EPSILON. User Manual. EP-5KG (5000g x 1g) Copyright 2011 American Weigh Scales, Inc. All rights reserved. Rev. 1.0

Similar documents
MS-500. User Manual. MS-500 (500g x 0.1g) Copyright 2010 Fast Weigh Scales All rights reserved. Rev. 2.0

BCM-Series. User Manual. American Weigh Scales. BCM-100 (100g x 0.01g) BCM-650 (650g x 0.1g)

AXIS. User Manual. American Weigh Scales. AXIS-100 (100g x 0.01g) AXIS-650 (650g x 0.01g)

CÜBE. User Manual. American Weigh Scales. CUBE-100 (100g x 0.01g) CUBE-650 (650g x 0.1g)

American Weigh Scales, Inc. BLADE Series D i g i t a l P o c k e t S c a l e BLADE-550. User Manual BLADE-400 BLADE-1000

American Weigh Scales, Inc. LB User Manual

Operating Manual Body fat balance

All Purpose AP-Series Operation Manual

YAMATO CORPORATION 1775 S. Murray Blvd. Colorado Springs, CO USA Tel (719) Fax (719)

Troubleshooting Guide: 640 Pediatric Exam Table with Midmark Scale

StockWeigh 500 D3632 US-B

TABLE OF CONTENTS INTRODUCTION 3 SAFETY PRECAUTIONS 3 PACKAGE CONTENTS 4 DEVICE OVERVIEW 4 BUTTON OPERATION SUMMARY 5 BASIC OPERATION 6

SPS-5. Rate Computing Scale. Operation Manual

SAUTER FK Version /2016 GB

OEM Manual MODEL 2305 ECONOMICAL DIGITAL SINGLE CYLINDER SCALE

SPECIFICATIONS APCEPH1

OEM Manual. MODEL ½ Digit DRUM SCALE

Altimeter and Compass Watch Instruction Manual

DT 630 ALTIMETER, BAROMETER AND COMPASS WATCH OPERATING INSTRUSTIONS

ANALYTICAL BALANCE OPERATING MANUAL. U.S. Solid USS-DBS Models All Rights Reserved Page 1 USS-DBS MODELS

FOOD INTAKE MONITOR. Hardware and Software User s Manual DOC-047 Rev 3.0. Copyright 2009 All Rights Reserved

Reflow Oven HHL3000 INSTRUCTION MANUAL POHUA - jedyny autoryzowany przedstawiciel w Polsce

KERN EG/EW Version /02

CHM Introductory Laboratory Experiment (r17sd) 1/13

Sensoric 4-20 ma Transmitter Board Operation Manual

Gilson Aqua-Check Moisture Tester MA-26X

ACCUSTRIDE ACCUSTRIDEFM. Digital Clip-on Pedometer WC153. Digital Clip-on Pedometer WC154 ENGLISH

Manual Weighingblock VB2 series and Uniscale

STANDARD OPERATING PROCEDURE

BASIC LABORATORY TECHNIQUES (Revised )

CHM 100 / Introductory Laboratory Experiment (r10) 1/11

NOVALYNX CORPORATION MODEL RAIN GAUGE CALIBRATOR INSTRUCTION MANUAL

Application Notes. SLP85xD Load Cells

PTG100 Precision Test Gauge

EC214 EC215 - EC215R Bench Conductivity Meters

COMBAT SWIM BOARD. RJE International, Inc. TAC-300 Revision C. RJE International August 3, TAC-300 Revision C

Quick Installation Guide Doc nr.: C Date:

Approach. S3 Owner s Manual. May _0B Printed in Taiwan

1. Features CONTENTS. English

KERN CM Version /2004

II. MATERIALS REQUIRED FOR PERFORMANCE TESTING

Module No GETTING ACQUAINTED GENERAL GUIDE TIMEKEEPING

USER S MANUAL. PD1-Pedometer Watch. ENGLISH l 1

Precision Liquid Settlement Array Manual

IMPORTANT SAFETY INSTRUCTIONS

200 PSI COMPRESSORS - MODEL NUMBERS

100C Air Compressor Kit

ORB-400 BUBBLE/HAZE MACHINE. Item ref: UK User Manual

Measurements. Metric System

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

User Guide. 2 Player Basketball Game

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

This multi-functional device allows the determination of up to six quality parameters with only one measurement:

Adam Equipment. DENSITY DETERMINATION KIT for AFP, AAA and AAA/LE SERIES BALANCES OPERATOR S MANUAL

Any laboratory is equipped with specific tools, equipment,

DO NOT RETURN IT TO THE STORE!

