SC HYDRAULIC ENGINEERING CORPORATION

Similar documents
SC HYDRAULIC ENGINEERING CORPORATION

FLOW CONTROL & AIR PILOT SWITCH VALVES

Air Amplifiers & SYSTEMS

AIR DRIVEN. Gas Boosters & SYSTEMS. Accepting VISA, MasterCard and American Express

Gas Boosters & Systems

Pressure on Demand. Air Pressure Amplifiers

Air Operated Hydraulic Pumping Systems to 50,000 psi

Standard Operating and Maintenance Instructions for Pumping System Model PS-90

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

Plant, components and devices for very high and high pressures (7000 bar and over)

The Compact, Portable, Efficient and Economical Solution to boost Shop Compressed Air Pressure by 2 or 3 times

Standard Operating and Maintenance Instructions for Pumping System Model PS-150

Hi-Force Limited Prospect Way Daventry Northants NN11 8PL United Kingdom Tel: +44(0) : Fax: +44(0) : Website:

RK LEL Sample Draw Aspirator Adapter Operator s Manual

RK-IR Sample Draw Aspirator Adapter Operator s Manual

INSTRUCTIONS FOR MODELS SG3897 AND SG3898 CROSS PURGE ASSEMBLIES

SIX R (P ) AND SEVEN R (P ) POSITION CYLINDERS Service Information

CSA Sample Draw Aspirator Adapter Operator s Manual

Interface Devices, Inc. Hydraulic Mini Mule

Storage Systems and Accessories

HYDRAULICS INTERNATIONAL, INC.

hydro-pac, inc. Low-Pressure Gas Compressors 1500 to 6000 PSI

TOP VALVE. Pat. #5,857,486 & 5,944,050. Mid-Range Pressure PSIG Back Pressure and Pressure Relief Valves. Instruction Manual

92831 TEL: (714) FAX:

air driven Standard air gas liquid for high pressure: contents Chatsworth, California, USA

WATER HEATER THERMAL EXPANSION TANKS Owner s Manual. Safety Instructions Installation Maintenance Warranty. Models: 2-5 Gallon Capacity

Installation Instructions JATCO Environmental Protection Tank Model J-7000

Unit 24: Applications of Pneumatics and Hydraulics

AIR DRIVEN DRIVEN GAS BOOSTERS

AIR DRIVEN LIQUID PUMPS AIR DRIVEN AIR AMPLIFIERS AIR DRIVEN GAS BOOSTERS HIGH PRESSURE VALVES, FITTINGS AND TUBING TEST AND CALIBRATION EQUIPMENT

Installation Instructions JATCO Environmental Protection Tank Model J-5000CX

MEDICAL EQUIPMENT CATALOG

WORKHOLDING APPLICATION BOOKLET

GALISO SOAP OPTION FOR PCT-ADW-D

BACK PRESSURE / SUSTAINING

Cash Valve. Type G-4. Pilot Operated Pressure Reducing Regulator for Steam, Air and Gases. Flow Control

ACCU-MIX 1200 / / 26270

Index Table. Model 794. Installation, Operating and Maintenance Instructions

Compact Triple Cabinet Outlet Station Model B Installation and Operating Instructions

P5523. Users Manual. Liquid to Gas Separator. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

EQUIPMENT Operation Manual. Loctite Stainless Steel Poppet Valve Part Number

GB-75 and GB-152 Gas Booster With Control Kit Operation and Maintenance Manual

INSTRUCTIONS FOR MODEL SSC LOW DELIVERY PRESSURE GAS REGULATORS

TITAN FLOW CONTROL, INC.

KJ1000 Operating Instructions & Parts Manual NSN

92831 TEL: (714) FAX:

Compact Triple Cabinet Outlet Station Model Installation and Operating Instructions

HAYWARD FLOW CONTROL Series PBV Back Pressure Valve and Series RPV Pressure Relief Valve INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS

TOP VALVE. Pat. #5,857,486 & 5,944,050. High Temperature: max. 300 F (149 C) Back Pressure And Pressure Relief Valves. Instruction Manual

GB-H M and GB-H M Gas Booster Packages Operation and Maintenance Manual

BS Series Basket Strainer

INDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES

623 Series Dome Load Regulators

CVI Valve Line. Exceeds the industry s highest standards for reliability and performance

BACK PRESSURE / SUSTAINING

Operation Manual Piston Sensed Gas Pressure Regulators

Operation & Service Manual

OPERATING INSTRUCTIONS Pressure Control System PCS-20 through PCS-100

GBK-50M / GBK-110M. Booster. Instructions. Introduction. How to Contact Fluke Calibration

Operation Manual. Diaphragm Sensed Gas Pressure Regulators

OPERATION MANUAL NTF-15

CF-SERIES HIGH FLOW REGULATORS

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

CHAPTER 3 : AIR COMPRESSOR

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP

KJ4000 Operating Instructions & Parts Manual NSN

OPERATION MANUAL NTF-60 Plus

453 Series Steam Heated Vaporizing Regulator

USER GUIDE. Fog Generator. ATMOSPHERE APS TM Series Haze Generator. MAX APS TM Series. No: , Revision A/a

Best Practices Pneumatics Machine & Design. Written by Richard F. Bullers, CFPPS as published in Fluid Power Journal, July/August 2016

Your local gas generation partner. Precision series Modular gas generation solution for GC.

Cash Valve TYPE G-4 PILOT OPERATED PRESSURE REDUCING REGULATOR FOR STEAM, AIR AND GASES. ISSUED - MARCH 2001 CAVMC-0512-US-0208 ISO 9001 Certified

EQUIPMENT OPERATION MANUAL. Loctite Dispense Valve Manual

1200 Series Pressure Regulators

Inert Air (N2) Systems Manual

Series 8500 Expansion Compensators. Catalog 674H

HighVac Pumps. High Vacuum Venturi Pumps. Modular Venturi Vacuum Pumps with Solenoid-Operated Vacuum and Blow-Off

J Air and Water Kit Instructions Part# 02584

Model Series 62 Constant Differential Relay

Marschalk Model # 94000

USER GUIDE. Fog Generator. ATMOSPHERE APS Series Haze Generator. MAX APS Series. No: , Revision A/d

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

COMPRESSED AIR DISTRIBUTION SYSTEMS

FILTER BYPASS CONTROL

Model ASSEMBLY and OPERATING INSTRUCTIONS

Sullair Air Systems. *Assessment of the market for compressed air efficiency services. Technical report, U.S. Department of Energy, June 2001

EQUIPMENT Operation Manual

Model No Product Name Handpiece Only Complete System

INSTALLATION & MAINTENANCE INSTRUCTIONS DESCRIPTION SPECIFICATIONS. CE (EMC) Compliant

Fundamentals of Compressed Air Systems. Pre-Workshop Assignment

Pressure and/or Temperature Pilot Operated Steam Regulators Series 2000

GAS SUPPLY DESIGN GUIDE

L 100. Bubble-Tube Level System. Installation, Operation and Maintenance Instructions

Trifecta Systems. Cryogenic Equipment for High Performance Gas Supply. Trifecta Product Catalog

