 3/4 4-3/8 3-5/8 50 B 21 17 19-1/4 10-1/2 3/4 2-1/8 1-3/8 45 B 21 17 19-1/4 10-1/2 7/8 2-1/8 1-3/8 45 A 21 19-1/4 19-1/4 12-3/4 7/8 4-3/8 3-5/8 53 B 21 19 19-1/4 12-11/16 7/8 2-1/8 1-3/8 48-1/2 B 17-1/2 19 15-3/4 12-15/16 7/8 2-1/8 1-3/8 46-1/2 A 21 21-1/4 19-1/4 14-15/16 7/8 4-3/8 3-5/8 57 B 24-1/2 19 22-3/4 12-3/16 7/8 2-1/8 1-3/8 50-1/2 A 24-1/2 22-1/16 22-3/4 16-1/2 7/8 2-1/8 1-3/8 63 A 24-1/2 24-5/16 22-3/4 18-3/4 7/8 4-3/8 3-5/8 70 A 24-1/2 26-5/16 22-3/4 14-1/4 7/8 2-1/8 1-3/8 72 * In these models the coil can be removed from the casing and installed as an uncased coil without needing to field fabricate the coil enclosure to prevent air bypass. NOTE: For the 10th digit position in the model number, 0 = standard copper and T = tin-plated copper. 3 8 I.D. Puron TXV Connection CK5P NOTE: 1. Series designation is the 14th position of unit model number. 9 16 7 8 C 1 9 16 21 18 9 16 B E SUCTION LINE 2 5 8 2 1 8 3 8 I.D. Liquid Line CK5A/B 2 3 4 IN.PLUGGED DRAIN D F G 3 4 IN. NPT DRAIN 1 7 8 1 9 16 3 1 16 A FRONT RIGHT SIDE A03134 4

Performance data GROSS COOLING CAPACITIES (MBH) UNIT SIZE A018 A024 W024 A030 W030 A036 T036 W036 A042 T042 A048 E042 T048 W048 SATURATED TEMPERATURE LEAVING EVAPORATOR ( F) INDOOR COIL AIR 30 35 40 45 50 CFM EWB TC SHC BF TC SHC BF TC SHC BF TC SHC BF TC SHC BF 450 600 750 600 800 1000 750 1000 1250 900 1200 1500 1050 1400 1750 1200 1600 2000 CFM Cubic Ft per Minute EWB Entering Wet Bulb ( F) TC Gross Cooling Capacity 1000 Btuh SHC Gross Sensible Capacity 1000 Btuh BF Bypass Factor MBH 1000 Btuh 72 31.9 14.8 0.00 28.9 13.4 0.00 26.0 12.1 0.00 22.6 10.7 0.07 18.5 9.04 0.06 67 26.8 15.8 0.07 23.7 14.3 0.06 20.5 12.8 0.05 16.7 11.2 0.04 12.5 9.40 0.05 62 21.8 16.6 0.04 18.6 14.9 0.04 15.4 13.3 0.05 12.3 11.7 0.08 9.95 9.95 0.18 72 37.5 17.3 0.00 34.0 15.8 0.00 30.5 14.2 0.16 26.5 12.6 0.11 22.1 10.9 0.09 67 31.3 18.7 0.10 27.8 17.1 0.09 24.3 15.5 0.08 20.1 13.7 0.07 15.2 11.7 0.09 62 25.8 20.1 0.08 22.2 18.4 0.08 18.6 16.6 0.08 15.2 14.7 0.11 12.5 12.5 0.22 72 41.7 19.2 0.00 37.9 17.6 0.00 34.0 16.0 0.17 29.6 14.2 0.14 24.7 12.4 0.12 67 35.1 21.2 0.13 31.0 19.5 0.12 26.9 17.7 0.11 22.6 15.9 0.11 17.4 13.7 0.12 62 28.4 22.9 0.10 24.9 21.3 0.10 21.4 19.6 0.11 17.7 17.5 0.14 14.8 14.8 0.26 72 38.7 17.9 0.00 35.4 16.4 0.00 32.0 15.0 0.13 28.1 13.3 0.08 23.7 11.6 0.07 67 32.6 19.5 0.07 29.1 17.9 0.06 25.6 16.3 0.06 21.5 14.5 0.05 16.6 12.5 0.06 62 27.0 20.9 0.05 23.4 19.2 0.05 19.8 17.4 0.05 16.2 15.5 0.08 13.3 13.3 0.18 72 44.0 20.4 0.21 40.4 18.9 0.17 36.8 17.3 0.13 32.4 15.6 0.11 27.2 13.7 0.10 67 37.4 22.8 0.10 33.5 21.1 0.10 29.5 19.4 