Elcometer ISO Groove Depth Checker. Operating Instructions

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

DIGITAL AUTOMATIC TYRE INFLATOR

444C DUAL PERFORMANCE VALUE PACK

Operating Instructions Part No

Instruction Manual HI Portable Waterproof Dissolved Oxygen Meter.

HI 2314 HI 2315 HI 23151

9A5N Solid State CW Paddle

DTG - LCD Digital Temperature Gauge USER MANUAL

BOEING AIRCRAFT WEIGH WORKSHEET

INSTRUCTION MANUAL MANUAL INFLATION BLOOD PRESSURE MONITOR

ActiveYield. Operation and Adjustment

BASIC LABORATORY TECHNIQUES (Revised )

Limited quantities of compressed gases.

Requirements and Methods for Calibration of Equipment in Clinical Laboratories. NK Chan (HKRCBTS) 24 August 2007

MODEL 100 NITROGEN INFLATION CART

Nuclear Associates

Adam Equipment. DENSITY DETERMINATION KIT for AAA, ADA and ADP SERIES BALANCES OPERATOR S MANUAL

400H HARDMOUNT AIR COMPRESSOR KIT PART NO H HARDMOUNT AIR COMPRESSOR KIT PART NO

User Manual GRI- 1500Li

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

Lab 1. Instrumentation Familiarity: Using Micropipetters and Serological Pipettes

INTRODUCTION TO NETWORK WIND 3 MOUNTING THE UNIT 14 SELECTING THE DISPLAY MODE 5 ABBREVIATIONS AND DEFINITIONS 17

Operating Instructions Part No

Ti-Pure TITANIUM DIOXIDE DETERMINATION OF OIL ABSORPTION (OA) METHOD: T WP

P7911C PressureTrol Controller

INSTRUCTION MANUAL. Automatic Blood Pressure Monitor with Fit Cuff. =Fit Cuff=!"#$% IA1B. Model

OPERATOR S MANUAL Ar-Gone Weld Gas Analyzer

Misaligned Folds Paper Feed Problems Double Feeds Won t Feed FLYER Won t Run iii

Qi Litre Ultrasonic Cleaner

SomnoSuite FAQ. Setup. Calibration 4. What are the calibration requirements for the SomnoSuite? Settings

Pneumator. Testo Industrial Services More assurance, better service. Pressure calibrator and measuring instrument.

TQC Bresle Chloride test 2008

RAM 4021 Operation Manual

COMBAT SWIM BOARD. RJE International, Inc. RJE International Feb 1, TAC-300 Revision 6

FAULT CODE TROUBLESHOOTING INDEX

Infrared Thermometer Instruction manual

Pedometer with PC download. Model: FB322 OVERVIEW FRONT VIEW INDEX

DOscan10 Pocket Dissolved Oxygen Tester Instruction Manual

GNX 20/21. Owner s Manual

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

400C & 450C DUAL PERFORMANCE VALUE PACKS

MODEL NUMBER: P-A AUTOMATIC PORTABLE COMPRESSOR

Transcription:

User Manual EP-5KG (5000g x 1g) Copyright 2011 American Weigh Scales, Inc. All rights reserved. Rev. 1.0