DB 61 Dolphin TMV3 Integrated Thermostatic Mixing Valve

INSTRUCTIONS FOR MODELS UPH & UPHS HIGH FLOW, HIGH PURITY GAS REGULATORS

V43 Pressure Actuated Water Regulating Valve

4 and 8 Station PDS Control Installation & Operators Manual

42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only)

GasTrak Pro TM Delivery/Control Systems

Transcription:

Designers and Manufacturers of Hydraulic and Pneumatic Equipment SC HYDRAULIC ENGINEERING CORPORATION 113 Columbia Street - Brea, California 92821 - USA Phone (714) 257-48 - Fax (714) 257-481 B AIR OPERATED GAS BOOSTERS & SYSTEMS O O S T E R

A High Pressure History An innovator and pioneer in the field of hydraulic engineering, SC Hydraulic has been manufacturing air-driven liquid pumps for more than a half of a century. Founded in 1953 by Bob Vedder and Willie Mohler, the company started with only a few core products. Basically air-driven liquid pumps. Today, SC Hydraulic s product line has expanded to include an extensive collection of air and gas boosters, power units, systems and selected highpressure valves. The product line remained stable through the 198s seeing successful operation in an everincreasing number of installations and applications, while sales grew through an expansion of distribution. Under the leadership of Bob Vedder's daughter, Donna Perez, SC Hydraulic operates a state-of-the -art 65, square-foot facility in Brea, California, and is well prepared for future growth and innovation. Where Hydraulic Force Meets Custom Engineering With products capable of achieving pressures exceeding 7, psig, SC Hydraulic Engineering Corp. is a force to be reckoned with in the field of hydraulic engineering. SC Hydraulic manufactures a vast array of air -operated hydraulic pumps and boosters for a variety of industries. In addition to our current line of hydraulic products, we can work with you to custom design products to fit the exact specifications of your applications. An international leader in hydraulic engineering, SC Hydraulic is staffed with educated and certified engineers. They are continually developing new products which are in sync with newly emerging applications, both in the United States and abroad. For Fluid Power In a 65, square foot facility, SC Hydraulic is capable of setting the industry s highest standards while maintaining the best delivery times Contact SC Hydraulic today, to find out more about our capabilities or for a technical data sheet. 3 SC Hydraulic Engineering 113 Columbia St. Brea, CA 92821 Tel 714-257-48 Fax 714-257-481 www.schydraulic.com

AIR DRIVEN GAS BOOSTERS SC air driven gas boosters are self-contained units, using a cycling spool and pilot valve to provide automatic reciprocating action when air or gas is supplied to the air drive inlet. The drive consists of a large piston and valve assembly directly connected to a hydrocarbon-free pumping piston with self lubricating seals cycling in a stainless barrel that has an integral check valve. The working surface area of the drive piston exceeds the working surface area of the pump piston, thereby providing the pressure BOOST. This is accomplished by using relatively low pressure air or SC gas boosters are suitable for other applications such as bottle filling from nitrogen generators and dewars, hydrogas suspension systems, automotive air gas storage systems, aircraft slide chute gas storage; sulfur hexafluoride (SF6) transfer for arc suppression and insulation of circuit breakers commonly found in the utility industry, gas injection molding, etc. In addition to our complete line of gas boosters, SC also fabricates custom gas booster systems for individual applications. These units are manufactured to customer specifications and can include filters, gas to the drive inlet. The air drive section is prelubricated (thus eliminating the need for an air line lubricator), easy to install, and can be mounted in any position eliminating additional floor space. No electrical connections are required. SC gas boosters are typically used to boost low pressure gas/air to a higher pressure required at the process or test station. Most industrial gases (nitrogen, helium, hydrogen, argon, etc.) are commonly delivered under pressure in steel cylinders. If gas is to be used at low pressures, e.g., welding, the pressurized supply is easily piped and controlled to the point of use with simple valving. However, if the end use requires the gas under pressure, the supply cylinder pressure cannot be utilized after it has fallen to the level of the end use pressure. Therefore, the gas remaining will be wasted unless it is boosted. If the application requires a pressure greater than the common supply cylinder pressure, a gas booster must be used. Depending on the unit selected, you can boost gas pressure from 25 psi and up to 25, psi. gauges, pilot switches, panel controls, tubular frames, etc. Contact your distributor or our sales department for more information. To assist in selecting the best gas booster for your application SC offers a free service for sizing units. Just fill out the data worksheet located on page 7 and fax back to us at 714-257-481 or e-mail the information to service@schydraulic.com. Please make sure to fill out the form completely as all the information is important. 5 SC Hydraulic Engineering 113 Columbia St. Brea, CA 92821 Tel 714-257-48 Fax 714-257-481 www.schydraulic.com

Selecting the Right Booster for Your Application We could fill several pages of formulas, tables, and explanations of how to determine the best, most economical booster for your application. After plowing through all the information, including types of gas, decaying supply versus constant, displacement factors, volumetric efficiencies and compression ratios, just to name a few, you may still wonder if you are making the right choice. Or better yet take a minute to read the glossary of terms below so you know the information we need, then fill out the data worksheet on the next page and fax (714-257-481) or e-mail (service@schydraulic.com) the information to us. We ll have an answer for you within a couple of hours with a selection of boosters, fill times if required, pricing, delivery time, and the name of your nearest distributor. At SC Hydraulic Engineering we have a better way - CALL US! We figure you have better things to do with your time besides doing our job. For the best service in the industry, call SC Hydraulic Engineering. GLOSSARY OF TERMS Pa (Air Drive Pressure) Pressure from air/gas compressor available at the booster to drive the unit. If the pressure fluctuates, the lowest pressure available is used to calculate the output gas pressure. The Pa, and in some selections, along with the supply pressure will determine the maximum stall pressure of the booster. Va (Air Drive Flow) Volume of air/gas measured in SCFM (standard cubic feet per minute) available to drive the unit. The volume of air/ gas determines the speed in which the booster will cycle and therefore the volume delivered from the outlet port. The volume of outlet gas also determines the speed in which a vessel is filled to a static pressure. CPM (Air Drive Speed) Cycles per minute when operating the booster, which is determined by the volume of drive air/gas available. The CPM is highest when starting to fill a vessel and decreases as the output pressure increases until reaching the static or stall pressure. Ps (Gas Supply Pressure) Pressure of the gas from the supply source. If the supply is from a gas generator or very large source, the Ps may be considered constant. If from a smaller source, typically bottles, the Ps will decrease as the supply is used. The decrease in supply will affect the static pressure output (in certain boosters) and the fill time or SCFM of the output. Vs (Gas Supply Volume) Volume of the gas available from the supply source. This is measured not by SCFM but by ACF (actual cubic feet) or water volume of the source. If the supply is from a gas generator or very large source, the Vs may be considered unlimited. The ACF of the supply determines how many fills to a certain static pressure can be made until the source is depleted. Po (Gas Outlet Stall Pressure) Pressure of the gas at the outlet. This can be stated as an output pressure at a certain SCFM or as the static output stall pressure when filling a vessel. Vo (Gas Outlet Flow) The volume of gas delivered at the outlet port measured in SCFM. This can be converted to ACFM if the temperature of the output gas is known using the formula: ACFM = SCFM x 14.696 / (Pa + 14.696) x degrees F. / 53 6 SC Hydraulic Engineering 113 Columbia St. Brea, CA 92821 Tel 714-257-48 Fax 714-257-481 www.schydraulic.com