0.09 25.0 17.5 0.08 19.7 15.4 0.09 62 30.6 25.0 0.07 27.0 23.2 0.08 23.4 21.4 0.09 19.7 19.3 0.12 16.6 16.6 0.23 72 47.9 22.3 0.18 44.0 20.7 0.17 40.1 19.2 0.16 35.5 17.4 0.14 30.0 15.4 0.13 67 40.7 25.5 0.13 36.6 23.8 0.13 32.4 22.0 0.12 27.3 20.0 0.11 21.9 17.9 0.12 62 33.7 28.6 0.10 30.0 26.7 0.11 26.2 24.9 0.12 22.7 22.5 0.17 19.4 19.4 0.28 72 54.4 25.3 0.00 48.7 22.7 0.00 43.1 20.1 0.00 36.6 17.3 0.07 29.3 14.5 0.06 67 45.1 26.5 0.07 39.1 23.7 0.07 33.2 20.9 0.06 26.7 18.1 0.05 20.0 15.2 0.08 62 36.0 27.3 0.05 30.5 24.5 0.06 25.0 21.8 0.07 19.7 19.0 0.09 16.1 16.1 0.21 72 64.1 29.5 0.00 57.7 26.7 0.00 51.2 23.9 0.19 43.9 20.9 0.12 35.2 17.6 0.10 67 53.6 31.8 0.11 46.8 28.7 0.10 40.1 25.6 0.10 32.3 22.3 0.09 24.1 18.8 0.11 62 43.4 33.4 0.10 36.9 30.3 0.10 30.4 27.2 0.10 24.3 24.0 0.12 20.1 20.1 0.26 72 72.1 33.0 0.00 64.7 29.9 0.00 57.3 26.8 0.20 49.4 23.7 0.15 40.1 20.3 0.14 67 59.6 35.8 0.14 52.4 32.7 0.14 45.3 29.5 0.13 36.8 25.9 0.13 27.5 22.0 0.15 62 49.0 38.4 0.14 42.0 35.2 0.13 35.0 32.1 0.13 28.6 28.4 0.16 23.7 23.7 0.30 72 63.4 29.6 0.00 57.2 26.8 0.00 50.9 23.9 0.00 44.3 21.0 0.00 36.3 17.9 0.00 67 52.1 31.0 0.00 46.0 28.1 0.00 39.8 25.1 0.00 32.8 22.1 0.00 24.9 18.8 0.01 62 42.8 32.7 0.00 36.7 29.6 0.00 30.5 26.6 0.01 23.9 23.0 0.04 19.2 19.2 0.18 72 75.1 34.7 0.00 67.8 31.6 0.00 60.5 28.5 0.05 52.1 25.1 0.03 43.4 21.8 0.02 67 61.6 37.2 0.02 54.5 34.0 0.02 47.5 30.8 0.02 39.3 27.3 0.02 30.2 23.4 0.04 62 51.1 40.2 0.02 44.0 36.7 0.03 36.9 33.2 0.03 29.3 28.9 0.08 24.2 24.2 0.22 72 83.3 38.5 0.17 75.5 35.3 0.13 67.6 32.1 0.09 58.5 28.5 0.06 48.4 24.8 0.06 67 69.4 42.5 0.06 61.3 38.9 0.06 53.1 35.4 0.05 44.4 31.7 0.05 34.5 27.5 0.07 62 56.6 46.2 0.04 49.3 42.5 0.06 42.0 38.8 0.07 34.3 34.3 0.11 28.8 28.8 0.25 72 75.4 35.0 0.00 68.0 31.8 0.00 60.7 28.6 0.02 52.7 25.3 0.00 43.6 21.7 0.00 67 62.1 37.3 0.00 55.0 34.0 0.00 47.8 30.7 0.00 39.3 26.9 0.01 30.2 23.1 0.03 62 51.5 39.8 0.01 44.2 36.2 0.01 36.9 32.7 0.02 29.1 28.3 0.06 23.7 23.7 0.20 72 87.8 40.6 0.18 79.4 37.1 0.13 71.0 33.6 0.07 61.3 29.8 0.05 51.0 25.9 0.05 67 72.9 44.4 0.05 64.4 40.7 0.04 55.9 36.9 0.04 46.7 33.0 0.04 36.1 28.5 0.06 62 60.0 48.3 0.03 52.0 44.3 0.05 44.0 40.3 0.06 35.5 35.5 0.10 29.7 29.7 0.24 72 96.3 44.6 0.16 87.4 41.1 0.13 78.5 37.5 0.11 67.9 33.5 0.09 55.9 29.1 0.09 67 80.8 50.1 0.08 71.5 46.1 0.08 62.2 42.2 0.08 51.9 37.9 0.08 40.9 33.4 0.10 62 65.7 55.1 0.07 57.6 50.9 0.08 49.5 46.6 0.10 41.7 41.7 0.15 35.0 35.0 0.28 72 79.8 36.9 0.00 72.6 33.7 0.00 65.4 30.6 0.12 57.0 27.1 0.08 47.5 23.4 0.07 67 66.6 39.8 0.07 59.1 36.4 0.06 51.7 33.0 0.06 43.2 29.3 0.05 33.3 25.2 