RESIDENTIAL IRRIGATION WORKSHOP IRRIGATION 101 AND BEYOND FOR WEST BENCH RESIDENTS

Similar documents
MUELLER. Mega-Lite Drilling Machine. Reliable Connections. table of contents PAGE. Equipment 2. Operating Instructions 3-4. Parts Information 5

DS05C,D,G Dial Set Pressure Regulating Valves

Winter Shut Down Procedure

Valves. Controllers. Valves Two Types

pvc well casing & drop pipe

Exercise 2-3. Flow Rate and Velocity EXERCISE OBJECTIVE C C C

Pumping Systems for Landscaping Pumps, Controls and Accessories. Mark Snyder, PE

INDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES

Irrigation System Winterization and Pressurization Procedures

NAVIGATOR PROP BUILDING INSTRUCTIONS & PHOTOS

Float Equipment TYPE 925/926

Rain Barrels. Did You Know?

Blue Points 1 ¼ WELL POINT INSTALLATION INSTRUCTIONS

Models: C62/63/64-A/D

SECTION PRESSURE TESTING OF PIPING

Technical Service Bulletin June 2015 TSB122.06

Quality Plastic Pipe Fittings. Technical Data. Fabricated PVC Fittings IPS Class 100, 125, 160, 200 SCH 40 & SCH 80 Solvent Weld & Gasketed

SIZING OF WATER PIPING SYSTEM

ESCONDIDO FIRE DEPT TRAINING MANUAL Section DRIVER OPERATOR Page 1 of 14 Hydraulics Revised

San Antonio Water System Standard Specifications for Construction ITEM NO. 841 HYDROSTATIC TESTING OPERATIONS

installation best practices pocket guide

INSTALLATION INSTRUCTIONS FOR GRT75-PF-RFS PET FOUNTAIN

Practice Test FOR GAS POSITIONS APTITUDE BATTERY

4 IN. BALL LAUNCHER Engine Mounted / PTO Driven

Model 7989T Steel Pipe Squeezer Sch. 40 & Sch. 80. Operations Manual

TECHNICAL DATA. Page 1 of 8. model f /2 (dn40) & 2 (dn50)

VACUUM TESTING PRECAST CONCRETE MANHOLES

D05 Pressure Regulating Valves

TECHNICAL DATA. Q = C v P S

Assembly Drawing: W-311B-A01, or as applicable Parts List: W-311B-A01-1, or as applicable Special Tools: , , &

PANACEA P125 USER MANUAL

Rain Barrel Set Up. Supplies: Most supplies are available at your local hardware stores.

SLIDE. Super Sweet. instruction manual SLIP SLIDE SPLASH INFLATE THE FUN WITH THINGS YOU NEED TO KNOW ABOUT THE SUPER SWEET SLIDE.

DIVERLESS SUBSEA HOT TAPPING OF PRODUCTION PIPELINES

RANGER PROP BUILDING INSTRUCTIONS & PHOTOS

Type 967 Diamond Broaching Type 968 Sidewinder reamer shoe

VRS Assembly & Operating Instructions

PANACEA P100 LOW PRESSURE USER MANUAL

Rod DISOGRIN Asymmetrical U-Cup Rod series U-cup with an asymmetrical profile of the sealing lips,

PURPOSE OF THE POLICY

T e l N o : F a x N o : E m a i l : a i s h c m c - m e. c o m w w w. c m c - m e.

PVC FASTTAP SADDLES for IPS Mains. Main Size OUTLET 1 FPT 3/4 CTS (7/8 OD) COMPRESSION 1 CTS (1 1/8 OD) COMPRESSION 3/4 IPS COMPRESSION

TECHNICAL DATA. Q = C v P S

INSTRUMENTATION TUBING

Blue River Technologies Port-A-Poly Mixer w/2.5 GPH LMI Pump And Secondary Water Dilution Line INSTALLATION AND OPERATION

SIZING THE WELL-X-TROL

Agricultural Water: Part 2

D05T Compact Design Pressure Regulating Valves

PORT ST. LUCIE UTILITY SYSTEMS DEPARTMENT FLUSHING REPORT

Bermad Pressure Reducing. Model: 42T

Copyright, 2005 GPM Hydraulic Consulting, Inc.