DESIGNER AND MANUFACTURER OF HYDRAULIC AND PNEUMATIC EQUIPMENT SC HYDRAULIC ENGINEERING CORPORATION 113 Columbia Street, Brea, CA 92821 USA - (714) 257-48 Fax (714) 257-481 DATA WORKSHEET GAS BOOSTER DATE CONTACT NAME CUSTOMER E-MAIL PHONE FAX CITY STATE ZIP STATE UNITS OF MEASURE USED PSI BAR CU FT LITER AIR DRIVE INFORMATION AIR DRIVE SOURCE: AIR PRESSURE MAXIMUM MINIMUM NITROGEN MINIMUM FLOW AVAILABLE TO BOOSTER SCFM GAS SUPPLY INLET TYPE OF GAS MAXIMUM SUPPLY PRESSURE MINIMUM ACTUAL SUPPLY VOLUME ACF OR FLOW RATE SCFM GAS HIGH PRESSURE OUTLET OUTLET PRESSURE REQUIRED TIME REQUESTED TO FILL ACTUAL VESSEL VOLUME TO FILL OR FLOW RATE DIAGRAM OF APPLICATION (optional) 7 SC Hydraulic Engineering 113 Columbia St. Brea, CA 92821 Tel 714-257-48 Fax 714-257-481 www.schydraulic.com

GB SERIES Single Stage-Single Acting Booster The GB series is the most economical of the SC Hydraulic Gas Boosters and is ideal for applications not requiring much volume such as pressure testing small vessels or components. Pressures can be boosted from as low as 5 psig and up to over 11, psig. 18.86" 3/4" NPT DRIVE INLET 7.77" 1.13" 4.75" 3.56".31" 8.99" Model No. Rated Gas Supply Rated Gas Outlet Pressure (Po) Inlet Port (A) Outlet Port (B) Static Outlet Stall Pressure Minimum Inlet Gas Displacement Per Stroke (in3 per cycle) GB-15 GB-3 GB-75 2,25 psig 2,25 psig 1/4" NPT 155 bar 155 bar 1/4" NPT 4,5 psig 4,5 psig 1/4" NPT 31 bar 31 bar 1/4" NPT 6, psig 11,25 psig 9/16"-18 (1) 41 bar 775 bar 9/16"-18 (1) 15 Pa 5 psig (3.5 bar) 7.5 3 Pa 1 psig (7 bar) 3.1 75 Pa 25 psig (17 bar) 1.2 (1) Coned and Threaded High Pressure Connection for ¼ O.D. Tubing. 2. Refer to corresponding gas booster performance curve for operating pressures (see page 9 to 2). 3. Maximum material rated outlet pressures can be reached under special operating conditions. Do not use air drive or/and gas supply pressures that equate to higher outlet pressures than those "maximum material rated outlet pressures" shown on table. Refer to Static Outlet Stall Pressure formula shown on table (for example, for gas booster model GBD-3 the formula is: Static Outlet Stall Pressure = 3*Pa+Ps). 4. Maximum recommended air drive operating pressure: 1-psi. 5. Maximum rated air drive pressure: 15-psi (only for static outlet stall pressure). For assistance in selecting the proper Gas Booster complete and fax the data work sheet or e-mail inquires to service@schydraulic.com 8 SC Hydraulic Engineering 113 Columbia St. Brea, CA 92821 Tel 714-257-48 Fax 714-257-481 www.schydraulic.com

GB SERIES Single Stage-Single Acting Booster Drive (P A )=9 psig Outlet Gas Pressure (P O 1 2 3 4 5 6 7 8 9 GB-15 16 14 12 1 8 6 2 3 4 5 =7 psig 6 GB-15 4 3 2 Legend PA = Drive Pressure PO = Gas Outlet Pressure PS = Gas Inlet Pressure VO = Output Gas Flow 4 1 GB-3 2 2 4 6 8 1 12 14 Outlet Gas Pressure (P O Drive (P A )=9 psig Outlet Gas Pressure (P O 2 4 6 8 1 12 14 16 18 18 16 =16 psig GB-3 14 13 1 12 1 7 8 6 4 4 2 5 1 15 2 25 Outlet Gas Pressure (P O 5 4 3 2 1 NOTE: Performance charts are for reference only. The curves are based on an Air Drive (Pa) of 9 psig and a maximum air consumption of 72-scfm. If the Pa is higher or lower, the Outlet gas pressure (Po) can change significantly. Also, the supply pressures (Ps) shown in the graphs are based on constant pressure being supplied as the pressure is boosted. A supply from cylinders or bottles will affect the pressure outlet (Po) and flow (Vo) as the supply pressure (Ps) is depleted. Contact SC Hydraulic Engineering for detailed performance data on any GB-75 Drive (P A )=9 psig Outlet Gas Pressure (P O 5 1 15 2 25 3 35 4 45 12 =25 psig GB-75 1 2 8 6 4 2 15 1 5 3 25 2 15 1 5 1 2 3 4 5 6 7 Outlet Gas Pressure (P O 9 SC Hydraulic Engineering 113 Columbia St. Brea, CA 92821 Tel 714-257-48 Fax 714-257-481 www.schydraulic.com

GB-D SERIES Single Stage-Single Acting Double Head Booster This series has the same characteristics of the standard GB Series however the double head allows half the input pressure to achieve the same outlet pressure. 25.61" 3/4" NPT DRIVE INLET 7.72" 1.13" 4.75" B THREAD PRESSURE OUTLET A THREAD INLET SUPPLY 3.56" 2.99".31" 8.41" 15.74" Model No. GB-D3 GB-D75 Rated Gas Supply Rated Gas Outlet Pressure (Po) Inlet Port (A) Outlet Port (B) 6, 9, 1/4" NPT 41 bar 62 bar 1/4" NPT Static Outlet Stall Pressure Minimum Inlet Gas Displacement Per Stroke (in3 per cycle) 6 Pa 2 psig (13 bar) 3.1 6, 2, psig 9/16"-18 (1) 15 Pa 1.2 41 bar 1,38 bar 9/16"-18 (1) 25 psig (17 bar) (1) Coned and Threaded High Pressure Connection for ¼ O.D. Tubing. 2. Refer to corresponding gas booster performance curve for operating pressures (see page 9 to 2). 3. Maximum material rated outlet pressures can be reached under special operating conditions. Do not use air drive or/and gas supply pressures that equate to higher outlet pressures than those "maximum material rated outlet pressures" shown on table. Refer to Static Outlet Stall Pressure formula shown on table (for example, for gas booster model GBD-3 the formula is: Static Outlet Stall Pressure = 3*Pa+Ps). 4. Maximum recommended air drive operating pressure: 1-psi. 5. Maximum rated air drive pressure: 15-psi (only for static outlet stall pressure). For assistance in selecting the proper Gas Booster complete and fax the data work sheet or e-mail inquires to service@schydraulic.com 1 SC Hydraulic Engineering 113 Columbia St. Brea, CA 92821 Tel 714-257-48 Fax 714-257-481 www.schydraulic.com

