Pipetting Small Volumes

Similar documents
Lab Skills Practice: Pipetting Small Volumes. B3 Summer Science Camp at Olympic High School 2016

UNCC Biotechnology and Bioinformatics Camp. Dr. Jennifer Weller Summer 2010

Lab 1. Instrumentation Familiarity: Using Micropipetters and Serological Pipettes

MOLEBIO LAB #1: Microquantity Measurement

Pipetting and Determining Protein Concentration

Laboratory #2 Pipetting Technique and Micropipette Calibration Skills=40 pts

For accurate measurements and to prevent damage to the micropipets, follow these important guidelines:

Biochemistry Laboratory I CHEM 4401 Pipetting & Scales

For accurate measurements and to prevent damage to the micropipets, follow these important guidelines:

Improving Pipetting Techniques

Pipettor. User Manual

Adjust the Volume Display

Chapter 2. Pipetting techniques. Guide to Pipetting

Improve pipetting results in pharmaceutical formulation by using MICROMAN E

Using a micropipette to transfer exact liquid measurements in scientific experiments By: Nicole Hume

For accurate measurements and to prevent damage to the micropipets, follow these important guidelines:

Inquiry Module 1: Checking the calibration of a micropipette

RayPette Plus Autoclavable Pipette. User Manual

The pipettes cover a volume range from 0.1µl to 10ml.

II. MATERIALS REQUIRED FOR PERFORMANCE TESTING

How to Measure R7.1. Reference. I. Linear dimensions

A N F G J I C D D L A B C D E F

VWR UHP j :01 Page 1. ENGLISH 1 22 DEUTSCH FRANÇAIS ESPAπOL ITALIANO

SOP-111 Pipetting Small Volumes

25/04/56. LTC Carmen A. Bell Chief, Laboratory Operations USAMC-AFRIMS

MULTICHANNEL. Labnet International, Inc.

Prepared By: Lisa McAvoy 30/Nov/17 dd/mmm/yy. Approved By: Veronica Harris-McAllister 30/Nov/17 dd/mmm/yy

Real World Metric System

User s Manual. Autoclavable & UV r e s i s t a n t. Digital micro pipette for liquid handling. In Vitro Medical Diagnostic Devices (98/79/EC)

Tips for Proper Pipette handling and Maintenance. D. Muruganand, Ph.D ILQA - Bangalore, Feb 2014

Standard Operating Procedure. Air Displacement Pipette Calibration

Gel Loading Practice MiniLab

Calibration of Volumetric Glassware

User s Manual. Autoclavable & UV resistant. Multi-channel digital micro pipette. In Vitro Medical Diagnostic Devices (98/79/EC)

CHM250 Calibration and Measurement Lab. Balance Calibration

Fisherbrand. Finnpipette INSTRUCTIONS FOR USE PARK LANE Pittsburgh PA

Technical Procedure for General Laboratory Equipment

A N B P F G J I C D D L A B C D E F

Operating Instructions. Rainin Classic Manual Pipette

VOLUMETRIC TECHNIQUES

THE UNIVERSITY OF NEWCASTLE - DISCIPLINE OF MEDICAL BIOCHEMISTRY

User s Manual. Digital micro pipette for liquid handling CERTIFIED ISO9001

Transferpette. Testing Instructions (SOP) 1. Introduction. October 1998

Transferpette -8/-12

INTRODUCTION TO THE SPECTROPHOTOMETER AND PIPETTING SKILLS

Lab Equipment ANALYTICAL BALANCE

Experiment #2. Density and Measurements

Transferpette. Testing Instructions (SOP) 1. Introduction. May 2009

BASIC LABORATORY TECHNIQUES (Revised )

APPENDIX A CORRECT USE OF DIGITAL PIPETTES

BASIC LABORATORY TECHNIQUES (Revised )

MICROMAN ENGLISH. Other languages can be consulted and downloaded on our website,

The use of the analytical balance, and the buret.