Log Balance Beam. Product: (4 ), (6 )

Emergency Shower & Eyewash. Training Guide

PumpAgents.com - Click here for Pricing/Ordering Nominal psi (bar) Cut-In Cut-Out

Hydraulic Punch Drivers

HPB25 Hydraulic Paving Breaker

PANACEA P200 STAINLESS STEEL USER MANUAL

Injection Systems INSTALLATION AND OPERATING GUIDE HI FLO VERTICAL TANK SYSTEMS

TEST FOR STABILOMETER VALUE OF BITUMINOUS MIXTURES

TECHNICAL DATA. Q = C v P S

CLEANING, INSPECTION, AND TESTING OF SEWERS

Un-Pressurized Orefice Fittings FIO EZ. Parts List and Operation Instructions TECHNICAL MANUAL. Dn 2-6 Class Lbs

TECHNICAL DATA. Q = C v P S

SIZING OF WATER PIPING SYSTEM

WHP Operations and Methods { July William M. Smethie, Jr. Lamont Doherty Geological Observatory Palisades, New York U.S.A.

Flow Sensors & Hydrometers Specification Sheet

Residential Meters. Available innov8 Outputs 900 MHz Radio Virtual Network 3W Standard AMR 2W AMR 2W Standard Touchpad Scalable Pulse 4-20mA SCADA

Any tool, at the ready. 3M DBI-SALA Fall Protection for Tools Pocket Reference Guide

PRO-50 Instrument Supply Regulator

Technical Service Bulletin Oct 2017 TSB122.07

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

Inflatable Packer Single & Double. Single & Double Packer Dimension. Wireline Packer. Water Testing Packer (WTP) Packer

MANUAL FLOW CONTROL 2-1/2" - 18" QUICKSET FLOW CHART

CB7 Bayonets Male & Female 1/4", 3/8, & 1/2 Size

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

TECHNICAL DATA. Q= Cv S

Anti-flood device Model B-1

Operator: Save these instructions for future use!

Borais Petroleum Investment Co. SLOT RECOVERY SERVICE General Procedures

TECHNICAL DATA Q= C. Table 1 - Specifications

PRESSURE REGULATOR GUIDE

TECHNICAL DATA OBSOLETE

Figure 1: Hydrostatic Pressure Forces Are Perpendicular to the Surface

TECHNICAL DATA. Page 1 of 12

Putting it All Together: Making Sense of Drip Irrigation UC Master Gardener Conference August 24, 2017

KENNEDY VALVE OPERATION & MAINTENANCE MANUAL

PO Box 370 Phone: Swansea NSW 2281 Fax: AUSTRALIA Mobile: Web:

TECHNICAL DATA. Q = C v P S

PROCESS ROTATING EQUIPMENT (CENTRIFUGAL PUMPS )

APPENDIX A RECOMMENDED RULES FOR SIZING THE WATER SUPPLY SYSTEM CHART A 1.2 FRICTION LOSSES FOR DISK-TYPE WATER METERS 1-1/2"

appendix a recommended rules For sizing the water supply system PRE-PRINT Chart a 1.2 FriCtion losses For Disk-type water Meters

TECHNICAL DATA. Q = C v P S

APPENDIX A RECOMMENDED RULES FOR SIZING THE WATER SUPPLY SYSTEMS CHART A-1 FRICTION LOSSES FOR DISK-TYPE WATER METERS 1-1/2"

GRAVEL/ FILTERS IRRIGATION EQUIPMENT LTD. SERIES APPLICATIONS

Vacutrans Instructions

TECHNICAL DATA DELUGE VALVE, MODEL F-1 STRAIGHT THROUGH STYLE

Model 420-HY Pressure Regulating Hydrant Valve

Water Pressure Reducing Valves

float equipment OPERATING MANUAL TYPE 505/506 Float Equipment 1. INFORMATION & RECOMMENDATIONS Float Equipment

I T T Pressure Reducing Valve WARNING INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

Transcription:

RESIDENTIAL IRRIGATION WORKSHOP IRRIGATION 101 AND BEYOND FOR WEST BENCH RESIDENTS

UNDERSTANDING BASIC HYDRAULICS Hydraulics is defined as the study of fluid behavior, at rest and in motion. Also known as: Static pressure & Dynamic pressure IDM IRRIGATION DESIGN MANAGEMENT

UNDERSTANDING BASIC HYDRAULICS One gallon of water weighs 8.3 lbs A cubic foot of water weighs 62.4 lbs A cubic inch of water weighs.036 lbs MANAGEMENT IDM IRRIGATION DESIGN

UNDERSTANDING BASIC HYDRAULICS P = Force Area P = pressure in pounds per square inch (PSI) F = force in pounds A = area in square inches MANAGEMENT IDM IRRIGATION DESIGN

UNDERSTANDING BASIC HYDRAULICS One foot of water =.433 psi One psi = 2.31 ft IDM IRRIGATION DESIGN MANAGEMENT