0.07 62 55.2 42.8 0.06 47.6 39.1 0.06 40.0 35.4 0.06 32.2 31.3 0.08 26.7 26.7 0.20 72 91.0 42.1 0.22 83.0 38.7 0.18 75.0 35.4 0.13 65.4 31.7 0.11 54.5 27.6 0.10 67 76.7 46.9 0.10 68.1 43.1 0.10 59.5 39.4 0.09 50.1 35.4 0.09 39.4 31.0 0.11 62 62.7 51.0 0.08 54.9 47.2 0.09 47.1 43.4 0.10 39.3 39.0 0.13 33.1 33.1 0.25 72 99.2 46.1 0.19 90.7 42.7 0.17 82.2 39.4 0.15 72.0 35.5 0.14 60.0 31.2 0.13 67 84.0 52.6 0.13 74.8 48.8 0.13 65.7 44.9 0.12 55.1 40.5 0.12 44.0 36.0 0.13 62 69.0 58.5 0.11 60.8 54.3 0.12 52.6 50.2 0.14 45.4 45.4 0.18 38.5 38.5 0.30 5

Performance data continued UNIT SIZE A060 T060 X060 CFM Cubic Ft per Minute EWB Entering Wet Bulb ( F) LWB Leaving Wet Bulb ( F) TC Gross Cooling Capacity 1000 Btuh SHC Gross Sensible Capacity 1000 Btuh BF Bypass Factor MBH 1000 Btuh GROSS COOLING CAPACITIES (MBH) SATURATED TEMPERATURE LEAVING EVAPORATOR ( F) INDOOR COIL AIR 30 35 40 45 50 CFM EWB TC SHC BF TC SHC BF TC SHC BF TC SHC BF TC SHC BF 1600 2000 2400 1600 2000 2400 72 101.0 46.7 0.00 90.8 42.2 0.00 80.4 37.6 0.12 69.1 33.0 0.08 56.0 28.0 0.07 67 83.8 49.9 0.07 73.5 45.2 0.07 63.1 40.5 0.06 51.1 35.3 0.06 38.0 29.8 0.08 62 68.7 53.0 0.07 58.2 48.0 0.07 47.7 43.0 0.07 38.2 37.6 0.11 31.6 31.6 0.24 72 113.0 52.2 0.00 102.0 47.4 0.00 90.4 42.6 0.14 77.5 37.5 0.11 63.5 32.3 0.10 67 94.0 56.8 0.10 82.6 51.8 0.10 71.2 46.8 0.09 58.5 41.3 0.10 43.7 35.2 0.11 62 77.0 61.2 0.09 66.0 56.0 0.10 55.1 50.7 0.10 45.0 44.7 0.15 37.3 37.3 0.28 72 123.0 56.6 0.26 111.0 51.6 0.21 98.4 46.7 0.16 84.2 41.2 0.13 69.4 35.8 0.13 67 103.0 62.8 0.13 89.9 57.4 0.13 77.3 52.0 0.12 64.3 46.5 0.12 48.3 40.0 0.14 62 83.0 68.4 0.11 72.2 63.0 0.12 61.4 57.5 0.13 51.1 51.1 0.18 42.5 42.5 0.32 72 106.0 49.0 0.00 94.4 44.0 0.00 83.1 39.0 0.07 71.6 34.3 0.05 58.4 29.1 0.06 67 85.7 51.3 0.05 75.4 46.5 0.05 65.1 41.7 0.05 52.9 36.4 0.05 39.8 30.9 0.07 62 70.8 54.8 0.04 59.6 49.2 0.05 48.4 43.7 0.06 38.0 37.2 0.13 31.1 31.1 0.26 72 116.0 53.7 0.18 105.0 49.2 0.14 94.7 44.7 0.10 81.6 39.5 0.08 67.3 34.0 0.08 67 97.6 59.1 0.07 86.1 54.0 0.07 74.5 48.8 0.07 61.4 43.1 0.07 46.4 36.9 0.09 62 80.0 64.0 0.05 68.4 58.1 0.07 56.8 52.1 0.09 45.0 44.7 0.16 37.4 37.4 0.29 72 128.0 59.4 0.17 116.0 54.4 0.15 104.0 49.4 0.12 89.9 43.9 0.10 74.1 38.0 0.10 67 108.0 66.0 0.09 94.7 60.4 0.09 81.8 54.7 0.10 67.9 48.8 0.10 51.9 42.3 0.11 62 86.4 71.3 0.08 75.0 65.4 0.10 63.6 59.5 0.12 52.1 52.1 0.17 43.3 43.3 0.31 3. Direct interpolation is permissible. Do not extrapolate. 