GB-D SERIES Single Stage-Single Acting Double Head Booster Drive (P A )=9 psig Outlet Gas Pressure (P O 5 1 15 2 25 3 35 2 =25 psig GB-D3 5 Legend PA = Drive Pressure PO = Gas Outlet Pressure PS = Gas Inlet Pressure VO = Output Gas Flow GB-D3 15 1 5 5 1 15 2 4 3 2 1 NOTE: Performance charts are for reference only. 1 2 3 4 5 Outlet Gas Pressure (P O The curves are based on an Air Drive (Pa) of 9 psig and a maximum air consumption of 72-scfm. If the Pa is higher or lower, the Outlet gas pressure (Po) can change significantly. Drive (P A )=9 psig Outlet Gas Pressure (P O 2 4 6 8 2 =8 psig GB-D75 65 6 5 Also, the supply pressures (Ps) shown in the graphs are based on constant pressure being supplied as the pressure is boosted. A supply from cylinders or bottles will affect the pressure outlet (Po) and flow (Vo) as the supply pressure (Ps) is depleted. GB-D75 15 1 2 35 5 4 3 2 Contact SC Hydraulic Engineering for detailed performance data on any 5 1 3 6 9 12 Outlet Gas Pressure (P O 11 SC Hydraulic Engineering 113 Columbia St. Brea, CA 92821 Tel 714-257-48 Fax 714-257-481 www.schydraulic.com

GBD-5 Single Stage-Double Acting Booster This gas booster is a modified version of our popular ABD air booster. It is used to boost gas pressures up to 1,5 psig. The booster is able to move large volumes of gas efficiently when lower pressures are suitable. For convenience, the graph illustrates various inlet gas supplies with matching air drive pressures. 9.7" 3/4" NPT DRIVE INLET 7.79" 17.38" 1.1" 8.31" A THREAD INLET SUPPLY B THREAD PRESSURE OUTLET 4.7" 3." 18.97" 7.43".31" Model No. GBD-5 Rated Gas Supply Rated Gas Outlet Pressure (Po) Inlet Port (A) Outlet Port (B) 15 psig 15 1/2" NPT 13 bar 13 bar 1/2" NPT Static Outlet Stall Pressure Minimum Inlet Gas Displacement Per Stroke (in3 per cycle) 4.7 Pa +Ps 25 psig 28.2 Drive P A =9 psig Outlet Gas Pressure (P o Legend PA = Drive Pressure PO = Gas Outlet Pressure PS = Gas Inlet Pressure VO = Output Gas Flow Gas Flow (V o 4 35 3 25 2 15 1 1 2 3 4 5 P a =P s =15 psi GBD-5 125 psi 1 psi 75 psi 1 8 6 4 Gas Flow (V o GBD-5 5 2 1 2 3 4 5 6 7 8 Outlet Gas Pressure (P See NOTE on Page 14 regarding Performance Charts For assistance in selecting the proper Gas Booster complete and fax the data work sheet or e-mail inquires to service@schydraulic.com 12 SC Hydraulic Engineering 113 Columbia St. Brea, CA 92821 Tel 714-257-48 Fax 714-257-481 www.schydraulic.com

GBD SERIES Single Stage-Double Acting Booster This series of boosters doubles the volume of output gas per cycle and is a good choice for moving relatively high volumes at pressures up to 2, psig. Supply pressure is added to the maximum outlet pressure. 3/4" NPT DRIVE INLET 7.77" 25.78" 4.75" 1.13" A THREAD INLET SUPPLY B THREAD PRESSURE OUTLET 3.56" 2.99" 8.99".31" 7.62" 23.38" Model No. Rated Gas Supply Rated Gas Outlet Pressure (Po) Inlet Port (A) Outlet Port (B) Static Outlet Stall Pressure Minimum Inlet Gas Displacement Per Stroke (in3 per cycle) GBD-15 GBD-3 GBD-75 5, psig 5, psig 1/4" NPT 345 bar 345 bar 1/4" NPT 6, psig 9, psig 1/4" NPT 41 bar 62 bar 1/4" NPT 6, psig 2, psig 9/16"-18 (1) 41 bar 1,38 bar 9/16"-18 (1) 15 Pa + Ps 5 psig (3.5 bar) 14.1 3 Pa + Ps 1 psig (7 bar) 6.3 75 Pa + Ps 25 psig (17 bar) 2.4 (1) Coned and Threaded High Pressure Connection for ¼ O.D. Tubing. 2. Refer to corresponding gas booster performance curve for operating pressures (see page 9 to 2). 3. Maximum material rated outlet pressures can be reached under special operating conditions. Do not use air drive or/and gas supply pressures that equate to higher outlet pressures than those "maximum material rated outlet pressures" shown on table. Refer to Static Outlet Stall Pressure formula shown on table (for example, for gas booster model GBD-3 the formula is: Static Outlet Stall Pressure = 3*Pa+Ps). 4. Maximum recommended air drive operating pressure: 1-psi. 5. Maximum rated air drive pressure: 15-psi (only for static outlet stall pressure). For assistance in selecting the proper Gas Booster complete and fax the data work sheet or e-mail inquires to service@schydraulic.com 13 SC Hydraulic Engineering 113 Columbia St. Brea, CA 92821 Tel 714-257-48 Fax 714-257-481 www.schydraulic.com

GBD SERIES Single Stage-Double Acting Booster Legend PA = Drive Pressure PO = Gas Outlet Pressure PS = Gas Inlet Pressure VO = Output Gas Flow 12 1 8 6 4 Drive P A =9 psig Outlet Gas Pressure(P O 5 1 15 2 25 3 9 15 21 =27 psig GBD-15 35 3 25 2 15 1 GBD-15 NOTE: Performance charts are for reference only. The curves are based on an Air Drive (Pa) of 9 psig and a maximum air consumption of 72-scfm. If the Pa is higher or lower, the Outlet gas pressure (Po) can change significantly. Also, the supply pressures (Ps) shown in the graphs are based on constant pressure being supplied as the pressure is boosted. A supply from cylinders or bottles will affect the pressure outlet (Po) and flow (Vo) as the supply pressure (Ps) is depleted. Contact SC Hydraulic Engineering for detailed performance data on any 2 3 5 1 2 3 4 Outlet Gas Pressure (P Drive P A =9 psig Outlet Gas Pressure (P 5 1 15 2 25 3 35 4 7 =295 psi GBD-3 6 225 5 4 155 3 2 85 1 15 1 2 3 4 5 6 Outlet Gas Pressure (P 2 15 1 5 GBD-3 Drive P A =9 psig Outlet Gas Pressure (P 1 2 3 4 5 6 7 8 5 =5 psig GBD-75 4 4 3 3 2 2 1 1 14 12 1 8 6 4 2 GBD-75 2 4 6 8 1 12 Outlet Gas Pressure (P 14 SC Hydraulic Engineering 113 Columbia St. Brea, CA 92821 Tel 714-257-48 Fax 714-257-481 www.schydraulic.com