UNDERSTANDING BASIC HYDRAULICS A container 1 in 2 is filled with water to a height of 1 ft. How much pressure (psi) is being exerted at the bottom of the container? P = F =.036 lb in 3 x 12 in 3 = 0.433 lb A 1 in x 1 in 1 in 2 P = 0.433 psi MANAGEMENT IDM IRRIGATION DESIGN

UNDERSTANDING BASIC HYDRAULICS Friction loss is the reduction of water pressure which occurs as water travels over distance and through any kind of restriction. IDM IRRIGATION DESIGN MANAGEMENT

STATIC WATER PRESSURE Static water pressure refers to the pressure of a closed system with no water moving. IDM IRRIGATION DESIGN MANAGEMENT

DYNAMIC WATER PRESSURE The dynamic water pressure is the pressure at any point in the system considering a given quantity of water flowing past that point. IDM IRRIGATION DESIGN MANAGEMENT

MEASURE FAUCET FLOW RATE While measuring the dynamic water pressure, open the faucet till the pressure gauge reeds minimal pressure required. Quickly place the container under the running water and time how long it takes to fill.

MEASURE FAUCET FLOW RATE For: e.g. If the 5 gallon bucket takes 40 seconds to fill, how many gallons will you get in 1 minute? 40 seconds = 8 GPM 5 gallons You have now established the maximum GPM and the approximate working pressure available for the sprinkler system.

SOLVENT WELDING PIPE Use the two-step method (employing cleaner/primer and solvent). Inspect the pipe end and fitting socket for cracks, gouges, dirt, and abrasion. Test-fit them. The pipe should enter the fitting but meet resistance part-way in. Held upside down, it should hold on and not fall off. Cut pipes. Cut the pipe off squarely to proper length using a fine-tooth saw or plastic pipe cutter then remove any burrs left behind. Clean them. Using a quality cleaner/primer, clean the pipe end and fitting socket. Apply cleaner/primer with a dauber to remove grease, oil, dirt, and to prepare the plastic mating surfaces for solvent cement action. The pipe should be dry before applying cement. Solvent welding. Brush on a coat of ASTM-rated solvent cement that is matched to the type of pipe and fitting you are using. It is important that the solvent cement is the right type. Liberally apply cement first to the pipe end and then apply it sparingly to the fitting socket. Leave no bare spots. Immediately join pipe and fitting full depth with a slight twist that brings it to correct alignment. The twist breaks up insertion lines in the solvent cement. Hold the fitting on until the solvent cement grabs tightly. The fillet of cement around the fitting indicates that enough solvent cement was used to ensure a leak-free joint. With PVC do not wipe off the fillet. The joint should be ready for use in an hour. The rule of thumb is a minimum of 1 hour for every 1 of diameter.

WATER METER

PRESSURE-REDUCING VALVE Acts as a buffer between the high water pressure supply and the system. IDM IRRIGATION DESIGN MANAGEMENT

IRRIGATION CONTROLLERS They can be simple devises with sliders to control functions or as complex as a central control system that might be utilized by a city to control all it s green space. IDM IRRIGATION DESIGN MANAGEMENT

RAIN SENSORS The reliable wireless and wired rain sensors conserve water by preventing irrigation during or after sufficient rainfall.

IDM IRRIGATION DESIGN MANAGEMENT IRRIGATION CONTROLLERS The controller has two different imputes for each valve. First impute is called the common, this will either be marked with a C or COM in the controller, one wire from all valves will be linked to this impute in series. On the controller board we will find a number of imputes labeled with numbers, each one will represent a zone or individual valve, a single wire will be required from each valve to one of these impute.

SOLENOID VALVE Within a series of chambers the valve utilizes line water pressure exerted over diaphragm surfaces to control the movement of the diaphragm IDM IRRIGATION DESIGN MANAGEMENT

SOLENOID VALVE Rule #1 When there is an issue with the valve not shutting off, the problem will be with the diaphragm. The easiest cure is just to replace it with a new one. Rule #2 When there is an issue with the valve not opening when using the controller, the problem will be electrical to do with the solenoid or the wire leading to the solenoid (a break). IDM IRRIGATION DESIGN MANAGEMENT

WEEPING VALVES Weeping valve can be caused by debris in solenoid or diaphragm. If you have water flowing from a sprinkler head continuously, even when the sprinkler system is off, then the problem is a leaking control valve Another common sign is puddles of water around the lowest sprinklers that never dry out. To fix the leaking valve you must disassemble the valve, clean it and replace any bad parts, then reassemble it.