4. SHC is based on 80 F db temperature of air entering coil. Below 80 F db, subtract (Correction Factor x CFM) from SHC. Above 80 F db, add (Correction Factor x CFM) to SHC. 5. All data points are based on 10 F superheat leaving coil. 6. Bypass Factor = 0 indicates no psychometric solution. Use bypass factor of next lower EWB for approximation. NOTES: 1. Contact manufacturer for cooling capacities at conditions other than shown in table. 2. Formulas: sensible heat cap. Leaving db = entering db 1.09 x CFM Leaving wb = wb corresponding to enthalpy of air leaving coil (h LWB ) total capacity (Btuh) h LWB = h EWB 4.5 x CFM where h EWB = enthalpy of air entering coil. ENTERING AIR DRY BULB TEMPERATURE ( F) 79 78 77 76 75 UNDER 75 BYPASS 81 82 83 84 84 Over 85 FACTOR Correction Factor 0.10 0.98 1.96 2.94 3.92 4.91 0.20 0.87 1.74 2.62 3.49 4.36 Use formula 0.30 0.76 1.53 2.29 3.05 3.82 shown below Interpolation is permissible. Correction Factor = 1.09 x (1 BF) x (db 80) UNIT CK5P-018, 024, 030 CK5P-036, 042 CK5P-048 CK5P-060 INDOOR COIL TXV FACTORY-INSTALLED INDOOR TXV SIZE EA36Y124 EA36Y134 EA36Y144 EA36Y154 6

COIL STATIC PRESSURE DROP (In. WC) UNIT SIZE BULB AIR QUANTITY (CFM) A018 A024 W024 A030 W030 A036 T036 W036 A042 T042 A048 T048 W048 E042 A060 T060 X060 400 500 600 700 800 WET 0.08 0.12 0.16 0.22 0.29 DRY 0.07 0.11 0.15 0.20 0.27 600 700 800 900 WET 0.16 0.21 0.26 0.31 DRY 0.14 0.19 0.24 0.29 600 700 800 900 WET 0.15 0.20 0.24 0.30 DRY 0.13 0.18 0.23 0.29 700 800 900 1000 1100 WET 0.17 0.22 0.28 0.33 0.41 DRY 0.16 0.21 0.27 0.32 0.40 700 800 900 1000 1100 WET 0.13 0.16 0.20 0.24 0.27 DRY 0.10 0.14 0.17 0.20 0.24 900 1000 1100 1200 1300 WET 0.18 0.22 0.26 0.30 0.35 DRY 0.15 0.18 0.22 0.26 0.30 900 1000 1100 1200 1300 WET 0.15 0.18 0.21 0.25 0.28 DRY 0.12 0.14 0.16 0.19 0.23 1000 1100 1200 1300 1400 WET 0.18 0.21 0.25 0.28 0.32 DRY 0.14 0.16 0.19 0.23 0.24 1300 1400 1500 1600 WET 0.21 0.24 0.28 0.31 DRY 0.19 0.22 0.25 0.28 1300 1400 1500 1600 1700 WET 0.16 0.17 0.19 0.21 0.23 DRY 0.14 0.16 0.18 0.20 0.22 1200 1300 1400 1500 WET 0.25 0.30 0.34 0.40 DRY 0.23 0.27 0.31 0.35 1600 1700 1800 1900 2000 2100 WET 0.19 0.21 0.23 0.26 0.29 0.33 DRY 0.17 0.19 0.21 0.23 0.25 0.28 1600 1700 1800 1900 2000 2100 WET 0.21 0.23 0.25 0.27 0.29 0.31 DRY 0.16 0.18 0.20 0.22 0.25 0.27 INDOOR COIL PISTONS UNIT FACTORY-INSTALLED INDOOR PISTON SIZE CK5A/CK5BA018 52 CK5A/CK5BA024, W024 59 CK5A/CK5BA030, W030 67 CK5A/CK5BA036, W036, T036 70 CK5A/CK5BA042, T042, E042 78 CK5A/CK5BA048, T048, W048 84 CK5A/CK5BA060, T060, X060 90 7

Carrier Corporation Syracuse, New York 13221 8-03 Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Book 1 4 Page 8 Catalog No. 02CK-5A5 Printed in U.S.A. PC 101 Form CK5A-5PD Tab 3d 2d Replaces: CK5A-4PD