GBD-D SERIES Double Acting-Double Head Booster This series has the same characteristics of the standard GBD however the double head allows half the input pressure to achieve the same outlet pressure. 3/4" NPT DRIVE INLET 7.72" 32.53" 1.13" 4.75" B THREAD PRESSURE OUTLET A THREAD INLET SUPPLY 3.56" 2.99" 7.62" 15.74".31" 3.13" Model No. Rated Gas Supply Rated Gas Outlet Pressure (Po) Inlet Port (A) Outlet Port (B) Static Outlet Stall Pressure Minimum Inlet Gas Displacement Per Stroke (in3 per cycle) GBD-D15 GBD-D3 GBD-D75 5, psig 5, psig 1/4" NPT 345 bar 345 bar 1/4" NPT 6, psig 9, psig 1/4" NPT 41 bar 62 bar 1/4" NPT 6, psig 25, psig 9/16"-18 (1) 41 bar 1,725 bar 9/16"-18 (1) 3 Pa + Ps 5 psig (3.5 bar) 14.1 6 Pa + Ps 2 psig (14 bar) 6.3 15 Pa + Ps 25 psig (17 bar) 2.4 (1) Coned and Threaded High Pressure Connection for ¼ O.D. Tubing. 2. Refer to corresponding gas booster performance curve for operating pressures (see page 9 to 2). 3. Maximum material rated outlet pressures can be reached under special operating conditions. Do not use air drive or/and gas supply pressures that equate to higher outlet pressures than those "maximum material rated outlet pressures" shown on table. Refer to Static Outlet Stall Pressure formula shown on table (for example, for gas booster model GBD-3 the formula is: Static Outlet Stall Pressure = 3*Pa+Ps). 4. Maximum recommended air drive operating pressure: 1-psi. 5. Maximum rated air drive pressure: 15-psi (only for static outlet stall pressure). For assistance in selecting the proper Gas Booster complete and fax the data work sheet or e-mail inquires to service@schydraulic.com 15 SC Hydraulic Engineering 113 Columbia St. Brea, CA 92821 Tel 714-257-48 Fax 714-257-481 www.schydraulic.com

GBD-D SERIES Double Acting-Double Head Booster Drive P A =9 PSIG Outlet Gas Pressure (P 5 1 15 2 25 3 Legend PA = Drive Pressure PO = Gas Outlet Pressure PS = Gas Inlet Pressure VO = Output Gas Flow Gas Flow (V 8 6 4 2 85 155 225 =4 psig GBD-D15 2 15 1 5 Gas Flow (V GBD-D15 NOTE: Performance charts are for reference only. The curves are based on an Air Drive (Pa) of 9 psig and a maximum air consumption of 72-scfm. If the Pa is higher or lower, the Outlet gas pressure (Po) can change significantly. Also, the supply pressures (Ps) shown in the graphs are based on constant pressure being supplied as the pressure is boosted. A supply from cylinders or bottles will affect the pressure outlet (Po) and flow (Vo) as the supply pressure (Ps) is depleted. Contact SC Hydraulic Engineering for detailed performance data on any Gas Flow (V o 15 1 2 3 4 5 Outlet Gas Pressure (P Drive P A =9 psig Outlet Gas Pressure (P o 5 1 15 2 25 3 35 4 45 5 55 6 7 =4 psig GBD-D3 18 6 5 325 15 12 4 25 3 9 175 2 6 1 1 3 2 4 6 8 Outlet Gas Pressure (P o Drive P A =9 PSIG Outlet Gas Pressure (P o 2 4 6 8 1 12 14 16 8 =12 psig GBD-D75 7 2 Gas Flow (V o GBD-D3 6 1 Gas Flow (V o 5 4 3 2 4 6 8 15 1 5 Gas Flow (V o ) - liter/mon. GBD-D75 1 4 8 12 16 2 24 Outlet Gas Pressure (P o 16 SC Hydraulic Engineering 113 Columbia St. Brea, CA 92821 Tel 714-257-48 Fax 714-257-481 www.schydraulic.com

GBT SERIES Two Stage-Double Acting Booster The GBT series is able to achieve higher compression ratios by combining the first and second stage with an interconnected hydraulic (gas) piston. Maximum outlet pressure is the supply pressure plus the drive area ratio times the area ratio of both hydraulic (gas) pistons. 3/4" NPT DRIVE INLET 7.77" 25.78" 4.75" 1.13" A THREAD INLET SUPPLY 3.56" 2.99" 9.3" 8.99".31" 23.38" B THREAD PRESSURE OUTLET (OPPOSITE SIDE) Model No. Rated Gas Supply Rated Gas Outlet Pressure (Po) Inlet Port (A) Outlet Port (B) Static Outlet Stall Pressure Minimum Inlet Gas Displacement Per Stroke (in3 per cycle) GBT-15/3 GBT-15/75 GBT-3/75 15 Pa to 25 psig (2) 9, psig 1/4" NPT 172 bar 62 bar 1/4" NPT 3.5 Pa to 5 psig (2) 2, psig 1/4 NPT 345 bar 1,38 bar 9/16"-18 (1) 2 Pa to 6 psig (2) 2, psig 1/4 NPT 41 bar 1,38 bar 9/16"-18 (1) 3 Pa +2 Ps 5 psig (3.5 bar) 7.5 75 Pa + 5 Ps 5 psig (3.5 bar) 7.5 75 Pa + 2.5 Ps 1 psig (7 bar) 3.1 (1) Coned and Threaded High Pressure Connection for ¼ O.D. Tubing. (2) GBT Series Gas Boosters: Limit maximum gas supply pressure by formula Ps max = factor * Pa to avoid interstage stall (for example, for gas booster model GBT-15/3 the formula is: Ps max = 15*Pa). 3. Refer to corresponding gas booster performance curve for operating pressures (see page 9 to 2). 4. Maximum material rated outlet pressures can be reached under special operating conditions. Do not use air drive or/and gas supply pressures that equate to higher outlet pressures than those "maximum material rated outlet pressures" shown on table. Refer to Static Outlet Stall Pressure formula shown on table (for example, for gas booster model GBD-3 the formula is: Static Outlet Stall Pressure = 3*Pa+Ps). 5. Maximum recommended air drive operating pressure: 1-psi. 6. Maximum rated air drive pressure: 15-psi (only for static outlet stall pressure). For assistance in selecting the proper Gas Booster complete and fax the data work sheet or e-mail inquires to service@schydraulic.com 17 SC Hydraulic Engineering 113 Columbia St. Brea, CA 92821 Tel 714-257-48 Fax 714-257-481 www.schydraulic.com

GBT SERIES Two Stage-Double Acting Booster Legend PA = Drive Pressure PO = Gas Outlet Pressure PS = Gas Inlet Pressure VO = Output Gas Flow Drive P A =9 psig Outlet Gas Pressure (P 5 1 15 2 25 3 2 16 12 8 4 =9 psig 3 1 5 7 GBT-15/3 5 4 3 2 1 GBT-15/3 NOTE: Performance charts are for reference only. The curves are based on an Air Drive (Pa) of 9 psig and a maximum air consumption of 72-scfm. If the Pa is higher or lower, the Outlet gas pressure (Po) can change significantly. Also, the supply pressures (Ps) shown in the graphs are based on constant pressure being supplied as the pressure is boosted. A supply from cylinders or bottles will affect the pressure outlet (Po) and flow (Vo) as the supply pressure (Ps) is depleted. Contact SC Hydraulic Engineering for detailed performance data on any 1 2 3 4 Outlet Gas Pressure (P Drive P A =9 psig Outlet Gas Pressure (P 5 1 15 2 25 3 35 4 45 5 55 6 =23 psig GBT-15/75 15 5 4 19 1 15 3 11 2 7 5 1 1 2 3 4 5 6 7 8 Outlet Gas Pressure (P Drive P A =9 psig Outlet Gas Pressure (P 1 2 3 4 5 6 7 8 15 =13 psig 4 GBT-3/75 GBT-15/75 12 9 6 3 1 7 4 3 2 1 GBT-3/75 1 2 4 6 8 1 12 Outlet Gas Pressure (P 18 SC Hydraulic Engineering 113 Columbia St. Brea, CA 92821 Tel 714-257-48 Fax 714-257-481 www.schydraulic.com