Thank you for purchasing the American Weigh EPSILON digital kitchen scale. Please read all operating instructions carefully before use. Scales are precision measuring devices and should always be handled with proper care. To ensure years of reliable service, keep these simple tips in mind: Do not exceed the scale s maximum capacity. Overloading your scale can permanently damage it! Avoid exposure to extreme heat or cold. Scales perform best at normal room temperature. If temperatures have changed dramatically, calibration and adjustment may be necessary. Allow your scale to warm up for 30-60 seconds before performing calibration and adjustment(if available). Store your scale in a clean, dry location. Dust, dirt, and moisture can accumulate on the weighing sensors and electronics causing inaccuracy or malfunction. Avoid using your scale in close proximity to strong radio wave emitting devices such as computers, cash registers, and cordless phones. Always weigh on a flat and level surface, free from vibrations and drafts. The corner of a room is usually the most stable. Gently apply all items to be weighed. Do not drop items onto the weighing platform. Avoid dropping your scale. The warranty does not cover damage due to rough treatment or overload. Check the batteries first if you are having any trouble with your scale. This simple step can remedy most scale issues. Do not disassemble your scale. This product contains no user serviceable parts.

min I. Part List 1. Scale 2. AAA Batteries (x3) II. Key Description UNIT / Minute Key unit Max: 5000g d: 1g g sec Seconds Key ON/OFF Tare Key Tare Timer Timer Key III. Battery Installation 1. Before using the scale for the first time, check the battery compartment and remove any plastic insulation strips or packaging that may be in place to prevent battery drainage during shipping/storage. 2. If you are replacing the batteries, make sure the positive and negative contacts are properly aligned.

IV. Operation 1. Place the scale on a flat, level surface and tap the / Tare key to turn the scale on. 2. Once the start-up process completes and the scale goes to zero you are ready to weigh. 3. Place the quantity to be weighed onto the weighing platform. 4. Wait a couple seconds for the display to stabilize before taking a weight reading. V. Changing the Unit of Measure 1. Press the min/unit key to change the scales displayed unit of measure. 2. If the scale is turned off then back on, it will default to the last unit used. EP-5KG Units: g (gram) oz (ounce) fl.oz (fluid ounce) lb:oz (pound:ounce) ml (milliliter) VI. Using the Tare Feature You can use this scale s tare feature to subtract the weight of an empty container or vessel for net weight determination. NOTE: The weight of the container will subtract from the available capacity. 1. With the scale ON, place the empty container or vessel on the weighing platform. 2. Press the / Tare key once. The display will then reset to zero. If the container is removed, it s weight will be displayed as a negative number. 3. You may now fill the container with the quantity to be weighed. The display will show the net weight of the contents. 4. To return to normal weight display (gross weight),

VII. VIII. remove any items from the weighing platform and press the / Tare key again to re-zero the scale. Timer Function 1. Press the Timer key to enter kitchen timer mode. 2. To set the timer: a. To change the minutes by 1 minute at a time, tap the min/unit key. b. To change the minutes by 10 minutes at a time, press and hold the min/unit key. c. To change the seconds by 1 minute at a time, tap the min/unit key. d. To change the seconds by 10 minutes at a time, press and hold the min/unit key. 3. Once the timer is set, press the Timer key to start the countdown. 4. You can press the / Tare key during the countdown to use the scale at any point. The countdown will continue internally. Press the Timer key to display the countdown again. 5. An audible alarm will notify you when the countdown is completed. To stop the alarm press the Timer key. Troubleshooting Problem: Scale will not turn on Solution: Check the batteries Problem: Displayed weight fluctuates randomly

Solution: Make sure your workspace is stable and free of any air currents or vibration IX. Error Codes 1. OUTZ - Zero range has shifted. Perform calibration adjustment. If the problem persists, the load cell may be permanently damaged due to overloading. 2. EEEE - Maximum capacity exceeded. Remove the extra weight to avoid damaging the load cell. 3. UNST - Scale is unstable. Use the scale in a more stable position. X. Specifications EP-5KG Max. Capacity 5000g Readability 1g Power 3 x AAA Dimensions 5.9 x 9.0 x 1.1 Platform Dimensions 5.9 x 9.0 Warranty 10 Year Limited Warranty XI. Capacity/Readability Charts EP-5KG 5000g x 1g 169.1fl.oz x 0.1fl.oz 11lb x 0.1oz 5000ml x 1ml American Weigh Scales, Inc. Norcross, GA 30092, U.S.A Made in China to our exact specifications and quality control.