User s Manual. Autoclavable & UV resistant Nichipet EX II. Digital micro pipette for liquid handling. In Vitro Medical Diagnostic Devices (98/79/EC)

CH2250: Techniques in Laboratory Chemistry. Outline Measuring Mass Measuring Volume Significant figures. Mass Measurement

Experiment 1 Use of Micropipettes: measuring volume accurately

Other languages available on our website:

Nichipet EX Plus II. User s Manual. Autoclavable & UV resistant. Digital micro pipette for liquid handling

Hands-On Experiment Density and Measurement

ali-q TM Gravimetric Verification Procedure

PIPETMAN F ENGLISH. Other languages available on our website:

Measuring Mass and Volume

Varipette Operating manual

Read over Techniques #2, 4, 5, 6, and 9 in the Demonstrations of Nine Practical Lab Techniques booklet.

A N B P G J I C D L D E

Any laboratory is equipped with specific tools, equipment,

D. De La Matter 2004 Swimming Pool Chemistry STUDENT ACTIVITIES:

VITLAB micropipette. Standard Operating Procedure (SOP)

VIAFLO 96. Electronic 96 Channel Hand Held Pipettor

CHEM 321 Experiment 1

LABORATORY EXERCISE I METRIC SYSTEM OF MEASUREMENT

Predicted Dispense Volume vs. Gravimetric Measurement for the MICROLAB 600. November 2010

VWR HIGH PERFORMANCE PIPETTOR

CHM Introductory Laboratory Experiment (r17sd) 1/13

Chapter Pipette service & maintenance. Pipette specifications according to ISO Repair in the lab or return for service?

How to Use: 1. Hold the pipette like you are going to shake hands with it.

Purpose. Introduction

Accuracy and Precision

LABORATORY TECHNIQUES. Pouring Liquids

SoCal BioMed, LLC 4695 MacArthur Court, 11th Floor Newport Beach, CA Phone: +1 (424) Fax: +1 (323)

The pipette of Choice for Problem Liquids!

Experiment 1 Basic Laboratory Operations

Register your instrument! Eppendorf Xplorer / Eppendorf Xplorer plus. Adjustment

Userts Manual. Digital micro pipette for liquid handling. In Vitro Medical Diagnostic Devices (98/79/EC) Annex III self-declared ISO 8655 STANDARD

Measurements. Metric System

EXPERIMENT 1 BASIC LABORATORY TECHNIQUES AND TREATMENT OF DATA MEASUREMENTS

THE UNIVERSITY OF NEWCASTLE - DISCIPLINE OF MEDICAL BIOCHEMISTRY

Eliminating Sources of Pipetting Error in the Forensic Laboratory David M. Epstein Director of Scientific Operations. Abstract.

QAM-I-117 Volumetric Equipment Calibration Verification

CHM 100 / Introductory Laboratory Experiment (r10) 1/11

The Ideal Gas Constant

Recording Significant Figures

PREPARING GAS SAMPLES IN LARGE PLASTIC SYRINGES

VITLAB Volumetric instruments

SoftGrip Single Channel Pipettes User Manual New Photo To Come

Before you start sampling, be sure to read

Determination of Sodium using Atomic Emission

00 Experiment: Basic Lab Techniques, Compliance of GLP and Calibration of Glassware

CHM 317H1S Winter Section P Procedures and Tables

Eppendorf Research fix variable multi Instruction Manual Bedienungsanleitung Mode d emploi Instruzioni d impiego Manual de Instrucciones

Transcription:

Pipetting Small Volumes

Introduction Serological and micropipettes are used to accurately transfer small liquid volumes (micro-liter to milli-liter) accurately and precisely. Continuously adjustable Can be set to any transfer volume within its range, which is from 10% of the marked volume up to but not beyond the marked volume. Glass and plastic serological pipettes are used for volumes from 1ml 25ml, using a pipette pump.

Serological pipettes Weller UNCC

The MicroPipette Make sure you know how to Select the proper micropipetter to transfer a specified volume of sample Set a specified volume on the pipette volume indicator using the volume adjustment knob Read the volume setting in correct units Select the correct tips and properly seat them Demonstrate the correct technique to accurately transfer a sample of a stock solution to another container (usually a microfuge tube). Properly eject the tip into a waste container.

Parts of the Pipette Pipette tips

Operating the Micropipette Step 1: Select the correct pipetter and set the volume Pipettors 3 Volumes: Volume Adjustment Knob: Digital Volume Indicator:

Operating the Micropipette Step 2: Read the volume How to Read the Volume Indicator: (a): P-20 Model 6.86 m l = 0.00686 or 6.86 x 10-3 ml (b): P-200 Model 132.4 m l = 0.1324 or 1.324 x 10-1 ml (c): P-1000 Model 262 m l= 0.262 or 2.62 x 10-1 ml

Operating the Micropipette Step 3: Attach the disposable tip Tip boxes are labeled for the range of barrel they accommodate (there are some manufacturer-specific types so check if you are mixing and matching). Center the end of the barrel in the tip and tap straight down, gently, twice. Attaching the disposable tip Some tips include a filter barrier mostly used for PCR reactions.