GBT-D SERIES Two Stage-Double Head Booster This series has the same characteristics of the standard GBT however the double head allows half the input pressure to achieve the same outlet pressure. 3/4" NPT AIR INPUT DRIVE, 15 psi MAX. 7.72" 32.53" 1.13" 4.75" A THREAD INLET SUPPLY 3.56" 2.99" 9.5" 15.74" 3.13".31" B THREAD PRESSURE OUTLET (OPPOSITE SIDE) Model No. Rated Gas Supply Rated Gas Outlet Pressure (Po) Inlet Port (A) Outlet Port (B) Static Outlet Stall Pressure Minimum Inlet Gas Displacement Per Stroke (in3 per cycle) 9, psig 1/4" NPT GBT-D15/3 3 Pa to 25 psi (2) 62 bar 1/4" NPT 25, psig 1/4 NPT GBT-D15/75 7 Pa to 5 psig (2) 1,725 bar 9/16"-18 (1) GBT-D3/75 4 Pa to 36 psig (2) 25, psig 1/4 NPT 1,725 bar 9/16"-18 (1) 6 Pa +2 Ps 1 psig (7 bar) 7.5 15 Pa + 5 Ps 1 psig (7 bar) 7.5 15 Pa + 2.5 Ps 1 psig (7 bar) 3.1 (1) Coned and Threaded High Pressure Connection for ¼ O.D. Tubing. (2) GBT Series Gas Boosters: Limit maximum gas supply pressure by formula Ps max = factor * Pa to avoid interstage stall (for example, for gas booster model GBT-15/3 the formula is: Ps max = 15*Pa). 3. Refer to corresponding gas booster performance curve for operating pressures (see page 9 to 2). 4. Maximum material rated outlet pressures can be reached under special operating conditions. Do not use air drive or/and gas supply pressures that equate to higher outlet pressures than those "maximum material rated outlet pressures" shown on table. Refer to Static Outlet Stall Pressure formula shown on table (for example, for gas booster model GBD-3 the formula is: Static Outlet Stall Pressure = 3*Pa+Ps). 5. Maximum recommended air drive operating pressure: 1-psi. 6. Maximum rated air drive pressure: 15-psi (only for static outlet stall pressure). For assistance in selecting the proper Gas Booster complete and fax the data work sheet or e-mail inquires to service@schydraulic.com 19 SC Hydraulic Engineering 113 Columbia St. Brea, CA 92821 Tel 714-257-48 Fax 714-257-481 www.schydraulic.com

GBT-D SERIES Two Stage-Double Head Booster Legend PA = Drive Pressure PO = Gas Outlet Pressure PS = Gas Inlet Pressure VO = Output Gas Flow Drive P A =9 psig Outlet Gas Pressure (P 1 2 3 4 5 6 7 25 =17 psig GBT-D15/3 6 2 15 1 5 9 5 1 13 5 4 3 2 1 GBT-D15/3 NOTE: Performance charts are for reference only. The curves are based on an Air Drive (Pa) of 9 psig and a maximum air consumption of 72-scfm. If the Pa is higher or lower, the Outlet gas pressure (Po) can change significantly. Also, the supply pressures (Ps) shown in the graphs are based on constant pressure being supplied as the pressure is boosted. A supply from cylinders or bottles will affect the pressure outlet (Po) and flow (Vo) as the supply pressure (Ps) is depleted. Contact SC Hydraulic Engineering for detailed performance data on any 1 2 3 4 5 6 7 8 9 Outlet Gas Pressure (P Drive P A =9 psig Outlet Gas Pressure (P 2 4 6 8 1 8 6 4 2 =5 psig GBT-D15/75 4 3 2 1 2 4 6 8 1 12 14 16 Outlet Gas Pressure (P Drive P A =9 psig Outlet Gas Pressure (P 2 4 6 8 1 12 2 18 =25 psig GBT-D3/75 16 14 2 12 15 1 8 1 6 5 4 2 2 4 6 8 1 12 14 16 18 2 Outlet Gas Pressure (P 25 2 15 1 5 5 4 3 2 1 ) - liter/mon. GBT-D15/75 GBT-D3/75 2 SC Hydraulic Engineering 113 Columbia St. Brea, CA 92821 Tel 714-257-48 Fax 714-257-481 www.schydraulic.com

GAS BOOSTER REFERENCE INFORMATION (see performance curves for operating conditions) Model No. Rated Gas Supply Rated Gas Outlet Pressure (Po) Inlet Port (A) Outlet Port (B) Static Outlet Stall Pressure Minimum Inlet Gas Displacement Per Stroke (in3 per cycle) GB-15 GB-3 2,25 psig 2,25 psig 1/4" NPT 155 bar 155 bar 1/4" NPT 4,5 psig 4,5 psig 1/4" NPT 31 bar 31 bar 1/4" NPT 15 Pa 5 psi (3.5 bar) 7.5 3 Pa 1 psig (7 bar) 3.1 GB-75 GB-D3 GB-D75 GBD-5 GBD-15 GBD-3 GBD-75 GBD-D15 GBD-D3 GBD-D75 GBT-15/3 6, psig 11,25 psig 9/16"-18 (1) 75 Pa 25 psig (17 bar) 1.2 41 bar 775 bar 9/16"-18 (1) 6, 9, 1/4" NPT 41 bar 62 bar 1/4" NPT 6 Pa 2 psig (13 bar) 3.1 6, 2, psig 9/16"-18 (1) 15 Pa 25 psig (17 bar) 1.2 41 bar 1,38 bar 9/16"-18 (1) 15 psig 15 1/2" NPT 13 bar 13 bar 1/2" NPT 5, psig 5, psig 1/4" NPT 345 bar 345 bar 1/4" NPT 6, psig 9, psig 1/4" NPT 41 bar 62 bar 1/4" NPT 4.7 Pa +Ps 25 psig 28.2 15 Pa + Ps 5 psi (3.5 bar) 14.1 3 Pa + Ps 1 psig (7 bar) 6.3 6, psig 2, psig 9/16"-18 (1) 75 Pa + Ps 25 psig (17 bar) 2.4 41 bar 1,38 bar 9/16"-18 (1) 5, psig 5, psig 1/4" NPT 345 bar 345 bar 1/4" NPT 6, psig 9, psig 1/4" NPT 41 bar 62 bar 1/4" NPT 3 Pa + Ps 5 psi (3.5 bar) 14.1 6 Pa + Ps 2 psig (14 bar) 6.3 6, psig 25, psig 9/16"-18 (1) 15 Pa + Ps 25 psig (17 bar) 2.4 41 bar 1,725 bar 9/16"-18 (1) 15 Pa to 25 psig (2) 9, psig 1/4" NPT 62 bar 1/4" NPT 3 Pa +2 Ps 5 psi (3.5 bar) 7.5 GBT-15/75 3.5 Pa to 5 psig (2) 2, psig 9/16"-18 (1) 75 Pa + 5 Ps 5 psi (3.5 bar) 7.5 1,38 bar 9/16"-18 (1) GBT-3/75 2 Pa to 6 psig (2) 2, psig 9/16"-18 (1) 75 Pa + 2.5 Ps 1 psig (7 bar) 3.1 1,38 bar 9/16"-18 (1) 9, psig 1/4" NPT GBT-D15/3 3 Pa to 25 psig (2) 62 bar 1/4" NPT 21 6 Pa +2 Ps 1 psig (7 bar) 7.5 GBT-D15/75 7 Pa to 5 psig (2) 25, psig 9/16"-18 (1) 15 Pa + 5 Ps 1 psig (7 bar) 6.3 1,725 bar 9/16"-18 (1) GBT-D3/75 4 Pa to 36 psig (2) 25, psig 9/16"-18 (1) 1,725 bar 9/16"-18 (1) 15 Pa + 2.5 Ps 1 psig (7 bar) 3.1 (1) Coned and Threaded High Pressure Connection for ¼ O.D. Tubing. (2) GBT Series Gas Boosters: Limit maximum gas supply pressure by formula Ps max = factor * Pa to avoid interstage stall (for example, for gas booster model GBT 15/3 the formula is: Ps max = 15*Pa). 3. Refer to corresponding gas booster performance curve for operating pressures (see page 9 to 2). 4. Maximum material rated outlet pressures can be reached under special operating conditions. Do not use air drive or/and gas supply pressures that equate to higher outlet pressures than those "maximum material rated outlet pressures" shown on table. Refer to Static Outlet Stall Pressure formula shown on table (for example, for gas booster model GBD-3 the formula is: Static Outlet Stall Pressure = 3*Pa+Ps). 5. Maximum recommended air drive operating pressure: 1-psi. 6. Maximum rated air drive pressure: 15-psi (only for static outlet stall pressure). Legend Pa = Drive Pressure Ps = Gas Inlet Pressure Po = Gas Outlet Pressure SC Hydraulic Engineering 113 Columbia St. Brea, CA 92821 Tel 714-257-48 Fax 714-257-481 www.schydraulic.com