Operating the Micropipette Step 4: Depress the Plunger to the First Stop Depress the plunger first: don t put the tip in the liquid and then depress the plunger (the pressure is different). Step 5: Immerse Tip in Sample The tip must be below the surface of the liquid throughout the process of pulling up the liquid. Ideally the pipette is held vertically. To aspirate the sample into the tip, allow the pushbutton to return slowly and smoothly to the fully extended starting position. Step 6: Pause NEVER LET THE PLUNGER SNAP UP! Leave the tip in the solution for 1-2 sec (longer for a viscous solution), then slowly withdraw.

Operating the Micropipette Step 6: Withdraw the tip from the solution Withdraw the pipet from the receiving vessel carefully, touching or sliding the tip along the wall of the vessel.

Operating the Micropipette Remove the tip from the sample liquid. There should not be liquid on the outside of the tip if you have used it correctly generally we do NOT touch the tip with anything. Some reagent containers may not allow ideal practice in that case wipe away any droplets on the outside of the tip with a lint-free tissue, such as KIMWIPES. Don t touch the tip opening or you will wick away some of the sample. Note on the left that the volume is not correct (air at bottom). Step 7: Withdraw the Tip Proper Droplet Removal WRONG Droplet Removal Note you should be wearing gloves no bare hands!

Operating the Micropipette Step 8: Dispensing the solution to a tube (a) Start Dispensing (b) 1st Stop = Dispense (c) 2nd Stop = Expel a) Touch the tip end to the bottom or side wall of the receiving vessel b) Depress the plunger slowly to the FIRST STOP. c) Pause for at least one second, longer for larger volumes or viscous liquids. d) Press the plunger to the SECOND STOP (the second point, of greater resistance, at the bottom of the stroke) to expel any residual liquid in the tip an air bubble should force out the last drop of liquid.

Operating the Micropipette Step 9: Use the ejector button to eject the tip into a waste container (use a Biohazard can as required).

First Lab: Equipment and Supplies A set of micropipettes and tips Several capped solution containers (water, then glycerol why?) Parafilm squares A Mettler balance

Checking the volume If you know the density of the liquid you are pipetting, and you have a calibrated mass balance, you can pipette a specified volume into a pre-weighed container and determine the mass of the volume Pre-weighing the container is also called Taring it. Why use water to check you pipetting? At 20C, H 2 O has density as shown: 1ml = 0.9985 gm 1ul = 0.00099 gm = 0. 99ug A very close approximation of ug to ul Weller UNCC

Using the Balance Make sure the balance has sufficient sensitivity for the volume you want to measure. Air currents can change the reading on a very sensitive balance. Make sure you know where the Tare (Zero) control is.

Using Parafilm or weigh boats Aqueous solutions bead up on Parafilm you can leave the backing paper on, but pipette solution onto the waxy side not the paper side. After weighing the volume, blot it up with a Kimwipe, re-tare and repeat the pipetting.

Accuracy and Precision Accuracy means the closeness with which the dispensed volume approximates the volume set on the pipette The level of accuracy is specified as mean error, the average deviation of replicate measurements from what is expected from the volume you set. Precision is the "scatter" or variance of individual measurements obtained from the same volume setting. Precision can also be expressed as standard deviation (variance divided by the mean).

Accuracy and Precision (Continued) Device capabilities: relative accuracies are generally about 1% or less for micropipetters within range These micropipettors have recently been calibrated. Precision error is less than 0.5 % except when transferring the smallest recommended volume for a given pipette model Using the pipettes to transfer volumes which are below the recommended range will introduce larger errors

Lab Practice with Pipettes Practice setting a few volumes Practice reading the digits of set volumes Practice seating the tip, drawing up and dispensing samples of water and of a glycerol solution (glycerol is denser and more viscous). Get the "feel" of the 1 st (set volume to pull up ) and 2 nd (blow-out for delivery) stops Practice using the pipette and record how well measurements match settings (indirectly, your skill).