HOW TO ORDER TABLE - M - / - 1 2 3 4 5 6 Table Reference Example #1 Pump Selection GB-15-O2 GB Series Single Stage (Blank) No Modification (Blank) Single Air Drive 15:1 Pressure Ratio (Blank) No Second Stage O2 Oxygen Service Example #2 Pump Selection GBT-M42-D 3/75 GBT Two Stage-Double Acting M42 Remote Pilot D Double Air Drive 3 First Stage Pressure Ratio 75 Second Stage Pressure Ratio (Blank) No Service Option GB -15 -O2 GBT-M42-D 3 / 75 TABLE 1 (1) Gas Booster Series GB Single Stage GBD Single Stage Double Acting GBT Two Stage Double Acting TABLE 2 Modification Blank No Modification 41 No Inlet/No Outlet Plumbing (2) 42 Remote Pilot 43 Plumbing for Single Inlet/Outlet (3) TABLE 4 Pressure Ratio Single or First Stage 5 GB, GBD, GBT 15 GB, GBD, GBT 3 GB, GBD, GBT 75 GB, GBD, GBT TABLE 5 Pressure Ratio Second Stage Blank 3 GBT 75 GBT TABLE 3 Blank D Cylinder Modification Single Head Double Head TABLE 6 Service Option Blank Standard O2 Oxygen Service (4) H2 Hydrogen Service (4) Notes: (1) Do not fill gap on a two digit description. (2) Available on GBD-5 model only. (3) Available on GBD and GBD-D models only. (4) Not available on GBD-D75, GBT-D15/75 and GBT-D3/75 models. Contact factory for more information. 22 SC Hydraulic Engineering 113 Columbia St. Brea, CA 92821 Tel 714-257-48 Fax 714-257-481 www.schydraulic.com

GAS BOOSTER SYSTEMS Standard or Custom SC Hydraulic Engineering Corporation builds every booster system like it s a custom unit built just for you. What separates us from other manufacturers is how fast we can ship you a complete system, whether it is considered a standard or in fact is a custom unit. We are able to do this because it is all we do. Our gas booster department builds only gas boosters and gas booster systems. The size of our company (we re proud of the fact we are not the largest) gives us the ability to be extremely flexible and work with each customer as an individual, not part of the herd. Our standard delivery for a complete system is one to two weeks, even quicker if you re willing to pay a nominal expedite fee. Better yet, a custom unit i.e. multiple boosters, extra ports, special valves, etc. is typically 3-4 week delivery. In most cases our deliveries are only extended if we have to wait for customer supplied add-on parts. Plus most of our manufactured parts are produced in house on state-of-the-art equipment. We are never dependent on some supplier s missed delivery, hence backing up all the orders in-house. Our standard booster systems are built in three categories depending on the maximum outlet pressure a unit can deliver, 6K, 2K, or 25K PSI. Virtually any booster we manufacture can be used in a system. Standard items on the booster are inlet air and gas supply filter, panel mounted air shut-off, regulator, air drive, gas supply and outlet gauges, and relief valve. Bulkhead connections for air supply, gas supply and gas outlet are mounted on the side of the tubular frame, Standard frames are 38 or 45 long depending on the booster model. Our 3-4 week delivery for specials is about half the time other manufacturers quote for a standard booster system! Standard options are outlet filter, automatic start and/ or stop pilot switches, hydrogen, or oxygen service. 37 or 45 21 17 Typical Gas Booster System Layout 23 SC Hydraulic Engineering 113 Columbia St. Brea, CA 92821 Tel 714-257-48 Fax 714-257-481 www.schydraulic.com

HOW TO ORDER TABLE STANDARD GAS BOOSTER SYSTEMS 1 2 3 4 5 6 Table Reference Example #1 Gas Booster System Selection Tubular Frame System for pressure to 6 psi Code 9 - APS-12-9 N.C. 23-124 psi range Code 2 - APS-7-2 N.O. 94-64 psi range 15 Micron Inlet Filter GBD-M42-15 Gas Booster S162-9 - 2-1 GBD-M42-15 TABLE 1 Gas System Designation (based on max PSI) S162 System to 1, PSI w/ no relief valve S1621 System to 1, PSI w/ 6K relief valve S1622 System to 1, PSI w/ 1K relief valve S163 System to 2, PSI w/ no relief valve S1631 System to 2, PSI w/ 2K relief valve S164 System to 25, PSI w/ no relief valve S1641 System to 25, PSI w/ 25K relief valve TABLE 2 Air Pilot Switch Low Side No switch (standard) XX N.C. Use code from list on page 25 TABLE 4 Gas Filter No Filter 1 Filter on inlet, 15 µ (standard) 2 Filter on outlet, as specified 3 Filter on inlet and outlet TABLE 5 Booster Model Number Model number including modification. See How to Order page 22. TABLE 6 Service Option Blank Standard Service TABLE 3 Air Pilot Switch High Side No switch (standard) XX N.O. Use code from list on page 25 24 SC Hydraulic Engineering 113 Columbia St. Brea, CA 92821 Tel 714-257-48 Fax 714-257-481 www.schydraulic.com

AIR PILOT SWITCH CODES Air pilot switch valves can used to automatically start and stop a gas booster system so that gas supplies are not depleted completely and/or the system stops at a predetermined pressure. When using a automatic start or stop a remote pilot must be specified on the gas booster. SC Hydraulic Engineering will preset the valves to your requirements if requested. Use this chart to select the desired air pilot switch for your gas booster system if selected as an option. Choose a normally closed N.C. for the automatic start and a normally open N.O. for the automatic stop. Select the proper code from column three and add to the booster system model number. SC Hydraulic Engineering will adjust the automatic start and/or stop at the factory. Model No.* Type System Order Code AIR PILOT SWITCH VALVE SELECTION Sensing Port Size Max. Pressure Adjustable Range (psig) Pressure setting at factory. Specify increasing/decreasing Normally Closed Air Valves 15 psig Maximum Operating Pressure Normally Open Port Size Cv Factor Air Valve Configure Option APS-1-1 1 3,5-1, 2,4-1, APS-7-2 2 1,4-7, 94-6,4.2 15, psi N.C. & APS-51-3 A 3 1/4" NPT 8-5,1 7-4,6 1/8" npt UP TO O 2 = 5, N.O. APS-13-4 4 34-1,3 26-1,2 11 SCFM APS-148-5 5 3,5-14,8 2,5-12, APS-1-6 6 3,5-1, APS-7-7 7 15, psi 1,36-7,.13 B 1/4" NPT 1/8" npt UP TO APS-5-8 8 O 2 = 5, 68-5, 7 SCFM N.C. APS-12-9 9 23-1,24 APS-5-1 1 17-55 125-51 APS-2-11 11 7-21 5-19.2 N.O. & A 1/4" NPT 1/8" npt UP TO APS-1-12 12 5-13 4-13 N.C. 11 SCFM APS--13 13 25-5 2-46 3, psi APS-5-14 14 145-52 APS-2-15 15 55-21.13 B 1/4" NPT UP TO APS-1-16 16 3-135 1/8" npt 7 SCFM N.C. APS--17 17 15-45 APS-2-18 A 18 HF4 2, psi 3,-2, 3,-2,.2 UP TO 11 SCFM N.O. & N.C. 25 SC Hydraulic Engineering 113 Columbia St. Brea, CA 92821 Tel 714-257-48 Fax 714-257-481 www.schydraulic.com

LIMITED WARRANTY SC manufactured products are warranted free of original defects in material and workmanship for a period of one year from date of purchase to first user. This warranty does not include packing, seals or failures caused by lack of proper maintenance, incompatible fluids, foreign materials in the air media, in the fluid media or application of pressures beyond catalog ratings. Products believed to be originally defective may be returned, freight prepaid, for repair and/or replacement to the distributor, authorized service representative or to the factory. If upon inspection by the factory or authorized service representative and the problem is found to be originally defective material or workmanship, repair or replacement will be made at no charge for labor and materials, F.O.B. the point of repair or replacement. Permission to return under warranty should be requested prior to shipment. A Return Material Authorization Number (RMA), the original purchase date, purchase order number, serial number, model number, reason for return or other pertinent data to establish warranty claim must be included in the documentation to expedite the return or replacement to the owner. If the unit has been disassembled, misused, or altered without prior written authorization, warranty is void. If it has been improperly reassembled or substitute parts have been used in place of factory manufactured parts, warranty is void. Any modification to any SC product which you have made or may make in the future will void warranty. SC disclaims any and all liability obligation, or responsibility for the modified product, and for any claims, demands or causes of action for damage or for personal injuries resulting from the modification and/or use of such a modified SC product. SC's obligation with respect to its products shall be limited to replacement, and in no event shall SC be liable for any loss or damage, consequential or special, of whatever kind or nature, or any other expense which may arise in connection with or as a result of such products or the use or incorporation thereof in a job. This warranty is expressly made in lieu of all other warranties of merchantability and fitness for a particular purpose. No express warranty and no implied warranties whether of merchantability or fitness for a particular purpose or otherwise, other than those expressly set forth above, shall apply to SC products. 27 SC Hydraulic Engineering 113 Columbia St. Brea, CA 92821 Tel 714-257-48 Fax 714-257-481 www.schydraulic.com

Designers and Manufacturers of Hydraulic and Pneumatic Equipment 113 Columbia Street - Brea, California 92821 - USA Phone (714) 257-48 - Fax (714) 257-481 Designers and Manufacturers of Hydraulic and Pneumatic Equipment 113 Columbia Street - Brea, California 92821 - USA Phone (714) 257-48 - Fax (714) 257-481 Designers and Manufacturers of Hydraulic and Pneumatic Equipment 113 Columbia Street - Brea, California 92821 - USA Phone (714) 257-48 - Fax (714) 257-481 Designers and Manufacturers of Hydraulic and Pneumatic Equipment 113 Columbia Street - Brea, California 92821 - USA Phone (714) 257-48 - Fax (714) 257-481 Designers and Manufacturers of Hydraulic and Pneumatic Equipment 113 Columbia Street - Brea, California 92821 - USA Phone (714) 257-48 - Fax (714) 257-481 Designers and Manufacturers of Hydraulic and Pneumatic Equipment 113 Columbia Street - Brea, California 92821 - USA Phone (714) 257-48 - Fax (714) 257-481 Other catalogs available from SC Hydraulic Engineering. Contact your local distributor or us direct and request the one(s) you need by name or number. Catalogs are also available online at www.schydraulic.com. P U M P S P U M P S P U M P S SC HYDRAULIC ENGINEERING CORPORATION DL & 1 SERIES AIR OPERATED LIQUID PUMPS SC HYDRAULIC ENGINEERING CORPORATION L1 SERIES AIR OPERATED DOUBLE-ACTING PUMPS D/1 SERIES AIR OPERATED LIQUID PUMPS Three sizes to choose from with various ratios. Pressures to 65, psi L3 Series Air Operated Liquid Pumps Compact sized pumps for pressures up to 15,6 psi plus three styles of power units. L1 SERIES AIR OPERATED LIQUID PUMPS 1 Air drive double-acting pump for pressures up to 3, psi. AIR BOOSTERS & SYSTEMS Compact and double-acting up to 5:1 ratio plus booster systems with reservoirs and air controls. SC HYDRAULIC ENGINEERING CORPORATION D & 1 SERIES POWER UNITS Catalog # D15 Catalog # D152 Catalog # D157 Catalog # D151 Catalog # D154 FLOW CONTROL & AIR PILOT SWITCH VALVES High pressure check, sequence, release, relief, and air pilot switch valves for liquid and gas applications. P U M P S B O O S T E R SC HYDRAULIC ENGINEERING CORPORATION L3 SERIES AIR OPERATED COMPACT PUMPS SC HYDRAULIC ENGINEERING CORPORATION AB/ABD AIR BOOSTERS & SYSTEMS D/1 SERIES POWER UNITS Six different types with and without reservoirs and pressures up to 65, psi. All non-electric. Catalog # D156 V A L V E SC HYDRAULIC ENGINEERING CORPORATION FLOW CONTROL & AIR PILOT SWITCH VALVES Distributed by: Catalog D155 Rev 11-21-16